Sebo K3, K2 User Manual

OWNER’S MANUAL
For Household Use Only
TABLE OF CONTENTS
Technical Details 2 Important Safety Instructions 3
pecial AIRBELT K Product Features 4
S Optional Power Heads for the AIRBELT K3 6 Optional Attachments, Accessories, Bags and Filters 6 Identification of Parts 7 Assembly 7 Standard Attachments 7 Optional Attachments 7 Operating Instructions 8
Additional Operating Instructions for K3 with Power Head 9
Using the Telescopic Tube, Hose & Attachments 10 Use and Maintenance of Brushes and Heads 10
The Parquet Nozzle 10 The Combination Nozzle 10 The Turbo Nozzle 10
Vacuum Maintenance 11
Changing the Filter Bag 11 Changing the Micro-Hygiene Filter 11 Changing the Exhaust Filter 11 Changing the AIRBELT 11
Clog Removal 12
Clogs in the Head or Brush 12 Clogs in the Telescopic Tube 12 Clogs in the Hose 12 Clogs in Entrance to Filter Bag 12
Trouble-Shooting Guide 13 AIRBELT K2 Schematic and Part Numbers 14 AIRBELT K3 Schematic and Part Numbers 15 Warranty 16 How To Contact SEBO 16
TECHNICAL DETAILS
Vacuum motor 1250 watts (10.6 amps) Water lift (at motor) 110 inches Airflow (at motor) 120 CFM Filter bag capacity .8 gallons Sound level 63 dBA Body weight 12 lbs Motor protection thermal cut-out Cord length 20 feet Range 31 feet
Technical details may be subject to change.
2
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE
!
When using an electrical appliance, basic precautions must always be followed.
To reduce the risk of electric shock, this vacuum cleaner has a polarized plug; one blade is wider than the other. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Connect only to the outlet type specified on the serial number plate underneath the machine.
SAVE THESE INSTRUCTIONS.
WARNING: To reduce the risk of fire, electric shock, or injury:
1. Do not leave vacuum while plugged in. Unplug from outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not use near small children or pets. Do not allow to be used as a toy. Use of this product by children should always be supervised by an adult.
4. Use only as described in this manual. Use only manufacturer-recommended attachments.
5. Do not use with a damaged cord or plug. If vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, take it to a SEBO service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run vacuum over cord. Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug – not the cord.
20. Machines can cause a fire when operated near flammable vapors or materials. Do not operate this vacuum near flammable fluids, dust or vapors.
21. Maintenance and repairs must be done by qualified personnel.
22. Use only original SEBO replacement parts.
23. Do not use vacuum as a step.
24. If vacuum is used on plush carpet or carpet with thick padding, do not leave machine standing in one place with machine turned on.
25. While the vacuum is in use, the power cord should be unwound from the cable reel at least two thirds of its length. Hold plug when rewinding onto the cord reel. Do not allow plug to whip while rewinding.
26. Keep hair, loose clothing, fingers, and all parts of body away from vacuum openings and moving parts. Do not place fingers or other body parts under vacuum unless it is unplugged.
8. Do not plug in if switch is in the “I” (ON) position.
9. Do not use outlets above counters to plug in vacuum – damage to items in the surrounding area could occur.
10. Always carry the vacuum over steps and sills.
11. Do not handle plug or vacuum handle with wet hands.
12. Do not put any object into vacuum openings. Do not use machine with any openings blocked. Keep openings free of lint, hair, and anything that may reduce air flow.
13. Do not re-use filter bags or wash the filters.
14. Do not remove any screws from vacuum.
15. Do not vacuum up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
16. Do not use vacuum without filter bag and/or filters in place.
17. Turn off all machine controls before unplugging.
18. Use extra care when cleaning on stairs.
19. Do not use machine to vacuum up flammable or combustible liquids such as gasoline or use in areas where they may be present.
27. Do not place the power head over rug or carpet edges.
28. The vacuum has a manual reset thermal protector. The protector is reset by switching off the vacuum. The thermal protector needs some time to cool down after switching off! Check the vacuum for air blockages or mechanical failures before switching on.
29. Store the vacuum in a dry place at room temperature. When the vacuum is not in use, you should rewind the cord onto the cord reel
30. Any other servicing should be performed by an authorized service representative.
31. The hose contains electrical wires. Do not use if damaged, cut, or punctured. Avoid picking up sharp objects.
32. Always unplug vacuum before connecting or disconnecting either hose or power head.
33. Use a SEBO power head only in combination with a SEBO vacuum cleaner.
34. Do not connect power head to a malfunctioning or damaged vacuum.
3
SEBO AIRBELT K PRODUCT FEATURES
SEBO Vacuums Save Money! – SEBO vacuums are the highest quality machines available. In fact, if properly maintained, SEBO vacuums can save ordinary residential users hundreds of dol-
ars by providing excellent performance for ten to fifteen years
l or more. Typical vacuums perform poorly and usually do not last beyond two years. So, in the long run, SEBO vacuums cost less money than the five to six other vacuums purchased during that time period.
Outstanding Warranty Coverage – SEBO is con­fident about the quality of all its vacuums. Therefore, all models include a five-year war­ranty on the motor and all non-wear parts and a 1-year warranty on labor charges.
Brush Obstruction Light & Auto Shut Off – A warning light will quickly flash, the brush roller will immediately stop spinning and the vacuum will shut off, if an obstruction becomes jammed in the brush roller. user should turn the power switch off, unplug the machine, and immediately remove the obstruction. If the user restarts the machine without removing the obstruction, the power head will again shut off and the amber light will turn on. from breaking and protects the motor from damage.
Bag Full or Clog Light & Auto Shut Off – A warning light will illuminate and the machine will automatically shut off, when it senses a full bag, a clog in the airflow path­way, or an excessively dirty micro filter. vacuum’s airflow pathway becomes restricted due to a full bag or the existence of a clog, the amber “BAG FULL OR CLOG” light (located on top of the canister near the ON/OFF power control knob) will illuminate. If the user ignores this warning, the suction motor will heat up due to the lack of cooling provided by the airflow. Once the motor reaches a certain temperature it will shut off to protect itself from damage. The user should turn the switch off, unplug the machine and immediately insert a new bag or remove the clog (to remove a clog, refer to the Clog Removal section on page 12). After approximately 30 minutes, the motor will have cooled and the vacuum can be restarted. If the airflow is still restricted, the “BAG FULL OR CLOG” light will again
illuminate and the machine will shut off. damage to the motor due to overheating.
The
This prevents the belt
If the
This feature prevents
air belt disperses the filtered exhaust air around the canister which provides quiet, gentle air flow. SEBO’s unwavering attention to the complete sealing of the machine ensures no dirt escapes around the microfilters.
Liberation from Bagless! SEBO Bags are Hygienic – The three-layer filter bag is an
integral part of SEBO’s filtration system because it effectively contains nearly all dirt captured by the vacuum. And SEBO bags can be sealed when full, so no dust can escape into the air during disposal. In con­trast, a lot of dust becomes airborne when emptying the dirt containers of bagless vacuums, and their micro filters quickly clog and must be replaced often, or a loss of suction will occur. And bagless vacuum micro filters are expensive, usually cost­ing much more than SEBO’s filter bags.
Micro Filters are Inexpensive and Easy to Change – Unlike most other vacuums, SEBO’s replacement micro filters are reasonably priced and can be easily changed in seconds, with­out any tools. And the micro filters last a long time before replacements are necessary because nearly all dust particles and debris are first captured by the three-layer filter bags.
Remarkably Quiet Operation – A SEBO vacuum is so quiet, it will not scare pets, and the feature will be appreciated by family members.
SEBO three-step filtration system
c
a
Incorrect Height Setting or Brush Deterioration Light – To ensure optimum
cleaning at all times, a warning light will illu­minate to indicate when the brush height is set too high for effective cleaning, or when the brush roller should be replaced due to excessive wear.
Anti-allergy Hospital-grade, S-class Filtration –
An excellent choice for users with allergies or asthma. in Europe, the AIRBELT K vacuums provide the user with S-Class filtration of 99.9% of particles to
0.3 microns. This is accomplished by the SEBO three-step filtration system. First, the three-layer full-size filter bag (a) collects the vast majority of the debris. Then, the remainder of the particles are col­lected by the hospital-grade microfilter (b). Finally, the micro­exhaust filter (c) cleans the exhaust air that the vacuum emits. The
4
Certified by leading Allergy foundations
b
d
S
u
p
e
r
q
u
i
e
t
a
i
r
e
s
u
a
x
h
a
l
l
a
t
!
d
n
u
o
r
SEBO AIRBELT K PRODUCT FEATURES
Designed for All Floor Surfaces.
AIRBELT K3: Five Power Head Choices –
The AIRBELT K3 has an electrified telescop­ic tube designed to accommodate any choice from the following five power heads: ET-1, ET-2, ET-H and DISCO. Each power head has unique features and benefits, but all power brushes are designed to provide thorough brushing for optimal cleaning of
arpets. The DISCO power head enables the vacuum to polish
c
ard floors.
h
AIRBELT K3: Cleaning Dimensions – The ET-1 power head is 12-inches wide, with a cleaning with of 10 ET-2 is 14 ET-C power head is 14-inches wide, with a 12 width, and the ET-H is 11
3
4-inches wide, with a 13-inch cleaning width. The
3
4-inches wide, with an 111⁄2-inch
cleaning width. The DISCO is 13-inches wide, with an 11
K3 with DISCO
1
2-inches, and the
1
2-inch cleaning
3
4-inch
polishing width.
Both Carpet and Hard Floor Cleaning – With a power brush to clean carpets and a parquet nozzle to clean hard floors, the AIRBELT K3 provides all the flexibility needed to care for a vari­ety of floor surfaces. The parquet nozzle comes standard. The K3 vacuum can morph into a hard floor polisher, by adding a SEBO DISCO head.
Four-level Manual Brush Height Adjustment – The brush height can be adjusted up or down for optimum cleaning.
Quick-release Connections – The AIRBELT K models allow for quick and convenient connection of telescopic tubes, power brush heads, accessory cleaning heads and on-board tools.
Shock Absorber Provides Furniture and Wall Protection – The “AIRBELT” bumper
hat surrounds the K canisters acts as a
t protective barrier. The soft foam bumper with its durable covering protects furniture, walls and the vacuum itself from damage during use.
ersonalized Vacuums – AIRBELT canister vacuums can be
P
personalized with a replacement AIRBELT bumper cover avail­able in eight patterns and colors.
Powerful Vacuum Motors Provide Excellent Cleaning – The canister suction motor is 1,250 watts, and the power head motor is 175 watts (ET-1), for a total of 1,425 watts.
Comfortable Ergonomic Handle – The AIRBELT handles are ergonomically designed and positioned to reduce wrist and arm fatigue. For extra comfort, an additional swivel is built into the handle-to-hose connection.
High-quality Telescopic Tube and Hose – On the K3, the power cord is built inside the telescopic tube and suction hose. This eliminates unsightly external wires and enables unobstructed and convenient handle height adjustment.
Variable Power Control on Handle – The vacuum’s suction power can be adjusted from 0 to 1,250 watts by a slider switch con­veniently located on the handle.
Mid-sized Canister Vacuum – The SEBO AIRBELT K3 and K2 are considered mid­size canister vacuums, which means they are machines medi­um in size that offer mid-sized, on-board attachments and a mid-sized filter bag with a dirt capacity of .8 gallons. The K machines also weigh four-pounds less than the C machines.
Three On-board Tools – The vacuum comes standard with a crevice tool, dusting brush and upholstery nozzle. The dusting brush is mounted on the telescopic tube, and the crevice and upholstery nozzles are on the canister. Many optional acces­sories are also available.
Dusting Brush
Crevice Nozzle
Upholstery Nozzle
Rubber Coated Wheels and High Quality Castors – The quality of the wheels and
castors on SEBO canisters prevent damage to floors and rotate 360
0
for easy maneu-
verability.
Large Operating Range – A 31-foot operat­ing range saves time because it minimizes the number of elec­trical outlets needed during use.
AIRBELT K2: The SEBO AIRBELT K2 is a straight-suction vacu­um. As a result, it differs from the AIRBELT K3 in the following two ways:
Can Not Use a Power Brush – The AIRBELT K2 does not have an electrified telescopic tube and hose; therefore, it does not accommodate an electrified power brush. Instead, it comes standard with a Turbo Nozzle (an air-driven brush head) for clean­ing rugs and carpet. It also comes standard with a Parquet Nozzle for cleaning hard floors.
Turbo Nozzle
Parquet Nozzle
Variable Power Control on Canister Body – Because the AIRBELT K2 does not have an
electrified hose and handle, its variable power control switch is located on the can­ister body, not the handle.
Brushless Cleaning Capability – The ET-1 or ET-2 power heads can provide gentle, brushless cleaning of delicate rugs or hard floors because the brush roller may be switched off, but suc­tion will continue.
5
OPTIONAL POWER HEADS FOR THE AIRBELT K3
Deep clean your carpet with a SEBO power head, or polish your hard floor with a SEBO DISCO Ultra-High-Speed floor polisher! SEBO power heads and the DISCO polisher are vir­tually maintenance free, and their electronic overload protec­tion feature extends belt life by automatically shutting off
ower, if a brush roller or polisher pad jams.
p
3
The SEBO ET-H Power Head (11
1
2” cleaning width) – Its patented new
11
4” wide,
design offers dual-edge cleaning and a manual brush pressure control, for opti­mal cleaning from one type of flooring to another. The steering mechanism built into the swivel neck helps to easily clean around obstacles. It also has a brush height and brush wear warning light.
1
The SEBO ET-1 (12” wide, 10 width) and ET-2 Power Heads (14
2” cleaning
3
4” wide,
13” cleaning width) – These power heads
deliver cleaning flexibility because their brush action aggressively cleans carpet­ing, and the brush may be switched off to clean hard floors and delicate rugs. The steering ability of the swivel necks help to easily clean around obstacles, and their L­shaped heads provide maneuverability around furniture and under cabinets. They also have brush height and brush wear warning lights.
The SEBO DISCO (13” wide, 11
ever been easier to make hard floors shine! The SEBO
n DISCO floor polisher can both vacuum and polish, for a super-gloss finish. It can be attached to the FELIX uprights or to the AIRBELT C or K canisters. Its suc­tion removes fine dust (dust from fully dried floor polishing product) during pol-
shing, and the 2,000 rpm disc speed will
i create a high-gloss shine for a fantastic hard floor finish. Additional DISCO features include automatic height adjust­ment, automatic safety shut-off caused by blockages or other reasons, a soft bumper to protect walls and furniture, a highly maneuverable swivel neck, and three rubber coat­ed castors to protect the floor.
3
4” polishing width) – It’s
OPTIONAL ATTACHMENTS, ACCESSORIES, BAGS & FILTERS
In addition to the standard on-board tools, a variety of optional attachments are available. The nine-foot extension hose (extends suction hoses) and the 19-inch extension tube are very popular because they create useful tools for cleaning stairs and out-of-reach areas. These two items are sold separately or as part of multiple item attachment kits. Another popular attachment is the hand held turbo brush for removing pet hair from upholstery.
SEBO FRESH
K Filter Bags Extension Tube Nine-foot Extension Hose Hand-held Turbo Brush Radiator BrushK Service Box
6
SEBO filter bags can be purchased in boxes of eight and fil­ters are sold separately. Also, bags and filters can be pur­chased together in model-specific kits called “Service Boxes.” SEBO bags, filters and accessories are reasonably priced and widely available.
To create a fresh scent while vacuuming, “SEBO FRESH” is available. To use, deposit a scented stick in the filter bag.
IDENTIFICATION OF PARTS
. Handle grip
1
2. Power control slider (K3 only)
3. Handle release button
4. Telescopic tube
5. Slide button . Power cable
6
7. Tool release button
8. Combination nozzle
9. On/Off power control knob
10. Warning light
11. Upholstery Nozzle
12. Mains cable (K3 only)
13. Hose
4. Exhaust filter cover
1
15. AIRBELT shock absorber
16. Carrying handle
17. Suction opening
18. Hose release button (K3 only)
9. Hose neck
1
20. Crevice nozzle
21. Parking attachment holder
22. Power cable shroud
23. AIRBELT clip
24. Parking attachment holder
25. Filter bag cover release catch
26. Filter bag cover
1 2
2
1
3
3
1
4
5 6
10
9
11
Standard Attachments
27
28
32
35a
33
29
20
11
35b
20. Crevice nozzle
11. Upholstery nozzle
31
30
34
36
27. Dusting brush clip
28. Dusting brush
Brushes, Heads, Optional Attachments
29. Premium Parquet nozzle - standard for the K3 Volcano, Red and Onyx. Optional for the K2 Midnight Blue - Part #7200DG
30. Combination nozzle - standard for the K2 Midnight Blue. Optional for the K3 Volcano, Red & Onyx and K2 Hunter Green - Part #7260DG
31. Turbo nozzle - standard for the K2 Hunter Green. Optional for the K3 Volcano, Red & Onyx and K2 Midnight Blue Part #6780ER
32. Radiator brush - Part #1496HG
33. Straight tube (20 in.) - Part #1084HG
34. AIRBELT - Available in several colors and patterns - Part #6047AM/01-08
17
26
14
19
18
25
7
8
15
16
24
15
20
21 22
23
Power Heads - optional for the K3: 35a. ET-1 Power head - Red: Part #9299AM; Orange: Part #9272AM; Onyx: Part #9951AM
35b. ET-2 Power head - Red: Part #9250AM 36. ET-H Power head - Red: Part #9257AM
ASSEMBLY
Push the neck (19) of the hose (13) into the suction opening of the canister (17). K3: The notch in the suction opening will line up with the raised bar on the neck. When the notches are lined up correct­ly, the neck will snap firmly into place. To release the hose from the suction opening, press the release tab (18) on the neck of the hose (19), and pull the neck out. K2: To release the hose from the suction opening, squeeze the tabs (37) on the retaining ring and pull the neck out.
Attach the short mains cable (12 - K3 only) on the underside of the handle by connecting one cable plug where the hose connects to the handle and the other where the handle connects to the telescopic tube.
Connect the handle (1) to the top of the telescopic tube (4). Snap in place. To release the telescop­ic tube (4) from the handle, push the handle release button (3) and slide the handle out.
Attach the head or brush to the bottom of the telescopic tube (4). Insert the bottom of the telescopic tube into the neck of the head or brush (38) until it locks into place; or line up the square hole in the telescopic tube with the notches in the front of the neck, and snap firmly into place. To release a head or brush from the telescopic tube (4), push the release button (7), and pull the head or brush tool off the end of the telescopic tool. The release button (7) is in the same position on all of the heads, brush­es and power heads.
To attach the dusting brush clip (27), locate the two raised ridges on the upper end of the telescopic tube (4) just below the handle. Push the clip onto the tube directly below the ridges then slide the clip up until it locks onto the ridges. Snap the dusting brush (28) into the holder.
NOTE: To attach a SEBO power head (ET-H, ET-1 or ET-2) to your K3 canister, please refer to your power head owner’s manual for instructions. Attaching incorrectly could cause damage.
NOTE: All illustrations shown in this manual represent the K3 model except where part numbers and instructions are different for each model.
K2
37
K3
19
17
3
4
7
17
19
18
1
4
38
7
OPERATING INSTRUCTIONS ALL K VACUUMS
Starting The Machine
Before turning on your canister, make sure that you have a firm hold on the handle grip to keep the machine from moving forward.
1. With the canister main power control knob (9) in the OFF position, grasp the plug and pull the power cord (6) out from the power cable recess (22). The power cord (6) should be unwound from the cable reel at least two thirds of its length. Note: do not over-extend the cord.
2. Plug the polarized power cord into a 120 volt wall outlet located near the floor.
3. Press the main power control knob on the base of the canister (9) gently with your foot or hand. The green light (10) will illuminate indicating that the power is on (K3 model only).
Suction Control
K2 users: the suction control dial is located on the top side of the canister on the power control knob
(9). Rotate the dial counter-clockwise for maximum suction. Rotate clockwise to reduce suction for vacuuming curtains or delicate fabrics.
K3 users: for information on suction control, refer to page 9 of this manual.
- Figure 3
Operating the Machine
Adjust the telescopic tube (4) to the correct height by pushing the slide button (5) and gen­tly pulling the tube out to lengthen, or pushing it in to shorten. Release the slide button (5) to lock the tube to the adjusted height.
- Figures 1, 2 & 3
- Figures 4, 5, 6 & 7
9
22
6
Figure 1
10
9
Figure 2 - K3
When changing heads, always switch the vacuum off with the power control knob (9), and then unplug the power cord.
The “bag full or clog” light (#10, figure 2) works correctly only at full power. At lower power levels, the “bag full or clog” light may illuminate incorrectly. Check the status of the filter bag regularly at full power. If the light remains illuminated at full power, and the filter bag is not full, check for clogs (see page 12).
To retract the cord, switch the vacuum off, unplug it from the outlet, then gently pull on the cord near the plug recess (22) and the mechanism will automatically rewind. Before rewinding the cable, always switch off and unplug the vacuum. Hold the plug while rewinding the cord onto the cord reel. Avoid letting the plug whip while rewinding.
The vacuum can be stored with the canister in a hori­zontal or vertical position. The Parquet nozzle, Combination nozzle and Turbo nozzle have a parking tab located on the front of the neck (39). Insert the parking tab into the upper side of the parking groove and slide down firmly. For vertical storage, or for easy carrying, use the parking slot on the underside (24). For horizontal storage, use the parking slot on the end of the canister (21).
39
Figure 3 - K2
5
4
Figure 4
21
24
Figure 5
!
WARNING!The quality, condition, coating, texture, age and manufacturing technique of all floor surfaces vary.
Therefore, vacuums with rotating brushes, including your SEBO, may damage some floor coverings or surfaces. Some types of high-gloss hardwood floors, cushion vinyl, berber carpets, long shag, and delicate or hand-woven carpets are particularly vul­nerable to damage by rotating brushes. When possible, consult the materials supplied by your flooring manufacturer for infor­mation on proper upkeep and cleaning. To ensure that your new SEBO vacuum cleaner is compatible with your floor, please
test the vacuum cleaner on each type of flooring surface in a small inconspicuous area to determine if any damage occurs. If damage occurs, stop using the vacuum cleaner immediately!
8
Figure 6
Figure 7
ADDITIONAL OPERATING INSTRUCTIONS FOR K3 WITH POWER HEAD
Please refer to your power head owner’s manual for more information
Starting The Machine
and Suction Control - Figures 1, 2, 8, 9,
10a & 10b
Before turning on your canister, make sure that the vacuum handle is in its upright locked position (figure 8).
1. With the canister main power control knob (9) in the OFF position, and the power
ontrol slider on the handle (#2, figure 9) in the OFF position, pull the power cord
c out from the base of the canister (figure 1). The power cord should be unwound from the cable reel at least two thirds of its length. Note: do not over-extend the cord.
2. Plug the polarized power cord into a 120 volt wall outlet located near the floor.
3. Press the main power control knob (9) on the base of the canister gently with your foot or hand. The green light (10) will illuminate indicating that the power is on (figure 2).
4. Slide the Power Control Slider (2) to the ON position (the slider will “click” when it is pushed out of the OFF position). It will then slide freely between 0 suction and MAX suction. Set the slider to the suction desired. Release the foot pedal (#41, figure 10a) on the ET-1 or ET-2 power head or, for the ET-H power head, lower the handle (figure 10b).
Operating The Machine
When the power head is on with the handle in the upright locked position (see figure 8 above), the brush roller will not spin.
To release the ET-1 or ET-2 power head from the upright locked position, press down on the foot pedal (#41, figure 10a) and lower the handle into the normal operating position and push the button on the top of the power head (#40, fig­ure 8) to engage the brush roller. The green light on the power head will illumi­nate.
To release the ET-H power head from the upright locked position, gently place your foot on the power head for leverage and lower the handle into the operat­ing position (figure 10b). The brush roller will then start spinning. The amber indicator light may flicker for a few seconds when you lower the handle - this is normal.
- Figures 10a & 10b
ON position - Slide the slider down toward
OFF position - Pull the slider up to 0 suc-
40
ET-H power head
ET-1 power head
Figure 8
2
Figure 9
0 = Zero Suction
MAX = Maximum Suction
0 suction till it “clicks” out of position.
tion then continue pulling the slider up
until it “clicks” into the OFF position.
The handle can be lowered to a horizontal position useful for vacuuming under beds.
You may adjust the suction control with the power control slider (2) as you vac­uum different surfaces or when using the accessory tools. For optimal cleaning and brushing, operate the machine at the maximum suction power setting and push the power head slowly over the carpet.
When the canister’s main power control knob is in the ON position, you may turn the power head off and on with the power control slider (2). To turn the power head off using the power control slider, pull the slider to 0 suction, then contin­ue pulling the slider up until it “clicks” into the OFF position. The green power head light will then shut off (the green light on the canister (10) will remain illu­minated until the vacuum is powered off using the main power control knob).
Always turn the power off on both the canister and the power head when changing heads or unplugging the vacuum. Slide the power control slider on
the power head to its OFF position, press the power control knob on the base of the canister (9) gently with your foot or hand, then unplug the canister to com­pletely shut down the power when changing heads or storing the vacuum.
To retract the cord, switch the vacuum off, unplug it from the outlet, then gen­tly pull on the cord near the plug recess (22) and the mechanism will automat­ically rewind. Before rewinding the cable, always switch off and unplug the vac­uum. Hold the plug while rewinding the cord onto the cord reel. Avoid letting the plug whip while rewinding.
41
Figure 10a
Figure 10b
9
Using the Telescopic Tube, Hose & Attachments - Figures 11 & 12
The telescopic tube (4) is useful for vacuuming corners and hard-to-reach areas. You may use the telescopic tube without a brush, power head or attachment. To remove a brush or power head, switch off the power control knob (9) and unplug the vacuum. Then, press the tool release button (7) and pull the tube out. The crevice nozzle (20) and dusting brush (28) may be inserted onto the end of the tube. To use the upholstery nozzle (11), fit it onto the end
f the crevice nozzle (20). It is not necessary to turn off the vacuum while switching the stan-
o dard attachments (the crevice nozzle, upholstery nozzle or dusting brush). After use, switch off the power, unplug the vacuum and remove attachment. Re-insert the telescopic tube into the power head or brush, turning the tube if needed, until you hear it click into place.
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power head user’s manual for more detailed instructions for connecting your power head.
To use the hose without the telescopic tube, switch off the power and unplug the vacuum. Push the handle release button (3) and pull the HANDLE out of the end of the telescopic tube. Do not try to separate the hose from the handle! Insert the crevice nozzle (20) or dusting brush (28) onto the end of the handle. To use the upholstery nozzle (11), fit it onto the end of the crevice nozzle (20). After use, switch off the power, unplug the vacuum and remove the attachment. Re-insert the handle into the telescopic tube making sure it is seated correct­ly and snap it into place.
11
USE AND MAINTENANCE OF BRUSHES AND HEADS
Figure 11
20
Figure 12
4
7
4
1
20
Always unplug vacuum from outlet before dismantling
!
any part of machine!
To remove a brush or power head, switch off the power and unplug the vacuum. Then, press the tool release button (7) and pull the tube out.
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power head user’s manual for more detailed instructions for operating and maintaining your power head.
Premium Parquet nozzle - Figure 13
The parquet nozzle (29) is specially designed for use on hard surfaces. The brush should be cleaned regularly. Remove the parquet nozzle from the telescopic tube to clean. Fibers and hair can be pulled out of the bristles manually, or vacuum the bristles with with the tele­scopic tube. The brush strips are removable for cleaning and replacement.
Combination nozzle - Figure 14
The Combination nozzle (30) is adjustable for carpet or hard floors. To set for carpet, slide the up arrow button (42) to the right until it clicks into place. The hard floor dusting brush will raise up allowing the head to move over the carpet. To set for hard floors, slide the down arrow button (43) to the left until it clicks into place. The brush will lower to gently sweep your floors. The slider in Figure 14 is set in the position for hard floors. The brush should be cleaned regularly. Remove the Combination nozzle from the telescopic tube to clean. Fibers and hair can be pulled out of the bristles manually, or vacuum the bristles with with the telescopic tube. The brush strip is removable for cleaning and replacement.
Figure 13
L
L
Figure 14
29
42
30
43
Turbo Nozzle - Figure 15
The Turbo nozzle (31) has an air-driven rotating brush for gentle brushing of carpets. The Turbo nozzle can be adjusted for high and low pile carpet. To adjust the head for high pile carpet, push the slider button (44) to the right. For low pile carpet, push the slider button (44) to the left. The slider in Figure 15 is set in the low pile position. The rotating brush should be cleaned regularly. Remove the Turbo nozzle from the telescopic tube to clean. Remove fibers and hair from the brush manually.
10
44
L
Figure 15
31
L
VACUUM MAINTENANCE
lways unplug vacuum from outlet
A
!
before dismantling any part of machine!
Changing the Filter Bag - Figure 16
To change the filter bag (45), set the canister upright (as shown in figure 13), press the cover release catch (25) and lower the filter bag cover (26). Grasp the green filter bag sealing plate (46), slide the plate from the holder (48) and push the filter bag cap (47) on to seal the bag. Slide the sealing plate (46) of a new bag into the bag holder slots (48) and push it in firmly until it locks into place. Close the cover, making sure it snaps shut completely. You may find it convenient to store the bag cap inside the filter bag housing below the filter bag. Do not re-use the filter bags. Note: the nature of the contents of the fil­ter bag will affect the point at which it needs changing. Fine dust may require an earlier change even though the bag is not full. Fluff or hair allows air to pass through easily, so the filter bag may overfill before the amber “bag full” light illuminates.
The “bag full or clog” light works correctly only at full power. At lower power levels, the “bag full or clog” light may illuminate incorrectly. Check the status of the filter bag regularly at full power.
Changing the Exhaust Filter - Figure 17
The exhaust filter (51) needs to be changed when it becomes extremely dirty or clogged with dust, or after approximately 10 to 20 filter bags have been used. To change the exhaust filter, set the canister flat on the floor as shown in figure 17. Remove the printed cover on top of the machine (14) by lifting the catch (49) in the upholstery nozzle recess (see inset, figure 17). Pull out the filter using the handle (50) and fit the new filter into the same position. The filter handle should point toward the upholstery nozzle when it is folded down. Fit the tabs on the bottom of the cover (14) into the grooves and snap the cover down firmly.
Changing the Micro-Hygiene Filter - Figures 16 &18
After 10 to 20 bags have been used, change the micro-hygiene filter (52). To remove the micro-hygiene filter, set the canister upright (as shown in figure
16). Press the cover release catch (25) and lower the filter bag cover (26).
Remove the filter bag, then remove the cover by sliding it up and out of the grooves (53). Pull the old filter out (52) and slide the new filter into the same position. Replace the filter bag, then re-insert the cover by fitting the tabs into the grooves (53) on both sides and sliding it in and down. Push the cover closed, making sure it snaps shut completely.
26
Filter Bags
Part #6629AM
49
14
51
K Filter Set:
Exhaust Filter
and
Micro-Hygiene
Filter
Part #6696AM
25
45
26
47 46
48
45
26 25
Figure 16
50
51
Figure 17
5353
K Service Box - 8 Filter Bags, Exhaust Filter and Micro-Hygiene Filter Part #6695AM
52
Changing the AIRBELT - Figure 19
If damage occurs to the AIRBELT cover, it will need to be replaced. To remove the AIRBELT (15), pry off the clip (55) by inserting the tip of a slot-head screw­driver under the bottom side of the clip. Push downward on the screwdriver until the clip pops off. Grasp the end of the AIRBELT cover and pull - the AIR­BELT cover will peel off. The foam bumper (54) remains on the vacuum. To replace the AIRBELT, insert the side ribs of the AIRBELT into the grooves (56). Start at the back, insert rib into one groove (56), and while holding it down, stretch the AIRBELT cover around the foam (54) into the opposite groove (56). Continue around the vacuum. Secure the ends with the clip (55).
SEBO AIRBELT covers are available in a variety of colors and patterns. See your SEBO dealer for available selection.
Note: Never operate the vacuum with incorrectly attached filters or without filters, bag, AIRBELT or filter bag housing cover (26). Do not re-use filter bags. Do not wash and re-use filters.
AIRBELT Cover - Part #6047AM/01-08
52
Figure 18
54
15
55
56 54 56
Figure 19
11
CLOG REMOVAL
!
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power head user’s manual for more detailed instructions for removing clogs in your power head.
f the “bag full or clog” warning light (10) remains illuminated after the filter bag
I has been changed and the filters are in good condition, there is likely a clog in the system.
Always unplug vacuum from outlet before removing
any clogs!
Clogs in the Head or Brush - Figure 20
Clogs in the swivel neck (57) of a head or brush can be cleared by first pressing the tool release button (7) and removing the brush or head. Check inside the swivel neck channel (56), and clean out pathway.
Clogs in the Telescopic Tube - Figure 20
Remove head from telescopic tube (4) by pushing the tool release button (7) and pulling the tube out. Remove the hose from the top of the telescopic tube by pushing the handle release button (3). A stiff wire or stick can be used to push the clog out of the tube.
3
4
7
57
Figure 20
Clogs in the Hose - Figures 21, 22 & 23
Check for suction at the end of the hose (19). If you feel reduced suction, the blockage is in the hose. To clear blockages in the hose (13), remove the telescopic tube (4) by pushing the tool release button (7) and pulling the tube out. Hold the hose upright with one hand blocking the top and switch on the machine. If necessary, quickly lift your hand on and off the end of the hose. If that does not clear the clog, you may also clear clogs by reversing the hose. K3: After removing the telescopic tube, push the release button (18) on the hose neck (6) and remove the hose from the machine. K2: After removing the telescopic tube, squeeze the tabs (37) on the retaining ring and pull the hose neck out.
Remove the hose handle (1) from the telescopic tube by pressing the handle release button (2). Insert the handle end of the hose (1) into the suction opening (17). Hold the hose upright with one hand blocking the top and switch on the machine. If necessary, quickly lift your hand on and off the end of the hose.
Note: Do not insert a wire or stick into the hose. Doing so may cause damage to the hose.
Clogs in Entrance to Filter Bag - Figure 21
Remove hose (10) from vacuum cleaner (see figure 21), open the filter bag cover and remove the filter bag. (figure 16, page 9). Clean out entrance to bag (58).
K3
37
19
37
37
K2
1
13
19
18
Figure 21
1
2
13
17
Figure 22
Figure 23
12
58
Figure 24
TROUBLE-SHOOTING GUIDE
Always unplug vacuum from outlet before dismantling any part of the machine!
!
PROBLEM
Does not turn on
Bag full or clog light on Bag full or clog light on & machine shuts off
Does not pick up
REASON
1. Telescopic tube not inserted properly.
2. Not plugged into working outlet.
3. Cable worn.
4. K3: The power control slider switch is set to “0” (“off” position).
1. Bag full.
2. Clog in hose, telescopic tube, brush or head, or entrance to filter bag.
3. Micro-hygiene filter dirty.
4. Exhaust filter dirty.
1. Hose/handle assembly not correctly inserted.
SOLUTION
1. See page 7.
2. Use another outlet.
3. Replace cable.
4. K3: Set slider switch to “on” position. See page 9.
1. Replace filter bag. See page 11.
2. See Clog Removal on page 12. K3 users with clog in power head attachment: refer to clog removal in the ET-H or ET-1 owner ’s manual.
3. Replace micro-hygiene filter. See page 11.
4. Replace exhaust filter. See page 11.
1. Reinsert hose/handle assembly making sure that it is lined up properly and is snapped into place. See page 7.
Filter bag door won’t fully close
2. The suction control dial is rotated to no suction setting
3. Filter bag cover not closed.
1. Filter bag cover not fully closed.
2. Bag not inserted properly
3. Micro-hygiene filter not properly inserted.
2. K2: Rotate suction control dial to yellow setting. See page 8.
3. See below.
1. Reinsert bag. Lock the cover
down firmly.
2. Reinsert bag. lock the cover
down firmly.
3. Remove the filter bag cover (26) and
make sure the micro-hygiene filter housing is seated firmly in place (see pg. 11, figure 18).
13
AIRBELT K2 SCHEMATIC AND PARTS LIST
# 9679AM K2 - Midnight Blue # 9696AM K2 - Hunter Green
Canister with Handle/Hose
#9696AM K2 Hunter Green Machine Pos. Part # Description
1
2 3 4 5 6 7
8 9 0
1
1
1 12 13
4
1 15
6
1 17
8
1 19 20 21
2
2 24
5
2 26
7
2 28 29 30 31 32 33 34 34 35
36 37 38 39 40 41 42 43 44
45 46
6754DG
6675DG 6 6042WS 6 6 6756DG
6607DG 6 6752DG
6 6621 1 6641ER 6 6638 6631ER 6 6635 6 6679DG 6 6680G1 6625DG 6 6613LG 6 6623UL 6047AM/08 6048DG 6627DG 1092DG 6300DG
A
6303DG 6657AM
6271DG 7260DG 0105 6421DG 6420DG 6694DG 6612DG 1329DG 6751DG
6780ER 7200DG
014
681HG 696AM
629AM
652
739
637
634
636
622DG
427K2
086HG
Bottom casing, complete
incl. castors 6751DG)
( Suction neck
eal
S Spring lock
ag holder, complete
B
Microfilter & Exhaust set
K Bag cover, complete
incl. castor 6752DG)
( Cover release
ilter bag SEBO K
F Castor cpl. (New castor for
ag cover 6756DG)
b
able rewind
C Switch lever
eaf spring
L Electronic controller K2 w/switch
nternal cable - black
I Internal cable - white Vac motor, 120V
an ring
F Seal
otor mounting
M Motor cover
lug surround
P Top casing K2 - hunter green Release button
xhaust filter cover - hunter green
E On/Off knob - gray/hunter green
asing clip
C Foam bumper AIRBELT textile-citrus (incl. pos. 31) AIRBELT clip Upholstery nozzle Crevice nozzle Handle grip K2, cpl. (incl. pos. 34A) Retaining ring - dark gray Handle & 7 ft. hose with end couplings (incl. pos. 34 + 34A) Telescoping tube K2 - dark gray Combination nozzle Screw 3.9 x 19 Slide button, cpl. Release button Clip for attachments Retaining ring Dusting brush Castor cpl, (New Style for bottom casing 6754DG) Turbo nozzle Premium parquet nozzle
14
Turbo Nozzle
standard with
K2 Hunter Green
45
46
Premium Parquet Nozzle
standard with
K2 Hunter Green
#9679AM K2 Midnight Blue Machine Exceptions
24 6680DB Top Casing, K2 - midnight blue 26 6424AM Exhaust filter cover - midnight blue 27 6613GW On/Off knob - gray/white 30 6047AM/01 AIRBELT textile - dark gray
(incl. pos. 31)
37
Combination Nozzle
standard with
K2 Midnight Blue
AIRBELT K3 SCHEMATIC AND PARTS LIST
#9681AM K3 - Red #9684AM K3 - Volcano #9698AM K3 - Onyx
Canister with Handle/Hose
#9681AM K3 Red Machine Pos. Part # Description
1
2 3 4 5 6 7
8 9
10
1
1
2
1 13
4
1 15
6
1 17 18
9
1 20
1
2 22
4
2 25 26
7
2 28
9
2 30
31 32 33 34 36 37 38 39 40 41 42 43 44
6754DG
6677DG
014
6 6042WS
681HG
6
696AM
6 6756DG
6607DG
629AM
6 6752DG
652
6
621
6 1739
645ER
6 6637
638
6 6631ER 6634
635
6 6636
679DG
6 6622DG
680DR
6 6625DG 6404K3
666GW
6 6086HG
623UL
6 6047AM/01
6048DG 6627DG 1092DG 6349AM 6270DG 7200DG 6421DG 6420DG 1329DG 6694DG 6369DG 0105 6751DG
Bottom casing
incl. castors 6751DG)
( Suction neck
eal
S Spring lock
ag holder, cpl.
B
Microfilter & Exhaust set
K Bag cover, complete
incl. castor 6752DG)
( Cover release
ilter bag SEBO K
F Castor, complete
able rewind
C
witch lever
S Leaf spring
lectronic controller K3 w/switch
E Internal cable - black
nternal cable - white
I Vac motor, 120V Fan ring
eal
S Motor mounting
otor cover
M Plug surround
op casing K - red
T Release button Exhaust filter cover - red
n/Off knob - gray/white
O Casing clip
oam bumper
F AIRBELT textile - dark gray (incl. pos. 31) AIRBELT clip Upholstery nozzle Crevice nozzle Handle with hose K3, complete Telescoping tube K3 Premium parquet nozzle Slide button, complete Release button, complete Dusting Brush Clip for attachments Mains cable - dark gray Screw 3.9 x 19 Castor, complete
37
Premium Parquet Nozzle
standard with
K3 Red, Volcano and Onyx
#9684AM K3 Volcano Machine Exceptions
24 6680SR Top Casing, K3 - volcano 26 6439AM Exhaust filter cover - volcano 27 6613VO On/Off knob - gray/volcano 30 6047AM/03 AIRBELT textile - volcano
#9698AM K3 Onyx Machine Exceptions
24 6680SW Top Casing, K3 - black 26 6622AM Exhaust filter cover - black 30 6047AM/07 AIRBELT textile - silver/black
(incl. pos. 31)
15
SEBO VACUUM CLEANER WARRANTY
Five Years Non-Wear Parts - Five Years Motor - One Year Labor
1. Your authorized SEBO dealer or SEBO will provide the original product purchaser with replacement of Non­Wear Parts which fail due to a material or workman­ship defect for a period of five (5) years from the orig-
nal date of purchase of new product. SEBO America
i will provide a five (5) year warranty on suction motors and brush drive motors.
2. Your authorized SEBO dealer or SEBO will repair (or will cover labor charges associated with repair) a defective SEBO vacuum cleaner at no cost to the original pur­chaser, within one (1) year of original purchase of new product.
3. SEBO America or an authorized SEBO dealer must complete all warranty repairs.
4. To locate an authorized SEBO dealer in your area, or to register a warranty claim in the United States of
America, please visit our website at www.sebo.us.
5. To locate an authorized SEBO dealer in your area, or to register a warranty claim in Canada, please call Floor
Care Equipment, Ltd. at (403) 250-5005.
6. The warranties provided for above apply exclusively to SEBO Vacuum Cleaners which are used residentially. No warranty is provided for SEBO vacuum cleaners used commercially.
7. The Wear Parts excluded from warranty coverage include filter bags, micro-hygiene filters, exhaust
filters, the cable (external cord), the attachment hose, the brush rollers, the front bottom plate, the rear bottom plate, the telescopic tube, the crevice nozzle, the upholstery nozzle, the dusting brush and all of the
ptional attachments. (See “Optional Attachments” on
o page 7 of this manual).
. This warranty applies only while your SEBO Vacuum
8
Cleaner is physically located within the United States of America and its territories or Canada.
9. The purchase receipt showing the date, price, and item of purchase is the initial document of proof of purchase and determines the validity of warranty. To be certain that your warranty claim can be processed as quickly and efficiently as possible, please retain your original purchase receipt and mail in the warranty card provided with your new SEBO vacuum cleaner. You may also reg­ister on our website at www.sebo.us.
10. This warranty gives you specific legal rights. You may also have other legal rights, which vary from state/province to state/province.
11. SEBO America will not process nor will it accept responsibility for warranty claims for machines pur­chased from dealers located in Canada. Floor Care Equipment, Ltd. will not process nor will it accept responsibility for warranty claims for machines pur­chased from dealers located in the United States.
EXCLUSIVE REMEDY: The remedies provided under the terms of this Warranty are the purchaser’s exclusive remedies
and are in lieu of any other remedies otherwise available.
THE WARRANTY DOES NOT COVER:
• Used or secondhand products.
• Products outside of the warranty period.
• Items not manufactured by SEBO.
• Normal maintenance service.
• Equipment damaged by improper use, accident, other casualty or negligence.
• Machines equipped with nonauthorized attachments or modifications.
• Machines on which the serial number has been altered or removed.
To contact SEBO in the United States of America:
SEBO America, LLC Telephone: (303) 792-9181 Fax: (303) 792-9196 Website: www.sebo.us
LIMITATIONS AND EXCLUSIONS:
SEBO MAKES NO OTHER REPRESENTATIONS OR WARRANTIES, EXPRESSED OR IMPLIED AND SPECIFICALLY EXCLUDES THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
SEBO WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUEN­TIAL DAMAGES OF ANY KIND OR NATURE.
THIS DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO THE EXTENT SAID DISCLAIMER IS NOT ALLOWED BY APPLICABLE STATE/PROVINCIAL LAW.
To contact SEBO in Canada:
Floor Care Equipment, Ltd. Telephone: (403) 250-5005 Fax: (403) 250-5057 Website: www.sebocanada.ca
16
© Copyright SEBO America, LLC • All rights reserved.
Loading...