SECO-LARM ENFORCER E-931-S33PRGQ User Manual

Page 1
E-931-S33PRGQ
33ft Polarized Reflective Photoelectric
Beam Sensor
Manual
Polarized sensor is immune to shiny objects: Triggers only when correctly reflected light is detected Weatherproof (IP55) Anti-condensation housing
12-30V DC/AC 60Hz, 100mA
Up to 33ft (10m) sensing range Round reflector, Ø 3
1
/4" (82mm)
Form C relay: 0.5A@30VAC/VDC Beam status LED N.C. Tamper switch:
500mA@30VAC/VDC
Caution:
This sensor is not designed to prevent bodily injury or loss of life. This sensor is not designed for use in environments where explosive gasses may be present. Use of this sensor in certain security applications may be regulated by local laws or codes. SECO-LARM is not
responsible for compliance with such laws or codes.
Conforms to UL 325
Page 2
ENFORCER 33ft Polarized Reflective Photoelectric Beam Sensor
2 SECO-LARM U.S.A., Inc.
Specifications:
Type
Polarized reflective
photoelectric beam sensor
Sensing range
33ft (10m)
Operating voltage
12-30V DC/AC 60Hz, 100mA
Current draw Standby
55mA@12VDC
Active
40mA@12VDC
Response time
10ms (max.)
Light source
IR LED/Wavelength 740nm
LED Solid green
Good beam signal, properly aligned
Alternating flash
Poor beam signal
Solid red
No beam signal, triggered
Trigger output
SPDT Relay output (NO/NC/COM)
Switching capacity
0.5A@30VAC/VDC
Tamper switch
N.C., 500mA@30VAC/VDC
IP Rating
IP55
Operating temperature
-4~131 F (-20~55 C)
Parts List:
1x Sensor 1x Reflector 1x Mounting bracket 1x Sensor hood 1x Reflector hood 4x Cover screws 2x Mounting screws 1x Reflector mounting screw 1x Rubber ring 1x Cable connector 1x Manual 1x Removable terminal block 1x 10kΩ Resistor
Note: Depending on the monitoring system used by the gate motor, it may be necessary to use either the N.C. output or
connect the included 10 resistor to the N.O. or N.C. output. Please refer to the gate operator manual or the gate operator manufacturer for the preferred monitoring method.
12-30V DC/AC
60Hz, 100mA (Non-Polarity)
Polarity does not matter for the power input. Connect the N.C. tamper terminal to the
tamper circuit of an alarm control panel.
Wiring Diagram:
N.C.
N.O.
COM
Tamper
N.C.
Relay
Dimensions:
Overview:
Tamper switch
Vertical adjustment screw
(without cover)
Cover
Cover screw
Wire cable connector
Mounting plate Hood
Beam
sensor LED
Terminal
block
Cable breakout
Captive screw Beam sensor
Cable breakout
25/16"
(59mm)
Ø 4"
(102mm)
3
/8"
(9mm)
413/16"
(122mm)
Ø 3/16"
(4mm)
21/8"
(54mm)
23/8"
(60mm)
115/16"
(49mm)
27/16"
(62mm)
Ø 31/4"
(82mm)
Page 3
ENFORCER 33ft Polarized Reflective Photoelectric Beam Sensor
SECO-LARM U.S.A., Inc. 3
Mounting:
Alignment:
Solid green
Good beam signal,
properly aligned
Alternating flash
Poor beam signal
Solid red
No beam signal,
triggered
Wiring for the Bottom Cable Breakout
1. Unscrew the four cover screws and remove the
cover.
2. Loosen the captive screw and remove the sensor
from the mounting plate.
3. Using the included mounting screws, mount the
mounting plate to the wall.
4. Use the cable breakout and cable connector at
the bottom or rear of the sensor to run the wires.
5. Hang the sensor back on the plate and use the
captive screw to secure it in place.
6. Re-attach the cover, replace the four screws, and
attach the hood to the top of the sensor.
1. Puncture the cable breakout located at the bottom
of the sensor using a screwdriver or other object.
2. Insert the short end side of the cable connector
into the cable breakout hole and use the nut to secure it, tightening with a wrench as needed.
3. Run the wires through the end cap and cable
connector.
4. Then screw the end cap into the external side of
the cable connector to prevent water from entering the unit.
1. Mount the sensor and reflector so that they face
each other.
2. Connect power to the sensor. The LED will light
as indicated in the chart below.
3. Unscrew the four cover screws and remove the
cover.
4. To find the correct alignment, slowly turn the
lens assembly left and right to adjust the horizontal angle.
5. Loosen the vertical adjustment screw to adjust
the vertical angle.
6. Place the hood on the sensor by sliding the
hood’s ridges into the slots on the sides of the sensor.
7. Re-attach the cover, replace the four screws,
and attach the hood to the top of the sensor.
Lens
alignment
±90
±5
Horizontal
adjustment
Vertical
adjustment
Cable Connector
End cap
Sensor
Nut
Rubber
neck
Page 4
ENFORCER 33ft Polarized Reflective Photoelectric Beam Sensor
4 SECO-LARM U.S.A., Inc.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2018 SECO-LARM U.S.A., Inc. All rights reserved.
MI_E-931-S33PRGQ_180124.docx
PITSW3
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Tel: 800-662-0800 / 949-261-2999 E-mail: info@seco-larm.com
Troubleshooting:
Sensor does not detect the object
Change the angle of the sensor or readjust
the sensitivity setting
The beam sensor LED will not turn green
Clean the sensor and reflector with a damp
(not wet) cloth
Adjust the reflector and/or sensor for
proper alignment
Beam sensor LED lights when object is detected, but there is no output
Check wiring between the sensor and local
alarm device
Sample Applications:
Other Sensors Available:
Dual and Quad
Beam
Curtain and
Barrier
Reflective
Photobeam
Parking
Distance Monitor
Gate
Garage
Door
Store
Entrance
E-931-S50RRGQ
50ft Reflective Photobeam
Loading...