ENF ORCER
SENSOR
MANUAL
Multi-Frequency
Quad Photobeam Detectors
E-964-Q660Q–
E-964-Q495Q– 495 ft. (150m) outdoors, 990 ft. (300m) indoors
E-964-Q330Q– 330 ft. (100m) outdoors, 660 ft. (200m) indoors
E-964-Q165Q– 165 ft. ( 50m) outdoors, 330 ft. (100m) indoors
660 ft. (200m) outdoors, 1320 ft.
(400m) indoors
SECO-LARM
®

ENFORCER Quad-Photobeam Detectors
TABLE OF CONTENTS
Introduction .................................................. 2
Features ....................................................... 2
Overview ....................................................... 3
Wiring Diagram ............................................ 4
Choosing a Location .................................... 4
Running the Cable ...................................... 4
Multiple Sensor Sample Applications .......... 5
Typical Installations ..................................... 5
Wiring the Transmitter – Wall Mount ........... 6
Wiring the Transmitter – Pole Mount ........... 6
Wiring.......................................................... 6
Examples of Ways To Connect Sensors...... 7
Selectable 4-channel Beam Frequency...... 8
Receiver Detail............................................ 8
Beam Alignment T emplate .......................... 8
Beam Alignment ......................................... 9
Adjusting the Response Time ................... 10
T esting the Unit......................................... 10
Specifications ........................................... 1 0
Dimensions ............................................... 11
Troubleshooting ........................................ 11
Introduction:
The ENFORCER E-964-Q Series Quad-Photobeam Sensors are ideal for long-distance protection.
Four selectable beam frequencies allow for superior perimeter protection by eliminating crosstalk and
interference between multiple units. False alarms created by animals and falling leaves are
minimized by the sensor's detection method of all 4 beams simultaneously broken.
The E-964-Q Series of sensors is designed to work in even the most extreme conditions. A built-in
heater automatically turns on and off depending on the outside temperature. An environmental control
output senses a slow degradation in beam strength when weather conditions worsen preventing false
alarms.
Installation and alignment is quick and easy with the ENFORCER E-964-Q Series. The built-in laser
and visual alignment systems quickly and easily pinpoint the approximate mounting location for the
transmitter and aid in aligning the transmitter and receiver units once mounted. A beam strength
indicator clearly displays the strength of the beam at the receiver with 5 LEDs.
Features:
●
Four selectable beam frequencies to eliminate
interference between multiple units for
enhanced perimeter protection.
●
Audible beam alignment (buzzer).
●
Beam strength indicator (5 LEDs).
●
Environmental Output (Selectable N.O. or N.C.):
Signal is sent if a degradation in environmental
conditions is detected such as thickening fog to
prevent false alarms.
●
Built-in heater.
2
●
IP-55 ingress protection.
●
Lensed optics reinforce beam strength and
provide excellent immunity to false alarms due
to rain, snow, mist etc.
●
Automatic input power filtering with special
noise rejection circuitry.
●
Voltage testing points for fine tuning the beam
alignment.
●
Input voltage: 12-24V AC/DC.
●
Response time adjustable for nearly all
situations.
SECO-LARM® U.S.A.

Fig. 1: Overview
ENFORCER Quad-Photobeam Detectors
Alignment laser
Vertical
adjustment screw
Green power LED
Power 12~24V AC/DC
Alarm output
Beam strength
indicator (5 LEDs)
Tamper output
On/Off switch for laser
Viewfinder
Horizontal
adjustment grip
Red signal LED
NC/NO switch
On/Off
Beam channel selection DIP
switches
Response time (50ms~700ms)*
Environmental
output
}
Voltage output probes
Vertical
adjustment screw
Alignment laser
Heater power
Environmental output
Horizontal
adjustment grip
(Receiver shown)
On/Off switch for laser
IMPORTANT – Do not connect to power until the sensor is completely installed and the
installation has been double-checked.
* Factory default 50ms
SECO-LARM® U.S.A.
Viewfinder for alignment
3

ENFORCER Quad-Photobeam Detectors
Fig. 2: Wiring Diagram
Receiver
Power AC/DC
12-24V
(non-polarity)
Alarm O/P
1A @
125VAC
/24VDC
T amper output
N.C. switch
1A @ 30VDC
(Max.)
N.C.
Com
N.O.
1
2
3
4
Heater
5
6
7
Environmental
output (NO/
NC)
1A @ 125 VAC
/24VDC
Transmitter
Power AC/DC
12-24V
(non-polarity)
T amper output
N.C. switch
1A @ 30VDC
(Max.)
1
2
Heater
6
7
Choosing a Location
1. Find a suitable location for the receiver within wiring distance of a power supply and the alarm panel.
2. Establish a clear line-of-sight area between the receiver location and the transmitter location.
3. Make sure no trees or vegetation will cause false alarms during windy conditions.
4. Find locations away from standing water that could be splashed on to the receiver or the transmitter.
5. Do not mount the receiver where sunlight or bright lights shine directly into the unit.
6. Install at a distance of 32" to 39" (80 to 100 cm) above the ground for most situations. See fig. 3.
Running the Cable
Run a cable from the alarm control panel to the photobeam sensor. If burying the cable is required, make
sure to use electrical conduit. Shielded cable is strongly suggested. See Table 1 for maximum cable length.
Table 1: Cable Length
Model E-964-Q660Q
Wire Size
AWG22
AWG20
AWG18
AWG17
Note (1): Max. cable length when two or more sets are connected is the value shown in Table 1 divided by the no. of sets.
E-964-Q165Q E-964-Q330Q
12V 24V 12V 24V 12V 24V
320m
1,050ft.
550m
1,800ft.
800m
2,600ft.
980m
3,190ft.
2,800m
18,000ft.
4,800m
15,750ft.
7,200m
23,620ft.
8,800m
28,870ft.
280m
920ft.
450m
1,480ft.
700m
2,300ft.
850m
2,790ft.
2,400m
7,870ft.
4,200m
13,780ft.
6,200m
20,340ft.
7,600m
24,930ft.
4
E-964-Q495Q
200m
660ft.
350m
1,150ft.
500m
1,640ft.
590m
1,940ft.
12V 24V
1,600m
5,250ft.
3,000m
9,840ft.
4,200m
13,780ft.
5,200m
17,060ft.
110m
390ft.
170m
560ft.
250m
820ft.
310m
1,020ft.
SECO-LARM® U.S.A.
900m
2,950ft.
1,400m
4,590ft.
2,200m
7,220ft.
2,600m
8,530ft.