Securefast SBL339/SP Installation Instructions Manual

T/SED900/016A
Figure 4b
Figure 4
For Right-handed use
After removing the Grub Screw; lift and rotate the lever handle 180 degrees anti-clockwise. Relocate the grub screw and tighten to secure lever handle
Locate the Grub Screw in the Lever Handle unscrew and remove it using the supplied Allen Key.
Locate the Grub Screw in the Lever Handle unscrew and remove it using the supplied Allen Key.
After removing the Grub Screw; lift and rotate the lever handle 180 degrees clockwise. Relocate the grub screw and tighten to secure lever handle
Installation Instructions for Panic or Emergency Latch with SBL339/SP Digital Mechanical Lock
Installation
internal door face, at the correct height from the floor level.
Mark the 4 pilot holes for fixing the Latch Unit. Mark the 19mm diameter hole for the spindle of the Digital Lock Mark the two 8mm holes for bolt through fixings and cup washers to secure the Digital
Mechanical Lock.
If fixing to Rebated Double Doors mark hole positioning for Universal Strike on the Inactive Leaf. Drill all marked holes.
Setting/Changing the Code
On the reverse of the Digital Lock Unit you will see slotted buttons which
correspond to the push buttons on the front of the Lock.
To set a button to operate within the code turn the slotted button relating to
the number so that the dot is facing outwards (towards the ‘G’)
To take a button out the code turn the slotted button so the dot is facing
inward (towards the ‘F’)
Check the code on the Lock functions before fitting to the door.
IMPORTANT: Always press the ‘C’ button before inputting the programmed code
Handing the Digital Keypad
For Left-handed use
Positioning of Adapter in Follower
For Left handed applications the adapter should be positioned in the
follower of the Latch Unit as shown in Figure 4
For Right handed applications the adapter should be positioned in the
follower of the Latch unit as shown in Figure 4b
22nd August 2018
T/SED900/016A
Fixing the Lock
Cut the fixing bolts to suit door thickness, for the Digital Mechanical Lock, allowing at least 4/5
threads to screw into the lock case
Locate the rubber seal behind the Digital Lock and using the fixing bolts and cup washers secure
the top and bottom of the Lock to the door.
Before final tightening ensure the lock is vertical and test mechanism to ensure that it is moving
freely.
Fixing Panic and Emergency Latch
Insert Connecting bar and locate with follower of Digital Lock ensuring there is 12mm of
engagement with the Latch Unit. ( Shorten if necessary)
Position Latch unit and secure to door using wood screws. Before final tightening make sure the latch is vertical and test mechanism to ensure that it is
moving freely.
22nd August 2018
Loading...