ENROLLING AND PROGRAMMING
PET IMMUNITY GUIDELINES
1
Se rv ice m od e
Sy ste m se tup
Enable the wireless zone by changing Not used
loop type to any other loop type. If the system uses
a keypad produced before 2014, an installer is
obligated to change the loop type to NO/DEOL or
Vibration.
Advance to the next unlearned zone with keypad
keys [Ь] or [7].
1
Z0 1 Li vin g ro om
Na me
Li vi ng ro om
3
Sy ste m se tup
Zo ne s
Z0 1 Li vin g ro om
Lo op t ype
NO /D EOL
3
Z0 1 Li vi ng r oo m
WL d et . loo p (zo ne ) ID 18 1
4
Z0 1 Li vin g ro om
Ad dr ess
06 _1
3
Enter the zone address in MA_Z format, where MA
is a module address in the system and Z is a zone
number in the module.
Note: for wireless zones MA_1 – MA_8 the system
will automatically assign NO/DEOL loop type and
for wireless zones MA_9 – MA_16 the Vibration
loop type. Don't change the loop type of a zone!
Module address:
EXT116S - address 06 (default) or given during
the registration process;
Virtual module EXT116S address depends on the
control panel type:
P16 - address 12;
P32 - address 12 and 13;
P64 - address 12, 13, 14 and 15.
The wireless detectors send a supervision signal
approximately every 1 hour. If the system does not
receive supervision (or alarm signal) signals from a
specific transmitter, the transmitter is regarded as
ina cti ve. The amo unt of tim e af ter whi ch a
transmitter is considered inactive is called the
Supervisory window.
Note: 0 hours disables the supervision. If there are
many detectors in the system, due to increased
collis ion effect, it is recommended to set the
supervision time to a minimum of 2 hours.
Enter wireless detector loop (zone) ID number and
press the [ENT] key to start enrolling. This field may
also be used for deleting the sensor from the
module.
When enrollment has started, immediately press
the tamper switch for a short period of time (~1 sec)
as shown in the picture. You will feel a light click after
pressing the switch. The tamper switch is now
activated and the detector will transmit a tamper
message.
Done
Wa i tin g for
WL de tec tor
Wireless detector successfully enrolled. No additional transmissions are needed for confirmation.
BP2
Supports Wireless detector loop (zone) ID number
Passive infrared
sensor
(PIR sensor)
180
255
Built-in
temperature
sensor
Delete detector in
a specific zone
Delete all
detectors
in a specific
wireless module
All
All
181
254
Intruder alarm system
Installation manual
BP2
Use
Wireless detector loop (zone) enrolling ID numbers
Page 2
Pulse counter determines the amount of beams that
need to be crossed before the sensor will produce
the alarm. Use [Ѓ] or [‚] to change the setting: 2
pulses (the most sensitive mode), 3 pulses, 4
pulses or SPEC (the less sensitive mode).
Note: This setting could be changed using KM24,
KM24 or KM24G keypad.
Z0 1 Li vi ng r oo m
Pu ls e cou nte r 2 pu ls es
15
Use this setting to adjust the detection range. Range
can vary due to environmental conditions. To reduce
the risk of false alarms always select the lowest range
possible for the installation.
Note: This setting could be changed using KM24,
KM24A (firmware: v.2.067 and higher) or KM24G
(firmware: v.2.021 keypad and higher).
Z0 1 Li vi ng r oo m
PI R Se nsi ti vit y
No rm al
16
It is expected that the detector with pet immune array lense will eliminate false alarms caused by:
Animals up to 25 kg,
Several small rodents,
Random flying birds.
Note: The weight of the animal should only be used as a guide; other factors such as the length and color of fur also affect the level of immunity.
For maximum pet immunity the following guidelines are recommended:
Mount the center of the detector at a height of 2,1 m.
Set the pulse counter to SPEC.
Do not aim the detector at stairways that can be climbed by an animal.
Avoid a location where an animal can come within 1,8m of the detector by climbing on furniture, boxes or other objects.
Z0 1 Li vi ng r oo m
Su pe rvi so ry wi nd ow 2 h
7
BP2, BP2-p Wireless detector
Enrolling
Supervisory check
Pulse counter
2 pulses
3 pulses
4 pulses
SPEC
Beam
Fast detection performance
Good detection and false alarm
protection ratio
Max false alarm protection in
hostile environment
Pet immune applications
(with pet immune array lens)
Sensitivity
~12
~5
Small room
Large room
12h
after ~1h after ~2h after ~3h
received received missing - supervisory trouble
?
?
?
Supervisory window: 1h
Supervisory window: 2h
missing - waiting for other... received received