NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
Video, Power and Data Balun
with Voltage Converter
Transmit video up to 2,000’ over Cat5
Selectable 5/12/24VDC output via jumper
Regulated and filtered output.
Output current protection – 500mA
Built-in overload protection.
Dual-colored LED power output indicator:
Red: 5/12VDC
Blue: 24VDC
Green power input LED indicator.
Small size for easy installation.
The ENFORCER EVT-PB1-L05Q Video, Power and Data (VPD) Balun with Voltage Converter
combines the flexibility of a VPD Balun with the ability to convert AC or DC voltage for use in low
voltage DC applications. The VPD balun with voltage converter changes 12/24VAC/VDC input
voltage to a regulated 5/12/24VDC adjustable output voltage. Converted DC power is regulated to
provide stable power suitable for voltage sensitive cameras.

ENFORCER Video, Power and Data Balun with Voltage Converter
Figure 1: Video, Power and Data Balun with Voltage Converter Detail
5/12/24VDC selectable by jumper (default 12VDC)
Voltage input LED
indicator
Voltage output LED
indicator
2,000’ (610m) B/W, 1,300’ Color (400m)
RS170, NTSC, PAL, SECAM, CCIR
< 2dB per pair from DC ~ 5 Mhz
No power required for video
UTP (unshielded twisted pair)
20 - 24 AWG @ screwless terminal blocks
CAT2 or better, CAT5 ideal, CAT6 improves range
Pigtail DC plug (center pin positive)
Coax, male BNC: 75 Ohms@ 1 MHz
Terminal block: 100 Ohms @ 1 MHz
3 1/4" x 2 9/16" x 3/4" (81 x 65 x 20mm)
Adjustable output voltage knob
2 SECO-LARM U.S.A., Inc.

ENFORCER Video, Power and Data Balun with Voltage Converter
1. Run UTP cable to the camera where the VPD balun is being installed.
2. Remove the cover by simultaneously pressing down on the top cover, and lifting up on the side
mounting tabs. This will release the tight seal between the top and bottom covers.
3. Set the desired output voltage using the selection jumper according to table 1 below.
4. Connect the output wires from the power supply to the power input terminal blocks on the VPD
balun. Observe correct polarity.
5. Apply power and use table 2 and 3 below to check the status of the input and output voltages.
NOTE: To avoid potential damage, use a voltage meter to ensure proper voltage is
present at the input and output terminal blocks. Observe correct polarity.
6. Connect the camera to the DC plug on the balun.
7. If the output voltage is low, then turn the rotary knob clockwise to increase the voltage or
counter-clockwise to decrease the voltage.
8. Connect the video input male BNC input in from the VPD Balun to the camera.
9. If using a RS-485 controlled camera, connect the data in wires to the camera.
10. Using the remaining terminal blocks, connect the data and video wires to the balun according to
Figure 1.
IMPORTANT: Correct polarity must be observed on all connections.
11. Replace the cover on the voltage converter.
Figure 1: Sample Application
Table 1: Adjustable Output Voltage
Output voltage is 5 / 12VDC
NOTE: To avoid potential damage, use a voltage meter to
ensure proper voltage is present at the input and
output terminal blocks. Observe correct polarity.
Table 2: Wiring Distance 12
VDC Voltage Drop
SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3

ENFORCER Video, Power and Data Balun with Voltage Converter
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only,
at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in
whole or in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
Output voltage is low/high
Check output voltage jumper settings.
Check output voltage adjustment.
Check input voltage to make sure it meets the input
requirements
Check input power connections with multimeter to verify
correct input voltage
Blue/red output LED not on
Check to see if the load exceeds the maximum limit
Temporarily disconnect power input and output wires for 30
seconds before connecting