Seco-Larm E-9644-6W25 User Manual

Curtain Sensors
Manual
Number of Beams
Length
Color
E-9680-10B25
10
80”
Black
E-9660-8B25 8 60”
Black
E-9644-6B25 6 44”
Black
E-9644-6W25 6 44”
White
E-9622-4B25 4 22”
Black
E-9622-4W25 4 22”
White
E-9611-2B25 2 11”
Black
E-9611-2W25 2 11”
White
ENFORCER Curtain Sensors
1
7
/
32
” (30.6mm)
1
5
/
16
” (33.5mm)
Table of Contents:
Features ....................................................... 2
Parts List ....................................................... 2
Dimensions ................................................... 2
Specifications ............................................... 2
Sample Installations ..................................... 3
Choosing a Location ................................. 3~4
Selectable 3-Channel Beam Frequency ....... 4
Mounting the Curtain Sensor .................... 4~5
Parts List:
1x Transmitter 1x Receiver 4x L-Brackets 1x Manual Mounting hardware
Running the Wires ........................................ 5
Connecting the Wires ................................ 5~6
Removing the Lens Caps .............................. 6
Connecting One or More Sensors ................ 7
Mounting the Transmitter and Receiver and
Testing the Sensor .................................... 7
Tamper Protection ........................................ 8
Troubleshooting ............................................ 8
Specifications:
Dimensions:
11.25” (29cm) – E-9611-2x25
22.5” (57cm) – E-9622-4x25
44.5” (113cm) E-9644-6x25
60.1” (153cm) – E-9660-8B25 79” (201cm) – E-9680-10B25
Top View
Side View
Features:
Multi-frequency to reduce interference
between multiple units
Install on windows, doorways, skylights,
fence tops, and any place where space is limited
Perfect for indoor and outdoor perimeter
security
Slimline design – 1
5
/16”x7/8” (33x22 mm)
Rugged aluminum construction NO/NC Relay output
2, 4, 6, 8, or 10 separate photoelectric beam
sensors; programmable trigger upon breaking of any single beam or simultaneous breaking of any two adjacent beams
Anti-tamper circuit for use when power is cut
or end cap is removed
No synchronizing wires required LED alignment indicator L-brackets and mounting hardware included
Model
E-9611-2x25
E-9622-4x25
E-9644-6x25
E-9660-8B25
E-9680-10B25
Standby@12~24 VDC
80mA
89mA
94mA
102mA
110mA
Active@12~24 VDC
60mA
73mA
79mA
92mA
100mA
Dimensions
111/4”x15/16”x7/8”
(286x33x22 mm)
221/2”x15/16”x7/8”
(572x33x22 mm)
441/2”x15/16”x7/8”
(1130x33x22 mm)
601/8”x15/16”x7/8”
(1527x33x22 mm)
79”x15/16”x7/8”
(2007x33x22 mm)
Response time
0.5~20 ms
0.5~32.5 ms
0.5~48.5 ms
0.5~60 ms
0.5~70 ms
Maximum range
Indoor: 50’ (16m), outdoor: 25’ (8m)
Detection method
Simultaneous break of 2 adjacent beams or any single beam (programmable)
Output
NO/NC Relay output, 1A@12~24 VDC
Operating temperature
-49°~131° F (-45°~55° C)
Attenuation LED
ON: Powered, aligned properly; Flashing: Beam broken or unaligned; OFF: No power
Enclosure / Case
IP65 / Aluminum alloy
3
/4” (19.6mm)
7
/8” (22.3mm)
2 SECO-LARM U.S.A., Inc.
ENFORCER Curtain Sensors
When used outdoors, place the curtain sensor under a roof or shelter. This will reduce the chance of false alarms caused by rain or snow.
To prevent erratic operation and/or false alarms:
Wind will not directly cause false alarms, but
could cause leaves or similar objects to fly into or otherwise obstruct the beams. Do not mount near trees, bushes, or other leafy vegetation (see Fig. 1).
Do not mount where water running off the
roof might break the beam (see Fig. 1). The sensor and beams must be sheltered.
Do not mount near reflective surfaces, as this
could prevent the sensor from working properly.
Typical Door/Window
Frame
Windows
Indoor Fence Tops
Garages/Gates/Walls
Skylights
Fig. 1: Beware Natural Interference
Tree or shrub leaves
Rain running directly
off roof thru beams
Important:
Do not connect to power until the sensor is completely installed and the installation has been double-checked.
Sample Installations:
Choosing a Location:
SECO-LARM U.S.A., Inc. 3
ENFORCER Curtain Sensors
Do not mount where the transmitter or
receiver could be splashed by water or mud.
Do not mount where unit could be
suddenly exposed to a bright light,
such as a floodlight or a passing car’s
headlight.
Do not let sunlight or any direct beam of
light shine directly on the curtain beam sensor. If unavoidable, mount so the transmitter, not the receiver, faces the sun (see Fig. 2).
Do not mount where animals or other objects could accidentally break the beams.
Choosing a Location, continued:
Fig. 2: Orientation to Sun
The sensor beam frequency can be set at different frequencies on-site to avoid interference from multiple curtain sensors nearby. To select between three different beam frequencies, set the jumper of the transmitter side and receiver side (see Fig. 3).
Note:
1. If the frequency is changed, power must be cycled on the transmitter and receiver
after the new frequency is selected.
2. Both the transmitter and the receiver of each pair must be set to matching
frequencies to work together correctly.
1. Find a suitable location (see Fig. 1):
a. The transmitter and receiver can be
mounted at any angle as long as they are parallel to each other and directly facing each other, and as long as the wires come out of the same ends of both units (see Fig. 4).
b. If using multiple curtain sensors, be sure
to set each for a different frequency (see Selectable 3-Channel Beam Frequency above).
c. The transmitter and receiver must not be
separated by more than 50 feet indoors and 25 feet outdoors.
TX
RX
RX
TX
NO
OK*
*Only if unavoidable. Mount so transmitter, not receiver, faces the sun.
Selectable 3-Channel Beam Frequency:
Mounting the Curtain Sensor:
Frequency A
Frequency B
Frequency C
Fig. 3: Jumper Position
JMP3
{
Fig. 4: Orientation
Note: If the wires will be running out the end, place sensors so wires are at the bottom. If sensors must be placed so wires are at top, seal the opening with silicone to prevent water from leaking in.
OK
NO
Terminal
blocks
Terminal
block
Terminal
block
4 SECO-LARM U.S.A., Inc.
ENFORCER Curtain Sensors
Run four wires (2x power and 2x alarm signal) from the alarm control panel to the receiver of the curtain sensor. Shielded cable is strongly suggested. See Table 1 to the right for maximum wire length. Two power wires must also be run to the transmitter.
It may be more convenient to connect the transmitter’s two power wires to the receiver’s power
wires. In this case, run six wires to the receiver: two wires to the power source, two for the alarm signal, and two to the transmitter.
Note:
1. If burying the wires is required, make sure to run them through electrical conduit.
Shielded cable is strongly suggested.
2. If the wires are run along the wall, using an armored cable is strongly suggested.
2. Mount the transmitter and the receiver so that the
surface-mounted wires do not come out from above the units. This is to prevent water from entering via the wire holes. If this is unavoidable, use silicone to completely cover the area where the wires come out the holes to prevent water from entering (see Fig. 4).
3. Once a suitable mounting location has been found,
remove the covers of the end caps (see Fig. 5), and pull the tamper buttons out of the end caps (one per transmitter or receiver) and locate the mounting holes. Using these holes as a template, mark their location on the wall with a pencil.
4. Connect the wires (see Figs. 6 and 7) before permanently mounting the units to the wall.
Fig. 5: End Cap Cover
Plastic cap
hiding screw
Screw
Tamper Button
1. Receiver:
a. Pull the end cap with the red wire leads off the
receiver, and slide the PCB out far enough to expose the wiring block.
b. Run the four wires (or six wires, if connecting
the transmitter’s power wires to the receiver) through one or more of the three ground knockout holes in the end cap near where the tamper button wires run, and connect them to the wiring block (see Fig. 6).
c. Program the receiver (see Table 2 on pg. 6). d. Carefully push the PCB back into the case
and reinsert the end cap.
e. Reinsert the cap over the tamper button and small tamper cap.
To Alarm Control Panel 12~24 VDC
Fig. 7: Wiring the Transmitter
Running the Wires:
Table 1: Maximum Wire Length
Voltage
Gauge
Max. length
12VDC
AWG 22
1800’ (550m)
12VDC
AWG 20
2600’ (800m)
24VDC
AWG 22
2600’ (800m)
24VDC
AWG 20
3900’ (1200m)
Mounting the Curtain Sensor, continued:
Connecting the Wires:
Fig. 6: Wiring the Receiver
To Alarm Control Panel 12~24 VDC
To Alarm Control Panel COM + N.O. or COM + N.C.
}
COM
N.C.
N.O.
SECO-LARM U.S.A., Inc. 5
ENFORCER Curtain Sensors
For best results when the curtain sensor is mounted outdoors, remove the transmitter lens caps (DO NOT remove the receiver lens caps!).
To remove the lens caps (see Fig. 8):
1. Slide the PCB out of the transmitter (see
“Connecting the Wires” on pg. 5~6).
2. Carefully pull the lens cap off of all the lenses
(4 for the E-9611-2x25, 8 for the E-9622-4x25, 12 for the E-9644-6x25, 16 for the E-9660-8B25, 20 for the E-9680-10B25).
3. Slide the PCB back in (see “Connecting the Wires” on pg. 5~6).
2. Transmitter:
a. Pull the end cap with the red wire leads off the transmitter, and slide the PCB out far
enough to expose the wiring block.
b. Run the two power wires through one or more of the three round knockout holes in the end
cap near where the tamper button wires run; connect them to the wiring block (see Fig. 7).
c. Program the transmitter (see Table 2 below). d. Carefully push the PCB back into the case and reinsert the end cap. e. Reinsert the cap over the tamper button and small tamper cap.
Note:
1. Screw the wires tightly to avoid slipping off the terminals, but not so tight that they break.
2. Unused terminal screws should be tightened.
3. Grounding may be necessary, depending on the location.
Fig. 8: Removing the Lens Caps
Connecting the Wires, continued:
*Both JMP2 and SA1 should be taken off or left on at the same time.
Removing the Lens Caps (for outdoor use only):
Table 2: Transmitter and Receiver Programming
Receiver
Transmitter
Jumper name
JMP1
JMP0
LED Operation
1 C 2
LED ON if power is present and beams are aligned.
LED flashes when
beams are broken.
1 C 2
LED OFF if power is
present and beams
are aligned.
LED flashes when
beams are broken.
LED ON
LED ON if power
is present.
LED OFF
LED OFF at
all times.
Jumper name
JMP2
SA1
Number of beams to interrupt to trigger transmitter
and receiver
1 Beam
Receiver triggers if any single beam is
interrupted.*
2 Beams
Receiver triggers only if 2 adjacent beams interrupted
at same time.*
1 Beam
Transmitter triggers if any single beam is
interrupted.*
2 Beams
Transmitter triggers only if 2 adjacent beams interrupted at
same time.*
6 SECO-LARM U.S.A., Inc.
ENFORCER Curtain Sensors
Several units can be connected together in parallel to the same power supply output and alarm input of an alarm control panel.
Please reference Fig. 6 & 7 for terminal blocks.
1. Temporarily mount the transmitter and receiver to where they are expected to be mounted, so
the mounting position can be changed if necessary.
2. Connect the transmitter and the receiver.
3. Once it is powered up, test the curtain sensor by breaking two adjacent beams or any single
beam (depending on programming).
4. The curtain sensor also has red LEDs which can be used for testing purposes (see Table 2).
5. After the curtain sensor is tested and aligned, permanently mount it.
6. After it is mounted, test the curtain sensor again.
Connecting One or More Sensors:
Mounting the Transmitter and Receiver and Testing the Sensor:
Standard
} Power
} Alarm signal
Control panel
(12VDC)
Dual Sensors, Separate Alarm Channels
Transmitter
Receiver
Receiver
Transmitter
} Power
} Alarm (ch. 1)
Control panel
(12VDC)
} Alarm (ch. 2)
In-line, Single Alarm Channel
} Power
} Alarm signal
Control panel
(12VDC)
Transmitter
Receiver
Receiver
Transmitter
Transmitter
Receiver
SECO-LARM U.S.A., Inc. 7
ENFORCER Curtain Sensors
The receiver and the transmitter both have a tamper switch on one end to protect against someone attempting to open the unit. However, there is no separate tamper output to the alarm control panel. Instead, the alarm output is triggered if the cover of the end cap with the tamper button is removed, if the transmitter or receiver is moved out of alignment, or if power is disconnected.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
LIMITED WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
PICTN1
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
MiE-96xx-xxB25_141008.docx
Tamper Protection:
Troubleshooting:
Transmitter LED will not turn ON
Test the power and ground wire with a voltage meter to
ensure power is connected and is of the correct voltage.
Change the position of the transmitter jumper “JMP0”
(see page 6).
Receiver LED will not turn ON
Test the power and ground wire with a voltage meter to
ensure power is connected and is of the correct voltage.
Receiver LED will not turn ON unless the sensor is triggered
Change the position of the receiver jumper “JMP1”
(see page 6).
Receiver LED flashes continuously
Check that the transmitter and receiver are aligned.
Does not trigger when beam is broken
Remount the curtain sensor away from any shiny surface,
or repaint the surface to cut down on reflection.
Receiver continuously triggers the alarm
Check that the transmitter and receiver are aligned. Check that the tamper button and the cover for the
tamper button are mounted correctly.
False alarm
Re-install so that multiple sensors do not interfere with
each other.
Cut back leafy vegetation. Re-mount away from the edge of a roof. Mount under a roof or shelter.