Seco-Larm SS-040Q-BR, SS-040Q-W User Manual

Page 1
MANUAL
Mini Shock/Vibration Detector
The ENFORCER SS-040Q MINI SHOCK/VIBRATION DETECTOR is designed for protection against forced entry by a hammer, saw, crowbar, etc. through walls, ceilings, windows, safes, cabinets, etc. For use in closed-circuit alarm systems, the SS-040Q will initiate an alarm when a vibration of considerable force strikes the protected surface. A built-in tamper switch is independently wired from the vibration detector for enhanced security.
Vibration contacts are adjustable by turning an adjustment screw to respond on any surface ­glass, wood, steel, plasterboard, or brick. Pure silver contact points ensure years of long-term operation. Dust-tight ABS case is small and can be easily mounted inside with two-sided adhesive tape.
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
Page 2
ENFORCER Shock/Vibration Detector
FEATURES INSTALLATION AND OPERATION
SPECIFICATIONS
Circuit:
Normally-closed contact, momentarily open when activated
Contact Pressure:
Adjustable from 1 to 50 grams but recommended setting between
5 and 25 grams only. Supplied with pressure of approx. 6 grams
Current Rating:
1A @ 50VDC.
Break Time:
Approx. 45 ms max. (at 6-gram pressure)
Life:
Over 100,000 contacts
Contact:
Pure silver
Case:
ABS resin
Size:
15mm (H) x 21mm (W) x 60mm (L)
Weight:
20 gms
2. If you choose not to use the tamper switch, fasten the wire to the terminal farther from the
opening, as shown below.
For use in closed-circuit alarm systems. Pure silver contacts ensure reliable and
long-term operation.
Ideal for protecting glass windows,
showcases, solid walls, ceilings, safes, cabinets, motorcycles, skylights, etc.
Small size and for discreet installation.
Built-in tamper switch provides enhanced
security.
Adjustable contact pressure for different
surfaces.
Detects a vibration/shock on protected
surface and activates an alarm.
1. Remove the cover and connect one lead of the wire from the N.C. input of the alarm to the
terminal of the SS-040Q near the opening. Connect the other lead to the terminal of the tamper switch, as shown below.
The SS-040Q will trigger the alarm whenever it is vibrated, shaken, or its cover is removed.
The alarm will trigger only when the SS-040Q is vibrated or shaken.
NOTE: When protecting windows the preferred installation method is to mount the SS-040Q
on the frame of the glass window rather than directly on the glass. This reduces the chance of false alarms resulting from heavy vehicles passing by or from inadvertent tapping on the window by pedestrians.
To alarm unit
Close loop input
Close loop input To alarm unit
2 SECO-LARM U.S.A., Inc.
Page 3
ENFORCER Shock/Vibration Detector
HOW TO ADJUST THE SENSITIVITY
Contact pressure below 5 grams is not recommended, as erratic operation may result and cause false alarms. Contact pressure above 25 grams is not recommended because (a) it may permanently damage the vibration blade; (b) the detector may not be sensitive enough to detect vibration. This depends on the location where the detector is installed. If installed on a ceiling the pressure must be increased. Because the internal weight faces downwards, this reduces the pressure that is applied.
As the SS-040Q can be used surfaces of different materials which transfer different amounts of pressure from the same vibration/shock, it may be necessary to adjust the sensitivity. Turning the adjustment screw (a) in a clockwise direction makes the contact less sensitive, (b) in a counterclockwise direction makes the contact more sensitive. Proper adjustment may be necessary to avoid false alarms or non-activation of the alarm.
To adjust the pressure if a Gram Meter is not available, please do the following:
1. Determine the initial contact point of the vibration detector. This is done by rotating the
adjustment screw in a clockwise direction until the contact points just touch. At this point the pressure is usually approx. 1 gram. (An ohm meter placed across the terminals will show exactly when initial contact is made.)
2. After contact, turn the adjustment screw past the contact point (a) 45 degrees to obtain
approximately 6 grams, (b) 90 degrees to obtain approximately 11 grams, (c) 135 degrees to obtain approximately 16 grams, etc. to obtain the sensitivity you require. Please use figure 1 shown below.
Figure 1: Adjusting Vibration Detector Pressure
SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3
Page 4
ENFORCER Shock/Vibration Detector
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2009 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
MiSS-040Q_0901.docx Order Part # 763-020-2%
PITSW1
Also Available from SECO-LARM:
Entry Alert System
E-931CS22RRCQ Audio Discriminator
For monitoring an entrance or use as an
entrance indicator
Retro-reflective beam sensor. Range up to 22 feet.
E-190
Covers an area 45 feet in front and
25 feet to either side.
Incorporates SECO-LARMs
patented yellow turbulence LED.
Twin or Quad Photobeam Detectors
E-964-D90Q
Twin beams available in ranges up to
90, 190, 290, and 390 feet.
Quad beams available in ranges up to
165, 330, 495, and 660 feet.
Reflective-Beam Sensor
E-931-S35RRQ
For garage doors, outdoor gates or overhead
doors or as a sensor for industrial automation.
Weatherproof (IP66) design for indoor/outdoor
applications
(shown)
SECO-LARM carries a complete line of security products.
For more information please visit www.seco-larm.com
4 SECO-LARM U.S.A., Inc.
Loading...