SECOLINK KM24, KM24A, and KM24G are user-friendly new concept keypads. Large graphic display with helpful texts and
backlit keys simplify the use of an alarm system. There are options to customize main screen information and change contrast
or backlight intensity of LCD and illumination of keypad keys. User can easily follow the blinking keys as prompts to operate the
system without any commands needed to memorize. Arming, disarming, and zone bypassing is simple and can be done
intuitively . The main keypad functions and primary display view are shown in the figure below.
Date
Partition status
System status
Info bar (KM24G)
Arm
Disarm
14:1510/02+25°C
READY TO ARM
1st Floor
Bedroom+25°CRad.Stat.: perfect
Living room+24°CRad.Stat.: perfect
2nd Floor
Temperature (KM24A, KM24G)
Time
Zones, partitions
Sound settings
System information
Return to upper menu level, alarm/
trouble review and clear
Zone bypass
Navigation keys
Emergency keys
Entering selected menu item, value
entry , selection confirmation
Functional key
This key is used for partition review,
also for marking all partitions, or
selecting another element
This key is used for zone review, also
for marking the partitions and other
elements of the system
Ways of arming
The system can be armed in two ways: with a special key, or by entering a PIN code (symbol is used to prompt you to
enter your PIN code). When Arming is activated using the key, it is necessary to mark the p artitions (areas), which will be
armed (use keys ... or to mark a particular partition (area), or use to mark all partitions and proceed by pressing to
confirm the selections). If arming is activated by entering a PIN code, your system will be armed in Away mode.
!
!
!
!
4
4
4
4
1111
####
GHI
GHI
GHI
GHI
ENT
Away arming mode
Use this mode for premises protection when no one will be staying inside. When armed in Away mode, all zones will
be secure and the system will sound an alarm if a protected zone is violated. User must disarm the system within the
entry delay period or an alarm will occur. There are three ways to arm your security system'sAway arming mode:
for EU countries – , Away , .
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
for non-EU countries – , Away .
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
PIN code: .
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
ENT
ArmingAll To Exit
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
Press the key.
ENT
ArmingTo Exit
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
Press the key.
Arm
ÜÜÜÜ
Enter PIN
partitions30
ÜÜÜÜ
Enter PIN
ENT
Enter your PIN code .Leave the premises.
seconds
30
seconds
ENT
Leave the premises.
To Exit
30
seconds
Enter your PIN code .PIN code entry.Leave the premises.
Use this mode when you are staying at home, but expect someone to use the entrance door later. Interior zones will
not be protected and you may freely move throughout the premises. Late arrivals can enter through the designated
entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm
will occur. There are two ways to arm your security system's Stay arming mode:
for EU countries – , Stay , .
for non-EU countries – , Stay .
ENT
ENT
Max Away arming mode
Use this mode when no one will be staying on the premises for a long period of time (e.g., vacations). Close all
protected perimeter windows and doors before arming. When armed in Max Away mode, all zones will be secure,
entry delay will turn off, and the system will sound an alarm if a protected zone is violated. There are two ways to arm
your security system's Max Away arming mode:
for EU countries – , Max Away , .
for non-EU countries – , Max Away .
ENT
ENT
Night arming mode
Use this arming mode when you are staying inside the premises and require increased security . Interior zones are
disarmed and you may freely move throughout the premises. In the event of someone opening the door there will
not be an entry delay and the alarm will sound. This arming mode is effective when doors and windows are secured
with opening sensors, or glass break detectors are installed. There are two ways to arm Night Arming mode:
for EU countries – , Night , .
for non-EU countries – , Night .
ENT
ENT
Partial Arming
Partitions allows you to break up a large area into smaller sections. Use this arming mode to arm certain areas of the
premises while leaving other areas disarmed, or to limit other user’s access in specific areas. For example: an alarm
system is installed in a two-story house. During night time the ground floor isn't being used and all sensors of this
partition are armed. There will be an entry delay in the event of someone opening the door . Below is an example of
how to arm a first partition (one of two) in Away mode.
ENT
for EU countries – , Away , , .
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
for non-EU countries – , Away , , .
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
1111
Arming
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
Press the key.
1111
ENT
1111
Arming
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
Press the key.
1111
Arming and disarming of security barrier, “Pre-Alarm” mode
Microwave or infrared rays based security barriers, outdoor PIR detectors, which are connected to the system, can
be armed by Pre-alarm mode. In the event of someone crossing this electrical barrier the system will sound an
alarm without sending an alarm message to Central Monitoring Station. The Pre-alarm mode can be turned on and
off the same way . Please follow the instructions below:
ENTENTENTENT
, Pre-Alarm , , .
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
1111
SOUNDS
Pre-Alarm
Press [ENT] to confirm
Press [ ] to select mode
Press [1]..[4] to select part.
Bypassing a zone allows you to leave a door or window open while arming the rest of your security system. There
are two different types of bypass: temporal or permanent. Temporal bypass is used for a one time arming and
disarming cycle. Permanent bypass is used until the user unbypasses the zone. Enter the zone number you would like to
bypass. THIS MUST BE A TWO DIGIT NUMBER. The zone will be marked as " ". To bypass the zone for a long time
(permanent) the last number should be pressed and held for 2 sec. A zone will be marked as " ". Press when all zones are marked. The same actions can be performed by choosing the zone with or keys and by marking a chosen zone with the
####
key (short press - temporal, long - permanent). To bypass follow the step s below:
!
!
!
!
BY
BY
BY
BY
B
B
B
B
, Zone bypass, , ... or , and ,
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
!
!
!
!
BY
BY
BY
BY
B
B
B
Press the key.
B
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
!
!
!
!
BY
BY
BY
BY
B
B
B
Press the key.
B
9
0000
WXYZ9WXYZ9WXYZ9WXYZ
Zone
Bypass
ÜÜÜÜ
Enter PIN
Enter your PIN code .
Zone
Bypass
ÜÜÜÜ
Enter PIN
Enter your PIN code .
ENTENTENTENT
####
Zones
1 !Entry Door
2 Hallway
3 Living room
4 Be droom
5 K itchen
6 Bathroom
Zone named Entry Door is
violated (!). To bypass
press the key.
Zones
1 ! Entry Door
2 Hallway
3 Living room
4 Be droom
5 K itchen
6 Bathroom
####
Zone named Entry Door is
violated (!). Press the key
and hold it for 2 seconds.
####
Zones
1 xEntry Door
2 Hallway
3 Living room
4 Be droom
5 K itchen
6 Bathroom
Zone is bypassed
temporarily.
Press the key.
Zones
1 X Entry Door
2 Hallway
3 Living room
4 Be droom
5 K itchen
6 Bathroom
Zone is bypassed
permanently.
Press the key.
ENTENTENTENT
ENTENTENTENT
ENTENTENTENT
10/02 . . 25°C14:02
BYP ASSED
Entry Door
10/ 02 . . 25°C14:02
BYP ASSED
Entry Door
Abort arming
CLRCLRCLRCLR
Clear key is used for selecting and aborting procedures. For example, if exit delay is in process and you want to
abort arming, press the key and enter your PIN code.
CLR
Arming system with troubles
EU standards do not allow the use of a troubled security system. Green LED light of the key will turn on and
arming of the system with previously described ways will not be possible. It is necessary to immediately eliminate
system troubles, inform CMS, and the company that had installed your system. The system detect s troubles of its
own modules as well as other common problems such as 230V disappearance in AC line, a disconnected phone line due to
repairs, or a battery discharge. In exceptional cases it is possible to bypass certain troubles for a short period of time and arm
the system as usual. T o arm a system with troubles please do the following:
Press the key once and a message describing system troubles will be shown on the display . Press again and the Green
CLRCLRCLRCLRCLRCLRCLRCLR
LED light will start to blink rapidly . Blinking duration is 30 seconds and during this time it is possible to activate Arming of your
system as usual.
CLRCLRCLRCLR
Emergency keys
To activate an emergency function press at once two event specific keys listed below and hold it for at least 1
second. Premises must be secured by CMS for these functions to activate. An audible emergency loud siren will
occur showing a related message on the keypad screen.
Fire alarm: + .
Medical alarm: + .
Panic alarm: + .
AAAA1111
!
!
!
!
BY
BY
BY
BY
B
B
B
B
CCCC
!
!
!
!
4
4
4
4
GHI
GHI
GHI
GHI
7
PQRS7PQRS7PQRS7PQRS
Ways of disarming
Disarming can be done in two ways: with a special key or by entering a PIN code. User has an option to disarm all or
selected partitions when disarming is activated with the key. For partial disarming it's necessary to unmark the partitions
which will be disarmed (unmark the partitions by pressing ... keys or select partitions by pressing , keys and
unmark/mark by pressing , or keys). All partitions which are controlled by the user will be disarmed when disarming is
####
activated by entering a PIN code.
!
!
!
!
4
4
4
4
1111
GHI
GHI
GHI
GHI
To Disarm the System Using Your PIN Code Upon Entering the Premise
Entry delay gives you time to disarm the system when you enter through the designated entrance door. You must
disarm the system before entry delay period ends to avoid an alarm occurrence. There are two ways to disarm the
Partial disarming is used when you want to disarm certain areas while leaving other areas armed, or to limit access
to certain areas to other users. Below is an example explaining how to disarm a first partition of two.
, Disarming, ... , , .
Entry Delay
30
seconds
Press the key. Press the key.
!
!
!
!
4
4
4
4
1111
ENTENTENTENT
GHI
GHI
GHI
GHI
Disarming
All partitions
Press [ENT] to disarm
Press [1]..[4] to select part.
1111
Partitions
1 1st Floor
2 2nd Floor #
Press the key.
ENT
10/02 . #25°C14:02
Disarm
ÜÜÜÜ
Enter PIN
Armed
2nd Floor
Enter your PIN code .First partition is disarmed,
second partition remains armed.
Alarm clearing
During an alarm the keypad screen will display a message “Alarm!!!” with an explanation and reasons that caused it.
Red LED light of the key will turn on, the siren will start to sound aloud, and a report about the alarm will be sent to
CMS or (and) the user. There are two ways to clear the alarm and turn off the red colored LED light.
CLRCLRCLRCLR
, - this type of clearing will stop the siren sound, turn off the red LED light, and the system will return to the
prior pre-alarm status. The system will cause an alarm if the system has a smoke detector and an alarm was caused by
smoke from domestic reasons, whether it was armed or disarmed. It is possible to clear this type of alarm by bypassing the
smoke detector (see page 3, "Bypassing zone - B").
- this type of clearing will stop the siren sound, turn off the red LED light, and the system will be disarmed, even if it was
armed previously by entering the PIN code. It is not recommended to use a PIN code for alarm clearing when all partitions
(areas) controlled by the user are disarmed due to a possible casual arming.
CLRCLRCLRCLR
Event log review
All events related to protected premises and statuses of the system are stored in the event log. This log will display
all events chronologically and includes information, such as types of alarms, troubles or breakages, control events,
and more. Use and keys for navigation and viewing next or previous events in the event log.
ENTENTENTENTENTENTENTENTENTENTENTENT
, Event Log , Alarm Events , ;
ENTENTENTENTENTENTENTENTENTENTENTENT
, Event Log , Trouble Events , .
Sensor operation testing, testing zones
It is recommended to perform sensor operating testing at least once per month. During testing it will be necessary to
make some type of violation in order to check the functionality of available sensors. For example, opening a door or
windows with magnetic contacts, stimulating movement near the motion sensors, or by hard clapping of hands to
test the glass break detectors.
ENTENTENTENTENTENTENTENTENTENTENTENT
, Test , Burglary zone test , .
10/02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
ENTENTENTENT
2 Test2 Fire zone test
4 Technical information
Press , then .
ENTENTENTENT
Press the key.
ENTENTENTENT
Violated zones (#) can be checked by pressing and keys. To end testing press .
ZonesMain MenuTestZones
1 Entry Door1 Settings1 Burglary zone test1 # Entry Door
2 Hallway2 Hallway
3 Living room3 Event Log3 Send test report
4 Be droom4 Contr ols4 Bed room
5 K itchen5 Service Mode5 K itchen
6 Bathroom6 Bathroom
Testing zone is not
violated.
ENTENTENTENT
Permission to make system changes (service mode entry)
An installer will have permission to make system changes settings only after a user approves it by entering a
PIN code for security reasons. There are two ways to allow the installer to begin system changes:
ENTENTENTENTENTENTENTENT
, Service Mode , .
, .
ENTENTENTENT
3 Living room
Testing zoneis violated
(passed test).
Change activated user's PIN code
SECOLINK manufacturer will provide a 4-digit PIN code of the system which is generated in a sequential order,
unique to each user, and is related to his/her number in the system. For example, first user’s default PIN code will be
0001, second user’s default PIN code will be 0002, and so on. It is strongly recommended to change your default
PIN code in one of these two ways:
ENTENTENTENTENTENTENTENTENTENTENTENTENTENTENTENT
, Settings , Users , Change PIN , , New PIN:, enter new PIN, Repeat:, repeat the new PIN,
Changed.
, , , New PIN:, enter new PIN, Repeat:, repeat the new PIN, Changed.
The factory default PIN should be used temporary and changed as soon as possible to new one. It is recommended to
change old PIN to new one avoiding the PIN that could be used as default for other users (default PIN range 0000 to 0063). It
is not recommended to use PIN codes that contain two or more same digits (e.g. 1 11 1 or 1212) or consist of consecutive digits
(e.g. 3456). The keypad will inform the user that the PIN code change is necessary , if the PIN code is known/reconized to
other user. Using an invalid PIN code three times may: trigger an alarm and block the keypad for 90 seconds.
Review all activated users
It is recommended to review how many users can control the system after an installation. To view activated users:
ENTENTENTENTENTENTENTENTENTENTENTENTENTENTENTENT
, Settings , Users , Edit Users , , ... .
LCD screen will display a user’s number (e.g., U01) and status (e.g., Enabled or Disabled). All users with an
Enabled status can control the system or its partitions (areas).
Chime mode
This feature can be used only while the intruder alarm system is disarmed. Your system can be set to alert you by
sound or lighting of the LCD display and keys when doors or windows are being opened, or during any violation of
the selected zone. T o select which zone will feature a Chime function press the key on a selected zone which will
####
then be marked by . Press the key to change Chime melody (symbols , could appear). T o enable this function
please do the following:
, , Chime , ... or and , .
ENTENTENTENT
9
0000
WXYZ9WXYZ9WXYZ9WXYZ
ENTENTENTENT
####
Date and time settings
ENTENTENTENTENTENTENTENTENTENTENTENTENTENTENTENT
, Settings , Date and Time , , (enter date and time), .
Date Format
Two different date formats are available in the system: Year-Month-Day (YYYY-MM-DD) or Day/Month/Year
code is entered. The user must press the key after the last not fixed PIN code digit is entered. PIN code length can be
changed in the menu as follows:
V arious settings of LCD screen and keypad backlight allow the user to customize the illumination to match different
environments. For example, LCD backlight can be turned on at all times in places where it is necessary to always
see the status of the system, or the keypad can be illuminated after any key is pressed or zone is being violated. A vailable
settings of LCD display and keypad backlight are as follows: Always – backlight is always ON; By zone - backlight is turned
ON, when at least one of the following events occurs: an entry/exit delay is in progress; an alarm is triggered; either a Chime
zone or a zone marked with "+" sign in the "Events from zones" list is violated; and any of the keypad keys is pressed.
Colored backlight of , , , and keypad keys represents system status or prompts and can be customized to
match different situations. Available settings: Off;Always – status LEDs are always visible; By zone – status LEDs
are visible when at least one of the following events occur: an entry/exit delay is in progress; an alarm is triggered; either a
“chime” zone or a zone marked by "+" sign in the Events from zones list is violated; or any keypad key is being pressed.
Backlight of the key can be customized to match different environments or situations that occur. Available
settings: Off - the key Green LED is always Off; Prompt - the key Green LED blinks when the system is ready to
be armed; Armed - the key Green LED is steady On when the system is armed; Armed and Prompt – the key Green LED is steady On when the system is armed. When the system is ready to be armed, the key LED blinks.
The keypad is equipped with a special key and its backlight blinks if there is some additional information. T o find
information about how to manage the system or a problem, press the key .
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
Arming
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
????????
The key will start to blink.
It means that a help text is
available for this menu.
????????
Press key to read the
help text.
????????
????????
Use this mode for premises Press [CLR] to exit.
protection when no one will
be staying inside. All zones
will be protected after
arming. There will be an
entry delay after using a
door.
Press or key to
Press to exit.
navigate (if there are
additional text).
Arming
Away
Press [ENT] to arm
Press [ ] to select mode
Press [1]..[4] to select part.
CLRCLRCLRCLRCLRCLRCLRCLR
Arming mode Away.
ENTENTENTENT
Info bar (KM24G)
KM24G keypad has a two line information bar at the bottom of the LCD screen. It displays information including the
alarm memory, measured temperature by SECOLINK BP1 or BT1 wireless sensors, the statistics of
communication between SECOLINK wireless sensor and a receiver, PGM output status (On/Off), GSM signal strength,
messages from modules, and etc. The information will rotate by appearing on the LCD screen every 3 seconds if there are
more than two lines of information text. Use the key to expand/collapse the bar if it is desired to view all the information at
once.
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Info bar is not enabled.
Interface settings
7 Show info bar
Show Alarms
Show Modules Mess.
Show WL Zone Temp.
Show PGM status
Show Tech. Info
Bedroom+25°C
Living room+24°C
SERIAL Reporting Enabled
GPRS Reporting Enabled
GSM signal strength
Press to collapse the
info bar.
System information
System summary, technical, distributor and installer information can be found by pressing the key when the
keypad is displaying the main view . Choose the corresponding menu and press .
10/ 02 . . 25°C14:02
READY TO ARM
1st Floor
2nd Floor
Press the key.
????????
ENTENTENTENT
System
Summary
Press [ENT] to confirmPress [ENT] to confirmPress [ENT] to confirm
Press [?] for next settingsPress [?] for next settingsPress [?] for next settings
Communication and messaging (GSVx or VIDNET module must be installed)
This menu allows the user to add phone numbers to receive SMS and call notifications.
Number – phone number must be entered in the international format, "+" sign is added automatically.
Smartphone – in this menu the user may specify the SECOLINK PRO application that is used to control the
system. Possible setting options are described below:
No – SECOLINK PRO application is not used.
Android – SECOLINK PRO application for Android OS is used.
Iphone – SECOLINK PRO application for Apple iOS (iPhone) is used.
Push notifications – a message or an alert delivered by a centralized server to endpoint devices. This
setting is mandatory for iPhone SECOLINK PRO application users who paid for this additional functionality .
This communication uses data service and charges may apply .
SMS when armed - SMS notification that the system is armed.
SMS when disarmed - SMS notification that the system is disarmed.
SMS when alarming – SMS notification in the event of a triggered alarm.
Call when alarming – notification via a phone call in the event of a triggered alarm (GSVx only). Incoming
call must be acknowledged either by pressing 0# or by entering PIN#.
Mandatory call – notification via a phone call in the event of a triggered alarm (GSVx only). Mandatory call
differs from Call when alarming setting by enabling the user to receive a call even if another user in the list
acknowledged the call by pressing 0# or by entering the PIN#.
SMS for troubles – SMS notification when the system has any troubles (e.g. battery low).
T esting SMS – test notifications via SMS.
ENTENTENTENTENTENTENTENTENTENTENTENT
, Settings , Cell phones (GSM) , .
System control via TCP/IP (GSVU, GSV6U, LAN800 or VIDNET must be installed)
ALARMSERVER.NET is simply a service platform that keeps in sync end user devices which have the SECOLINK PRO app
installed with the alarm system. Status (armed/disarmed, alarms, troubles), temperature in premises (measured by
temperature sensors BT1, BP1, or keypads), and video recordings made by VIDNET can all be monitored using the service.
This communication uses data service and charges may apply .
1 Registration on server1 Registration on server
6 Reporting6 Reporting
Alarmserver.net menuReporting settings.Registering on
ReportingPrivacy settings
1 Periodic test
2 Technical info2 Report zone names
3 Every event3 Save event log
4 Event log
5 TCP control
Disabled
Enabled
1 Report user names
Yes
No
Yes
YesEvery 10 min
Yes
Privacy settings.Registration completed.
ALARMSERVER.NET.
Registration on server – this menu is used to register your intruder alarm system on ALARMSER VER.NET and to send any
settings related to communication. It is mandatory to register your system with a server, if SECOLINK PRO application will be
used to control the system via TCP/IP. Registration should be done when all below mentioned settings are programmed.
After a successful registration go to www.alarmserver.net to create a free account. Important! The registration on server
process should be repeated if any settings described below are changed.
Reporting – in this menu the user can change settings for reports on ALARMSER VER.NET .
Every event – to view present status of the system, all new generated events (e.g. arming/disarming, alarms) should be
sent to ALARMSER VER.NET . This communication uses data service and charges may apply.
TCP control – this setting must be enabled, if SECOLINK PRO application will be used to control the system via TCP/IP.
Module will have a keep-alive connection with a server to ensure real - time control.
Privacy settings – in this menu the user can change privacy settings.
Report user names – selecting an option Yes will allow the system to send user names to ALARMSER VER.NET, which
can be viewed in SECOLINK PRO application. The application will show default system names such as User 01, User 02, if
the user will select an option No.
Report zone names – selecting an option Yes will allow the system to send the names of zones, partitions and other
information (except users names) to ALARMSERVER.NET, which can be viewed in SECOLINK PRO application. The
application will show default zone names such as Zone 01, Zone 02, if the user will select an option No.
Save event log – selecting an option Yes will allow the user to view the saved system event log in the application. Event log
will not be seen with an option No.
ENTENTENTENTENTENTENTENTENTENTENTENT
, Settings , ... www.alarmserver.net, .
Registration on serverwww.alarmserver .netwww.alarmserver .net
GSV on system
Checking connectivity2 Send project to server2 Send project to server
Connecting server3 Receive prj. from 3 Receive prj. from
Sending data4 Send event log4 Send event log
Sending completed5 Send technical info5 Send technical info
Page 8
System compliance and warranty
Kodinis Raktas UAB, manufacturer of SECOLINK Intruder Alarm System, offers a Warranty for a term of twentyfour months. It declares, that products KM24, KM24A, and KM24G comply with essential EU directives and EU
standards EN 50131-1, Grade 1 for wired & wireless zones intruder alarm systems, Grade 2 for wired zones
intruder alarm systems, Environmental Class II; EN50131-3. For more information visit manufacturer’s website at
www.kodinis.lt or www.secolink.eu for a complete text of declaration. SECOLINK Intruder Alarm System is
designed and manufactured in Lithuania.
Rev.27/12/16_KF_P
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.