SECOLink BP2, BP2-p Installation Manual

~2 years
INSTALLATION
The BP2 or BP2-p detector provides the convenient and cost effective solution for security The detector is compatible with wireless extension modules EXT116S reliable, protection.
or with built-in virtual modules EXT116SVM in P series control panels P16, P32 and P64.
SECOLINK WIRELESS DETECTORS
SPECIFICATIONS
Model Passive infrared sensor (PIR sensor)
Built-in temperature sensor Long range array
Optional
Not available
Ambient temperature Battery
Battery life
BP2
BP2-p
Wide angle array
Pet immune array
54,8 mm x 100 mm x 39 mm
o o
0 C - +55 C 0% - 70% Depends on firmware version of the detector: Lithium battery
½ AA, 3,6V
Operating frequency
1 = 868,30 MHz (EU) 9 = 915,30 MHz (AU)
3b 4
Remove the isolation tab. Follow the instructions on a 2nd page and enroll the detector into the system. After a successful detector's enrollment close the top cover. Use the screw to secure the top cover to the mounting base.
BP2, BP2-p Wireless detector
Intruder alarm system
Installation manual
1
1
2
2 3
Pull the isolation tab
LED
3a
Corner mount Surface mount
Use for swivel mount bracket
De tec tor's re com mende d m oun ti ng height is 2,1 meters (+/- 20 cm). It is designed to be mounted on surfaces, in corners (3a), or installed in places where it is necessary to use a swivel mount bracket (3b). Find a suitable location (place) for the detector keeping in mind the warnings below: Keep away from heat source. Do not expose to air drafts. Do not install outdoors. Do not obscure partially or completely
the detector's field of view. Avoid direct sunshine. Keep away from power cables. Mount on solid and stable surface.
Page 1
LED ON
LED OFF
O
Wide angle array
(BP2)
WA 0.9 GI 6 T1
1,90 3,3 5,9 15m
2,1m
o
98
50 10 15m
15m
0
5
5
10
15m
10
Long range array (optional for BP2)
(LR 0.9 GI 6 T1)
50 10 15 20m
15m
5
5
10
15m
10
0
2,1m
1,80 3,3 5 20m8,4
CHANGING THE LENSES
To change a lens, release the lens cavity fix the new lens into place with the cover by simultaneously pressing the plastic supports (1) to the direction as shown in picture. Gently smooth side facing outwards. Verify that the lense name is located at the top of the lens before snapping the cavity cover back into place.
1
1
Lens array type
Pet immune array
(BP2-p)
15m
2,1m
(WP 0.9 GI 6 T1)
50 10 15m
15m
0
5
5
10
15m
10
o
95
2,10 4,8 8,6
ENROLLING AND PROGRAMMING
PET IMMUNITY GUIDELINES
1
Se rv ice m od e
Sy ste m se tup
Enable the wireless zone by changing Not used loop type to any other loop type. If the system uses a keypad produced before 2014, an installer is obligated to change the loop type to NO/DEOL or Vibration.
Advance to the next unlearned zone with keypad keys [Ь] or [7].
1
Z0 1 Li vin g ro om
Na me
Li vi ng ro om
3
Sy ste m se tup
Zo ne s
Z0 1 Li vin g ro om
Lo op t ype
NO /D EOL
3
Z0 1 Li vi ng r oo m
WL d et . loo p (zo ne ) ID 18 1
4
Z0 1 Li vin g ro om
Ad dr ess
06 _1
3
Enter the zone address in MA_Z format, where MA is a module address in the system and Z is a zone number in the module.
Note: for wireless zones MA_1MA_8 the system will automatically assign NO/DEOL loop type and for wireless zones MA_9MA_16 the Vibration loop type. Don't change the loop type of a zone! Module address: EXT116S - address 06 (default) or given during
the registration process; Virtual module EXT116S address depends on the control panel type:
P16 - address 12; P32 - address 12 and 13; P64 - address 12, 13, 14 and 15.
The wireless detectors send a supervision signal approximately every 1 hour. If the system does not receive supervision (or alarm signal) signals from a specific transmitter, the transmitter is regarded as ina cti ve. The amo unt of tim e af ter whi ch a transmitter is considered inactive is called the Supervisory window. Note: 0 hours disables the supervision. If there are many detectors in the system, due to increased collis ion effect, it is recommended to set the supervision time to a minimum of 2 hours.
Enter wireless detector loop (zone) ID number and press the [ENT] key to start enrolling. This field may
also be used for deleting the sensor from the module.
When enrollment has started, immediately press the tamper switch for a short period of time (~1 sec) as shown in the picture. You will feel a light click after pressing the switch. The tamper switch is now activated and the detector will transmit a tamper message.
Done
Wa i tin g for
WL de tec tor
Wireless detector successfully enrolled. No addi­tional transmissions are needed for confirmation.
BP2
Supports Wireless detector loop (zone) ID number
Passive infrared
sensor
(PIR sensor)
180
255
Built-in
temperature
sensor
Delete detector in
a specific zone
Delete all
detectors
in a specific
wireless module
All
All
181
254
Intruder alarm system
Installation manual
BP2
Use
Wireless detector loop (zone) enrolling ID numbers
Page 2
Pulse counter determines the amount of beams that need to be crossed before the sensor will produce the alarm. Use [Ѓ] or [] to change the setting: 2
pulses (the most sensitive mode), 3 pulses, 4 pulses or SPEC (the less sensitive mode).
Note: This setting could be changed using KM24, KM24 or KM24G keypad.
Z0 1 Li vi ng r oo m
Pu ls e cou nte r 2 pu ls es
15
Use this setting to adjust the detection range. Range can vary due to environmental conditions. To reduce the risk of false alarms always select the lowest range possible for the installation.
Note: This setting could be changed using KM24, KM24A (firmware: v.2.067 and higher) or KM24G (firmware: v.2.021 keypad and higher).
Z0 1 Li vi ng r oo m
PI R Se nsi ti vit y
No rm al
16
It is expected that the detector with pet immune array lense will eliminate false alarms caused by: Animals up to 25 kg, Several small rodents, Random flying birds. Note: The weight of the animal should only be used as a guide; other factors such as the length and color of fur also affect the level of immunity. For maximum pet immunity the following guidelines are recommended: Mount the center of the detector at a height of 2,1 m. Set the pulse counter to SPEC. Do not aim the detector at stairways that can be climbed by an animal. Avoid a location where an animal can come within 1,8m of the detector by climbing on furniture, boxes or other objects.
Z0 1 Li vi ng r oo m
Su pe rvi so ry wi nd ow 2 h
7
BP2, BP2-p Wireless detector
Enrolling
Supervisory check
Pulse counter
2 pulses
3 pulses
4 pulses
SPEC
Beam
Fast detection performance
Good detection and false alarm
protection ratio
Max false alarm protection in
hostile environment
Pet immune applications
(with pet immune array lens)
Sensitivity
~12
~5
Small room
Large room
12h
after ~1h after ~2h after ~3h
received received missing - supervisory trouble
?
?
?
Supervisory window: 1h
Supervisory window: 2h
missing - waiting for other... received received
KM24G keypad:
KM24, KM24A keypad:
14 :1 510 /0 2 +2 1° C
REA DY TO A R M
1s t Fl oo r 2n d Fl oor
Li vin g roo m
Be dro om
+2 1°C +2 2°C
Intruder alarm system
Installation manual
TEMPERATURE SENSOR
BP2 has a built-in temperature sensor. Measured temperature value could be seen at the bottom bar of the KM24G keypad, in menu Technical info (for KM24 or KM24A keypads), in SMS (together with a sys tem status infor mation) , in app lica tion SECOLI NK P RO a nd i n a service platf orm www.alarmserver.net . The temperature is measured even if the detector BP2 is programmed as motion detector.
Along with the motion detection, the detector can also be programmed as temperature zone. Temperature zone could trigger the technical alarm or can be programmed to silently trigger a PGM output (attribute No alarm should be enabled) when the measured temperature value reaches the programmed threshold. Use the 180 enrolling ID number to program the BP2 temperature sensor in
the system.
Used for 24h High temperature or 24h Low temperature. A zone with this attribute will not trigger an alarm, but can start PGM action.
Used for 24h High temperature or 24h Low temperature. Enter the temperature. Use [Ѓ] or [] to change temperature sign (+ or -). Note: temperature field will be visible if wireless detector is in use.
Z0 1 Li vi ng r oo m
Tem pe rat ure +2 3 C
8
Z0 1 Li vi ng r oo m
No a la rm Yes
10
Z0 1 Li vi ng r oo m
De fi nit io n 24h H ig h tem pe r
6
Tec hn ica l in for mat io n
-- -- --- -- --- -- --- -- --- -- --- -- Temp
Be dr oom
+2 1C
Z0 1 Li vi ng r oo m
WL d et . loo p (zo ne ) ID 18 0
4
1
2
Useful information:
Use PGM definition Zone violation too keep the output turned On or Off while temperature zone is violated. Zone should be checked in PGM triggering sources, the setting Pulse
Length value should be 0 seconds/minutes. The output will go to previous state when zone will restore.
WIRELESS DETECTOR OPERATION AND TESTING
To test wireless detector operation enable the test mode by doing a burglary zone test:
When motion is detected, the detector will transmit to the receiver and will then go to sleep mode for 4 minutes. If motion is detected again during the sleep time, the unit will not transmit the event to the receiver. The detector will thus remain in the sleep mode until 4 minutes after the first motion detected was transmitted. The detector will transmit detected motion every 4 minutes.
Jutiklis įeis į testavimo režimą, tik kai bus išsiųstas pirmas suveikimas ir liks šiame režime kol zonų testas bus vykdomas iš valdymo pulto.
~ 4 min ~ 4 min
5
4
Co nt rol s
3
Ev ent L og
2
1
Ma in M enu
Se rv ice M od e
Se tt in gs
Tes t
1
1
1
Tes t
Zo ne s:
Zo ne s:
Bu rg lar y zon e te st
Li vi ng ro om
Li vi ng ro om #
~ 4 min
or less
~ 10 sec ~ 10 sec
TEST
STARTED
TEST
ENDED
When performing a zone test, the detector must be left idle for 4 minutes before testing can be performed. Once 4 minutes has passed, create motion in front of the detector to see if the device is both detecting motion and transmitting to the receiver. When motion is detected (#) the detector will go to sleep only for ~ 10 seconds. The short sleep time allows to adjust the best range of view. To end testing press [ENT].
~ 4 min
Testing zone is violated (passed test).
1
Se rv ice m od e
Sy ste m se tup
3
Sy ste m se tup
Zo ne s
Li vi ng ro om
+2 2C
Enter wireless detector loop (zone) ID number and press the [ENT] key to start enrolling. When enrollment has started, immediately press the tamper switch for a short period of time (~1 sec).
Page 3
SECOLINK PRO:
BP2, BP2-p Wireless detector
Intruder alarm system
Installation manual
Page 4
Change setting's Attenuation value to 3dB. Save changes by pressing the [ENT] key.
Caution: Each wireless detector is supervised by a check-in signal that is sent to the receiver at 60 minutes interval. During this check-in commu­nication the detector will receive new settings and will start to work according to them. DO NOT
FORGET to change the Attenuation setting's value to 0dB when installation or maintenance works are finished.
IMMUNITY TO ATTENUATION
Due to the fact that there may be changes in the passive environment after installation, it is possible to temporarily attenuate the radio frequency link during installation or maintenance. In order to temporarily attenuate the radio frequency link change the setting Attenuation as described below:
1
Se rv ice m od e
Sy ste m se tup
7
Sy ste m se tup
Wi re les s se tt in gs
1
1
1
Wi re les s se tt in gs
Wi re les s se tt in gs
Wi re les s se tt in gs
At ten ua ti on
At ten ua ti on
At ten ua ti on
3d B
3d B
0d B
Temporarily
attenuated signal
during installation or
maintenance
Normal signalNormal signal
TECHNICAL INFORMATION (SUPERVISORY, RSSI, BATTERY VOLTAGE)
SUPR - each wireless detector is supervised by a check-in signal that is sent to the receiver. The period of detector sending check-in signal is 1 hour. Supervisory is expressed as percentage values, measured while system is armed. RSSI - Received Signal Strength Indicator is a common name for the signal strength in a wireless network environment. It is a measure of the power level that a RF client device (control panel/module) is receiving from an access point (detector). RSSI is the relative signal strength in a wireless environment and it is expressed as percentage values between 1-100. The information how the detector „see“ the panel/module in the wireless network can be found in ALARMSERVER.NET ( collumn RSSI, wl ). BATT - the battery voltage is the average voltage of last six measurements when detector is sending the information to receiver. Low battery
threshold voltage < 2,45V.
SERVICE PLATFORM ALARMSERVER.NET
ALARMSERVER.NET is an online platform for alarm systems installers and end users. The installer can This platform requires the installer to log in to gain access to the page. see the consist of the system, installed device serial number and firmware versions. He can also remotely monitor alarm systems technical status (supervisory statistic, RSSI on control panel or detector side, battery status, activity), see the triggered alarms and troubles. This information allows the installer to more precise identify the possible troubles in the system, before taking actions and going to site. Security system devices send its status and technical information automatically or manually by request.
BATTERY INSTALLATION/REPLACEMENT
This system is designed to work with Do not install any other type. Use fresh batteries. Most batteries Lithium battery ½ AA, 3,6V battery. have a “best before” date printed on their packaging or on the batteries themselves. Buy batteries that have a “best before” date of two years or more from your purchase date. Battery life of wireless detectors depends on the environment, usage, and the specific wireless devices being used. Factors such as humidity, high or low temperatures, as well as large swings in temperature may all reduce the actual battery life
in a given installation. When the battery is nearly dead , the detector will send a low battery signal (low battery threshold voltage < 2,45V) to
the alarm system for the user to replace it before it discharges completely.
1. Unscrew the self-tapping screw.
2. Remove the detector's top cover.
3. Observe correct polarity and insert the battery into the battery holder.
4. Close the top cover and secure it with a self-tapping screw.
5. Dispose of used batteries as per local regulations. Caution: the detector will send a tamper message to the receiver when housing is opened - the alarm can be triggered.
Tec hn ica l in for mat io n
-- -- --- -- --- -- - SUP R RS SI BAT T
Be dr oom
10 0%
10 0%
98 %
99 %
3. 60 V
3. 54 V
1
2
Li vi ng ro om
BP2, BP2-p Wireless detector
Please act according to your local rules and do not dispose of your unusable alarm system or its components with other household waste. This product utilization in EU is covered by European Directive 2002/96/EC.
Kodinis Raktas UAB, manufacturer of SECOLINK Intruder Alarm System, offers a Warranty for a term of twenty-four months. It declares, that product BP2 complies with essential EU directives and EU standards EN 50131-1, Grade 1, Environmental Class II; EN 50131-2-2. For more information visit manufacturer’s website www.kodinis.lt or www.secolink.eu for a complete text of declaration. SECOLINK Intruder Alarm System is designed and manufactured in Lithuania.
Rev.18/12/17_KF_Sert
SYSTEM COMPLIANCE AND WARRANTY