SES 302 and SES 303
Temperature & Humidity Sensor
User and Installation Instructions
BGX501-923-03

SES 302 and SES 303
The S ecure S ES 302 and SES 303 form
p art of a Z-Wave P lus™ home automat io n
network. The SES 302 measure s
temperature whilst the SES 303 measures
temp erature an d humidity. Th e sens ors are
battery-operated d evices w hich t ransmi t
information to an associa te d device in a
network.
The SES 302 a nd SES 303 are fully
compliant Z-Wav e Plus™ devices which will
work with other manu fac turer’s Z-Wave
devices.
2

External Pip e and Tank Temperature
Sensors (Optional)
The SES 302/303 can support either
1-thermi stor (SE S 0 01) or up to 4-external
d igital temperature se nsors (SES 002/003).
Please take note of the f oll owing:
1. Refer “Produ ct Order ing Code s” sect ion
for order detai l s.
2. The connector for exter nal probes is on
th e rear w all plate.
3. The conne ctor is only for connecting
external sensors .
4. Do not connect to the mains.
3

W all P late
TOPTOP
1 2 3 4 5
Conne ctor for
External
Sensors
5. Refer to t he P ip e/ Ta nk t emperature
sensor (SES 00x) manua l for the
c on nection diagram.
4

Installation
Keep the SES 302 / SES 303 in its sealed
pack until all dust and debris have been
cleared away prior to ma king connections .
Remove the wall p late f rom t he rear of t he
SES 302/303.
a) The w all plate ca n be released by
pressing the spri ng clips on the bott om
of the wall plate
b) While pres s ing spring cl ips, swing the
wall plate out and down to remove.
5

a) Push spri ng cli ps to r elease b) Sw ing wal lpl ate out and dow n
Wallplate

Choose the positi on where the unit is to be
mounted (refer to the following layout).
Avoid locati ons alongsi de or behind large
metal surfaces tha t could i nterfere with th e
lo w po wer rad io signals between the unit

and the controlle r. The sensor shou ld be
mounted on an internal wall, appr oximately
1.5 me tres (5 f eet) ab ov e floor level and
away from draughts, direct heat sources and
sunlight.
Mak e sure th at th ere is suffic ien t spac e
around the unit to all ow easy access to the
two retai ning spring cli ps on the base of the
wall plate.
It may be necessary to move the sensor
around to ensure good communication.
Do n ot attempt to m ount it on the wall until it
has been i ncluded on the net work.
Note: Inclusion means add and exclusion means delete.
8

Including and Excluding a Device
Fit 2 x A A
1.5V
batteries
Check
correct
polarity
Fit t he tw o sup plied AA b at teries. The
b attery compart ment i s m arked with a plus
and minus sign. Ensure that eac h battery is
c orrectly ali gn ed. The SES 302/303 will now
power up.
9

Step 1: On the Z-Wave controller, s elec t
Include if yo u are ad ding a dev ic e to the
network or select Exclude if yo u are
removing a device from the network. Check
with the controller manu fac turer’s manual .
Step 2: O n the SES 302 or SES 303, press
the button, ho ld a nd relea se a fter 1 s econ d
10

to send a re quest (Network Information
Frame) to jo in the network.
On succe ss fu l inclusion the LED will flash
2 times.
The total proces s can ta ke u p to 2 0
seconds; refer to the “Radio” section for
details.
If t he LED flashes 4-times this means that
the inclusion proce ss ha s f ailed, so try
moving the SES 302/SES 303 to a nother
position a nd re peat the Incl usion steps. If
the inclusion process fails again, the device
may be alre ady included in another n etwo r k.
So first exclude and then include the device.
11

The controller will show when the incl usion/
Exclusion operation is successful.
Asso ciati ng a Device on a Z-Wave
Network
Association process is applicable only after
devi ce included onto n etwork) Pleas e no te
th at some cont rol lers ca n automatic ally
associate. Al ways check with the
manufacturer’s manual.
Step 1: Put the contr oller int o Association
Mode.
Step 2: Press and hold SES 302/ SES 303
button for more than 1 second and the n
release.
12

Step 3: The controller will confirm
association when the process is successfully
completed.
RF commu ni cat ion check after
installation
Press button for less than 1 se cond. The
SES 302/SES 303 will send temperature
report of onboard sensor.
Note: this fe ature only works when the
device has been inc lud ed in netw ork a nd the
nodes associated.
Se nding Node Information - Pr ess an d hold
SES 302/303 button for more than 1 second
and then re le ase .
13

Device E ndpoints details
End Point
No.
Reports to the nodes at the Endpoint
1
Measured Temperature report.
Measured Humidity report.
Low battery Alarm report.
2
Temperature report external digital sensor
01 or thermistor.
Temperature report external digital sensor
02.
4
Temperature report external digital sensor
Temperature report external digital sensor
04

Te chnic a l Informa tion of Z-Wave
Plus command classes
Z-Wave Plus Device
Classes
I mplemented Device Class
Generic
Routing Multilevel sensor
Battery operated devices do not support routing
functionality.
Multilevel Sensor (V6)
Get
Used to report measured sensor values to associated
nodes.
Manufacturer Specific Get
Manufacturer Specific Report

Manufactur er ID = 0 x0059
Product Type ID = 0x000D
Product ID = 0x0002 (SES 302)
Product ID = 0x0003 (SES 303)
Version Command Class Get
Version Command Class
Report
Battery report is issued on a battery change or when a
low-level battery is detected.
Wake Up Interval Capabilities
Get
Wake Up Interval Capabilities

Wake Up No More Information
Wakeup interval step is 60 seconds
Minimum wakeup interval is 2 minutes
Maximum wakeup interval is 24 hours
Default wakeup interval is 24 hours
Supported Groupings Report
Specific Group Get Command
Specific Group Report
Command
Product supports one group for each end point that have
a maximum of 2 nodes.
Multi Channel End Point Get
Multi Channel End Point
Report
Multi Channel Capability Get

Multi Channel Capability
Report
Multi Channel End Point Find
Multi Channel End Point Find
Multi Channel Command
Encapsulation

Up to a maximum of five end points supported. The
number of end points on the product is detected based
on the number of external sensors connected to the
product at the time of Inclusion.
I f external sensor not connected this command class is
not supported.
Note: external digital sensors must have correct
hardware address otherwise it will not work.
For example: If one external sensor is connected it
should have HW address 1. If two external sensors are
connected it should have HW address 1 and 2
Note: Refer to the Pipe/Tank temperature sensor (SES
00x) manual for device address setting.

For configuration details refer to the “Configuration
Parameters” section.
Device Locally Reset (V1)
Button press 3 times within 3 seconds will put the device
in factory default, that include setting all the configuration,
Association to factory default and removing the device
Group Command List Report
Only one association group is supported on each end
point and its name is “Lifeline”.

ASSOCIATION_GROUP_INFO_REPORT_PROFILE_G
ENERAL
Profile LSB ASSOCIATION_GROUP_INFO_REPORT_PROFILE_G
ENERAL_NA
Supported Command class and command :
1. COMMAND_CLASS_SENSOR_MULTILEVEL,
SENSOR_MULTILEVEL_REPORT_V6
2. COMMAND_CLASS_BATTERY,
BATTERY_REPORT

ROLE_TYPE_SLAVE_SLEEPING_REPORTING
Node Type ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEP
LUS_NODE
I nstaller IconICON_TYPE_SPECIFIC_SENSOR_MULTILEVEL_MUL
TIDEVICE
User IconICON_TYPE_SPECIFIC_SENSOR_MULTILEVEL_MUL
Power Level Test Node Set
Power Level Test Node Get
Power Level Test Node Report

Access Types = Read/ Write
Size Bytes = 1, Min Value = 0, Max Value = 255
Zero configuration mean that the corresponding
functionality is disabled.
Configuration value = Desired value/ Resolution.
Example: To configure Delta temperature to 2 °C. The
value need to be configured in device is 2/0.1 = 20.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range
128…255, the value sent in the application shall be equal
to desired value minus 256. For example, to set Delta
Temperature to 130, it may be needed to set a value
130−256=−126.
Note: For more information about Z-Wave command
classes and their use refer “SDS12652 Z-Wave
Command Class Specification” ver 3 or above and
“SDS12657 Z-Wave Command Class Specification” ver 2
or above.
24

Thermistor Temperature
Sensor with 3m cable

Technical Specifications
Specific at ion ap pl ies to b oth SE S 302 and
SES 303 unles s otherw is e sta ted.
Electrical
Purpose of Control: Electronic Te mperature and
Humidity Sensor (Independently
Mounted)
Software Class: Cla ss A
Batter y operated device using two AA batteries.
** Do not use rechargeable batteries**
Each battery: 1.5V
Nominal Life: 2 years (with onboard & 4 wired
temp sensors with the default
configuration)
26

For 5-years battery life, delta reporting should be zero
and no external sensors:
(1) SES 302: configure >15min reporting interval
(2) SES 303: configure >1hour reporting interval
Measurement
Temperature Accuracy: ±0.5°C for 0°C to
40°C
Temperature Accuracy: ±0.5°C for 0°C to
40°C
Humidity Accuracy: ±3% RH for 20% RH
to 80% RH
Accuracy of optional NTC temperature
probe: ±1.0°C for 15°C to 85°C
Accuracy of optional pipe / tank sensor:
±0.5°C for 0°C to 65°C &±1°C for 66°C

After Care: Clean only with a clean damp cloth; do not
use any aggressive cleaning agents. If cleaning agents
are necessary, check compatibility before use.
28

Environmental
Storage temperature: -20°C to 55°C
Operating temperature: 0°C to 40°C
Environmental humidity range: 0%RH to 95%RH
Atmospheric Range: 980 to 1035 hPa
Pollution Degree: Degree 2
Enclosure protection: IP30
Radio
Receiver Category: Category 3
Power Class: Class B
RF frequency
Europe & UK: 868.42MHz
ANZ: 921.42MHz
RF range: 100m line of sight in
open air.
Inclusion: If the Z-Wave controller does not respond
within 2-seconds then the SES will try with NWI (Network
Wise Inclusion). The total process can take up to 20
seconds.
29

This is a Z-Wave certified product and can be used with
Z-Wave controllers that support its functionality. Please
refer to the documentation provided by the gateway or
controller manufacturer. See the Z-Wave alliance website
www.z-wavealliance.org for certified controllers.
Compliance
IEC 61010-1
R&TTE directiv e
ETSI EN 300 220-2
EN 301 489 part 1 & 3
EN 61000 – 4 -2 & 3.
30

European Head Office
Secure Controls (UK) Ltd.
South Bristol Business Park
Roman Farm Road
Bristol, BS4 1UP, UK
e: info@securetogether.com
www.securetogether.com
European Sales Office
CEWE Instrument AB
Box 1006, 611 31 Nyköping
t: +46 8 600 80 60
e: info@securetogether.com
www.securetogether.com
34

Australia Sales Office
Secure Australasia Pty Ltd
258 Darebin Road
Fairfield VIC 3078
Australia
p: +61 3 9485 6000
f: +61 3 9485 6099
e: info@securetogether.com
www.securetogether.com
Secure Meters Ltd
Pratapnagar Industrial Area
Udaipur 313003
India
p: +91 294 2492 300-05
f: +91 294 2492 310
e: mktg@securetogether.com
www.securetogether.com
35

El egant Metering Solutions FZE
4EA 326, P.O. Box 54857
Dubai Airport Free Zone
Dubai, UAE
p: +971 50 6575166
f: +971 04 204 5619
e:
emsfze@emsdxb.ae
www.securetogether.com