SECOLink KM24, KM24A, KM24G Short User Manual

Page 1
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
SECOLINK KM24, KM24A, and KM24G are user-friendly new concept keypads. Large graphic display with helpful texts and backlit keys simplify the use of an alarm system. There are options to customize main screen information and change contrast or backlight intensity of LCD and illumination of keypad keys. User can easily follow the blinking keys as prompts to operate the system without any commands needed to memorize. Arming, disarming, and zone bypassing is simple and can be done intuitively . The main keypad functions and primary display view are shown in the figure below.
Date
Partition status
System status
Info bar (KM24G)
Arm
Disarm
14:1510/02 +25°C
READY TO ARM
1st Floor
Bedroom +25°C Rad.Stat.: perfect Living room +24°C Rad.Stat.: perfect
2nd Floor
Temperature (KM24A, KM24G)
Time
Zones, partitions Sound settings
System information
Return to upper menu level, alarm/ trouble review and clear
Zone bypass
Navigation keys
Emergency keys
Entering selected menu item, value entry , selection confirmation
Functional key
This key is used for partition review, also for marking all partitions, or selecting another element
This key is used for zone review, also for marking the partitions and other elements of the system
Ways of arming
The system can be armed in two ways: with a special key, or by entering a PIN code (symbol is used to prompt you to enter your PIN code). When Arming is activated using the key, it is necessary to mark the p artitions (areas), which will be armed (use keys ... or to mark a particular partition (area), or use to mark all partitions and proceed by pressing to confirm the selections). If arming is activated by entering a PIN code, your system will be armed in Away mode.
!
!
!
!
4
4
4
4
1111
####
GHI
GHI
GHI
GHI
ENT
Away arming mode
Use this mode for premises protection when no one will be staying inside. When armed in Away mode, all zones will be secure and the system will sound an alarm if a protected zone is violated. User must disarm the system within the entry delay period or an alarm will occur. There are three ways to arm your security system's Away arming mode:
for EU countries – , Away , .
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
for non-EU countries – , Away .
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
PIN code: .
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
ENT
Arming All To Exit
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
Press the key.
ENT
Arming To Exit
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
Press the key.
Arm
ÜÜÜÜ
Enter PIN
partitions 30
ÜÜÜÜ
Enter PIN
ENT
Enter your PIN code . Leave the premises.
seconds
30
seconds
ENT
Leave the premises.
To Exit
30
seconds
Enter your PIN code . PIN code entry. Leave the premises.
Page 1
Page 2
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
Stay arming mode
Use this mode when you are staying at home, but expect someone to use the entrance door later. Interior zones will not be protected and you may freely move throughout the premises. Late arrivals can enter through the designated entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur. There are two ways to arm your security system's Stay arming mode:
for EU countries – , Stay , . for non-EU countries – , Stay .
ENT
ENT
Max Away arming mode
Use this mode when no one will be staying on the premises for a long period of time (e.g., vacations). Close all protected perimeter windows and doors before arming. When armed in Max Away mode, all zones will be secure, entry delay will turn off, and the system will sound an alarm if a protected zone is violated. There are two ways to arm your security system's Max Away arming mode:
for EU countries – , Max Away , . for non-EU countries – , Max Away .
ENT
ENT
Night arming mode
Use this arming mode when you are staying inside the premises and require increased security . Interior zones are disarmed and you may freely move throughout the premises. In the event of someone opening the door there will not be an entry delay and the alarm will sound. This arming mode is effective when doors and windows are secured with opening sensors, or glass break detectors are installed. There are two ways to arm Night Arming mode:
for EU countries – , Night , . for non-EU countries – , Night .
ENT
ENT
Partial Arming
Partitions allows you to break up a large area into smaller sections. Use this arming mode to arm certain areas of the premises while leaving other areas disarmed, or to limit other user’s access in specific areas. For example: an alarm system is installed in a two-story house. During night time the ground floor isn't being used and all sensors of this partition are armed. There will be an entry delay in the event of someone opening the door . Below is an example of how to arm a first partition (one of two) in Away mode.
ENT
for EU countries – , Away , , .
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
for non-EU countries – , Away , , .
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
1111
Arming
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
Press the key.
1111
ENT
1111
Arming
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
Press the key.
1111
Arming and disarming of security barrier, “Pre-Alarm” mode
Microwave or infrared rays based security barriers, outdoor PIR detectors, which are connected to the system, can be armed by Pre-alarm mode. In the event of someone crossing this electrical barrier the system will sound an alarm without sending an alarm message to Central Monitoring Station. The Pre-alarm mode can be turned on and off the same way . Please follow the instructions below:
ENTENTENTENT
, Pre-Alarm , , .
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
1111
SOUNDS
Pre-Alarm
Press [ENT] to confirm Press [ ] to select mode Press [1]..[4] to select part.
Press the key.
1111
Partitions 1 # 1st Floor 2 2nd Floor
Press the key.
Partitions 1 # 1st Floor 2 2nd Floor
Press the key.
Partitions 1 X 1st Floor 2 2nd Floor
Press the key.
Arm
ÜÜÜÜ
Enter PIN
ENT
Enter your PIN code . Leave the premises.
To Exit
30
seconds
To Exit
30
seconds
ENT
Leave the premises.
10/02 X . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
ENT
Pre-alarm is turned on in
1st partition.
Page 2
Page 3
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
Bypassing zone
Bypassing a zone allows you to leave a door or window open while arming the rest of your security system. There are two different types of bypass: temporal or permanent. Temporal bypass is used for a one time arming and
disarming cycle. Permanent bypass is used until the user unbypasses the zone. Enter the zone number you would like to
bypass. THIS MUST BE A TWO DIGIT NUMBER. The zone will be marked as " ". To bypass the zone for a long time (permanent) the last number should be pressed and held for 2 sec. A zone will be marked as " ". Press when all zones are marked. The same actions can be performed by choosing the zone with or keys and by marking a chosen zone with the
####
key (short press - temporal, long - permanent). To bypass follow the step s below:
!
!
!
!
BY
BY
BY
BY
B
B
B
B
, Zone bypass, , ... or , and ,
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
!
!
!
!
BY
BY
BY
BY
B
B
B
Press the key.
B
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
!
!
!
!
BY
BY
BY
BY
B
B
B
Press the key.
B
9
0000
WXYZ9WXYZ9WXYZ9WXYZ
Zone
Bypass
ÜÜÜÜ
Enter PIN
Enter your PIN code .
Zone
Bypass
ÜÜÜÜ
Enter PIN
Enter your PIN code .
ENTENTENTENT
####
Zones 1 !Entry Door 2 Hallway
3 Living room 4 Be droom 5 K itchen 6 Bathroom
Zone named Entry Door is
violated (!). To bypass
press the key.
Zones 1 ! Entry Door 2 Hallway
3 Living room 4 Be droom 5 K itchen 6 Bathroom
####
Zone named Entry Door is
violated (!). Press the key
and hold it for 2 seconds.
####
Zones 1 xEntry Door 2 Hallway
3 Living room 4 Be droom 5 K itchen 6 Bathroom
Zone is bypassed
temporarily.
Press the key.
Zones 1 X Entry Door 2 Hallway
3 Living room 4 Be droom 5 K itchen 6 Bathroom
Zone is bypassed
permanently.
Press the key.
ENTENTENTENT
ENTENTENTENT
ENTENTENTENT
10/02 . . 25°C 14:02
BYP ASSED
Entry Door
10/ 02 . . 25°C 14:02
BYP ASSED
Entry Door
Abort arming
CLRCLRCLRCLR
Clear key is used for selecting and aborting procedures. For example, if exit delay is in process and you want to abort arming, press the key and enter your PIN code.
CLR
Arming system with troubles
EU standards do not allow the use of a troubled security system. Green LED light of the key will turn on and arming of the system with previously described ways will not be possible. It is necessary to immediately eliminate
system troubles, inform CMS, and the company that had installed your system. The system detect s troubles of its own modules as well as other common problems such as 230V disappearance in AC line, a disconnected phone line due to repairs, or a battery discharge. In exceptional cases it is possible to bypass certain troubles for a short period of time and arm the system as usual. T o arm a system with troubles please do the following: Press the key once and a message describing system troubles will be shown on the display . Press again and the Green
CLRCLRCLRCLR CLRCLRCLRCLR
LED light will start to blink rapidly . Blinking duration is 30 seconds and during this time it is possible to activate Arming of your system as usual.
CLRCLRCLRCLR
Emergency keys
To activate an emergency function press at once two event specific keys listed below and hold it for at least 1
second. Premises must be secured by CMS for these functions to activate. An audible emergency loud siren will
occur showing a related message on the keypad screen.
Fire alarm: + .
Medical alarm: + . Panic alarm: + .
AAAA 1111
!
!
!
!
BY
BY
BY
BY
B
B
B
B
CCCC
!
!
!
!
4
4
4
4
GHI
GHI
GHI
GHI
7
PQRS7PQRS7PQRS7PQRS
Ways of disarming
Disarming can be done in two ways: with a special key or by entering a PIN code. User has an option to disarm all or selected partitions when disarming is activated with the key. For partial disarming it's necessary to unmark the partitions
which will be disarmed (unmark the partitions by pressing ... keys or select partitions by pressing , keys and unmark/mark by pressing , or keys). All partitions which are controlled by the user will be disarmed when disarming is
####
activated by entering a PIN code.
!
!
!
!
4
4
4
4
1111
GHI
GHI
GHI
GHI
To Disarm the System Using Your PIN Code Upon Entering the Premise
Entry delay gives you time to disarm the system when you enter through the designated entrance door. You must
disarm the system before entry delay period ends to avoid an alarm occurrence. There are two ways to disarm the
system using your PIN code:
, Disarming, , . PIN code: .
ENTENTENTENT
Page 3
Page 4
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
Partial disarming
Partial disarming is used when you want to disarm certain areas while leaving other areas armed, or to limit access
to certain areas to other users. Below is an example explaining how to disarm a first partition of two.
, Disarming, ... , , .
Entry Delay
30
seconds
Press the key. Press the key.
!
!
!
!
4
4
4
4
1111
ENTENTENTENT
GHI
GHI
GHI
GHI
Disarming
All partitions
Press [ENT] to disarm Press [1]..[4] to select part.
1111
Partitions 1 1st Floor 2 2nd Floor #
Press the key.
ENT
10/02 . # 25°C 14:02
Disarm
ÜÜÜÜ
Enter PIN
Armed
2nd Floor
Enter your PIN code . First partition is disarmed,
second partition remains armed.
Alarm clearing
During an alarm the keypad screen will display a message “Alarm!!!” with an explanation and reasons that caused it.
Red LED light of the key will turn on, the siren will start to sound aloud, and a report about the alarm will be sent to
CMS or (and) the user. There are two ways to clear the alarm and turn off the red colored LED light.
CLRCLRCLRCLR
, - this type of clearing will stop the siren sound, turn off the red LED light, and the system will return to the prior pre-alarm status. The system will cause an alarm if the system has a smoke detector and an alarm was caused by smoke from domestic reasons, whether it was armed or disarmed. It is possible to clear this type of alarm by bypassing the smoke detector (see page 3, "Bypassing zone - B").
- this type of clearing will stop the siren sound, turn off the red LED light, and the system will be disarmed, even if it was armed previously by entering the PIN code. It is not recommended to use a PIN code for alarm clearing when all partitions (areas) controlled by the user are disarmed due to a possible casual arming.
CLRCLRCLRCLR
Event log review
All events related to protected premises and statuses of the system are stored in the event log. This log will display all events chronologically and includes information, such as types of alarms, troubles or breakages, control events, and more. Use and keys for navigation and viewing next or previous events in the event log.
ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Event Log , Alarm Events , ;
ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Event Log , Trouble Events , .
Sensor operation testing, testing zones
It is recommended to perform sensor operating testing at least once per month. During testing it will be necessary to make some type of violation in order to check the functionality of available sensors. For example, opening a door or windows with magnetic contacts, stimulating movement near the motion sensors, or by hard clapping of hands to test the glass break detectors.
ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Test , Burglary zone test , .
10/02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
ENTENTENTENT
2 Test 2 Fire zone test
4 Technical information
Press , then .
ENTENTENTENT
Press the key.
ENTENTENTENT
Violated zones (#) can be checked by pressing and keys. To end testing press .
ZonesMain Menu Test Zones 1 Entry Door1 Settings 1 Burglary zone test 1 # Entry Door 2 Hallway 2 Hallway
3 Living room3 Event Log 3 Send test report 4 Be droom4 Contr ols 4 Bed room 5 K itchen5 Service Mode 5 K itchen 6 Bathroom 6 Bathroom
Testing zone is not
violated.
ENTENTENTENT
Permission to make system changes (service mode entry)
An installer will have permission to make system changes settings only after a user approves it by entering a PIN code for security reasons. There are two ways to allow the installer to begin system changes:
ENTENTENTENT ENTENTENTENT
, Service Mode , . , .
ENTENTENTENT
3 Living room
Testing zone is violated
(passed test).
Change activated user's PIN code
SECOLINK manufacturer will provide a 4-digit PIN code of the system which is generated in a sequential order, unique to each user, and is related to his/her number in the system. For example, first user’s default PIN code will be 0001, second user’s default PIN code will be 0002, and so on. It is strongly recommended to change your default PIN code in one of these two ways:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Users , Change PIN , , New PIN:, enter new PIN, Repeat:, repeat the new PIN, Changed.
, , , New PIN:, enter new PIN, Repeat:, repeat the new PIN, Changed. The factory default PIN should be used temporary and changed as soon as possible to new one. It is recommended to change old PIN to new one avoiding the PIN that could be used as default for other users (default PIN range 0000 to 0063). It
Page 4
ENTENTENTENT
Page 5
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
is not recommended to use PIN codes that contain two or more same digits (e.g. 1 11 1 or 1212) or consist of consecutive digits (e.g. 3456). The keypad will inform the user that the PIN code change is necessary , if the PIN code is known/reconized to other user. Using an invalid PIN code three times may: trigger an alarm and block the keypad for 90 seconds.
Review all activated users
It is recommended to review how many users can control the system after an installation. To view activated users:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Users , Edit Users , , ... .
LCD screen will display a user’s number (e.g., U01) and status (e.g., Enabled or Disabled). All users with an
Enabled status can control the system or its partitions (areas).
Chime mode
This feature can be used only while the intruder alarm system is disarmed. Your system can be set to alert you by
sound or lighting of the LCD display and keys when doors or windows are being opened, or during any violation of
the selected zone. T o select which zone will feature a Chime function press the key on a selected zone which will
####
then be marked by . Press the key to change Chime melody (symbols , could appear). T o enable this function
please do the following:
, , Chime , ... or and , .
ENTENTENTENT
9
0000
WXYZ9WXYZ9WXYZ9WXYZ
ENTENTENTENT
####
Date and time settings
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Date and Time , , (enter date and time), .
Date Format
Two different date formats are available in the system: Year-Month-Day (YYYY-MM-DD) or Day/Month/Year
(DD/MM/YYYY). T o change date format:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Date Format , .
Show Date and Time
Date and Time can be hidden if it is not needed to be displayed on keyp ad’s LCD screen. This can be achieved by:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Show Date&Time , , .
Prompts to change date and time
The keypad will automatically show prompts to change date and time after each system power up. This prompt can
be disabled via the menu if it is not needed.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Prompt Change Time , , .
Latin Cyrillic Greek Baltic European
Character Set
Different language character sets allow the user to enter a partition, module, user or zone names using those
characters. This can be achieved by:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Character Set , , .
Show status icons
The keypad has an icon set to represent a different status in each partition. Available icons:
– partition is armed in Stay mode;
– partition is armed in Night mode;
– partition is armed in Max Away mode; The keypad shows status icons by default. This setting can be changed in the menu as follows:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Show Status Icons , , .
– partition is armed in Away mode;Pre-Alarm mode is turned On; – partition is disarmed”;
zone is violated.
Show temperature (KM24A, KM24G)
KM24A and KM24G keypads have a temperature sensor that shows on screen the value of measured temperature
by default. This setting can be changed in the menu as follows:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , Show T emperature , , .
Correction of temperature displayed on the keypad (KM24A, KM24G)
If the keypad shows an incorrect environment temperature it is recommended to make temperature corrections. It
can be done by entering a value of the temperature measured with domestic thermometers. The correction can be
made in the menu as follows:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , T emperature , Correction , , (enter temperature value), .
Page 5
Page 6
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Trouble memory
The keypad has an option to inform a user about system troubles, which can also be seen by a green flashing key .
It will not show trouble memory by default and if it is necessary to view it, follow the steps described below:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , ... Use Trouble memory , , .
Hide troubles
T o arm the system in a usual way is impossible when the key is steady green. The user must press twice to arm
the system. The keypad will hide the trouble and the key will start to blink rapidly . Within 30 seconds allocated time
it will be possible to arm the system in a usual way. To permanently hide system trouble and to avoid previously
described arming procedure, it is recommended to change settings in the menu as described below:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface Settings , , ... , Hide Troubles , , .
CLRCLRCLRCLR CLRCLRCLRCLR
CLRCLRCLRCLR
Short user manualIntruder alarm system
CLRCLRCLRCLR
PIN
code is entered. The user must press the key after the last not fixed PIN code digit is entered. PIN code length can be changed in the menu as follows:
, Settings , Keypad Settings , Interface Settings , , ... PIN Length , , .
User has an option to choose the length of the PIN code. The following options are available: Fixed 4 digits, Fixed 5
digits, Fixed 7 digits, and Not fixed. The keypad automatically presses the key after the last digit of the fixed PIN
ENTENTENTENT
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
ENTENTENTENT
LCD display brightness and contrast
PIN length
The brightness and contrast of LCD display can be modified to correspond to premises lighting conditions and user
needs. These settings can be modified in the menu as follows:
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , ... LCD brightness, , .
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , ... Contrast, , .
Backlight modes of LCD display and keypad keys
V arious settings of LCD screen and keypad backlight allow the user to customize the illumination to match different
environments. For example, LCD backlight can be turned on at all times in places where it is necessary to always see the status of the system, or the keypad can be illuminated after any key is pressed or zone is being violated. A vailable settings of LCD display and keypad backlight are as follows: Always – backlight is always ON; By zone - backlight is turned
ON, when at least one of the following events occurs: an entry/exit delay is in progress; an alarm is triggered; either a Chime zone or a zone marked with "+" sign in the "Events from zones" list is violated; and any of the keypad keys is pressed.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , LCD Backlight , , .
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , Keypad backlight , , .
Status LEDs
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
Colored backlight of , , , and keypad keys represents system status or prompts and can be customized to
match different situations. Available settings: Off; Always – status LEDs are always visible; By zone – status LEDs
are visible when at least one of the following events occur: an entry/exit delay is in progress; an alarm is triggered; either a “chime” zone or a zone marked by "+" sign in the Events from zones list is violated; or any keypad key is being pressed.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , Status LEDs , , .
B
key LED
Backlight of the key can be customized to match different environments or situations that occur. Available
settings: Off - the key Green LED is always Off; Prompt - the key Green LED blinks when the system is ready to be armed; Armed - the key Green LED is steady On when the system is armed; Armed and Prompt – the key Green LED is steady On when the system is armed. When the system is ready to be armed, the key LED blinks.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , [ ] key LED , , .
key LED
Backlight of the key can be customized to match different situations that occur . Available settings: Off - the key
LED is allways Of f; Prompt – the key LED blinks when the system is armed and is ready to be disarmed.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , [ ] key LED , , .
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
B
key LED
!
Backlight of the key can be customized to match different situations that occur . Available settings:Off – the key
LED is allways Off; Not Ready – the key LED blinks, if there are violated zones; Zone Bypass Status – the key LED is ON when there are bypassed zones.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , [B] key LED , , .
Page 6
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
B
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
B
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
B
!
!
!
!
!
!
!
!
BY
BY
BY
BY
BY
BY
BY
BY
B
B
B
B
B
B
B
B
Page 7
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
key LED
Backlight of the key can be customized to match different situations that occur . Available settings: Off – the key
LED is always Off ; Pre-Alarm status – the key LED is steady On when the partition is secured with Pre-alarm
mode On.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , ... [ ] key LED , , .
Events from zones
This menu is visible if the setting By zone is used for controlling the backlight of the keypad. In this menu zones work
as a trigger to turn on the backlight of LCD and/or keypad keys should be marked with "+" sign. The key is used to mark/unmark the zone.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , ... Events from zones , , .
################
################ ################
Entry/exit sounds
In this menu it is possible to turn off entry/exit sound countdown on certain keypads where it is not needed, for
example, in the bedroom. The key is used to mark/unmark the partition.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Light & Indication , , ... Entry/Exit sounds , , .
################
################ ################
ENTENTENTENT
Help texts
The keypad is equipped with a special key and its backlight blinks if there is some additional information. T o find
information about how to manage the system or a problem, press the key .
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
Arming
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
????????
The key will start to blink. It means that a help text is available for this menu.
????????
Press key to read the help text.
????????
????????
Use this mode for premises Press [CLR] to exit. protection when no one will be staying inside. All zones will be protected after arming. There will be an entry delay after using a door.
Press or key to
Press to exit.
navigate (if there are
additional text).
Arming
Away
Press [ENT] to arm Press [ ] to select mode Press [1]..[4] to select part.
CLRCLRCLRCLRCLRCLRCLRCLR
Arming mode Away.
ENTENTENTENT
Info bar (KM24G)
KM24G keypad has a two line information bar at the bottom of the LCD screen. It displays information including the
alarm memory, measured temperature by SECOLINK BP1 or BT1 wireless sensors, the statistics of communication between SECOLINK wireless sensor and a receiver, PGM output status (On/Off), GSM signal strength, messages from modules, and etc. The information will rotate by appearing on the LCD screen every 3 seconds if there are more than two lines of information text. Use the key to expand/collapse the bar if it is desired to view all the information at once.
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Info bar is not enabled.
Interface settings 7 Show info bar
Show Alarms Show Modules Mess. Show WL Zone Temp. Show PGM status Show Tech. Info
Select information which
will be seen in the
information bar.
ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Keypad Settings , Interface settings , , ... Show Info Bar , Yes , Show Alarms , Yes .
ENTENTENTENT ENTENTENTENT
10/ 02 . . 25°C 14:02 10/ 02 . . 25°C 14:02
Yes
Yes
READY TO ARM READY TO ARM
No Yes Yes
10/02/2015 13:12 Burglar alarm, 1st Floor 10/02/2015 13:12 Burglar alarm, 1st Floor
Yes
10/02/2015 13:12 Burglar alarm, 2nd Floor 10/02/2015 13:12 Burglar alarm, 2nd Floor
1st Floor 1st Floor
2nd Floor 2nd Floor
Press to expand the
info bar.
10/02/2015 13:12 Burglar alarm, 1st Floor 10/02/2015 13:12 Burglar alarm, 2nd Floor
Bedroom +25°C Living room +24°C SERIAL Reporting Enabled GPRS Reporting Enabled GSM signal strength
Press to collapse the
info bar.
System information
System summary, technical, distributor and installer information can be found by pressing the key when the keypad is displaying the main view . Choose the corresponding menu and press .
10/ 02 . . 25°C 14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
????????
ENTENTENTENT
System
Summary
Press [ENT] to confirm Press [ENT] to confirm Press [ENT] to confirm Press [?] for next settings Press [?] for next settings Press [?] for next settings
Press the key.
ENTENTENTENT
System Summary
BI: 1254369872 Modules 10
0. P64 v.0.06b
1. KM24G v.3.018
2. KM24G v.3.018
3. KM24G v.3.018
Press or to
navigate. Press to exit.
CLRCLRCLRCLRCLRCLRCLRCLR
System
Summary
????????
Press for next
information menu.
Distributor
????
Page 7
Page 8
Secolink Pro
SECOLINK PRO
app on iPhone
App Store
SECOLINK PRO
app on Google
play
KM24, KM24A, KM24G keypadKM24, KM24A, KM24G keypad
Short user manualIntruder alarm system
Communication and messaging (GSVx or VIDNET module must be installed)
This menu allows the user to add phone numbers to receive SMS and call notifications.
Number – phone number must be entered in the international format, "+" sign is added automatically. Smartphone – in this menu the user may specify the SECOLINK PRO application that is used to control the
system. Possible setting options are described below:
No – SECOLINK PRO application is not used. Android – SECOLINK PRO application for Android OS is used. Iphone – SECOLINK PRO application for Apple iOS (iPhone) is used.
Push notifications – a message or an alert delivered by a centralized server to endpoint devices. This
setting is mandatory for iPhone SECOLINK PRO application users who paid for this additional functionality . This communication uses data service and charges may apply .
SMS when armed - SMS notification that the system is armed. SMS when disarmed - SMS notification that the system is disarmed. SMS when alarming – SMS notification in the event of a triggered alarm. Call when alarming – notification via a phone call in the event of a triggered alarm (GSVx only). Incoming
call must be acknowledged either by pressing 0# or by entering PIN#. Mandatory call – notification via a phone call in the event of a triggered alarm (GSVx only). Mandatory call differs from Call when alarming setting by enabling the user to receive a call even if another user in the list acknowledged the call by pressing 0# or by entering the PIN#.
SMS for troubles – SMS notification when the system has any troubles (e.g. battery low). T esting SMS – test notifications via SMS.
ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , Cell phones (GSM) , .
System control via TCP/IP (GSVU, GSV6U, LAN800 or VIDNET must be installed)
ALARMSERVER.NET is simply a service platform that keeps in sync end user devices which have the SECOLINK PRO app installed with the alarm system. Status (armed/disarmed, alarms, troubles), temperature in premises (measured by temperature sensors BT1, BP1, or keypads), and video recordings made by VIDNET can all be monitored using the service. This communication uses data service and charges may apply .
1 Registration on server 1 Registration on server
6 Reporting 6 Reporting
Alarmserver.net menu Reporting settings. Registering on
Reporting Privacy settings 1 Periodic test 2 Technical info 2 Report zone names 3 Every event 3 Save event log 4 Event log 5 TCP control
Disabled
Enabled
1 Report user names
Yes
No
Yes
YesEvery 10 min Yes
Privacy settings. Registration completed.
ALARMSERVER.NET.
Registration on server – this menu is used to register your intruder alarm system on ALARMSER VER.NET and to send any settings related to communication. It is mandatory to register your system with a server, if SECOLINK PRO application will be used to control the system via TCP/IP. Registration should be done when all below mentioned settings are programmed. After a successful registration go to www.alarmserver.net to create a free account. Important! The registration on server process should be repeated if any settings described below are changed.
Reporting – in this menu the user can change settings for reports on ALARMSER VER.NET .
Every event – to view present status of the system, all new generated events (e.g. arming/disarming, alarms) should be
sent to ALARMSER VER.NET . This communication uses data service and charges may apply.
TCP control this setting must be enabled, if SECOLINK PRO application will be used to control the system via TCP/IP.
Module will have a keep-alive connection with a server to ensure real - time control.
Privacy settings – in this menu the user can change privacy settings.
Report user names – selecting an option Yes will allow the system to send user names to ALARMSER VER.NET, which
can be viewed in SECOLINK PRO application. The application will show default system names such as User 01, User 02, if the user will select an option No.
Report zone names selecting an option Yes will allow the system to send the names of zones, partitions and other information (except users names) to ALARMSERVER.NET, which can be viewed in SECOLINK PRO application. The application will show default zone names such as Zone 01, Zone 02, if the user will select an option No.
Save event log selecting an option Yes will allow the user to view the saved system event log in the application. Event log will not be seen with an option No.
ENTENTENTENT ENTENTENTENT ENTENTENTENT
, Settings , ... www.alarmserver.net, .
Registration on serverwww.alarmserver .net www.alarmserver .net
GSV on system Checking connectivity2 Send project to server 2 Send project to server Connecting server3 Receive prj. from 3 Receive prj. from Sending data4 Send event log 4 Send event log Sending completed5 Send technical info 5 Send technical info
Page 8
System compliance and warranty
Kodinis Raktas UAB, manufacturer of SECOLINK Intruder Alarm System, offers a Warranty for a term of twenty­four months. It declares, that products KM24, KM24A, and KM24G comply with essential EU directives and EU standards EN 50131-1, Grade 1 for wired & wireless zones intruder alarm systems, Grade 2 for wired zones intruder alarm systems, Environmental Class II; EN50131-3. For more information visit manufacturer’s website at www.kodinis.lt or www.secolink.eu for a complete text of declaration. SECOLINK Intruder Alarm System is designed and manufactured in Lithuania.
Rev.27/12/16_KF_P