Magnetic Gate Lock Installation Manual
Installation Manual
TROUBLESHOOTING
Problem:
Gate does not lock
Gate locks, but can be
easily forced open
Delay in gate releasing
Possible cause:
No power
Poor contact between
electromagnet and
armature plate
Incorrect voltage
setting
A secondary diode was
installed across the
electromagnet
Solutions:
• Check to make sure the wires are secure
• Check that the power supply is connected
and operating
• Make sure the unit is wired correctly
• Make sure the electromagnet and
armature plate are properly aligned
• Make sure the contact surfaces of the
electromagnet and armature plate are
clean and free from rust
• Check the power leads with a meter, and
make sure the correct voltage is present
• The electromagnet is fitted with a metal
oxide varistor to prevent interference, so
do not install a secondary diode
REGULAR MAINTENANCE
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-
corrosive cleaner.
• Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the gate or post.
UL CERTIFICATION
The E-942FC-1300 and E-942FC-600 electromagnetic locks conform to UL/10B “Fire Tests of Door Assemblies” and UL/10C “Positive
Pressure Fire Tests of Door Assemblies” for swinging door assemblies. They are also classified in accordance with the Uniform Building
Code standard 7-2.
LIFETIME LIMITED WARRANTY: This SECO-LARM product is warranted against defects in material
and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will
SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of
any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States and
Canada. For all other countries the warranty is 1 (one) year.
NOTICE
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM. This material is subject to change without notice. SECO-LARM is
not responsible for misprints.
O A
SECO-LARM
O ASECO-LARM
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 4
U.S.A., Inc.
..A
.A .U.S.A., Inc.
Website: www.seco-larm.com
@
E-mail: sales
seco-larm.com
®
E-942FC-IMUd.pmd
PITGW1
SECO-LARM
E-942FC-1300
E-942FC-600
Electromagnetic Gate Locks
• For use with nearly all types of outdoor sliding and swinging electric gates.
• Holding force:
- E-942FC-1300 — 1,300 pounds (591kg).
- E-942FC-600 — 600 pounds (271kg).
• Can be mounted horizontally or vertically.
• Housing dimensions:
- E-942FC-1300 — 8" x 21/2" x 11/2" (203 x 63 x 38 mm).
- E-942FC-600 — 8" x 111/16" x 19/16" (203 x 43 x 40 mm).
• Armature plate dimensions:
- E-942FC-1300 — 71/4” x 23/8” x 5/8” (185 x 61 x 16 mm).
- E-942FC-600 — 61/4” x 15/8” x 9/16” (159 x 41 x 14 mm).
• Power — 12VDC or 24VDC, with current draw of 500mA at 12VDC (250mA @ 24VDC).
• Cable — 6.5’ (2 meters), with dual-threaded conduit connector. (3’ [90cm] for E-942FC-600)
MOUNTING
A. Determine type of gate:
1. Single-swing gate (fig. 2) — Gate swings on one end, and comes to rest on a fixed gate post when closed. In this case, a typical
installation has the electromagnet fixed to the gate post, and the armature connected to the free end of the gate with a Z-bracket.
2. Double-swing gate (fig. 3) — Two gates swing in the same direction when activated. The electromagnet is fixed to the free end
of one gate, and the armature is fixed to the free end of the other via a Z-bracket. IMPORTANT:
a. A cover piece should be added to the Z-bracket to cover the electromagnet. This will help prevent unauthorized users from
prying the armature and the electromagnet apart.
b. Because of the cover piece, it is important to coordinate the swing of the gates to prevent the electromagnet from catching on
the cover piece. In this case, the gate with the armature should open before the gate with the electromagnet.
3. Sliding gate (fig. 4) — The gate slides instead of swings away from a fixed gate post. In this case, use L-brackets to mount the
electromagnet and the armature perpendicular to each other.
B. Mount the electromagnet (fig. 5) — In most cases, the position of the electromagnet will determine the location of the armature
plate. Make sure there is space to run the cable.
Note: For hollow door headers or gate posts using blind nuts (see figure 6):
1. Tape the template to the appropriate location.
2. Drill four (E-942FC-1300) or two (E-942FC-600) 9.5mm (3/8”) holes, one for each short hex screw. IMPORTANT: The holes must
be 9.5mm (3/8”). No smaller, no larger.
3. Insert a blind nut in one of the 9.5mm (3/8”) holes.
4. Put the washer on the M6x30 screw. Then put the hex tool on the screw. Then turn the screw by hand into the blind nut.
5. Use a wrench or vice-grip to tightly hold the hex tool. Then use the included Allen wrench to slowly tighten the screw until it does
not turn any further. This compresses the blind nut so that it remains permanently fixed in the hole.
6. Remove the screw.
7. Repeat steps 3) through 6) for the other blind nuts.
8.
Push hex screws into each of the screw holes in the electromagnet. Use the Allen wrench to tighten the screws into the blind nuts.
Page 1
Magnetic Gate Lock Installation Manual Magnetic Gate Lock Installation Manual
C. Mount the armature (fig. 5) — Once the electromagnet is mounted, determine the correct position of the armature. Use the
appropriate L-bracket or Z-bracket to position the armature so that it will lay against the electromagnet when activated. However,
leave a slight gap between the two so that the armature does not slam against the electromagnet when the gate is closed.
1. Put one rubber washer between two steel washers, and place them over the armature screw between the armature and the
bracket. This will allow the armature to pivot slightly around the armature screw in order to compensate for gate misalignment.
2. Make sure the guide pins are inserted into guide holes to prevent the armature from spinning.
3. Tighten the sexnut enough so the armature can withstand the force of someone attempting to pry the gate open while the
electromagnet is engaged.
4. Do not tighten the armature against the bracket. The armature must be able to pivot around the armature screw.
D. Cover the installation — Use a steel box to make the installation more attractive as well as prevent unauthorized users from prying
the armature and electromagnet apart when engaged.
E. Run the wires — The goal is to keep as little of the wires exposed as possible.
1. Run the wires into an out-of-sight location as close as possible to the electromagnet. Run them inside hollow gate posts if
possible.
2. Use standard armored cable to prevent the wires from being cut between the electromagnet and the out-of-sight location.
F. Connect the wires:
12VDC
operation
24VDC
operation
G. Test the unit.
H. Insert the tamper caps into the mounting screw access holes of the electromagnet. This should be the last step, as once the tamper
caps are in place, they are difficult to remove.
Red
White
Black
Green
Red
White
Black
Green
+ 12VDC
-
GND
+ 24VDC
-
GND
IMPORTANT: Damage caused
by improper connection will
void warranty.
Wires are non-polarity.
}
FIG. 2 - Installation on a
single-swing gate
FIG. 4 - Installation on a
sliding gate
FIG. 3 - Installation on a
double-swing gate
FIG. 5 - Basic Installation
FIG. 1 - Parts
List of Parts
1 x Electromagnet
1 x Armature plate
1 x Armature screw
3 x Large steel washers*
2 x Rubber washers*
1 x Sexnut bolt
4 x Mounting screws*
4 x Small washers*
4 x Tamper caps*
2 x Guide pins
1 x Hex key (Allen wrench)
4 x Blind nuts*
1 x Blind nut assembly set
(M6x30 screw, blind
nut, washer)
1 x Door spacer (tube)*
Page 2
Note
— E-942FC-600
*
comes with 2 steel washers,
1 rubber washer, 2 mounting
screws, no small washers,
2 tamper caps, 2 blind nuts,
and no door spacer. Also
includes a black collar for the
armature screw.
Washer*
Door
Spacer*
**
Sexnut Bolt*
Rubber
Mounting Screws*
Tamper Caps*
Armature
Plate
Steel
Washers*
Guide
Pins
Blind
Black Collar*
(E-942FC-600)
Nuts* (for
hollow
door or
gate post,
see fig. 6)
Armature
Screw**
Note — When using the optional
**
Z-bracket, do not use the door spacer and
the sexnut bolt. Also, replace the armature
screw with the short armature screw
included with the bracket, or cover the
exposed end of the long screw with the nut.
Electromagnet
FIG. 6: Mounting the blind nuts
in a hollow door or gate post
Allen wrench must be
firmly seated while
turning hex screw.
Hold with wrench or vice
grip while turning hex screw.
Blind nut - Press into
9.5mm hole as shown.
M6x30 - thread
Hex screw
φ
9.5mm
ACCESSORIES
E-942F-1300/Z - “Z” bracket for E-942FC-1300
E-942F-1300/L - “L” bracket set for E-942FC-1300
E-942F-600/Z - “Z” bracket for E-942FC-600
E-942F-600/L - “L” bracket set for E-942FC-600
Washer
Allen wrench
Hex screw
(M6 x 30 thread)
Hex tool
Door
Header
Page 3