Seco-Larm E-964-D390Q, E-960-D90Q, E-960-D190Q User Manual

Also Available from SECO-LARM:
Quad Photobeam
Detectors
• 4 Models available - up to 660 ft. (200m) range.
• Weatherproof
• 12~24 VAC/VDC
• Laser-beam alignment
Reective
Photobeam Sensor
Curtain Sensors
• 2, 4, 6, 8, or 10 Beams available
• Up to 50ft (15m) range
• Weatherproof
• Slimline design
• Laser-beam alignment
Hooded Reective
Photobeam Sensors
Long-Range
Barrier Sensors
Twin Photobeam Detectors
Manual
• 2, 4, 6, or 8 Beams available
• Up to 393ft (120m) range
• Weatherproof
• Multi-frequency
• Adjustable interruption time
Flush-Mount
Photobeam Sensors
• Available with 45ft (14m) or 35ft (11m) range
• Weatherproof
• Mounting hardware included
• Reflector included
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2013 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
• Available with 50ft (15m) range or 33ft (10m) range
• Weatherproof
• Polarized version available
• Round reflector included
12
• Available with reflective beam and 16ft (5m) range or through-beam and 33ft (10m) range
• Adjustable alignment angle
• Mounts to a single-gang box
file:DTP\Manual\MiE96x-DxxxQ_P1305.pmd
Website: www.seco-larm.com E-mail: sales
@
seco-larm.com
PITSW3
Model # Outdoor Range Indoor Range E-964-D390Q* 390 ft. (120m) 790 ft. (240m) E-960-D290Q 290 ft. (90m) 590 ft. (180m) E-960-D190Q 190 ft. (60m) 390 ft. (120m) E-960-D90Q 90 ft. (30m) 190 ft. (60m)
* Multi-frequency version
SECO-LARM
Note: Products with model numbers that end with "Q" or that have a round green"Q"sticker are RoHS compliant.
®
®
TABLE OF CONTENTS
Important ......................................................... 2
Choosing a Location........................................ 3
Typical Installations ....................................... 4
Running the Cable ........................................... 4
Wiring the Transmitter – Wall Mount ............... 4
Wiring the Transmitter – Pole Mount ................ 5
Wiring ............................................................. 5
Examples of Ways To Connect Sensors ............ 6
Selectable 4-channel Beam Frequency ............ 7
Beam Frequency Selection Chart ..................... 7
(E-964-D390Q Model Only)
Multiple Sensors Sample Applications
Adjusting the Alignment ................................. 9
Adjusting the Delay Time ............................... 10
Testing the Unit ............................................. 10
Specifications ............................................... 10
Dimensions ................................................... 11
Troubleshooting ............................................. 11
.......... 7-8
Fig. 12: Dimensions
Upper View
43ST Pole Size
2.8” (72mm)
2.9” (74mm)
6.8” (173mm)
Features:
l
Four selectable beam frequencies (For E-964-D390Q model only).
l
Twin beams provide reliable perimeter security,
minimizing false alarms from
falling leaves, birds, etc.
l
Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist, etc.
l
Weatherproof, sunlight-ltering case for indoor and outdoor use.
l
Non-polarized power inputs.
l
Automatically adjusts beam strength to compensate for different weather
conditions
l
Automatic input power ltering with special noise rejection circuitry.
l
N.C./N.O. alarm output.
l
N.C. tamper circuit included.
l
Quick, easy installation with built-in laser beam alignment system.
l
Interruption time adjustable for nearly all situations.
Included:
Transmitter x 1 Receiver x 1 Mounting plates x 2
Pole mounting
brackets (2 sets)
Mounting hardware
also includ-
ed.
Side View
Table 6: Troubleshooting
Situation
Transmitter LED does not light.
Receiver LED never lights up when the beam is interrupted.
Beams interrupted and LED lights, but no alarm trigger.
Alarm LED continuously lit.
Alarm trigger becomes erratic in bad weather.
Frequent false triggers from leaves, birds, etc.
Front View
Possible Problem
Incorrectly wired and/or insufcient voltage
a. Insufcient voltage b. Beam reected away from receiver c. Beams not simultaneously interrupted.
Alarm trigger cable may be cut, or the relay contact stuck due to overloading.
a. Lenses out of alignment. b. Beams are blocked. c. Cover is foggy or dirty.
Lenses out of alignment.
a. Too sensitive. b. Bad location.
Rear View
Solution
Ensure the power supply to the transmitter is 12 to 24 VAC/VDC.
a. Double-check the voltage. b. Clean the cover. c. Check overall installation.
Check the continuity of the wiring between the sensor and the alarm.
a. Realign the lenses. b. Remove any obstacles. c. Clean the cover.
Check overall system installation. If still erratic, realign the lenses.
a. Reduce the response time. b. Change the transmitter and/or location.
IMPORTANT
Do not connect to power until the sensor is completely installed and
the installation has been double-checked.
2
11
Loading...
+ 4 hidden pages