SECO-LARM USA SD-927PKC-NEQ User Manual

SECO-LARM's "No Touch" Request-To-Exit Sensor uses IR technology to open a door or activate a device with the simple wave of a hand. The trigger distance is up to 4". Since it is no touch, this sensor is ideal for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination) or for use in schools, factories, or offices (anywhere an easy way to exit is required).
Features:
No Touch -- just wave a hand in front of sensor. Sensing range up to 4" (10cm). Attractive "ring" illuminator turns from green to red when the sensor is activated. Reduce the risk of cross contamination. Easy and clean operation. Reliable IR technology senses motion. Durable stainless-steel plate. Quick-connect screwless terminal block. SPDT 3A relay output.
Technical Specifications:
SD-927PKC-NEQ
Voltage Current Drain Relay Type Response Time Output Time Range Temperature Range Weight Dimensions
12VDC 40mA @ 12VDC Form-C dry contact, 3A@12VDC 10mS
0.5S or as long as unit is triggered Up to 4" (10cm)
o o o o
-4 ~131 F (-20 ~55 C) 3oz (85g)
1 3 5
4 /
2
" x 2 /
4
" (115 x 70 x 33.5mm)
" x 1 /
16
Application:
Dimensions:
NO TOUCH
1
4 /
"
2
(115mm)
EXIT
3
"
2 /
4
(70mm)
The SECO-LARM policy is one of continual development. For that reason, SECO-LARM reserves the right to change prices and specifications without notice. SECO-LARM is not responsible for misprints.
16842 Millikan Avenue, Irvine, CA 92606
2"
(51mm)
1
"
1 /
16
(27mm)
1.949.261.2999 (CA & Int’l) 1.800.662.0800 Fax: 1.949.261.7326 Email: info@seco-larm.com Website: www.seco-larm.com
NoTouchSensorc.cdr
®
Loading...