NOTE: Products with model numbers that end with “Q” or have a round green “Q” sticker signify RoHS-compliant products.
3 Relock modes
Programmable nuisance
delay timer
Adjustable pre-delay timer
Adjustable post-delay timer
12~24VAC/VDC
Form C relay outputs for lock
relay and remote alarm
Transistor ground output for local
alarm outputs
Auto or programmed relocking
after power loss
IMPORTANT
Users and installers of this product are responsible for ensuring that the installation and configuration of this
product complies with all national, state, and local laws and codes related to locking and egress devices.
SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
ENFORCER Delayed Egress Timer
Remote Alarm Relay Output ......................... 8
Lock Relay Output ........................................ 8
Local Alarm Output ....................................... 8
Pre-Delay Bypass Input ................................ 8
Free Egress Input ......................................... 9
Reset Input .................................................... 9
Initiate Input .................................................. 9
Bypass Input ................................................. 9
Lock Status Input .......................................... 9
Power Input ................................................... 9
Sample Applications .............................. 10-11
Troubleshooting .......................................... 12
Warranty ..................................................... 12
3 Relock modes to meet different installation requirements:
Standard manual relocking.
BOCA (Building Officials Code Administrators) relocking.
Timed relocking (1~60 seconds).
Programmable nuisance delay timer (0~3 seconds).
Adjustable pre-delay timer (1~30 seconds).
Adjustable post-delay timer (1~60 seconds).
Selectable manual or automatic relocking after power loss.
Lock relay output (Form C, 10A@24VDC).
Remote alarm relay output (Form C, 10A@24VDC).
Local alarm output (transistor ground, 500mA@12VDC).
Door status input.
Status LEDs show relay status.
Bypass input immediately releases locks.
Free egress input allows easy egress during the day.
10A@24VDC, Form C, NO/NC/COM
10A@24VDC, Form C, NO/NC/COM
Transistor ground, 500mA@12VDC
Features ........................................................ 2
Specifications ................................................ 2
Dimensions.................................................... 3
Overview ....................................................... 3
Installation ..................................................... 4
Wiring Diagram.............................................. 4
Relock Modes................................................ 5
Adjusting the Pre-Delay and Post-Delay ....... 6
Setting the Power-Up Mode and
Nuisance Delay ............................................. 6
Lock Status Jumper....................................... 7
Security Mode Jumper .................................. 7
Local Alarm Output Type Jumper.................. 7
1
Lock relay and remote alarm relay are normally energized.
2
When lock relay and remote alarm relay are de-energized.
2 SECO-LARM U.S.A., Inc.
Relock mode jumpers
(see pg. 5)
DIP Switch for
Power-up mode
& Nuisance delay
(see pg. 6)
Pre-delay timer
potentiometer
(see pg. 6)
Post-delay timer
potentiometer
(see pg. 6)
Terminal block (see pg. 4)
LED 1 (Blue):
If ON, the SA-025EQ
is being powered
(see pg. 9)
LED 2 (Red):
If ON, the lock
relay is energized*
(see pg. 8)
LED 3 (Red):
If ON, the remote alarm
relay is energized*
(see pg. 8)
LED 4 (Red):
If ON, the local alarm
is being triggered
(see pg. 8)
21/4” (57mm)
Mounting holes
213/16” (72mm)
Mounting holes
ENFORCER Delayed Egress Timer
SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3
ENFORCER Delayed Egress Timer
To remove the housing cover from the
SA-025EQ, use a paper clip or a similar
object to push one of the two tabs on the
back of the unit inward.
If mounting is necessary, secure two
screws (not included) through the two
screw holes located on the side of the unit
to a mounting surface.
*Normally energized. (Screen print refers to energized state as normal.)
Remote alarm relay output
(10A@24VDC, Form C Relay, NO/NC/COM)* (see pg. 8)
Lock relay output
(10A@24VDC, Form C Relay, NO/NC/COM)* (see pg. 8)
Local alarm output (500mA@12VDC, transistor ground) (see pg. 8)
Pre-delay bypass input (N.O.+) (see pg. 8)
Free egress input (N.C.+) (see pg. 9)
Reset input (N.C.+) (see pg. 9)
Initiate input (N.C.+) (for unlock device) (see pg. 9)
Bypass input (N.C.+) (see pg. 9)
Lock status input (N.C.+) (see pg. 9)
Power input (12~24 VAC/VDC) (see pg. 9)
4 SECO-LARM U.S.A., Inc.