SECO-LARM E-942SA-1300, E-941SA-600, E-942SA-600, E-941SA-1200, E-941SA-300 Installation Manual

...
ELECTROMAGNETIC LOCK Installation ManualELECTROMAGNETIC LOCK Installation Manual
SECO-LARM U.S.A., Inc.
When power is applied to the electromagnetic lock, it turns on the unit's powerful built-in electromagnet. This electromagnet is attracted to the steel armature plate which is mounted on a door, holding the door fast against unauthorized entry. When power to the magnetic lock is turned off, the electromagnet releases the armature plate, allowing the door to open.
SPECIFICATIONS
12~24VDC 23/4 x 11/4 x 13/16 in. (70 x 31 x 20 mm) 23/8 x 11/4 x 23/64 in. (60 x 31 x 9 mm) 80 lb. (36kg.) @ 12VDC 110lb.(51Kg.) @ 24VDC 85mA @ 12VDC 165mA @ 24VDC ± 10% Aluminum 14°F to 131°F (-10°C to 55°C)
0.90 lb. (410 grams)
HOW THEY WORK
Installation Manual
E-941SA-80Q
Also available:
E-941SA-1200
1200-lb. electromagnetic lock
E-941SA-600
600-lb. electromagnetic lock
E-941SA-300
300-lb. electromagnetic lock
E-941SA-1K2PD
1200-lb. electromagnetic lock with status LED status sensor & delay timer
E-941DA-1K2P
Double-Door 1200-lb. electromagnetic lock with status LEDs & status sensors
E-942SA-1300
1300-lb. water-resistant gate lock
E-942SA-600
600-lb. water-resistant gate lock
Page 4
Power Magnet Size Armature Size Holding Force
Current Drain
Voltage T olerance Housing Temperature Weight
PITLW1
Filename: MIE941SA-80_056.PMD
REGULAR MAINTENANCE
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non­abrasive, non-corrosive cleaner.
• Apply a light coat of a silicon lubricant and wipe away the excess to prevent rust.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the door frame.
TROUBLESHOOTING
Problem:
Door does not lock
Door locks, but can be easily forced open
Delay in door releasing
Possible cause:
No power
Poor contact between electromagnet and armature plate
Insufficient voltage
A secondary diode was installed across the electromagnet
Solutions:
• Check to make sure the wires are connected properly.
• Check that the power supply is connected and operating
• Make sure the lock switch is wired correctly
• Make sure the electromagnet and armature plate are properly aligned
• Make sure the contact surfaces of the electromagnet and armature plate are clean and free from rust
• Check the power leads with a meter, and make sure power is supplied between 12~24VDC.
• The electromagnet is fitted with a metal oxide varistor to prevent interference, so do not install a secondary diode
NOTICE
The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2005 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com E-mail: sales
@
seco-larm.com
WARRANTY: ENFORCER Electromagnetic Locks are warranted against defects in
material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original customer. Our obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
SECO-LARM U.S.A., Inc.
E-941SA-80 Installation Manual
E-941SA-80
Installation Manual
Page 2 Page 3
A. Drill holes for the mounting plate and
armature plate (see fig. 1 and 2) by doing the following:
1. Fold the mounting template along the dotted line
2. Close the door. Find a mounting location on the door frame near the upper free-moving corner of the door, as close to the corner of the door frame as possible.
3. Place the template against the door and frame.
4. Drill two holes in the door frame for the mounting plate and three holes in the door as indicated on template.
5. Only from the sexnut bolt side of the door, enlarge the 5mm hole to 9mm.
B. Mount the armature plate to the door
using the two steel and one rubber washer (fig. 2):
NOTE — Actual installation varies according to door style.
1. Secure the two guidepins into the two side holes of the armature
plate.
2. Insert the armature screw into the armature plate, then put the rubber washer between two steel washers, and place them over the armature screw between the armature plate and the door. This will allow the armature plate to pivot slightly around the armature screw in order to compensate for door misalignment.
2. Insert the sexnut bolt into the 9mm hole, then tighten the sexnut bolt and the armature screw, just enough so the armature plate can withstand the force of someone attempting to break down
MOUNTING THE E-941SA-80Q
the door while the electromagnet is engaged.
3. Do not tighten the armature plate against the door. The plate must be able to pivot around the armature screw.
C. Screw the mounting plate to the door
frame:
1. Remove the L-shaped mounting
plate from the magnet.
2. Insert the provided two 1/8" x 1"
(4 x 25.4 mm) screws into the L-shaped mounting plate and screw it to the door frame. The armature plate and the mounting plate must be concentric or align with each other.
D. Drill the power cable access hole.
E. Mount the electromagnet to the door
frame (fig. 1) — Use the Allen wrench to screw the socket-head mounting screws through the bottom of the electromagnet into the mounting bracket.
F. Connect the power leads (fig. 3):
1. Run two power leads from the
power supply through the power cable access hole into the electromagnet.
2. Connect the power leads to the red
and black power input wires of the unit. Observe correct polarity, red for positive and black for negative.
G. Test the unit.
Sexnut bolt
This side drill 9mm only
Drill a 5mm hole thru door
Armature Screw
Steel and Rubber washers (as needed)
Armature
HOLLOW METAL DOOR
Drill an 5mm hole thru door. From sexnut bolt side only, enlarge the 5mm hole to 9mm.
Drill an 5mm hole thru door. From sexnut bolt side of door, drill 9mm (
23/64
") hole,
25mm in depth.
Drill a 3.5mm dia. hole and tap for M5 x 0.8 thread.
Sexnut bolt
Drill 9mm (23/64")
Drill a 5mm hole thru door
Armature Screw
Armature
SOLID CORE DOOR
Armature Screw
Tap M5 x 0.8 Thread
REINFORCED DOOR
Armature
FIG.1 Standard Mounting
FIG. 2 Types of armature plate mounting
FIG. 3 Wiring diagram
Steel and Rubber washers (as needed)
Steel and Rubber washers (as needed)
Power wires to electromagnet
Control Device
+
-
Red
Black
12~24VDC Power Supply
L-shaped Maounting bracket
Magnet
Sexnut bolt
Armature Plate Steel and Rubber washers
Loading...