Seco-Larm ST-BT02Q User Manual

Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.
Manual
6-in-1
12VDC Battery Tester with Continuity
Continuity Voltage Polarity Load Voltage Drop PTC Fuse
6-in-1 Tester
Performs the following tests:
The ENFORCER ST-BT02Q 12VDC 6-in-1 Battery Tester with Continuity is a compact unit that performs six essential troubleshooting tests in the field, including continuity testing. Four individually lit LEDs show the strength of the voltage present from excellent to poor, two separate LEDs show the progress of the test, and one LED shows continuity during continuity testing. The illuminated pigtail connector shows AC, DC, and polarity, while included alligator clips allow easy connection in any situation.
Voltage
AC
ENFORCER 12VDC 6-in-1 Battery Tester with Continuity
IMPORTANT NOTES:
1. DO NOT CONNECT THE ST-BT02Q TO AC POWER. DOING SO WILL VOID THE
MANUFACTURER’S WARRANTY AND MAY PERMANENTLY DAMAGE THE TESTER.
2. THE ILLUMINATED DC JACK LED WILL SHOW PURPLE TO INDICATE AC IS PRESENT. DO
NOT PERFORM ANY TESTS WHEN AC POWER IS PRESENT.
3. THE TESTER IS INTENDED FOR USE WITH 12VDC. DO NOT EXCEED 30VDC. The units power
LED will show a blue color when connected to voltages 21~30 VDC for indication purposes only.
4. Load testing takes no longer than a few seconds. Significant heat is normal when load testing but
pressing the test button for too long will cause the unit to overheat.
5. When load testing, wait 30 seconds between tests to allow the unit to cool.
6. The unit should be stored in Voltage Test mode in order to prevent draining the battery.
LED Strength Indicators:
Illuminated DC jack input:
Female DC jack input connects
directly to 2.1mm jacks for testing.
DO NOT CONNECT AC POWER
Tester Overview:
Mounting hook
Included lead with
alligator clips
Load Test button
Specifications:
Operating voltage
12VDC
Maximum load
0.5 / 1 A (switch selectable)
Power
Continuity test: 3VDC CR1220 type battery
All other tests: Passive, no power required
Weight
1.4 oz (40g)
Dimensions
2" X 13/4" X 11/8" (51 X 44 X 29 mm)
Blue: Excellent
Green: Good
Yellow: Weak
Red: Bad
Red: Input 3~15.6VDC
Blue: Input >21VDC
Tester Status Indicators:
Red: Test Done
LED to indicate continuity when
in Continuity Test mode
Load selection switch:
0.5A / 1.0A
Test mode switch:
Continuity / Voltage
Test #1: Continuity Test
1. Switch the tester to Continuity Test mode using the mode switch on the
upper side of the unit.
2. Ensure the circuit to be tested is unpowered. Using the alligator test leads,
connect the unit across the circuit to be tested. If the circuit is continuous, the red Continuity LED will illuminate.
3. When testing long lengths of wire, it is easiest to test two wires at once.
Connect the wires together at one end, and attach one alligator test lead to each of the other two ends. Be sure the circuit is not live while testing.
4. Always return the tester to Voltage Test mode using the mode switch, or
the battery will drain.
Continuity Testing
SM-204 Magnetic
Contact
2 SECO-LARM U.S.A., Inc.
Loading...