Installation Manual
®
ENF ORCER
ST-HB105-TTQ
Voltage Booster
Introduction:
The ENFORCER voltage booster is a step-up voltage booster. When running DC voltage over long cable runs,
a voltage drops occurs. The ENFORCER voltage booster will boost the voltage to the required operating
voltage to meet the system’s needs. It is useful for CCTV DC cameras, access controls, as well as many other
applications where voltage drop is an issue.
Features:
• Compensate DC voltage drops over long cable runs.
• Built-in overload and short-circuit protection.
• Regulated and filtered output.
• Output current protection: 500mA.
• Selectable 12 or 24 VDC output via jumper.
1. Remove the cover by tightly pressing the terminal
block’s holes and pushing the side mounting
brackets outwardly.
2. Set the desired output voltage to 12 or 24 VDC.
See table 3. The factory default output setting is
12 VDC.
3. Turn on the power of the power supply. Connect
the output wires from the power supply to the
power input terminal blocks. See specification
chart for the power requirements.
4. Use table 2 to check the LED status for the input
and output voltage.
5. To avoid potential damage, use a voltage meter
to check if the voltage reading at the input and
output terminal blocks is correct.
Observe correct polarity.
Note: 1. Use between 16 AWG and 26 AWG wire
for the input and output terminal blocks.
2. Use the included SECO-LARM DC
pigtail connector for easy installation.
6. Connect device to the power output terminal blocks.
7. If the output voltage is low, then turn the rotary
knob clockwise to increase the voltage or counterclockwise to decrease the voltage.
Note: If the output voltage set by the jumper is
higher than the input voltage, then the output
voltage stays the same.
8. Replace the plastic cover on the voltage booster
and secure it in the desired location.
• Dual-color LED power output indicator:
– Red indicates a 12 VDC output.
– Blue indicates a 24 VDC output.
• Green power input LED indicator.
• Small size for easy installation.
Specifications:Installations:
Output voltage:
Input voltage:
Maximum output current:
LED indicators:
Current
Connector:
Overload protection:
Short circuit protection:
Size:
* This ENFORCER voltage booster’s efficiency rate is 85%. For more information,
please visit www.seco-larm.com for further details.
Table 1: Adjustable voltage output chart
Output voltage Adjustable voltage range
12 VDC
24 VDC
12 or 24 VDC, selectable by jumper
7~12 VDC for 12 VDC
12~24 VDC for 24 VDC
500mA*
Power output LED (red for 12 VDC, blue for 24 VDC)
Power input LED (green)
PTC (Positive Temperature Coefficient)
Terminal blocks
Built-in
Built-in
3
2
4
x 2” x
(64 x 50 x 19mm)
”
/
”
21/
12.2 ~ 13.5 VDC
23.0 ~ 25.2 VDC
Table 2: LED indicator chart
LED colors
Green
Red
Blue
Indications
Input power is connected.
Output voltage is 12 VDC.
Output voltage is 24 VDC.
Table 3: Output voltage selection chart
Output
voltage
12 VDC
24 VDC
Jumper setting
A B C

Figure 1 - Wiring diagram
Green input LED status indicator
Power input
Troubleshooting:
Problem
Output voltage is low.
Green input LED not on.
Blue/red output LED not on.
Output power too high.
Multi-color output LED status indicator
(+)
12
24
(-)
(+)
Power output
(-)
Adjustable output voltage rotary knob Output voltage jumper (see table 3)
Solution
• Check jumper settings.
• Check/Adjust output voltage adjustment.
• Check input voltage - make sure it meets the input
voltage requirements.
(See specification chart).
• Check input power connections with multimeter.
• Check to see whether the loading exceeds the
maximum limit.
• Temporarily disconnect the power output wires and then
reconnect them after 30 seconds.
• Check output voltage adjustments.
• Check output voltage jumper settings.
Products also available from SECO-LARM:
ST-LA105-TTQ
ST-LA110-TTQ
• Voltage converter.
• Selectable 5, 12, or 24 VDC output
via jumper.
• Output current protection:
– 0.5 Amp for ST-LA105-TTQ
– 1.0 Amp for ST-LA110-TTQ
• Dual-color LED to indicate output
voltage.
• Built-in overload protection.
• Regulated and filtered output.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and
improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to
the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty
installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable
for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
SECO-LARMSECO-LARM
SECO-LARM
SECO-LARMSECO-LARM
®
U.S.A., Inc., U.S.A., Inc.,
U.S.A., Inc., 16842 Millikan Avenue, Irvine, CA 92606
U.S.A., Inc., U.S.A., Inc.,
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
• Passive balun with built-in power
• Video, power, and data (VPD) over Cat5.
• Built-in power converter that converts
• Built-in multi-color LED indicates
• Built-in DC-plug power connector
EVT-PB1-L05Q ST-2406 Series
converter.
24 VAC to 12 VDC (500mA).
power is on and polarity is correct.
and data wire.
Website: www.seco-larm.com
E-mail: sales
• Power supply/charger modules.
• Converts low-voltage AC to
low-voltage regulated DC.
• Choose 6, 12, 24 VDC for DC
voltage.
• Adjustable voltage output.
• Available in 1.5 A, 2.5A, 4.0A, 7.0A,
9.0A for continuous supply current.
• Regulated and filtered output voltage.
• Built-in backup battery charger.
@