ENFORCER Curtain Sensors
1
7
/
32
” (30.6mm)
1
5
/
16
” (33.5mm)
Features ....................................................... 2
Parts List ....................................................... 2
Dimensions ................................................... 2
Specifications ............................................... 2
Sample Installations ..................................... 3
Choosing a Location ................................. 3~4
Selectable 3-Channel Beam Frequency ....... 4
Mounting the Curtain Sensor .................... 4~5
1x Transmitter
1x Receiver
4x L-Brackets
1x Manual
Mounting hardware
Running the Wires ........................................ 5
Connecting the Wires ................................ 5~6
Removing the Lens Caps .............................. 6
Connecting One or More Sensors ................ 7
Mounting the Transmitter and Receiver and
Testing the Sensor .................................... 7
Tamper Protection ........................................ 8
Troubleshooting ............................................ 8
11.25” (29cm) – E-9611-2x25
22.5” (57cm) – E-9622-4x25
44.5” (113cm) – E-9644-6x25
60.1” (153cm) – E-9660-8B25
79” (201cm) – E-9680-10B25
Multi-frequency to reduce interference
between multiple units
Install on windows, doorways, skylights,
fence tops, and any place where space is
limited
Perfect for indoor and outdoor perimeter
security
Slimline design – 1
5
/16”x7/8” (33x22 mm)
Rugged aluminum construction
NO/NC Relay output
2, 4, 6, 8, or 10 separate photoelectric beam
sensors; programmable trigger upon
breaking of any single beam or simultaneous
breaking of any two adjacent beams
Anti-tamper circuit for use when power is cut
or end cap is removed
No synchronizing wires required
LED alignment indicator
L-brackets and mounting hardware included
111/4”x15/16”x7/8”
(286x33x22 mm)
221/2”x15/16”x7/8”
(572x33x22 mm)
441/2”x15/16”x7/8”
(1130x33x22 mm)
601/8”x15/16”x7/8”
(1527x33x22 mm)
79”x15/16”x7/8”
(2007x33x22 mm)
Indoor: 50’ (16m), outdoor: 25’ (8m)
Simultaneous break of 2 adjacent beams or any single beam (programmable)
NO/NC Relay output, 1A@12~24 VDC
ON: Powered, aligned properly; Flashing: Beam broken or unaligned; OFF: No power
2 SECO-LARM U.S.A., Inc.
ENFORCER Curtain Sensors
When used outdoors, place the curtain sensor under a roof or shelter. This will reduce the
chance of false alarms caused by rain or snow.
To prevent erratic operation and/or false alarms:
Wind will not directly cause false alarms, but
could cause leaves or similar objects to fly
into or otherwise obstruct the beams. Do
not mount near trees, bushes, or other leafy
vegetation (see Fig. 1).
Do not mount where water running off the
roof might break the beam (see Fig. 1). The
sensor and beams must be sheltered.
Do not mount near reflective surfaces, as this
could prevent the sensor from working
properly.
Typical Door/Window
Frame
Fig. 1: Beware Natural Interference
Tree or shrub leaves
Rain running directly
off roof thru beams
Do not connect to power until the sensor is completely installed and the installation has been
double-checked.
SECO-LARM U.S.A., Inc. 3