Door does not lock
Bond status LED does not Illuminate
Door locks, but can easily be forced open
Delay in door releasing
No relay output
ELECTROMAGNETIC LOCK
y Check to make sure the wires are securely tightened to the terminal block.
y Check that the power supply is connected and operating.
y Use a meter to check the resistance of coils inside the lock. See below.
y Make sure the rubber washer is installed and free from damage.
y Make sure the electromagnet and armature plate are properly aligned.
y Make sure the contact surfaces of the electromagnet and armature
plate are clean and free from rust. y Check the power leads with a meter, and make sure 12VDC or 24VDC is
present.
y Use a meter to check the resistance of coils inside the lock. See below.
y Make sure the rubber washer is installed and free from damage.
y The electromagnet is fitted with a metal oxide varistor to prevent
interference
y Check that the power is connected properly and turned on.
y Make sure the lock is aligned properly.
y Make sure the NO/NC/COM are wired properly.
so do not install a second diode.
Electromagnetic Lock
E-941SA-600
E-941SA-1200
600-lb. (272kg)
1200-lb. (545kg)
If the Electromagnet has low or no holding force, check the resistance of the coils by
performing the following steps:
1. Remove the faceplate from the lock.
2. Disconnect the wire harness from the circuit board.
3. Using a meter, measure the resistance across:
Red / Green wires, and the Black / White wires.
4. Each coil should test at 48Ω ±10%.
5. If one or both of coils shows an open, short, or incorrect
resistance, replace the electromagnet.
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHS compliant products.
ENFORCER ELECTROMAGNETIC LOCK
g
g
A
A
p
p
V
Table of Contents:
Introduction
Features
Parts List
Specifications
Overview
Installation Applications
2
2
2
2
3
3
Installation Notes
Installation
Wiring Diagram
Maximum Wirin
Distance
Troubleshooting
Warranty
4-6
Introduction:
The E-941SA series of electromagnetic locks is the ideal way to secure a door against unauthorized
entry. When power is applied to the electromagnetic lock, it creates an extremely strong magnetic
field. The electromagnet is strongly attracted to the steel armature plate which is mounted on the
secured door. Once the electromagnet is deactivated, the secured door will function normally without
any residual magnetism.
Features:
• Anodized aluminum.
• No residual magnetism.
• MOV surge protection.
• Adjustable mounting bracket.
• Complete mounting hardware for typical installations.
• “L” bracket and “Z” brackets available for easy
mounting.
• 12/24VDC selectable.
• Detachable faceplate.
E-941SA-1K2PQ and E-941SA-600PQ also feature:
• Built-in dual-colored status LED and bond sensor to
show locking status:
Green Door is closed and locked
Red Door not closed and/or locked
Off
Door in use / No power
Parts List:
1 x Mounting plate
1 x Electromagnet
1 x Armature plate
1 x Armature screw
2 x Steel washers
1 x Rubber washer
1 x Door spacer
1 x Sexnut bolt
2 x Guide pins
4 x Long self-tapping screws
2 x Short self-tappin
2 x Hex-head mounting screws
2 x Tamper caps
1 x Allen wrench
screws
Specifications:
Operating voltage 12 or 24 VDC ±10%
Current draw
Coil resistance
Bond sensor relay 3A@12VDC
Dimensions
Operating temperature 14°~131° F (-10°~55° C)
Weight
12VDC 500mA@12VDC
24VDC 250mA@24VDC
48Ω ±10% per coil (see page 8)
Magnet
Armature
plate
600-lb 9
1,200-lb. 101/2” x 15/8” x 25/8” (268 x 42 x 67 mm)
600-lb 7
1,200-lb. 71/4” x 5/8” x 23/8” (185 x 16 x 61 mm)
7
/8” x 11/16” x 15/8” (250 x 26 x 40 mm)
1
/4” x 1/2” x 11/2” (185 x 12 x 38 mm)
600-lb 4lbs. 6oz. (2kg)
1,200-lb. 11lbs. (5kg)
4
7
7
8
8
Wiring Diagram:
Bond Status Sensor:
The Bond Status Sensor checks
ENFORCER
ELECTROMAGNETIC LOCK
LED
Relay
1A@24VDC
to make sure the door is closed,
and the electromagnet is locked.
LED Indicators:
Green Door is closed and locked
Red Door not closed and/or locked
Door in use /
Off
No power
600PQ and 1K2P models ONLY
COM
SECO-LARM
Control
*NOTE: Connect switching devices like
push-to-exit switches between the
power source and the positive terminal
on the lock. Connecting switching
devices to the negative terminal may
cause a delay in unlocking.
oltage Selection Jumpers
Position two jumpers
on all four pins for
eration
12VDC o
Position a jumper over
the two middle pins for
24VDC o
eration
Device*
Maximum Distance from Power Source to Electromagnetic Lock:
For a complete chart, please visit www.seco-larm.com
. Once the position of the mounting plate is correct,
use the four long self-tapping screws to permanently
mount the mounting plate.
ELECTROMAGNETIC LOCK
Long self-tapping screws
12.
Remove the cover from the front of the
electromagnet. Run the power leads through the
large cable access hole .
11.
Drill the cable access hole. Run the power leads
through the cable access hole in the mounting plate
and through the hole in the door frame.
Overview:
rmature screw
Rubber washer
13
. Push the electromagnet against the mounting plate
so the electromagnet ends are flush with the ends of
the mounting plate. Use the Allen wrench to screw
the hex-head mounting screws through the bottom
of the electromagnet into the mounting bracket.
Guide pins
Steel washers
Door spacer
Sexnut bolt
ENFORCER
ELECTROMAGNETIC LOCK
Short selftapping screws
Mounting plate
Long selftapping screws
Electromagnet
rmature plate
Hex-head
mounting screws
Tamper caps
14.
Cut the wires so they are long enough to connect
with the terminal block. Set the voltage using the
selection jumpers based on your input voltage.
Voltage Selection Jumpers
Position two jumpers
on all four pins for
eration
12VDC o
NOTE: Failure to correctly set the input voltage may cause
damage to the lock.
NOTE: Connect switching devices like push-to-exit
switches between the power source and the positive
terminal on the lock. Connecting switching devices to the
negative terminal may cause a delay in unlocking.
Position a jumper over
the two middle pins for
24VDC o
eration
15.
Connect the power wires according to the wiring
diagram on page 7. Test the unit. Then replace the
front cover and install the hex-head tamper caps.
NOTE: This should be the very last step, as once the
tamper caps are in place they are very difficult to remove.
Also Available from SECO-LARM:
ccess Control
Power Supply
Digital Access
Keypads
Complete line of
Electromagnetic
Locks and Strikes
Voltage
Converters or
Booster
Wired or Wireless
RTE Plates
EAP-5D1Q
6 SECO-LARM U.S.A., Inc.
SK-3123-SQ
E-941SA-1200
(shown) (shown)
ST-LA110-TTQ
(shown)
SD-7202GC-PEQ
(shown)
Installation Applications:
NOTE: When mounting the electromagnet, it may be necessary to use a “Z”-bracket, 1 or 2 “L”-brackets,
and/or plate spacers, depending on the location and the type of door and frame. Use the diagram below to
help decide whether or not an optional bracket will be necessary for installation.
See page 7 for a complete list of SECO-LARM accessories.
.
SECO-LARM U.S.A., Inc. 3
Typical
Installation
“L”-Bracket and
“Z”-Bracket
Plate
Spacers
“U” Bracket
(Typically for glass doors)
“L” Bracket
Armature-
Mounting Plate
ENFORCER
A
A
r
r
r
)
)
)
Installation Notes:
ELECTROMAGNETIC LOCK
1. Read this installation manual thoroughly. A clear understanding of the product and this
manual will make installation much easier.
2. The electromagnetic lock is designed for indoor
use ONLY.
3. The most suitable mounting location for the electromagnetic lock may require the use of
additional SECO-LARM accessories such as Z-brackets, L-brackets, and/or spacer plates.
Please see the diagram on page 3 to decide if a particular application requires any mounting
accessories. See page 7 for a complete list of SECO-LARM accessories.
4. Do not run power wires and signal wires in the same conduit as this may cause interference.
5. Do not install a diode in parallel with the electromagnetic lock as this may cause a delay
when releasing the door as well as cause residual magnetism.
6. The best location to install the electromagnetic lock is on the inside of the door that is being
secured with the wiring concealed in the frame to prevent tampering with the unit.
Installation:
1.
Fold the mounting template along the dotted line to
form a 90-degree angle.
2.
Close the door. Find a mounting location on the door
frame near the upper free-moving corner of the door,
or as close as possible to the upper corner of the
door frame opposite the hinges.
Ideal
Mounting
Location
Door Frame
ENFORCER
6. Depending on the type of door being protected, drill holes according to the diagrams below:
Hollow Metal Doo
Reinforced Doo
ELECTROMAGNETIC LOCK
Solid Core Doo
5/8” (16mm) 5/16” (8mm
Drill a 5/16” (8mm) dia. hole through the
armature-plate side of the door for the
armature screw. Then drill a 5/8” (16mm)
dia. hole for sexnut screw on the
opposite
side of the door.
7.
Put a rubber washer between the two metal washers,
and place them over the armature screw between
the armature plate and the door. This allows the
plate to pivot around the screw to compensate for
door misalignment.
1/4” (6.8mm
The rubber washer will be
sandwiched between the
two metal washers.
for M8x1.25 thread
Drill a 1/4” (6.8mm)
dia. and 1” (25mm)
deep hole, tap for
M8x1.25 thread.
1/2” (12 .7mm
Drill an 5/16” (8mm) dia. hole on the
door for the armature screw, and drill a
1/2” (12.7mm) dia. and 1” (25mm) deep
hole for the sexnut screw.
8.
Tighten the armature screw enough so that the
armature plate can withstand a break-in attempt, but
loose enough so that the armature plate can pivot
slightly. Make sure the anti-spin guide pins are in the
two guide pin holes.
5/16” (8mm)
rmature
screw
4.
3.
Place the template against
the door and frame. Mark
where the holes are to be
drilled.
Door
4 SECO-LARM U.S.A., Inc.
Door Frame
Template
Drill two holes in the frame and
three holes in the door as shown
on the template.
Door Frame
Door
5.
Use a hammer to lightly tap the
guide pins into the guide pin
holes on the armature plate.
9
. Screw the two short self-tapping screws through the mounting plate’s slotted holes, but do not over-tighten them.
Keeping them loose will allow for adjustment of the plate left or right so that the mounting plate and the armature
plate form a 90-degree angle. See the diagram below.
Metal
washers
Tip:
on the armature screw to ensure
a long-lasting installation.
Guide pins
Use a thread-locking compound
90°
Short self-tapping screws
SECO-LARM U.S.A., Inc. 5
Mounting Plate
rmature Plate
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.