12VDC Switching CCTV Power Supply
Manual
Model
Number
Number of
Outputs
Total Supply
Current
Max. Current
per Output
PC-U0405-PULQ 4 5A 1.6A
PC-U0910-PULQ 9 10A 1.6A
PC-U1810-PULQ 18 10A 1.1A
PC-U1820-PULQ 18 20A 1.6A
PC-U1830-PULQ* 18 30A 1.85A
*Special order item. Please contact SECO-LARM for details.

ENFORCER 12VDC Switching CCTV Power Supply
2 SECO-LARM U.S.A., Inc.
current
5A 10A 10A 20A 30A
output
1.6A 1.1A 1.6A 1.85A
VDC (adjustable by trimpot
Green: AC Input, Red: DC Output
humidity
90% (non-condensing)
temperature
32°~104° F (0°~40° C)
97/16"x101/4"x23/8" (240x260x60 mm)
/16"x31/8" (254x262x79 mm)
(2.84kg)
*UL listed for 90~120 VAC
**Power distribution module
100~220 VAC Input*
• New lightweight, cost-effective design
• Improved efficiency
• Adjustable output to reduce voltage drop
Outputs protected with PTC fuses
• Individual output status LEDs
• Heavy-duty steel case with cover
• Built-in short circuit and overheat protection
Power output switch
Power input socket

ENFORCER 12VDC Switching CCTV Power Supply
SECO-LARM U.S.A., Inc. 3
Fig. 2 - Power Input Socket
1. Find a suitable location to install the power supply.
The power supply should be installed out of sight,
and in a place protected from weather and high
humidity. The power supply must have adequate
ventilation. Insufficient ventilation may cause
overheating and damage could result.
2. Remove one of more of the cable knock-outs,
depending on how many connections will be made.
Knock-outs are shown in Fig. 1 to the right. If
desired, use an optional bushing, grommet, or other
sleeve to protect wires passing through the hole(s).
3. Screw the power supply to the wall or other mounting
surface using 5/32"x1" (4x26 mm) screws and plastic
anchors (not included). First, screw in the top
screw(s) and hang the power supply. Then, if
applicable, screw in the bottom two screws to fully
secure the unit in place.
4. Plug the power cable into the power input socket
(Fig. 2).
WARNING: Always test output voltage before
connecting devices to the power supply.
5. Connect cameras and other devices to the power
outputs, while observing correct polarity as shown in
Fig. 3. To minimize voltage drop, use 18-guage or
larger wire.
6. If voltage drop is large, adjust the output voltage
trimpot as shown in Fig. 4.
NOTE: The output voltage trimpot changes voltage for
all outputs by ±10%. Test all outputs to ensure
voltage does not exceed device specifications.
Location Color ON OFF
Cover
Green
Connected to AC power No AC input
Red
DC Output to PDM OK No DC output
Power distribution
module
Red
Terminal pair of output is
working correctly
Terminal pair of output has no
DC power

ENFORCER 12VDC Switching CCTV Power Supply
4 SECO-LARM U.S.A., Inc.
LARM policy is one of continual development and improvement. For that reason, SECO
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All t
are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2018 SECO-LARM U.S.A.,
LARM product is warranted against defects in material and workmanship while
service for two (2) years from the date of sale to the original customer. SECO-
LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship.
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM
option. In no event shall SECO-
LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
Users and installers of this product are responsible for ensuring this product complies
state, and local laws and statutes. SECO-LARM
will not be held responsible for the use of this product in violation of any
current laws or statutes.
Also Available from
®
:
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
MI_PC-Uxxxx-PULQ_180823.docx
Supplies
12VDC AC Adapters
Power Converters
DC Connectors
ALWAYS TEST OUTPUT VOLTAGE BEFORE CONNECTING DEVICES.
• Indoor use only. Do not mount the unit where it may be exposed to weather or high humidity.
• For professional installation only.
• Installation must conform to all local laws and building codes.
For 220VAC input voltage,
locate the input voltage switch
on the bottom of the enclosure. Switch the input voltage
from 110V to 220V as shown in Fig. 5.
Fig. 5 - Input voltage switch