SECOLink MAS-800 Short User Manual

Page 1
Arming mode “Stay” – AA
žžF-key: for EU countries – , for non EU countries is available .
Via Menu: , [Arming] , [Stay] , [PIN:] , [Parts:] .
A A ENT
ENT A A ENT
ENT ENT ENT
ENT ENT
This arming mode is used to protect a house
. Arming:
, when we are staying at home (inside) and are waiting, that
somebody can come in. Interior zones aren’t protected.After opening the door will beentry delay
Functional keys for quick and comfortable control of the system
Security system SECOLink is supplied with standard (described below) functional keys (F-key) set. It allows by one or two pressings of the keypad keys perform generally using function, avoiding the control of the system via
Functional keys
(F-keys)
System's state LED indication
This key is used for zone review, also for marking the partitions and other elements of the system (for example for marking zone, which'll be bypassed)
pre-alarm
trouble
armed
alarm
A
B
C
F
1
4
7
2
5
8
0
3
6
9
#
CLR
ENT
MAS-800
Pre-alarm indication
Main menu navigation keys
There are 4 partitions in system:
- in the first one there are zones, which are violated
- the third partition is disarmed and hasn’t violated zones,
- the fourth partition is armed in the “Away” mode.
,
- the second partition is armed in the “Night” mode,
Remote control is allowed
by radio remote control unit
Date
Time
Enviroment temperature
(only for KM20T)
There is 1 partition in the system. This partition isn’t armed and there are no zones, which are violated
Arming mode “Away” – A
ž ž ž
F-key: for EU countries – , , for non EU countries is available . PIN code: . via Menu: , [Arming] , [All partitions] , [PIN:] .
A ENT
ENT A ENT
ENT
ENT ENT ENT
ENT
This arming mode is used when you want to protect a premise . After arming, all zones will be protected.After using the door will be entrydelay time for disarming. Arming:
, when nobody will be staying inside
F-key (the name)
F-key
Ways of arming
The system can be armed by three ways: F-key, via Main Menu, entering PIN code. Using F-key, all partitions, which are controlled by User, will be armed. When Arming is activated via Menu, it's necessary to mark the partitions, which will be armed (mark the partitions with or ). When arming is activated by Entering PIN code, it will be armed in “Away” mode.
and confirm with
ENT
Arming mode “Vacation” – AAA
žžF-key: [PIN:], .
Via Menu: , [Arming] , [Vacation] , [PIN:] , [Parts:] .
A A A ENT
ENT
ENT ENT ENT
ENT ENT
This arming mode is used when we are leaving the premise for a long period(e.g. vacations). After arming, all zones will be protected, entry delay is off, alarm will sound upon opening door. Arming :
Only the first partition is armed. This way of arming is available in 2 - storied house,when at night the ground
isn’t used, all sensors of this partition are armed, also there isn’t entry delay for door, so nobody
suppose to enter the house (the second or both partitions can be armed analogously: with A
floor
2 or A12).
Arming:
žžF-key: for EU countries – non EU countries is available .
Via Menu: , [Arming] , [Vacation] , [PIN:] , [Parts:] .
, for
A
1
ENT
ENT A
1
ENT
ENT ENT ENT
ENT ENT
Short user manualIntruder alarm system
Emergency keys
Main Menu. During the installation is available to make individual F-keys, which are maximum fitted for the object’s protection and for the User’s needs. If you press the key, and then the or keys, you can review list of available
F-keys.
F
Maximum Arming for the first partition – A1
(For example for gates)
This key is used for partition review,
also for marking all partitions or
another element
(for example for User selecting)
selecting
Page 2
žžF-key: , [PIN:] :
Via Menu: , [Zone Bypass] , [PIN:] :
B
ENT
ENT
ENT ENT
PIN:
ENT
Forced Arming – F , AAAA
žžF-key: for EU countries – non EU countries is available .
Via Menu: , [Arming] , [Forced Arming] , [PIN:] .
, for
F
ENT
ENT
F
ENT
ENT ENT ENT
ENT
The arming mode, that allows to arm the system when the zones are violated or the sensor is broken. All sensors, which were remained earlier, will be armed. After opening the entry/exit door the system will give entry delay time. Arming:
Arming and disarming of security barrier, “Pre-alarm” mode
ž1 example: , [Arming] , [Vacation] , [PIN:] , [Parts:] .
2 example: , [Arming] , [Away] , [PIN:] , [Parts:]
ž
ENT ENT ENT
ENT ENT
ENT ENT ENT
ENT ENT
This is universal way of arming, which enables to arm selected partition in desired arming mode. In case of partial arming Green LED will blinkslowly.
Arming mode “Night” – C
žžF-key: for EU countries – non EU countries is available .
Via Menu: , [Arming] , [Night] , [PIN:] , [Parts:] .
, for
C ENT
ENT C ENT
ENT ENT ENT
ENT ENT
This arming mode is used The interior zones are left disarmed, if anyone opens door, won’t be the entry delay and the alarmwill sound. This arming mode is effective, when the door and windows are secured by the opening sensors or there are installed glass break detectors. Arming:
when you want to arm the system with the person staying inside of the premise.
Arming the first partition with entry delay on – A1A
žžF-key: for EU countries – non EU countries is available .
Via Menu: [Arming] [Away] [Parts:] .
, for
, , , [PIN:] ,
A
1
A ENT
ENT A
1
A ENT
ENT ENT ENT
ENT ENT
ž Via Menu: , [Prealarm] , [PIN:] , [Parts:] .
ENT ENT
ENT ENT
Microwave or infrared rays based security barriers, also outdoor PIR detectors, which are connected to the system, can be armed by “Pre-alarm” mode. The system will sound an alarm (without sending alarm message to Central Monitoring Station), when someone travers this electrical barrier. The “Pre-alarm” mode can be turned on and turned off the same way, as described below. For the more convenient control of “Pre-alarm” is recommended to create special F-keys (during installation process).
Partial Arming
Bypassing zone – B
If you want to arm the system with zones, which are violated (for example: with opened windows) it’s necessary to determine, that the system bypass these zones. Bypass procedure can be made:
The zone, which you want to bypass is selected with or keys, and is marked the
will be shown on display. Bypass procedure is finishing by the ENT key. The zone is bypassing for
one arming/disarming cycle.
key. If selected zone is
bypassed, the symbol
Zone is
bypassed
Zone isn’t
violated
Zone is
violated
Abort arming
For selecting, also for aborting arm procedure the system SECOLink has the key. If the exit delay is in process and you want to abort arming, pressthe key, enter PIN and confirm it with the key.
CLR
CLR ENT
Arming system with troubles
EU standards unexpect
230V disappearance in AC line, disconnected phone line
because of repair
using of the system, which has troubles. When Yellow LED is on, the arming is impossible in the ways, which were discribed earlier. It is necessary immediately eliminate troubles, also inform CMS and company, which had installed the system.The system detects troubles in own modules, also it detects and other common troubles, like
, battery discharge. In exceptional cases is possible to bypass the troubles for a short time and arm system asusual. It can be done thisway: Press the key once - message about the trouble will be shown on the display, then press key again­Yellow “Trouble” LED starts to blink fast. The blinking duration is seconds, during this time is possible to make usual arming procedure.
30
CLR
CLR
1 example 2 example
Short user manualIntruder alarm system
Only the first partition is armed. This kind of arming is available in , when at night the ground
, all sensors of this partition are armed. When somebody opens doors will be an entry delay.
The second or both partitions can be armed with A . Arming :
2-storied house
floor isn’t used
2A or A12A respectively
trouble
armed
alarm
3 CLR
Page 3
trouble
armed
alarm
3 CLR
Emergency keys
In order to call for a help (the premises must be secured by CMS) press at once two specific keys and hold them at least 1 second. When emergency alarm occurs, siren starts to sound and alarm message will be shown on the keypad display.
Fire alarm . Medical alarm – . Panic alarm .
ž ž ž
+ + +
A 1
B 4
C 7
Disarming by PIN code, when entering the premise
After opening the door, which are protected, the system begins to count the entry delay. During this time it is necessary to enter PIN code and confirm by pressing the key. All partitions, which are controlled by User,will be disarmed.
ENT
Disarming by PIN code, when staying in protected premise
When all partitions are armed and the entry door weren’t opened, after entering PIN, all partitions, which are controlled by User, will be disarmed. Disarming: . When part of partitions are armed and the entry door weren’t opened, after entering PIN it is necessary to make decision either to arm disarmedpartitions or to disarm armed ones. Full disarming : , [Disarming] , [All partitions] . Partial disarming: , [Disarming] , [Selected parti] , [Parts:] .
ENT
ENT ENT ENT
ENT ENT ENT ENT
Disarming when staying in protected premise – BB or F0
Nevertheless, are there all partitions armed or not, all partitions, which are controlled by User, will be disarmed. Disarming :
F-key: or
ž .
F 0
ENT
ENT
B B
ENT
ENT
The first partition disarming, when staying in premise - B1
Nevertheless, are there all partitions armed or not, the first partition, which is controlled by User, will be disarmed. Disarming:
F-key: .
The second partition can bedisarmed with
ž
.
, both partitions with
B
1
ENT
ENT
B
2222
B
1
2222
Event log review – F30, F31
All events, which are concerned with protected premises and status of the system, are stored in the event log. Reviewing event log:
F-key: (ALARMS events), (FAULTS events). Via Menu: [Event Log] , [Alarm Event] , [PIN:] .
To display time or date event press the key the , .key
ž ž
, next event is selected
F
3
0
ENT F
3 1
ENT
ENT ENT ENT
ENT
If an alarm has occured, on the display appears message “Alarm
There are 2 ways toclear alarm and turn off red LED:
way – pressing the
After performed alarm clearing action siren stops to sound
– entering PIN code. After performed alarm clearing action siren stops to sound, alarm LED goesoff, the system will be disarmed if it was armed beforeentering PIN code. When all partitions, which are controlled by User, are disarmed, it's not recommended to use PIN for alarm clearing, because is possible casual arming.
!!!” with an explanation, what reason caused it. Alarm LED is turned on, the siren starts to sound and report about alarm is sending to CMS or to the User.
2 way
žž1 .
, alarm LED goes off, the system status remains the same as was before alarm. If the system has smoke detector and alarm was caused by smoke, which was raised by domestic reasons, the system will start alarm, nevertheless it was armed or disarmed. The only way to clear alarm is possible by bypassing of smoke detector (see “Bypassing zone – B”).2 page,
CLR
ENT
Alarm clearing
Electronic notebook (memo) review - F09
All important contact information
1 record 2 record 3 record 4record 5 record
1 record] 2 record] 3 record 4 record 5record
(phone No, e-mail) Installer can write out on keypad. Review: F-key: , [ ] , [ ] , [ ] , [ ] , [ ] . Via Menu: [memo ,[ , [ , [ ] , [ ] , [ ] .
ž ž
F 0
9
ENT
ENT ENT
pre-alarm trouble
armed
alarm
Ways of disarming
Disarming can be done by three ways: F-key, entering PIN code, Via Main Menu. Using F-key or entering PIN, all partitions, which are controlled by User, will be disarmed. After disarming via Menu it’s necessary to unmark the partition, which we don't want to protect. The partition, which will be disarmed, is denoted the or keys and this action is confirmed by pressing the key.
ENT
Short user manualIntruder alarm system
Page 4
žžF-key: , [Enable Service: User PIN:] , [ServicePIN:].
Via menu: , [Service mode] , [Enable Service: User PIN:] , [ServicePIN:].
F
3 3
ENT
ENT
ENT
ENT
ENT
perspėjimas gedimas
apsauga
aliarmas
Permission to make changes of the system (service mode entry) F33
For security reasons Installer will have permission to make changes of the system setting only after User approves it by entering his PIN .
pre-alarm trouble
armed
alarm
Chime mode
“Chime” function is used to inform User with the sound or light signal (LCD display, keypad keys) about opening of entry/exit door or violation of other selected zone. From which zone “chime” will be activated you can set by pressing the key on selected zone. The “chime”zone will be marked as .
Via Menu: , [Options:] , , [Chime] , , .
ž
ENT ENT ENT
ENT ENT
pre-alarm trouble
armed
alarm
MAS-800
Keypad display and keys backlight changing F10
pre-alarm trouble
armed
alarm
MAS-800
User has possibility to change contrast and backlight intensity of keypad LCD display, also he can select conditions, when keypad keys will be illuminated. Default settings - button’s illuminating starts up after pressing the button or when occurs entry delay or alarm trigger. For illuminating buttons all the time, it is necessary to perform such actions:
F-key: , [Keypad Settings:] , [Light] , [LCD ] , [Changed]
.
Via Menu: , [Options:] , [Keypad settings] , [PIN:] , [Light] ,
[LCD ] , [Changed] .
ž
ž
&keypad
& keypad
F
1
0
ENT
ENT ENT ENT CLR
CLR CLR
ENT ENT ENT
ENT ENT
ENT CLR CLR CLR
pre-alarm trouble
armed
alarm
MAS-800
Temperature correction o – F11n keypad display (only KM20T)
If the keypad shows an incorrect enviroment temperature, it is recommended to make temperature correction, which can be done by entering value of temperature, measured with domestic thermometers. The correction can be made Via Menu: , [Setting] , [Temperature] ,
[Temper.correction.] , , (enter temperature value) .
ENT ENT ENT
ENT
ENT ENT
Activated User PIN code changing F20
The manufacturer provides the system with 4-digit number default PIN, which are suited to system’s User count number. For example: the default PIN for the will befirst User 0001, for the second User - 0002 and etc. After installation it is strongly recommended to change default PIN.
žžF-key: , [Change PIN:] , [New PIN:] , [Repeat:] , [Changed].
Via Menu: , [Options] , [Users] , , [Change PIN:] , [New PIN:]
, [Repeat:] , [Changed].
F
2 0
ENT
ENT
ENT
ENT
ENT ENT ENT ENT
ENT
ENT
ENT
pre-alarm trouble
armed
alarm
žžF-key: , .
Via Menu: , [Tests] , [Burg. Zone Tes] , .
F
2222 2222
ENT
ENT
ENT ENT ENT
ENT
Sensor operation testing, testing zones F22
Testing zone
is not violated
Testing zone
is violated
Zones, which were violated ( , are checking by pressing the key, test finishes by pressing#)
CLR
Setting Date and time F21
žžF-key: , [Date and Time:] , (enter date and time) .
Via Menu: , [Options] , , [Date and Time] , (enter date and time) .
F
2
1
ENT
ENT ENT
ENT ENT ENT
ENT ENT
Activated Users’ review F23
After system installation is recommended to review, how many Users can control the security system:
F-key: , , [mode], . Via Menu: , [setting] , [Users] , [edit User.] , , [mode],
. LCD display will show User number (for example U : Enabled or Disabled. All Users , who have mode “Enabled” cancontrol system or it’s partitions.
ž ž
01) and mode
F
2 3
ENT
ENT
ENT ENT ENT ENT
ENT
pre-alarm trouble
armed
alarm
MAS-800
PIN: ?
Short user manualIntruder alarm system
It is recommended to do sensor work test at least one time per month. Duringa test it is necessary to make a violation of zone, it means to open door or windows, which have magnetic contacts, or to simulate movement near the motion sensor. Glass break detector can be testedby hard clapping hands. Testing:
The example: The User of the system has a PIN
, [Change PIN:] , [New PIN:] ,
[Repeat:] [Changed].
1234. When he feels, that PIN isn’t secure, he can
change it by pressing sequence of keys 1234 3762
3762
F
2 0
ENT ENT ENT
ENT
MAS-800
MAS-800
System compliance and warranty
The system is made in Lithuania, warranty term is 24 months. The manufacturer – company "Kodinis Raktas" declares, that product “SECOLink” complies withessential EU directive and EU standard EN 50131-1. See manufacturer’s web site: www.kodinis.lt for complete text ofdeclaration.