Sebo X4, X5 User Manual

SEBO automatic
For Household Use Only
©Copyright SEBO America, LLC • All rights reserved.
Series
ENGLISH
U.S. Patents: 5,056,175
Wiring Diagram
Vacuum motor 1300 watts (10.8 amps) Water lift (at motor) 92 inches Airflow (at motor) 103.8 CFM Filter bag capacity 1.4 gal. Sound level 69 dBA Body weight X4-16.7 lbs / X5-16.9 lbs Motor protection electronic cut-out Working width X4-12 inches / X5-15.1 inches Brush drive toothed belt Brush speed 3100 rpm Floor adjustment automatic sensor control Cord length 40 feet Radio suppression EN 55014 Verf. 242/91
Technical Details
Technical Details 2 Wiring Diagram 2 Important Safety Instructions 3 Special SEBO Product Features 4
Automatic Power Head Height Adjustment 4 Brush Roller Obstruction – Auto Shut-Off 4 Brush Roller Deterioration Warning 4 Stationary Use Warning 4 Bag Full or Clog Warning – Auto Shut-Off 4
Identification of Parts 5 Assembly 5 Optional Attachments 5 Standard Attachments 5 Operating Instructions 6
Starting the Machine 6 Operating Positions 6 Using the Attachment Tube, Hose & Attachments 7 The Display Panel 7 The Adjustment Wheel 7
Maintenance 8
Changing the Dust Bag 8 Changing the Micro-Hygiene Filter 8 Changing the Exhaust Filter 8 Changing the Brush Roller(s) 8 Changing the Sealing Strip 8
Clog Removal 9
Clogs in the Airflow Pathway 9 Clogs in the Attachment Hose 9 Clogs in the Attachment Tube 9 Clogs in Entrance to Dust Bag 9 Clogs in the Swivel Neck 9
Trouble-Shooting Guide 10 X Series Filter Bag Housing and Handle Schematic and Part Numbers 11 X4 Base Schematic and Part Numbers 12 X5 Base Schematic and Part Numbers 13 Warranty 14 How To Contact SEBO 14
Page 2
SEBO automatic X Series Owner’s Manual
Table of Contents
Series
Page 3
1. Do not leave vacuum while plugged in. Unplug from outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not use near small children or pets. Do not allow to be used as a toy. Use of this product by children should always be supervised by an adult.
4. Use only as described in this manual. Use only manufacturer-recommended attachments.
5. Do not use with a damaged cord or plug. If vacuum is not working as it should, has been dropped, damaged, left out-doors, or dropped into water, take it to a SEBO service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run vacuum over cord. Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug – not the cord.
8. Do not plug in if switch is in the “I” (ON) position.
9. Do not use outlets above counters to plug in vacuum – damage to items in the surrounding area could occur.
10. Always carry the vacuum over steps and sills.
11. Do not handle plug or vacuum handle with wet hands.
12. Do not put any object into vacuum openings. Do not use machine with any openings blocked. Keep openings free of lint, hair, and anything that may reduce air flow.
13. Do not re-use filter (dust) bags or wash the filters.
14. Do not remove any screws from vacuum.
15. Do not vacuum up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
16. Do not use vacuum without dust bag and/or filters in place.
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE
!
When using an electrical appliance, basic precautions must always be followed.
To reduce the risk of electric shock, this vacuum cleaner has a polarized plug;one blade is wider than the other . This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Connect only to the outlet type specified on the serial number plate underneath the machine.
SAVE THESE INSTRUCTIONS.
WARNING:To reduce the risk of fire , electric shock, or injur y:
17. Turn off all machine controls before unplugging.
18. Use extra care when cleaning on stairs.
19. Do not use machine to vacuum up flammable or combustible liquids such as gasoline or use in areas where they may be present.
20. Machines can cause a fire when operated near flammable vapors or materials. Do not operate this vacuum near flammable fluids, dust or vapors.
21. Maintenance and repairs must be done by qualified personnel.
22. Use only original SEBO replacement parts.
23. Do not use vacuum as a step.
24. If vacuum is used on plush carpet or carpet with thick padding, do not leave machine standing in one place with machine turned on.
25. Do not use the operator’s handle, which inserts into the top of the dust bag housing, to carry the machine. The carrying handle is located on the backside of the machine’s bag housing.
26. Keep hair, loose clothing, fingers, and all parts of body away from vacuum openings and moving parts. Do not place fingers or other body parts under vacuum unless it is unplugged.
27. Do not place the power head over rug or carpet edges.
28. The vacuum has a manual reset thermal protector. The protector is reset by switching off the vacuum. The thermal protector needs some time to cool down after switching off! Check the vacuum for air blockages or mechanical failures before switching on.
29. Store the vacuum in a dry place at room temperature. When the vacuum is not in use, you should wrap the cord on the cable hooks.
30. Any other servicing should be performed by an authorized service representative.
Page 4
Your SEBO automatic X series vacuum cleaner is the most technically advanced upright vacuum cleaner in the world. Along with its excellent filtration system (99.9% to 0.3 microns), one of its most important features is its ability to “monitor” the resistance of the br ush roller against the floor, so that the proper cleaning height is consistently maintained. In addition, the machine has warning systems and automatic shut-off capabilities that are designed to alert the user to machine problems that, if ignored, will damage the machine or diminish performance.
Your SEBO
automatic’s five most unique features are:
1.
Automatic Power Head Height Adjustment. Based upon the resistance of the brush roller against
the floor, the power head automatically adjusts up or down to the appropriate cleaning height. The adjustment process is indicated by two green lights labeled “UP” and “DOWN” located on top of the power head. The height adjustment chosen by the machine ensures aggressive brush action, while providing optimal air flow. This prevents suffocation of air flow due to improper height selection.
2.
Brush Roller Obstruction – Auto Shut-Off. If the brush roller is obstructed, the machine will shut off
in 3 seconds and the red “CHECK BRUSH” light located on top of the power head will flash.The user should turn the switch off, unplug the machine and immediately remove the obstruction. If the user restarts the machine without removing the obstruction, the machine will again shut off in 3 seconds and the “CHECK BRUSH” light will flash.
3.
Brush Roller Deterioration Warning. The red “CHECK BRUSH” light will illuminate (after a
10 second delay) to notify the user that the brush roller is too worn and, therefore, should be replaced. The light will remain illuminated until the worn brush roller is replaced, but the machine will continue to operate in the meantime.
4.
Stationary Use Warning. When the machine has its handle in the upright-locked position, it is
designed to disengage the brush roller from the floor by raising the height of the power head. If the power head reaches its highest brush height but is still engaged in the carpet, the “CHECK BRUSH” light will slowly flash to alert the user.This can occur on extremely high-nap carpet, such as loose-pile shag, or on carpets with extraordinarily thick padding underneath. However, it is typically caused by the user pulling forward on the machine while using the attachment hose or active wand. This feature was designed to be an alert to the user to “take care” while the machine is stationary. An operating machine should not stand stationary on the floor for inappropriate periods of time.
5.
Bag Full or Clog Warning – Auto Shut-Off. If the vacuum’s air flow pathway becomes restricted
due to a full bag or the existence of a clog, the red “BAG FULL OR CLOG” light located on top of the power head will illuminate. If the user ignores this warning for approximately 30 seconds, the machine will shut off and the “BAG FULL OR CLOG” light will flash. The user should turn the switch off, unplug the machine and immediately insert a new bag or remove the clog (to remove a clog, refer to the Clog Removal section on page 9). If the user restarts the machine without having solved the problem, the “BAG FULL OR CLOG” light will again illuminate and the machine will shut off in 30 seconds.
SPECIAL SEBO PRODUCT FEATURES
The control panel is located on the power head.
Page 5
1. Handle grip
2. On/Off switch
3. Handle assembly
4. Retaining ring
5. Cover release flap
6. Dust bag housing
7. Front cover
8. Housing release button
9. Power head with brush
10. Cable (cord)
11. Attachment tube handle
12. Attachment hose
13. Handle catch
14. Carr ying handle
15. Cable (cord) hook
16. Attachment tube (active wand)
17. Crevice nozzle
18. Upholster y nozzle
19. Foot pedal
20. Swivel neck
21. Suppor t lever
22. Projection tab
23. Connecting tube
Identification of Parts
Place the power head (9) on the floor with the swivel neck (20) and the suppor t lever (21) upright. Hold the dust bag housing (6) vertically and place it over the swivel neck and support lever. Push firmly and evenly down so that the housing release button (8) snaps outward to its “locked” position.
Slide the dusting brush clamp (24) onto the handle tube and tighten the screw. The han­dle of the dusting brush (25) will now snap into the clamp.
To lock the handle (3) to the dust bag hous­ing (6), turn the handle catch (13) at the handle joint of the filter bag housing (6) for­ward to “open” position. Then slide the han­dle assembly (3) in as far as possible and lock it in by turning the handle catch to the closed position.
Push the black end of the attachment hose (12) into the connecting tube (23) so that it clicks into place. Inser t the attachment tube (16) into the swivel neck and push the han­dle (11) over the projection tab (22).
Insert crevice nozzle (17) and upholstery nozzle (18) into the recesses in the back of the machine.
Attach dusting brush clamp with screw
24
25
25
18
17
24
Optional Attachments
41.Wall and floor brush - Part # 1325 HG
42.Turbo br ush for stairs - Part # 6179 AM
43. Radiator brush - Part # 1496 HG
44. Extension hose (9’3”) - Part # 1495 AM
45. Straight tube - Part # 1084 HG
46. Flat upholster y nozzle - Part # 1090 HG
Also available for odor control - the combined micro/charcoal filter - Part # 5425 AM
45
Standard Attachments
17. Crevice nozzle
18. Upholster y nozzle
24. Dusting brush clamp
25. Dusting brush
Assembly
42
43
46
44
41
Note
All illustrations shown in this manual represent the X4 model except where part numbers and instructions are different for each model. In those instances, illustra­tions for both the X4 and X5 will be shown.