SECO-LARM E-931CS22RRCQ, ENFORCER nE-931CS22RRCQ Installation Manual

Page 1
E-931CS22RRCQ
Range: 22ft. (7m)
Retro-Reflective Photoelectric Sensor Entry Alert System
Sensor
Caution:
ENFORCER
INSTALLATION MANUAL
Features:
Retro-reflective photoelectric sensor.
••
Range: Up to 22 feet (7m).
Perfect for monitoring an entrance, or for counting foot traffic with optional counter.
Will make “ding-dong” sound or siren sound when the beam is interrupted.
Speaker volume can be adjusted or turned off.
When in siren mode, sounding time is adjustable from 3 to 30 seconds.
9VDC adapter included.
This sensor was not designed to prevent bodily injury or loss of life.
Use of this sensor in certain security applications may be regulated by local laws or codes. SECO-LARM is not responsible for compliance with such laws or codes.
All components plug into each other. No hard wiring required.
Optional counter available (E-931ACC-CQ).
Optional second speaker available (E-931ACC-SQ).
Includes the following: — Retro-reflective photoelectric sensor. — Reflector. — Speaker/electronic chime. — 9VDC adapter.
Included:
E-931ACC-R1Q
Reflector
E-931CS22SQ
Transmitter/Receiver
E-931ACC-SQ
Speaker/Electronic Chime
ENFORCER
ENFORCER
E-931ACC-BLS4Q
E-931ACC-BLR1Q
Adapter
Note: Model numbers that ends with "Q" represents RoHS compliant products.
Page 2
Wiring: (one speaker, no counter)
¤¤¤¤¤¤¤
¤¤¤¤¤¤¤
Reflector
Sensor
Adaptor
Input
Up to 22' (7m)
Speaker
ENFORCER
®
DC 9V
Connect an optional counter or second speaker
W
e
m
e
c
l
o
Other possible applications: Offices, stores, schools, warehouse, vehicle detection, etc.
Garage
door
¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤
¤¤¤¤¤
Sample Installations:
Main
entrance
door
Store front door
¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤
¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤¤
Optional Accessories:
E-931ACC-RC
Round Reflector 80 x 80 mm
E-931ACC-CQ
Digital Counter
E-931ACC-HRQ
Reflector Hood for
Round/Square Reflector
Wiring: (with optional counter and second speaker)
¤¤¤¤¤¤¤
¤¤¤¤¤¤¤
Reflector
Sensor
Adaptor
Input
Up to 22' (7m)
Speaker
ENFORCER
®
Counter (optional)
DC 9V
Speaker (optional)
ENFORCER
®
Input
Output
Output
NOTE: a) When adding a 2nd speaker. If the application distance between speakers exceed 33 ft. (10m),
then a 9VDC adaptor is required for the 2nd speaker.
b) When there are 2 devices added to the first speaker, such as a 2nd speaker & a counter.
Then a second 9VDC adaptor is required for the 2nd speaker even when the distance is within 33 ft. (10m)
c) Speaker and counter uses a standard 1/8" stereo jacks.
Page 3
Mounting the Reflector:
Installation and Adjustment:
Sample Fixed Mounting:
Mounting the Sensor:
Mounting the Speaker/Electronic Chime:
Sample Fixed Mounting:
Sample Bracket Mounting:
Adjusting the Speaker/Electronic Chime:
LED Functions:
RED LED - When ON, it indicates the sensor is
powered and aligned properly.
Installation:
1. Mount the reflector and sensor so they face each other at about 2' off the ground or knee high.
2. Connect the sensor to the speaker.
3. Connect power adaptor to the speaker.
For signalling in multiple rooms, add an optional second speaker (E-931ACC-SQ).
Connect an optional counter (E-931ACC-CQ) to the speaker output (if desired).
4. To find the correct alignment, slowly adjust the angles of the sensor and/or reflector up and down and right and left.
NOTE:Correct alignment is reached when red LED
turns ON.
Set Speaker Mode:
After the sensor and reflector have been properly installed, the next step is to set the speaker mode.
1.
Choose between "Chime" or "Alarm" sound or "OFF".
2. If "Alarm" was chosen: A. Set speaker to Alarm B. Adjust the alarm sounding time from 3 to 30
seconds.
C. Set speaker Volume.
3. If "Chime" was chosen: Set speaker to Chime
4. If "OFF" was chosen: A. Set speaker to OFF
B. The speaker will not sound when the beam is
broken.
Using the Optional Counter:
1. Automatically increases by "1" when sensor is triggered.
2. Manually add "1" by pressing "+".
3. Manually subtract "1" by pressing "-".
4. Reset counter by pressing "RESET."
Testing:
1. Power up the sensor and speaker. The red LED should be ON.
2. Pass object to be detected between the sensor and reflector. The red LED should turn OFF and the speaker (if connected) should sound.
Red LED
ENFORCER
®
Switch: Chime/
OFF/Alarm Timer: 3~30 Sec. Volume:0 ~ max.
Switch
Wall mount hole
Bracket mounting holes
Page 4
Specifications:
Troubleshooting:
Dimensions:
PITSW3
®
E-931CS22RRCQ
Retro-Reflective Photoelectric Entry Alert System
22' (7 m)
Sensor: 8-13 VDC, Chime: 8-13 VDC
100mA Max.
30mA
IR LED
Transistor ground 100mA max.
-40F (-200C) ~ 1220F (500C)
~1 sec. for Chime, 30 sec. for Alarm
Adjustable from 0 ~ max.
Adjustable 3~30sec. for alarm
Ground output (100mA)
Chime / Off /Alarm (Select by switch)
All Included
Model Number Type Sensing Range Voltage Supply Total Current Consumption Stand-by Current Light Source Control Output Ambient Temperature Speaker Response Time Speaker Volume Alarm Time Range External Chime Output Speaker Output Mounting Brackets
Red LED does not turn on.
1) Reflector and/or sensor is misaligned.
2) No power.
1) Adjust the reflector and/or sensor for proper alignment
2) Check power adapter and cable.
Sensor does not detect the object. Sensor not aligned properly.
Change the angle of the sensor or
reflector.
Trouble Remedy(s)Possible Origin(s)
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.,
16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999
Fax: 949-261-7326 Website: www.seco-larm.com E-mail: sales@seco-larm.com
WARRANTY:
ENFORCER Photobeam Sensors are warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original customer. Our obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation pre-paid, to SECO-LARM.