Model Solenoid Operating voltage Color SD-961A-36GQ No N/A Silver SD-961B-36GQ No N/A Black SD-961D-36GQ No N/A Dark bronze SD-961A-36GSQ Yes 12~24 VAC/VDC Silver SD-961B-36GSQ Yes 12~24 VAC/VDC Black SD-961D-36GSQ Yes 12~24 VAC/VDC Dark bronze
ENFORCER Electromechanical Push Bars feature a double-locking spindle for stronger and more secure locking. All models include a cylinder lock for keyed entry and some models offer solenoid­actuation to allow unlocking and relocking by an access control device.
Double-locking spindle (stronger and more secure)
Available in manual or solenoid-actuated versions
Solenoid rated for both continuous and intermittent operation
Aluminum alloy construction in a reversible, non-handed design
Fail-Secure operation (but can be opened from inside by pressing the bar)
Lock status monitoring for returning status to the access control system
Mortise lock cylinder and keys included to release the lock from the outside
Dogging latch on push bar to hold open
Includes all needed hardware for typical installations
Page 2
Electromechanical Push Bars
1x P
ush bar
2x
Flat-head screws
1x
Dogging keyhole cap
1x
Dogging key
1x Mounting template
4x
Round
-
head screws
4x
Mounting screw caps
1x
Manual
Strike Assembly
1x Strike plate
2x
Strike spacers
1x
Flat-head wood screw
1x
Hex tool
1x Hex wrench
2x
Blind nuts 2x Flat-head machine screws
Lock Assembly
1x Lock cylinder
2x
Screws
1x
Cylinder plate
1x
Cylinder guard
3x
Keys*
Push bar and strike
not drawn to
scale
Dogging keyhole
"
27/16"
(
61.5
mm)
Turn counter
-
clockwise
for unlimited access
Turn clockwise for
controlled
access
Parts List
*
No replacement keys available. Please keep a backup key in case of loss.
Specifications
Model SD-961A-36GQ SD-961B-36GQ SD-961D-36GQ SD-961A-36GSQ SD-961B-36GSQ SD-961D-36GSQ
Operating voltage
Current draw N/A 1.5A@12VDC, 0.5A@12VDC after 3 seconds
Entrance External keyed lock External keyed lock or access device
Endurance N/A Over 500,000 cycles
Contact load 5A@125VAC
Output Form "C" (NO/NC/COM) door monitor
For doors 36" (91.5cm), minimum 327/8" (83.5cm), wood or metal, non-handed
Latch Double locking spindle
Color Silver Black Dark bronze Silver Black Dark bronze
Material Anodized aluminum
Dimensions 27/16"x29/16"x351/16" (61.5x65x890 mm)
Weight 5-lb 10-oz (2.56kg) 6-lb 6-oz (2.88g)
N/A 12~24 VAC/VDC
Overview
Push bar
29/
16
(65mm)
351/16"
(890mm)
Strike
13
/16"
111/16"
(42.5mm)
23/4"
(69mm)
(21mm)
1
/2"
(13mm)
Dogging the Push Bar
Remove dogging keyhole cover and insert dogging key.
2 SECO-LARM U.S.A., Inc.
Dogging Open Dogging Closed
Page 3
Electromechanical Push Bars
Metal Door
ø11/4" (
ø32mm)
(outside only)
ø3/8" (ø9.5mm)
ø11/4" (ø32mm)
(through door)
Blind nuts x2
Ensure the device is
installing 3
screw
Spacer(s) (as needed
(2 included)
Strike
Hex wrench
Washer
Blind nut
Hex screw
Hex tool
Door frame
Hold with wrench while
turning hex screw
Installation
Please read the entire manual carefully before beginning installation
1. Measure and draw a horizontal line on the inside of
the door 40" (102cm) above the floor or according to local regulations. This will be the push bar centerline.
2. Use the supplied metal template to mark lines for
cutting away the stop for the strike assembly and all mounting holes and lock cylinder holes. Measure carefully to mark the two holes away from the locking mechanism, noting the different spacings (see Fig. 1).
3. Drill 3/16" (4mm) mounting holes and other holes in the
door and install lock assembly, ensuring the spindle extends at least 3/16" (5mm) (see Fig. 2 for metal doors and Fig. 3 for wood doors).
4. Remove end cap screws and remove end caps. Slide
the push bar off the base to access the terminals.
5. Thread the wiring through the wiring hole near the
terminals. Install the push bar base (see Fig. 4) and connect wiring (see Sample Application and Wiring Diagram on pg. 4). Slide the push bar back into place and replace the end caps.
6. Drill the two blind nut holes, precisely 1/4" (7mm), for
the strike assembly (see Fig. 5).
NOTE: The holes must be drilled to the precise size.
7. Insert a blind nut, put the washer on the hex screw
followed by the hex tool (see Fig. 6). Turn the screw by hand into the blind nut. Use a wrench to hold the hex tool and slowly tighten the hex screw with the included hex wrench until it becomes difficult to turn. This compresses the blind nut so that it remains permanently fixed. Remove the hex screw and hex tool and repeat for the other blind nut.
Fig. 1
Fig. 2
Fig. 3
Cylinder plate
Fig. 4
3" (76mm)
40"
(102cm)*
*Or local regulations
327/8"
(834.6mm)
17/16" (36mm)
11/4" (32mm)
Wood Door
Fig. 5
ø1/4" (ø7mm)
x2
3" (76mm)
2" (50mm)
to adjust position)
operating smoothly before drilling and
rd
Fig. 6
SECO-LARM U.S.A., Inc. 3
Page 4
Electromechanical Push Bars
+
Access control
PB
PB
N.O.
COM
N.C.
+
Lock status output
12~24 VAC/VDC
Brown N.O.
Green COM
White N.C.
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
year from the date of sale
prepaid, to
trical misuse or abuse, neglect, repair or alteration, improper
LARM determines that such equipment is not operating properly as a res ult of causes other
LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair
personal or property damage of any kind
LARM reserves the right to change specifications without
These products may contain chemicals which are known to the State o f California to cause cancer and birth defects or other
nal, state,
user customer to
" (4~5 mm)
Strike
End cap
Installation (Continued)
8. Install the strike assembly as shown in Fig. 5 on pg. 3. Ensure a
3
/16" (4~5 mm) gap between the strike assembly and end cap
(see Fig. 7). Use included spacers as needed.
9. Ensure the push bar and strike are operating smoothly and the
locking spindle teeth fully engage the strike before tightening the two main strike assembly screws. Drill and install the middle screw as the final step (see Fig. 5 on pg. 3).
Fig. 7
3
/
16
Wiring Diagram
SD-961x-36GQ Series Manual Push Bars
Connection to Lock Status Indicator
Lock status
indicator
Relay rating
5A@125VAC
When connecting solenoid-actuated models to an access control system or a control device, note that the latch retraction duration is controlled by the connected N.O. switch.
SD-961x-36GSQ Series Solenoid-Actuated Push Bars
Connection to Access Control Device
N.O.
Access
COM
Control
Keypad /
Proximity
+
Reader
Power Supply
12/24
VAC/VDC
Connect lock status output according to status indicator directions
Troubleshooting
Bar does not unlock when triggered (models with solenoid)
Buzzing sound when activated (models with solenoid)
Device does not unlock
WARNING: The push bar is not weatherproof. Do not mount on exterior surface or where exposed to rain.
IMPORTANT: The height at which the push bar is mounted may be subject to local regulations. It is the responsibility of the installer and/or end-
ensure the push bar meets all local regulations regarding the use of push bars for access security, including height, suitability for doors accessed by disabled persons, and suitability for fire doors (the push bar is not fire-rated).
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all natio and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
California Proposition 65 Warning:
reproductive harm. For more information, go to www.P65Warnings.ca.gov.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1)
to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation SECO-LARM. This Warranty is void if damage is caus ed by or attributed to acts of God, physical or elec or abnormal usage, or faulty installation, or if for any oth er reason SECO­than defects in material and workmanship. The sole obligation of SECO­only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO­notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2022 SECO-LARM U.S.A., Inc. All rights reserved.
SECO-LARM
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
®
U.S.A., Inc.
Check the input voltage (12~24 VAC/VDC)
Check that the trigger switch is operating properly
This may sometimes result when using AC voltage. Change to DC
if it persists
Check back pressure on latch and adjust