SECO-LARM USA SA-025EQ User Manual

NOTE: Products with model numbers that end with “Q” or have a round green “Q” sticker signify RoHS-compliant products.
Manual
Delayed Egress Timer
SA-025EQ
3 Relock modes Programmable nuisance
delay timer
Adjustable pre-delay timer Adjustable post-delay timer 12~24VAC/VDC
Form C relay outputs for lock
relay and remote alarm
Transistor ground output for local
alarm outputs
Auto or programmed relocking
after power loss
IMPORTANT
Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
ENFORCER Delayed Egress Timer
Remote Alarm Relay Output ......................... 8
Lock Relay Output ........................................ 8
Local Alarm Output ....................................... 8
Pre-Delay Bypass Input ................................ 8
Free Egress Input ......................................... 9
Reset Input .................................................... 9
Initiate Input .................................................. 9
Bypass Input ................................................. 9
Lock Status Input .......................................... 9
Power Input ................................................... 9
Sample Applications .............................. 10-11
Troubleshooting .......................................... 12
Warranty ..................................................... 12
3 Relock modes to meet different installation requirements:
Standard manual relocking. BOCA (Building Officials Code Administrators) relocking.
Timed relocking (1~60 seconds). Programmable nuisance delay timer (0~3 seconds). Adjustable pre-delay timer (1~30 seconds). Adjustable post-delay timer (1~60 seconds). Selectable manual or automatic relocking after power loss. Lock relay output (Form C, 10A@24VDC). Remote alarm relay output (Form C, 10A@24VDC). Local alarm output (transistor ground, 500mA@12VDC). Door status input. Status LEDs show relay status. Bypass input immediately releases locks. Free egress input allows easy egress during the day.
Features:
Specifications:
Table of Contents:
Operating voltage
12~24 VAC/VDC
Current draw
Standby1
120mA@12VDC
Pre-delay
90mA@12VDC
Local alarm
35mA@12VDC
Timer module only
2
15mA@12VDC
Lock control output
10A@24VDC, Form C, NO/NC/COM
Remote alarm output
10A@24VDC, Form C, NO/NC/COM
Local alarm output
Transistor ground, 500mA@12VDC
Features ........................................................ 2
Specifications ................................................ 2
Dimensions.................................................... 3
Overview ....................................................... 3
Installation ..................................................... 4
Wiring Diagram.............................................. 4
Relock Modes................................................ 5
Adjusting the Pre-Delay and Post-Delay ....... 6
Setting the Power-Up Mode and
Nuisance Delay ............................................. 6
Lock Status Jumper....................................... 7
Security Mode Jumper .................................. 7
Local Alarm Output Type Jumper.................. 7
1
Lock relay and remote alarm relay are normally energized.
2
When lock relay and remote alarm relay are de-energized.
2 SECO-LARM U.S.A., Inc.
Dimensions:
Overview:
Housing
Timer module only
*Normally energized.
Relock mode jumpers (see pg. 5)
Jumpers (see pg. 7)
DIP Switch for Power-up mode & Nuisance delay (see pg. 6)
Pre-delay timer potentiometer (see pg. 6)
Post-delay timer potentiometer (see pg. 6)
Terminal block (see pg. 4)
LED 1 (Blue):
If ON, the SA-025EQ
is being powered
(see pg. 9)
LED 2 (Red):
If ON, the lock
relay is energized*
(see pg. 8)
LED 3 (Red):
If ON, the remote alarm
relay is energized*
(see pg. 8)
LED 4 (Red):
If ON, the local alarm
is being triggered
(see pg. 8)
31/4”
(83mm)
7
/8”
(22mm)
11/8”
(28mm)
211/16”
(68mm)
3
(76mm)
31/16” (78mm)
P.C. board
21/2” (63mm)
P.C. board
21/4” (57mm)
Mounting holes
213/16” (72mm)
Mounting holes
ENFORCER Delayed Egress Timer
SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3
ENFORCER Delayed Egress Timer
Wiring Diagram:
Installation:
Removing the housing
To remove the housing cover from the SA-025EQ, use a paper clip or a similar object to push one of the two tabs on the back of the unit inward.
Push tab inward.
Mounting
If mounting is necessary, secure two screws (not included) through the two screw holes located on the side of the unit to a mounting surface.
*Normally energized. (Screen print refers to energized state as normal.)
Remote alarm relay output
(10A@24VDC, Form C Relay, NO/NC/COM)* (see pg. 8)
Lock relay output
(10A@24VDC, Form C Relay, NO/NC/COM)* (see pg. 8)
Local alarm output (500mA@12VDC, transistor ground) (see pg. 8)
Pre-delay bypass input (N.O.+) (see pg. 8)
Free egress input (N.C.+) (see pg. 9)
Reset input (N.C.+) (see pg. 9)
Initiate input (N.C.+) (for unlock device) (see pg. 9)
Bypass input (N.C.+) (see pg. 9)
Lock status input (N.C.+) (see pg. 9)
Power input (12~24 VAC/VDC) (see pg. 9)
4 SECO-LARM U.S.A., Inc.
Loading...
+ 8 hidden pages