Seco-Larm EVT-PB1-L05Q User Manual

Page 1
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
MANUAL
EVT-PB1-L05Q
Video, Power and Data Balun
with Voltage Converter
Transmit video up to 2,000’ over Cat5 Selectable 5/12/24VDC output via jumper Regulated and filtered output. Output current protection – 500mA Built-in overload protection.
Dual-colored LED power output indicator:
Red: 5/12VDC Blue: 24VDC
Green power input LED indicator. Small size for easy installation.
The ENFORCER EVT-PB1-L05Q Video, Power and Data (VPD) Balun with Voltage Converter combines the flexibility of a VPD Balun with the ability to convert AC or DC voltage for use in low voltage DC applications. The VPD balun with voltage converter changes 12/24VAC/VDC input voltage to a regulated 5/12/24VDC adjustable output voltage. Converted DC power is regulated to provide stable power suitable for voltage sensitive cameras.
Page 2
ENFORCER Video, Power and Data Balun with Voltage Converter
Specifications:
Figure 1: Video, Power and Data Balun with Voltage Converter Detail
Power +
Power –
Video +
Video –
Data +
Data –
VDC out
Video in
Data out
EVT-PB1-L05Q
Voltage Converter
Output voltage
5/12/24VDC selectable by jumper (default 12VDC)
Operating voltages
Input voltage
Regulated output voltage
8 ~ 30VDC/VAC
5VDC
15 ~ 30VDC/VAC
12VDC
24 ~ 27VDC/VAC
24VDC
Output current
500mA @ 5/12/24 VDC
Voltage input LED indicator
Green
Voltage output LED indicator
Red
5/12VDC
Blue
24VDC
Current protection
PTC 500mA
Video
Range
2,000’ (610m) B/W, 1,300’ Color (400m)
Video format
RS170, NTSC, PAL, SECAM, CCIR
Maximum input
1vp~p
Insertion loss
< 2dB per pair from DC ~ 5 Mhz
Return loss
>-15dB from DC ~ 5 Mhz
Common mode rejection
60dB, 15KHz~5MHz
Frequency response
DC ~ 5 Mhz
Power
No power required for video
Connections
Wire type
UTP (unshielded twisted pair)
Wire category
20 - 24 AWG @ screwless terminal blocks
CAT2 or better, CAT5 ideal, CAT6 improves range
Connectors
In
Removable terminal block
Out Video
Pigtail BNC
Power
Pigtail DC plug (center pin positive)
Data
Wire
Attenuation
DC ~ 5 Mhz, 1.5 dB max
Impedance
Coax, male BNC: 75 Ohms@ 1 MHz
Terminal block: 100 Ohms @ 1 MHz
Other
Dimensions
3 1/4" x 2 9/16" x 3/4" (81 x 65 x 20mm)
Humidity range
0 ~ 95%
Temperature Range
14°~165°F (-10°~74°C)
Case
ABS Plastic
Dual-colored output LED
Power input LED
Voltage selection jumper
Adjustable output voltage knob
2 SECO-LARM U.S.A., Inc.
Page 3
ENFORCER Video, Power and Data Balun with Voltage Converter
1. Run UTP cable to the camera where the VPD balun is being installed.
2. Remove the cover by simultaneously pressing down on the top cover, and lifting up on the side
mounting tabs. This will release the tight seal between the top and bottom covers.
3. Set the desired output voltage using the selection jumper according to table 1 below.
4. Connect the output wires from the power supply to the power input terminal blocks on the VPD
balun. Observe correct polarity.
5. Apply power and use table 2 and 3 below to check the status of the input and output voltages.
NOTE: To avoid potential damage, use a voltage meter to ensure proper voltage is present at the input and output terminal blocks. Observe correct polarity.
6. Connect the camera to the DC plug on the balun.
7. If the output voltage is low, then turn the rotary knob clockwise to increase the voltage or
counter-clockwise to decrease the voltage.
8. Connect the video input male BNC input in from the VPD Balun to the camera.
9. If using a RS-485 controlled camera, connect the data in wires to the camera.
10. Using the remaining terminal blocks, connect the data and video wires to the balun according to
Figure 1.
IMPORTANT: Correct polarity must be observed on all connections.
11. Replace the cover on the voltage converter.
Figure 1: Sample Application
Installation:
Table 1: Adjustable Output Voltage
Table 3: LED Indicators
Input Voltage
Output Voltage
Adjustable Voltage Range
Jumper Settings
8~30VDC/VAC
5VDC
4.5 ± 5%VDC
15~30VDC/VAC
12VDC
12.6 ± 5%VDC
24~30VDC/VAC
24VDC
24.0 ± 5%VDC
LED colors
Status
Green
Input power is connected
Red
Output voltage is 5 / 12VDC
Blue
Output voltage is 24VDC
NOTE: To avoid potential damage, use a voltage meter to
ensure proper voltage is present at the input and output terminal blocks. Observe correct polarity.
SECO-LARM
Video Balun
Table 2: Wiring Distance 12
VDC Voltage Drop
24 AWG Wire
1 Pair
2 Pairs
3 Pairs
250mA
90'
220'
550'
500mA
45'
110'
285'
750mA
30'
75'
190'
1A
20'
55'
140'
Data out
Video in
VDC out
DVR
PTZ
Controller
Cat5 cable
EVT-PB1-L05Q
ST-2406-7A Power Supply
SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3
Page 4
ENFORCER Video, Power and Data Balun with Voltage Converter
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
mi-EVT-PB1-L05Q.docx
Troubleshooting:
PITSW1
Output voltage is low/high
Check output voltage jumper settings. Check output voltage adjustment. Check input voltage to make sure it meets the input
requirements
Green input LED not on
Check input power connections with multimeter to verify
correct input voltage
Blue/red output LED not on
Check to see if the load exceeds the maximum limit Temporarily disconnect power input and output wires for 30
seconds before connecting
Also Available from SECO-LARM:
Passive VGA Balun
Passive & Active
Video Baluns
EVT-PB1Q
EVT-SBP-GQ
VPD Balun with
Voltage Booster
EVT-PB1-H05Q
Video Distributors
Voltage Converter
Voltage Booster
ST-HB105-TTQ
ST-LA110-TTQ
VA-1104B-WQ
Video Amplifiers
VA-2101B-WQ
VC-1BAQ
BNC-to-VGA
Converter
(shown)
4 SECO-LARM U.S.A., Inc.
Loading...