30W PoE Injector
NJ-A301U-T6AQ
Installation Manual
ENFORCER 30W PoE Injector converts 100~240 VAC to low voltage DC and supplies power to
cameras, IP access control, and other PoE devices using Cat5e or Cat6 cables. This allows you to
supply power to IEEE 802.3af/at compliant network accessories without an external power supply
and provides a compact, reliable, and affordable solution to your networking infrastructure.
• Supports up to 30W on 2-pairs
• LED indicates power supply input and PoE output
• Internal AC/DC converter
• Easy Plug-and-Play installation
• Connects 10,100,1000BaseT PoE devices
• Overcurrent, overload, overvoltage, and anti-interference protection
• Supports Cat5e network cables and higher
• Compliant with IEEE 802.3af/at standard

ENFORCER 30W PoE Injector
Parts List
Specifications
Operating voltage 100~240 VAC
Connections
Data In 1x Shielded RJ45
PoE Out 1x Shielded RJ45
PoE Power output Up to 52VDC, 30W
Power link Pin 1/2 (–), 3/6 (+) up to 30W
Network cables Cat5e or higher
Protection Overcurrent, overload, overvoltage, anti-interference
Ethernet speed 10/100/1000 Mbps
LED Indicator Green – power in, red – power out
Operating humidity 90% (Maximum, non-condensing)
Operating temperature 14°~104° F (-10°~°40 C)
Dimensions 43/4"x2"x17/16" (121x50x36 mm)
Overview
AC In
17/16"
(36mm)
Data In
2"
(50mm)
43/4"
(121mm)
P+DATA
DATA
PoE Out
OUTPUT
IN
LED
NOTES:
• LED steady green indicates the PoE Injector has power.
• LED steady red indicates the device connected to the P+DATA port is powered.
2 SECO-LARM U.S.A., Inc.

ENFORCER 30W PoE Injector
Installation
1. Use a CAT5e/6 UTP cable to connect device to the PoE Injector’s DATA IN port.
2. Connect the AC power cable to the PoE Injector and power source.
3. Connect the PoE OUT port to a PoE Device with CAT5e/6 UTP cable.
Sample Application
PoE Cameras or other PoE devices
Ethernet
Switch
P+DATA
OUTPUT
IN
DATA
NVR
SECO-LARM U.S.A., Inc. 3

ENFORCER 30W PoE Injector
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
s permitted. Any change to the antenna
Users and installers of this product are responsible for ensuring this product complies with all national, state, and local laws an
Users and installers of this product are responsible for ensuring that the installation and configuration of this product com
plies with all national, state,
California Proposition 65 Warning:
These products may contain chemicals which are known to the State of California to cause cancer and birth defects or
LARM product is warranted against defects in material and workmanship while used in normal service for
one (1) year from the date of sale
to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to
LARM determines that such equipment is not operating properly as a result of causes other
exclusive remedy, shall be limited to the replacement or repair
LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any
LARM policy is one of continual development and improvement. For that reason, SECO LARM reserves the right to change specific
16842 Millikan Avenue, Irvine, CA 92606
Troubleshooting
PoE device doesn't function properly
• Ensure that all devices are turned on
• Ensure that the PoE device is functioning by plugging it directly
into the PoE switch, computer, etc.
• Double-check that the cables were connected properly
• Run a continuity test on all wires in the cable
• Equipment at both ends must be at the same link speed,
10BaseT with 10BaseT, 100BaseT with 100BaseT, etc.
• Replace with a higher-grade cable for better performance
• Ensure that the cable lengths are within the allowable range and
consistent with the remote PoE device power consumption, and
reduce cable length as needed
• Check that power consumption is within the specifications
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1)
NOT CAUSE HARMFUL INTERFERENCE AND (2)
CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device i
or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.
monitoring and recording audio and video signals. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or statutes.
and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
reproductive harm. For more information, go to www.P65Warnings.ca.gov.
to the original customer. SECO-LARM’s obligation is limited
SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, phy sical or electrical misuse or abuse, neglect, repair or alterati
or abnormal usage, or faulty installation, or if for any other reason SECOthan defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s
only, at SECO-LARM’s option. In no event shall SECOkind to the purchaser or anyone else.
notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2023
SECO-LARM U.S.A., Inc. All rights reserved.
SECO-LARM
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
®
U.S.A., Inc.
MI_NJ-A301U-T6AQ_230624.docx
PICSN7