Seco-Larm E-9644-6W25 User Manual

Curtain Sensors
Manual
Number of Beams
Length
Color
E-9680-10B25
10
80”
Black
E-9660-8B25 8 60”
Black
E-9644-6B25 6 44”
Black
E-9644-6W25 6 44”
White
E-9622-4B25 4 22”
Black
E-9622-4W25 4 22”
White
E-9611-2B25 2 11”
Black
E-9611-2W25 2 11”
White
ENFORCER Curtain Sensors
1
7
/
32
” (30.6mm)
1
5
/
16
” (33.5mm)
Table of Contents:
Features ....................................................... 2
Parts List ....................................................... 2
Dimensions ................................................... 2
Specifications ............................................... 2
Sample Installations ..................................... 3
Choosing a Location ................................. 3~4
Selectable 3-Channel Beam Frequency ....... 4
Mounting the Curtain Sensor .................... 4~5
Parts List:
1x Transmitter 1x Receiver 4x L-Brackets 1x Manual Mounting hardware
Running the Wires ........................................ 5
Connecting the Wires ................................ 5~6
Removing the Lens Caps .............................. 6
Connecting One or More Sensors ................ 7
Mounting the Transmitter and Receiver and
Testing the Sensor .................................... 7
Tamper Protection ........................................ 8
Troubleshooting ............................................ 8
Specifications:
Dimensions:
11.25” (29cm) – E-9611-2x25
22.5” (57cm) – E-9622-4x25
44.5” (113cm) E-9644-6x25
60.1” (153cm) – E-9660-8B25 79” (201cm) – E-9680-10B25
Top View
Side View
Features:
Multi-frequency to reduce interference
between multiple units
Install on windows, doorways, skylights,
fence tops, and any place where space is limited
Perfect for indoor and outdoor perimeter
security
Slimline design – 1
5
/16”x7/8” (33x22 mm)
Rugged aluminum construction NO/NC Relay output
2, 4, 6, 8, or 10 separate photoelectric beam
sensors; programmable trigger upon breaking of any single beam or simultaneous breaking of any two adjacent beams
Anti-tamper circuit for use when power is cut
or end cap is removed
No synchronizing wires required LED alignment indicator L-brackets and mounting hardware included
Model
E-9611-2x25
E-9622-4x25
E-9644-6x25
E-9660-8B25
E-9680-10B25
Standby@12~24 VDC
80mA
89mA
94mA
102mA
110mA
Active@12~24 VDC
60mA
73mA
79mA
92mA
100mA
Dimensions
111/4”x15/16”x7/8”
(286x33x22 mm)
221/2”x15/16”x7/8”
(572x33x22 mm)
441/2”x15/16”x7/8”
(1130x33x22 mm)
601/8”x15/16”x7/8”
(1527x33x22 mm)
79”x15/16”x7/8”
(2007x33x22 mm)
Response time
0.5~20 ms
0.5~32.5 ms
0.5~48.5 ms
0.5~60 ms
0.5~70 ms
Maximum range
Indoor: 50’ (16m), outdoor: 25’ (8m)
Detection method
Simultaneous break of 2 adjacent beams or any single beam (programmable)
Output
NO/NC Relay output, 1A@12~24 VDC
Operating temperature
-49°~131° F (-45°~55° C)
Attenuation LED
ON: Powered, aligned properly; Flashing: Beam broken or unaligned; OFF: No power
Enclosure / Case
IP65 / Aluminum alloy
3
/4” (19.6mm)
7
/8” (22.3mm)
2 SECO-LARM U.S.A., Inc.
ENFORCER Curtain Sensors
When used outdoors, place the curtain sensor under a roof or shelter. This will reduce the chance of false alarms caused by rain or snow.
To prevent erratic operation and/or false alarms:
Wind will not directly cause false alarms, but
could cause leaves or similar objects to fly into or otherwise obstruct the beams. Do not mount near trees, bushes, or other leafy vegetation (see Fig. 1).
Do not mount where water running off the
roof might break the beam (see Fig. 1). The sensor and beams must be sheltered.
Do not mount near reflective surfaces, as this
could prevent the sensor from working properly.
Typical Door/Window
Frame
Windows
Indoor Fence Tops
Garages/Gates/Walls
Skylights
Fig. 1: Beware Natural Interference
Tree or shrub leaves
Rain running directly
off roof thru beams
Important:
Do not connect to power until the sensor is completely installed and the installation has been double-checked.