1
The Secure CentaurPlus C17-ZW has the functionality of a timeswitch with the addition of a Zwave RF interface, providing the additional capability of being controlled by a 3rd party controller.
CentaurPlus C17-ZW allows the schedule to be locally programmed and maintained, providing the user with up to 3on /offs per day with different timings possible for each day of the week.
CentaurPlus ZW Timeswitch
User and Installation Instructions
2
User Instructions
The CentaurPlus C17-ZW Timeswitch
The simple instructions contained in this user guide are designed to help with the
programming and operation of the unit.
1 SET indicator - RUN is the normal position
2 Time of day 3 Switch period symbol 4 SET button 5 BOOST or adjust (-) button 6 ADVANCE or adjust (+) button 7 ENTER button 8 SELECT or COPY button
9 System ON indicator 10 SETTING positions 11 PROGRAMME settings 12 BOOST symbol 13 ADVANCE symbol 14 AM/PM symbol 15 Day of week indicator 16 PROGRAMME indicator 17 RF signal indications
The indicator against the radio mast symbol on the
CentaurPlus ZW shows that the radio link is established.
A flashing indicator means that the wireless connection
has been temporarily lost.
If no indicator is present next to the radio mast symbol then this would suggest that the CentaurPlus ZW has not been paired correctly on installation.
1 14
10
17
3
11
12
13
9
4 5 6 7 8
2 1615
3
Manual Overrides
BOOST FUNCTION - 1 HOUR TEMPORARY OVERRIDE
The boost facility will allow the user to boost the system which is currently ‘OFF’ for 1 hour. To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The system ON indicator will also be illuminated.
ADVANCE FUNCTION – BRINGS FORWARD THE NEXT ON OR OFF OPERATION The advance facility will allow the user to advance the system to ‘ON’ when currently ‘OFF’
or switch the system ‘OFF’ when currently ‘ON’. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time. The system ON indicator will also be illuminated.
Press BOOST button:
Your system will be boosted for 1 hour
Press ADVANCE button once to move to the next ON/OFF time
At any time during a BOOST period press BOOST again to return to normal programming
To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme
AUTO ALL DAY 24 HRS OFF
AUTO ALL DAY 24 HRS OFF
6:35
6:35
PM
PM
RUN
CLOCK
PROG
RUN
CLOCK
PROG
BOOST
ADVANCE
4
Programme Override Facilities
With the CentaurPlus C17-ZW timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the SELECT button. The options include:
AUTO - Timeswitch follows all programmed ‘ON’ and ‘OFF’ times.
ALL DAY - Timeswitch operates from 1st ‘ON’ time until 3rd ’OFF’, ignoring all
switching times in between.
24hrs - Timeswitch will be constantly ‘ON’.
OFF - Timeswitch will be constantly ‘OFF’, there is the ability to turn off the
heating during the summer without altering the programme times. Boost is still available.
All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user.
The diagram below illustrates how to alter the setting, it assumes that the programme is in the AUTO mode to begin with.
Press SELECT once. Programme goes from AUTO to ALL DAY
Timeswitch will operate from 1st ON until 3rd OFF period
Press SELECT again. Programme goes from ALL DAY to 24 HRS
Timeswitch will be continuously ON
Press SELECT again. Programme goes from 24 HRS to OFF
Timeswitch will be continuously OFF
Press SELECT again. Programme goes from OFF to AUTO
Programme will return to normal ON and OFF times
AUTO ALL DAY 24 HRS OFF
6:35
PM
AUTO ALL DAY 24 HRS OFF
6:35
PM
AUTO ALL DAY 24 HRS OFF
6:35
PM
AUTO ALL DAY 24 HRS OFF
6:35
PM
5
Setting Time of Day and Date
Once the year is set and the ENTER button is pressed the process is complete and the display will return to the run position
Check that the correct time and DAY are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated
Press the set button until the set indicator is next to the ‘clock’ position
Use the + and – buttons to adjust the hour and press ENTER
Use the + and – buttons to adjust the minutes and press ENTER
Use the + and – buttons to set the date and press ENTER
Use the + and – buttons to set the month and press ENTER
Use the + and – buttons to set the year and press ENTER
The CentaurPlus C17-ZW timeswitch has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year.
Resetting the Timeswitch
Electronic equipment can in some circumstances be affected by electrical interference. If the timeswitch display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and SELECT buttons together as shown below.
After initial installation it is advisable, before programming the CentaurPlus ZW for the first time, to reset the unit. Resetting can only be achieved with the power ‘ON’ by pressing the SET and SELECT buttons together. This will return the timeswitch to the factory set default times.
SET
SELECT
Press the SET and SELECT buttons together then release the buttons and the timeswitch will return to preset factory settings
6
Setting the On and Off Times
To alter these settings please proceed as follows:-
The default time settings shown above are preset at the factory
NB. The factory default settings for the 2nd ON/OFF times are both set at 12:00pm (midday) which cancels this ‘ON’ period giving 2 ON/OFF periods for the day. If a midday ‘ON’ period is required set the 2nd ON and OFF times accordingly. If not press ENTER twice.
1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF
6.30AM
8.30AM 12.00P
M
12.00P
M
4.30P
M
10.30P
M
DEFAULT TIME SETTINGS
Press the SET button until SET indicator is next to PROG position
Repeat this process for 2nd and 3rd settings
Use the PLUS and MINUS buttons to select day required and press COPY. ‘IN’ is displayed to confirm the copy. Repeat for other days as required
Press ENTER. Use the plus and minus buttons to select the day required and press ENTER. Set 1st, 2nd and 3rd times as before. To repeat for other days go to 2, to copy go to 1
To transfer to independent times for other days go to 2 or to finish programming press the SET button until the SET indicator is in the RUN position
To finish programming press the SET button until the SET indicator is in the RUN position
Use PLUS and MINUS buttons to adjust day
Use PLUS and MINUS buttons to adjust 1st ON time
Enter the 3rd OFF time and the word COPY is displayed
To set independent times for other days go to 2
To follow the copy route and repeat all programmed times for another day go to 1
Use PLUS and MINUS buttons to adjust 1st OFF time
Press
ENTER
Press
ENTER
Press
ENTER
1
2
7
Relay Operation:
The relay of CENTAURPLUS C17-ZW will operate only when it is operating in an ON schedule and it has received an ON command from the controller (Basic Set or Binary Switch Set). If CENTAURPLUS C17-ZW is operating in an OFF schedule or it has received an OFF command from the controller CENTAURPLUS C17-ZW will turn OFF the relay.
Installation and connection should only be carried out by a suitably qualified person and in accordance with the current edition of the IEE wiring regulations.
WARNING: Isolate mains supply before commencing installation.
An example circuit diagram for a typical combi boiler installation is shown below. This diagram is schematic and should be used for guidance only.
For the installer
N
N
E
L
L 1 2 3 4
For precise terminal connection information please refer to boiler manufacturer's instructions
REMOVE LINK IF REQUIRED
TERMINALS L-2 SHOULD NOT BE LINKED
BOILER LIVE OUT
SWITCHED LIVE
RETURN TO BOILER
MAINS SUPPLY
E
N
L
COMBINATION BOILER TERMINALS
CONTROLLER
Wireless link
CentaurPlus ZW
8
9
Fitting the backplate
Once the backplate has been removed from the packaging please ensure the timeswitch is re-sealed to prevent damage from dust, debris.
The backplate should be fitted with the wiring terminals located at the top and in a position that allows a total clearance of at least 50mm around the unit.
Direct wall mounting
Offer the backplate to the wall in the position where the timeswitch is to be mounted, remembering that the backplate fits to the left hand end of the control. Mark the fixing positions through the slots on the backplate (fixing centres of 60.3mm), drill and plug the wall, then secure the plate in position. The slots in the backplate will compensate for any misalignments of the fixings.
Wiring box mounting
The backplate may be fitted directly onto a single gang steel flush wiring box complying with BS4662, using two M3.5 screws. CentaurPlus controls are suitable for mounting on a flat surface only; they must not be positioned on a surface mounted wall box or on unearthed metal surfaces.
10
Electrical Connections
All necessary electrical connections should now be made. Flush wiring can enter from the rear through the aperture in the backplate. Surface wiring can only enter from beneath the timeswitch and must be securely clamped. The mains supply terminals are intended to be connected to the supply by means of fixed wiring. Recommended cable sizes are
1.00 or 1.5mm.
CentaurPlus timers are double insulted and do not require an earth connection but an earth connection is provided on the backplate for terminating and cable earth connectors. Earth continuity must be maintained and all bare earth connectors must be sleeved. Ensure no earth conductors are left protruding outside the central space enclosed by the backplate.
Internal diagram - C17-ZW
The CentaurPlus ZW has voltage free contacts. A link L-2 is required for mains voltage applications
Rear view of CentaurPlus timeswitch
Battery reserve
The battery must be commissioned prior to fitting the timeswitch to the backplate. This is achieved by the means of a commissioning strip situated in the back of the unit. Pull out the battery commissioning strip at the back of the timeswitch and re-insert the battery; the reserve is now activated. When the timeswitch is running the battery reserve clock display will disappear. This is to prolong the life of the battery.
N L 1 2 3 4
230V 50V COMM OFF ON
1
2
4
3
+
PULL TO REMOVE
1 - RATINGS LABEL
2 - BATTERY
3 - CONNECTOR PINS
4 - PRODUCTION DATE LABEL
11
Fitting the timeswitch
End view of CentaurPlus timer
If surface wiring has been used, remove the knockout/insert from the bottom of the timeswitch to accommodate it.
Loosen the two ‘captive’ retaining screws on the bottom of the backplate. Now fit the timeswitch to the backplate, ensuring the lugs on the backplate engage with the switch.
Swing the bottom of the timeswitch into position ensuring that the connection pins on the back of the unit locate into the terminal slots in the backplate.
Tighten the two captive retaining screws to fix the unit securely.
Then switch on the mains supply.
On completion of the installation please reset the timeswitch as detailed next;
Resetting the timeswitch
On the CentaurPlus press the SET and SELECT buttons together. Then release the buttons and the timer will return to preset factory settings
The preset factory settings are illustrated on page 6.
The unit is now ready to be signed on to a Zwave network.
SET
SELECT
12
Instructions for pairing CentaurPlus ZW
This devices use the latest Z-Wave wireless communication technology to give a reliable wireless link that should not suffer from interference from other nearby devices.
Follow these steps to ensure that the CentaurPlus C17-ZW will communicate satisfactorily with its controller.
Inclusion/Exclusion
If the display against the radio aerial symbol is not present it means the device is not included in any network.
For inclusion, put the controller in inclusion mode and press and hold the ‘Boost’ and ‘Enter’ buttons on the front of the CENTAURPLUS C17-ZW . Once included the indictor next to the radio symbol will appear (solid)
Now check the CentaurPlus ZW is receiving signals from the controller by turning CentaurPlus ZW to an ‘On’ setting with the red indicator light lit. Now send an on/off command from the controller.
N.B. There is a half second delay in switching On and Off on receipt of the commands. There will be an audible ‘click’ from the CentaurPlus ZW when the relay toggles.
For exclusion put the controller in exclusion mode and Press and hold the ‘Boost’ and ‘Enter’ buttons on the front of the CENTAURPLUS C17-ZW until an indicator disappears in its display against the radio aerial symbol.
If the Icon next to the RF symbol is flashing, then the unit has lost communication with the controller, try to move the controller closer.
Press and hold ‘BOOST’ and ‘ENTER’ buttons to ‘SIGN ON’ or ‘PAIR’ the HRT4 ZW thermostat
13
Z-Wave Device Classes Implemented Device Class
Generic BINARY SWITCH
Specific SPECIFIC TYPE NOT USED
Basic ROUTING SLAVE.
Command Classes Description
Manufacturer Specific SECURE CONTROLS UK LTD
Version Provides the version number of the software
Binary Switch Supports SET and GET to control the relay
Basic The Basic Command Class has been mapped to the Binary switch Command Class as follows:
Basic SET Set the Relay Status.
Basic GET Relay State GET.
Basic REPORT Relay State REPORT
Application Status Application Busy Command has been Implemented for the SET command. While CentaurPlus C17-ZW is in a scheduled off period the SET command will be queued and executed when the unit is entering an active state. Application Reject Request Command – Not implemented
Note: All command classes are version 1 unless otherwise stated. Note: The CENTAURPLUS C17-ZW is mains operating device and a routing slave so it will route the RF messages in network.
The device classes supported are given below.
14
General Information
BATTERY
The timeswitch is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life.
SERVICE AND REPAIR
This timeswitch is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE TIMESWITCH section of this user guide shown above. If this fails to resolve the problem please contact your installer, a local heating engineer or a qualified electrician.
15
Timeswitch specification CentaurPlus ZW
Contact Rating 3 (1) Amps 230V AC Contact Type Micro-disconnection changeover Supply 230V AC 50Hz only Class A Software Type 1 Control Case Material Thermoplastic, flame retardant Auto BST/GMT changeover Display Back lit liquid crystal Battery Life 10 months continuous operation (minimum) Displayed Time adjustments 1 minute steps Operating periods per day - 3 per day
(Separate programmers possible for each day of the week) 10 minute steps Override 1 hour boost, 1 hour extension to On period, instant advance Mounting Industry standard 6 terminal plug in wall plate Design Standard EN60730-2-7 IP30 EN300-220 R & TTE Directive EN301-489 Transmitter Frequency 868MHz Voltage free Pollution Degree 2 Operating Temperature Range 0°C to +40°C Dimensions 84mm x 150mm x 29mm Clock 12 hour AM/PM
For further replacement timeswitch exchange information, please see the ‘Programmer Wiring and Replacement Guide’ at www.horstmann.co.uk Use the categories shown under CentaurPlus C11 and C17.
16
Leaflet number P84365 Issue 1
Secure Controls UK Limited
South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP England
Tel: +44 (0) 117 978 8700 / Fax: +44 (0) 117 978 8701 / e-mail: homes@securetogether.com