Seco-Larm E-964-Q660Q, E-964-Q495Q, E-964-Q330Q, E-964-Q165Q User Manual

ENFORCER Quad-Photobeam Detectors
Also available from SECO-LARM:
E-960-D290Q
Twin Photobeam
Detectors
Range: up to 290' outdoors.
• Lensed optics reinforce beam
• strength and provide excellent immunity to false alarms due to rain, snow, mist, etc.
Weatherproof, sunlight filtering
• case for indoor and outdoor conditions.
Quick easy installation with built-
• in laser-beam alignment system.
E-932-D33TBQ
E-932-S16RRQ
Flush-Mount Photobeam
Sensors
E-932-D33TBQ – Photoelectric
• Through-Beam Sensor.
E-932-S16RRQ – Photoelectric
• Reflective-Beam Sensor.
Suitable for entrances, hallways,
• room in office or home.
Fits single-gang box.
• Adjustable alignment angle from
o
horizonatally / vertically.
+/-15
E-9622-4B25
Curtain / Barrier Sensors
Available in 4, 6, 8 or 10 beams.
• Range:25 ft. outdoor ,
50 ft. indoor. Slim-line design 7/8" x 15/16”. Weatherproof IP65 construction. Triggers on breaking of any
single or 2 adjacent beams (programmable).
®
ENF ORCER
SENSOR
MANUAL
Multi-Frequency
Quad Photobeam Detectors
E-964-Q660Q – E-964-Q495Q – 495 ft. (150m) outdoors, 990 ft. (300m) indoors E-964-Q330Q – 330 ft. (100m) outdoors, 660 ft. (200m) indoors E-964-Q165Q – 165 ft. ( 50m) outdoors, 330 ft. (100m) indoors
660 ft. (200m) outdoors, 1320 ft.
(400m) indoors
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of three (3) years from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE:
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM's ENFORCER Twin Photobeam detector series are protected by the following patents: U.S. pat. no. D485774 ; Taiwan pat. no. 89463 ; China pat. no. ZL0331103.0 Other international patents are pending.
SECO-LARMSECO-LARM
SECO-LARM
SECO-LARMSECO-LARM
16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
12
The information and specifications printed in this manual are current at the time of publication. However,
®
U.S.A., Inc. U.S.A., Inc.
U.S.A., Inc.
U.S.A., Inc. U.S.A., Inc.
Website: www.seco-larm.com E-mail: sales
MIE964-D_US_P0804u.pmd
@
seco-larm.com
PITSW3
SECO-LARM
Note: Products with model number that ends with "Q" or have a green “Q” sticker represents RoHS compliant products.
ENFORCER Quad-Photobeam DetectorsENFORCER Quad-Photobeam Detectors
T ABLE OF CONTENTS
Introduction................................................... 2
Features ....................................................... 2
Overview....................................................... 3
Wiring Diagram............................................. 4
Choosing a Location..................................... 4
Running the Cable ..................................... 4
Multiple Sensor Sample Applications........... 5
Typical Installations..................................... 5
Wiring the Transmitter – Wall Mount.......... 6
Wiring the Transmitter – Pole Mount ......... 6
Wiring ......................................................... 6
Examples of Ways To Connect Sensors ... 7
Selectable 4-channel Beam Frequency .... 8
Receiver Detail........................................... 8
Beam Alignment Template ......................... 8
Beam Alignment ........................................ 9
Adjusting the Delay Time ......................... 1 0
Testing the Unit ........................................ 10
Specifications ........................................... 10
Dimensions............................................... 11
Troubleshooting ....................................... 11
Introduction:
The ENFORCER E-964-Q Series Quad-Photobeam Sensors are ideal for long-distance protection. Four selectable beam frequencies allow for superior perimeter protection by eliminating crosstalk and interference between multiple units. False alarms created by animals and falling leaves are minimized by the sensor's detection method of all 4 beams simultaneously broken.
The E-964-Q Series of sensors is designed to work in even the most extreme conditions. A built-in heater automatically turns on and off depending on the outside temperature. An environmental control output senses a slow degradation in beam strength when weather conditions worsen preventing false alarms.
Installation and alignment is quick and easy with the ENFORCER E-964-Q Series. The built-in laser and visual alignment systems quickly and easily pinpoint the approximate mounting location for the transmitter and aid in aligning the transmitter and receiver units once mounted. A beam strength indicator clearly displays the strength of the beam at the receiver with 5 LEDs.
Features:
O
Four selectable beam frequencies to eliminate interference between multiple units for enhanced perimeter protection.
O
Audible beam alignment (buzzer).
O
Beam strength indicator (5 LEDs).
O
Environmental Output (Selectable N.O. or N.C.): Signal is sent if a degradation in environmental conditions is detected such as thickening fog to prevent false alarms.
O
Built-in heater.
O
IP-55 ingress protection.
O
Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist etc.
O
Automatic input power filtering with special noise rejection circuitry.
O
Voltage testing points for fine tuning the beam alignment.
O
Input voltage: 12-24V AC/DC.
O
Delay time adjustable for nearly all situations.
Fig. 15: Dimensions
411/32”
(110mm)
Upper
View
47/16”
43ST Pole Size
(113mm)
” (367mm)
4
/
1
15
Side View
Front View
Rear View
Troubleshooting:
Transmitter LED not lit
_________________________________________________________________________________________________________________________________
Receiver LED does not light when interrupted
_________________________________________________________________________________________________________________________________
Beams are interrupted and LED lights, but the alarm does not trigger.
_________________________________________________________________________________________________________________________________
Signal LED continuously lit
_________________________________________________________________________________________________________________________________
Alarm trigger becomes erratic in bad weather
_________________________________________________________________________________________________________________________________
Frequent false alarm triggers
Make sure the input power to the transmitter is 12 to 24 VAC/VDC.
Check the input power to the receiver is 12 to 24 VAC/VDC.
Check the continuity of the wiring from the receiver to the alarm.
Clear any obstacles between the transmitter and receiver. Clean the lenses of both units.
Check overall system installation. Realign the lenses.
Adjust the response time. Change location of transmitter and receiver.
2
SECO-LARM® U.S.A. SECO-LARM® U.S.A.
11
Loading...
+ 4 hidden pages