Featuring:
Built-in Timer (0.5~30 seconds or toggle)
Programmable LED (Red to Green or Green to Red)
Outdoor No Touch
Request-To-Exit Sensor
Manual
The ENFORCER Outdoor No Touch Request-To-Exit Sensor is a full-featured exit plate which
uses IR technology to allow egress from a protected area or activate a device with the simple
wave of a hand. Since it is No Touch, this sensor is ideal for use in hospitals, clinics, labs,
cleanrooms (to reduce the risk of contamination), schools, factories, or offices.

ENFORCER ® No Touch Request-To-Exit Sensor
Adjustable sensor range up to 7" (18cm).
Weather resistant for outdoor use.
Stainless steel plate.
1A relay, adjustable trigger duration 0.5~30
seconds or toggle.
LED illuminated sensor area for easy
identification.
Selectable LED colors (turns from red to
green or green to red) to show sensor
activated.
Form C dry contact, 1A@30VDC
Single Gang
w/ Mechanical Override
Slimline
w/ Mechanical Override
Form C Mechanical override1
1
SD-9163-KSVQ and SD-9263-KSVQ
Features:
Overview:
Specifications:
2 SECO-LARM
2
Color function reversible
3
Front panel only.
®
U.S.A., Inc

Standby: Green
Trigger: Red
Standby: Red
Trigger: Green
(default)
Place here for:
Standby: Green
Trigger: Red
Place here for:
Standby: Red
Trigger: Green
(default)
Wiring for No Touch Sensor
(SD-9263-KSQ shown)
Wiring for No Touch Sensor
with Form C Mechanical Override Button
(SD-9263-KSVQ shown)
4
Set trigger time to maximum
Trigger time: 0.5~30 seconds, toggle4
Default: 0.5 seconds
4
Toggle: turn all the way clockwise
Sensor range: 2”~7” (5~18 cm)
Default: 7” (18cm)
ENFORCER ® No Touch Request-To-Exit Sensor
Wiring Diagram:
Installation:
1. Run four wires through the wall to a single-gang or slimline back-box.
2. Connect the four wires from the back-box to the Request-to-Exit
Sensor according the Wiring Diagram above.
3. Screw the plate into the back-box, taking care not to crimp the wires.
4. Remove clear protective film from the sensor before use.
WARNING: Do not connect any device that will exceed 1A@30VDC.
Changing the LED Color Jumper Placement:
Slimline Models Single-Gang Models
Adjusting the sensor range and trigger time:
1. The sensor range can be adjusted from 2”~7” (5~18 cm).
2. The trigger time can be adjusted from 0.5 to 30 seconds or toggle
NOTE: Do not force the adjustment trimpots to turn. Only minimal
force is needed.
SECO-LARM
®
U.S.A., Inc 3
4
.

ENFORCER ® No Touch Request-To-Exit Sensor
MiSD-9x63-KSxQ_1405.docx
Order Part # 763-171-5%
Override button is prewired in the factory
No further wiring necessary
Example Installation:
Typical installation with an electric lock:
Care and Cleaning for the SD-9x63 Series Sensor:
The sensor requires special care to ensure reliability and a long operating life.
1. Use a soft, clean cloth for cleaning. Use the mildest type of cleaner available.
2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
3. Be sure to wipe off any excess liquid from the sensor. Wet spots or areas may affect the
sensor’s performance.
WARNING: Incorrect mounting which leads to exposure to rain or moisture inside the enclosure
could cause a dangerous electric shock, damage the device, and void the warranty.
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in
normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse,
neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason
SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in
material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or
repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental,
or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM
reserves the right to change specifications without notice.
SECO-LARM is not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied,
in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tél: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 Email: sales@seco-larm.com
4 SECO-LARM
®
U.S.A., Inc.
®
U.S.A., Inc