SB-L10V1-20Q
Plug-and-Play Backup Power
Manual
ENFORCER Plug-and-Play In-line Backup Power provides automatic continuous power to
CCTV cameras, routers, modems, VOIP phone systems, employee time and attendance
systems, alarm systems, or other small electronic devices during power outages. In addition, it
includes protection against short-circuits and power surges. The high quality lithium polymer
battery is also protected from short-circuit, overcharge, over-discharge, and overload.

ENFORCER Plug-and-Play Backup Power
2 SECO-LARM U.S.A., Inc.
Overload and short-circuit fuse
Auto-configure 5/7.5/9/12VDC±5%
Over-discharge, overload, short-circuit protection
Lithium Polymer 3.7VDC/2000mAh
Overcharge, over-discharge, overload, short-circuit
Voltage, power, alarm, backup
33/8"x21/4x"121/32" (85x57x42mm)
Real-time backup power with no break
when input power is lost
DC UPS Auto-start
LED indicators for power and charging
2000mAh lithium polymer
Over-discharge, overcharge, overload,
short-circuit, and surge protection
Auto-recognize voltage (5/7.5/9/12VDC)
input and sets corresponding output
Additional indicator LEDs for output voltage
and alarm (alarm is also audible)
On: Indicates detected input voltage and
supplied output voltage
On: Overload, input voltage out of range, or, input voltage
failure, Flashing: Battery low
*Audible alarm – Continuous long beep indicates alarm or failure (see troubleshooting), 5 short beeps indicate transferring to backup

ENFORCER Plug-and-Play Backup Power
SECO-LARM U.S.A., Inc. 3
Note: For devices with non-standard DC plugs, DC plug adapters (not included)
may be needed. Do not cut the DC plug cord as warranty will be voided.
Note: To reach full power backup time, please allow the unit's battery to charge for
at least 24 hours.
1. Disconnect the original power adapter from the device to be powered and plug it into the
In-line Backup Power unit. The correct voltage for the powered device will be automatically
detected and the voltage indicator LED should light up showing the correct voltage.
2. Connect the In-line Backup Power unit's output line to the device to be powered. The voltage
indicator LED should light within 5 seconds for the correct supplied voltage and the “power”
LED should also be lit.
3. To test installation, unplug the adapter from the AC wall outlet momentarily. The yellow
“Backup” LED should be lit and 5 short “beeps” will indicate that backup mode has started.
The device should remain powered. Continuous short “beeps” with the flashing red “alarm”
LED indicates a low battery.
Note: If the In-line Backup Power unit is later used for another device, be sure to press
the ‘off/reset’ button before installation to allow it to again detect the correct voltage.
*DC plug adapters (not Included) may be required for devices which do not accept standard 2.1mm DC plugs.
UPS with battery and power cord

ENFORCER Plug-and-Play Backup Power
4 SECO-LARM U.S.A., Inc.
Backup time is shorter than
claimed
On initial installation, be sure that batteries have been charged for
24 hours before testing backup time
The power plug does not fit my
unit
You may need to provide a power tip adapter to connect to your
device (two adapters, both male and female)
Device does not turn on when
installed
Check to see that all plugs are firmly connected at the device, the
Backup Power unit, power adapter, and the AC wall outlet
Check to see that the AC outlet is live
Ensure that the Backup Power unit's power LED is lit
Check for a short or overload. The Backup Power unit is designed
to cut power when a short-circuit or overload is detected
Check that the device’s voltage is compatible (either 5, 7.5, 9, or
12VDC)
Press the “Off/Reset” button to reset voltage output
During a power outage, power is
not provided to device
Check for a short or overload. The Backup Power unit is designed
to cut power when a short-circuit or overload is detected
The alarm sounds (long beep) and
the red alarm LED is lit
Ensure that the input voltage is either 5, 7.5, 9, or 12VDC
Ensure that the original power adapter is working and providing
power to the Backup Power unit
Ensure that the device's current draw is no more than 10W
Check for a short-circuit at the device
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for 1 (one) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints.
Copyright © 2015 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
MiSB-L10V1-20Q_151120.docx