Beanbag Thermostat
This is a Z-Wave Plus enabled battery-powered
portable controller designed for home heating
system, it act as a room thermostat if used with
Beanbag Receiver.
It is having OLED display to show the ambient
and target (Set-point) temperature, these
parameter and also reported over Z-Wave to
associated nodes.
It can be operated in any Z-Wave network with
other Z-Wave certified devices from other
manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of
vendor to increase reliability of the network.
Operational Modes
Device support Normal and Advance mode, by default device is in normal mode, mode can be switched
by long press of OK button.
Advance mode is designed to perform device setup and network installation and configurations, refer
table Advance Mode for more information.
Inclusion / Exclusion
Inclusion:- Power up device (by pulling out battery strip), start Add node on Z-Wave controller and click
Ok button when device display instructing to click OK button, this will start learn process in device.
Exclusion:- Start Remove node on Z-Wave controller, on thermostat enter in Advance mode, and then
scroll to option “Activate Learn mode”, then click OK button.
Thermostat will display learn outcome on completion of the process.
Add / Remove
On thermostat in advance mode scroll to option “Add device / Remove device”, then click OK button. On
other Z-Wave device start learn process, thermostat will display outcome on completion of the process.
Wakeup from Sleep
On thermostat, click OK button when device screen is off, or in advance mode scroll to option “Enter
listening mode” then click OK button.
1

Include any Z-Wave device into its network
Exclude any Z-Wave device from network
Start Learn process for inclusion / Exclusion from other network
Listen mode for sending Wakeup Notification to wake up node if configured
Broadcast device
Information
Broadcast its Node Information Frame (NIF)
Check
signal
strength (2)
RF signal strength test using power level CC with associated node in Group 2
Action on associated node
May move node, or install repeater node in-between
Must move node, or install repeater node in-between
Perform protocol reset, set thermostat configurations to factory default.
Note: Please use this procedure only when the network primary
controller is missing or otherwise inoperable.
Associate node in group 2 by Classic / Multichannel association, using NIF /
Multichannel capability report from other Z-Wave device (node).
Remove channel
association(2)
Remove associated node from association group 2
View associated
channel ID(2)
Display associated end point (Channel number ) in association group 2
No End point available in association group
End point x ( 1 to 127 ) available in association group
Used to Set / Change boiler fuel type to configure TPI cycle.
View present boiler fuel type.
Lock/unlock
temperature set point
Disable / Enable set-point change using Up/Down buttons.
Shift primary role to the new controller in network
Routing_Sensor_Multilevel
Command Classes
Supported
Manufacturer Specific (V2)
Secure Controls (UK) Manufacturer ID, Device serial number
Provides the version number of the firmware, hardware and supported
Command Classes.
Device Locally reset (v1)
Used to inform lifeline node that the device has been factory reset, and is
leaving the network.
Z-Wave Plus Info (v2)
Z-Wave Plus Version 1
Role Type - ROLE_TYPE_CONTROLLER_PORTABLE_REPORTING
1. Maximum time out for activity is 55 seconds.
2. Operation applicable if node available in association group 2.
SUPPORTED DEVICE AND COMMAND CLASSES
2

Node Type - NODE_TYPE_ZWAVEPLUS_NODE
Installer IconICON_TYPE_SPECIFIC_SENSOR_MULTILEVEL_AIR_TEMPERATURE
User Icon - ICON_TYPE_GENERIC_SENSOR_MULTILEVEL
Wakeup interval step is 60 second.
Minimum wakeup interval is 900 seconds
Maximum wakeup interval is 10 days
Default wakeup interval is 24 hours
Association Group Info (v1)
Profile MSB AGI_PROFILE_GENERAL
Profile LSB AGI_GENERAL_LIFELINE
2 1 Sensor: Air temperature
SENSOR_ MULTILEVEL_
REPORT_TEMPERATURE
Support two groups each can have maximum one node
Low battery Alarm Report
Multilevel Sensor Report
Device Reset Locally
Multilevel Sensor Report
Set point Set
Multi Channel Association
(v2)
Device support single node with One endpoint to association group 2
Configuration (v1)
(Any change from default
configuration, will reduce the
battery life, zero configuration
means that feature is disabled)
Parameter Type
(sequential order)
Delta Temperature
for Association
Group 2
Temperature report
Interval for
association Group 2
Minimum Set Point
temperature
Maximum Set Point
temperature
Delta Temperature
for lifeline Group
Temperature report
Interval for lifeline
group
Example: To configure Delta temperature to 2 °C. The value need to configured in
device is 2/0.1 = 20.
IMPORTANT: Controllers may only allow configuring signed values. In order to set
values in the range 128…255, the value sent in the application shall be equal to
desired value minus 256. For example, to set Delta Temperature to 130, it may be
needed to set a value 130−256=−126.
Measure room temperature to 0.1°C resolution. But report as per its
configuration set.
For network maintenance functionality
Firmware Update Meta
Data (v3)
For providing Over-The-Air firmware upgrades
Thermostat Set point (v3)
Used to directly read and control the current target temperature
3

Can’t able to reach associated node
Wall mounting to fit a single gang wall
box
Thermoplastic, flame retardant HB
Environmental humidity range
980 to 1035 hPa above mean sea level
2 x AA LR6 alkaline, 2700 mAh
100m line of sight in open air
Installation instruction
LED illumination
Technical Specification
4