SECO-LARM USA E-37EV User Manual

Monitors up to three zones per
premises or vehicle, plus manual paging.
One positive and two negative
instant trigger inputs.
Manual
E-37EV
Code-learning receiver learns
up to three transmitter codes.
Transmitter can page an
unlimited number of receivers.
Colored LEDs or vibrate
function indicate received page.
Unattended page indicator.
Alarm Pager System
NOTE: Antenna required. See page 3 for more details. Antenna not included.
ENFORCER E-37EV Alarm Pager System
Introduction
The E-37EV is a sophisticated paging system consisting of two parts: a transmitter with trigger and timing circuitry, and a matching E-37RV receiver with both vibrating and audible paging functions.
The pager alerts users when a protected building or vehicle is being vandalized or broken into, or when someone presses the manual paging button. The transmitter has a maximum output power of 4 watts as allowed by the FCC.
Mount the E-37EV inside the secure area. The transmitter sends a page signal when triggered. The page signal is received by the small, highly sensitive, lightweight receiver. The receiver beeps or vibrates and colored LEDs indicate the type of trigger event.
The system is easy to install in any type of building or vehicle. The two 1.5V AAA-sized batteries (batteries not included) in the receiver will last approximately one month (5 transmissions/day). The receiver can be programmed to receive page signals from up to 3 separate transmitters and the transmitter can page an unlimited number of receivers.
Parts List
1 x Transmitter 1 x Receiver (model E-37RV) 1 x Wire harness 3 x Mounting screws 1 x Radio antenna adapter cord (18”)
Introduction ......................................................................................................................... 2
Parts List ............................................................................................................................. 2
Dimensions ........................................................................................................................ 2
Specifications ...................................................................................................................... 3
Installation ....................................................................................................................... 3-4
Wiring .................................................................................................................................. 4
Connection Diagram ........................................................................................................... 5
Programming ...................................................................................................................... 5
Audible and Visual Signals Chart........................................................................................ 6
Operation ........................................................................................................................ 6-7
Warning............................................................................................................................... 7
Troubleshooting .................................................................................................................. 8
Also available from SECO-LARM ....................................................................................... 8
Table of Contents
Dimensions
15/16”
(33mm)
41/8”
(105mm)
31/8”
(79mm)
21/8”
(54mm)
3”
(76mm)
5
/8”
(16mm)
2 SECO-LARM U.S.A., Inc.
ENFORCER E-37EV Alarm Pager System
Transmitter Installation
1. Mark locations for drilling the mounting bracket holes. Be careful that the area to be drilled
is free from wiring, trim, and/or any other obstructions.
2. Drill holes at the location marks. Position the transmitter where it will be mounted, but do
not secure immediately.
3. The transmitter should be permanently mounted only after all connections and tests
are made.
NOTES:
Do not mount the E-37EV transmitter in the engine compartment as this automatically voids
the warranty.
Do not power up the transmitter before the antenna connections are made as this may
damage the transmitter.
In a building, mount as close to a window as possible. In a vehicle, mount under the dashboard or in the glove compartment.
Antenna Installation (see Connection Diagram on pg. 5)
The E-37EV can be connected to one of four types of antennas:
TYPE 1: Strip antenna (A Position)
1. E-37ANT (optional) can be used in either a building or vehicle.
2. Connect the male antenna plug into the transmitter jack marked “ANT.”
3. Place the antenna selection switch in the “A” position.
4. Do not secure the strip antenna to metal, window defrosters, or existing antennas.
Installation
Transmitter
Number of codes
Over 2 million (factory pre-set)
Power
12VDC
RF output power
4W max.
Current drain Standby
10mA
Active
1A
Frequency
27MHz
Antenna impedance
50 Ω
Range
Up to 1/2 mile in open air
1
Dimensions
41/8”x31/8”x15/16” (105x79x33 mm)
Weight
5.1-oz (145g)
1
Actual range may vary depending on the environment, installation, and/or antenna.
Receiver
Number of codes
Learns up to 3 transmitter codes
Power
3VDC (2 AAA batteries)2
Battery life
Approx. 1 month3
Current drain Standby
1mA
Active (Beep)
20mA
Active (Vibrate)
50mA
Dimensions
3”x21/8”x5/8” (76x54x16 mm)
Weight
1.6-oz (45g) (without battery)
2
Batteries not included
3
Based on 5 transmissions/day