S
Optional Power Heads for the AIRBELT K36
Optional Attachments, Accessories, Bags and Filters6
Identification of Parts7
Assembly7
Standard Attachments7
Optional Attachments7
Operating Instructions8
Starting the Machine8
Suction Control8
Operating the Machine8
Additional Operating Instructions for K3 with Power Head9
Starting the Machine and Suction Control9
Operating the Machine9
Using the Telescopic Tube, Hose & Attachments10
Use and Maintenance of Brushes and Heads10
The Parquet Nozzle10
The Combination Nozzle10
The Turbo Nozzle10
Vacuum Maintenance11
Changing the Filter Bag11
Changing the Micro-Hygiene Filter11
Changing the Exhaust Filter11
Changing the AIRBELT11
Clog Removal12
Clogs in the Head or Brush12
Clogs in the Telescopic Tube12
Clogs in the Hose12
Clogs in Entrance to Filter Bag12
Trouble-Shooting Guide13
AIRBELT K2 Schematic and Part Numbers14
AIRBELT K3 Schematic and Part Numbers15
Warranty16
How To Contact SEBO16
TECHNICAL DETAILS
Vacuum motor1250 watts (10.6 amps)
Water lift (at motor)110 inches
Airflow (at motor)120 CFM
Filter bag capacity.8 gallons
Sound level63 dBA
Body weight12 lbs
Motor protectionthermal cut-out
Cord length20 feet
Range31 feet
Technical details may be subject to change.
2
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE
!
When using an electrical appliance, basic precautions must always be followed.
To reduce the risk of electric shock, this vacuum cleaner has a polarized plug; one blade is wider than
the other. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any
way. Connect only to the outlet type specified on the serial number plate underneath the machine.
SAVE THESE INSTRUCTIONS.
WARNING: To reduce the risk of fire, electric shock, or injury:
1. Do not leave vacuum while plugged in. Unplug from
outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not use near small children or pets. Do not allow to be
used as a toy. Use of this product by children should
always be supervised by an adult.
4. Use only as described in this manual. Use only
manufacturer-recommended attachments.
5. Do not use with a damaged cord or plug. If vacuum is not
working as it should, has been dropped, damaged, left
outdoors, or dropped into water, take it to a SEBO service
center.
6. Do not pull or carry by cord, use cord as a handle, close a
door on cord, or pull cord around sharp edges or corners.
Do not run vacuum over cord. Keep cord away from heated
surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the
plug – not the cord.
20. Machines can cause a fire when operated near flammable
vapors or materials. Do not operate this vacuum near
flammable fluids, dust or vapors.
21. Maintenance and repairs must be done by qualified
personnel.
22. Use only original SEBO replacement parts.
23. Do not use vacuum as a step.
24. If vacuum is used on plush carpet or carpet with thick
padding, do not leave machine standing in one place with
machine turned on.
25. While the vacuum is in use, the power cord should be
unwound from the cable reel at least two thirds of its length.
Hold plug when rewinding onto the cord reel. Do not allow
plug to whip while rewinding.
26. Keep hair, loose clothing, fingers, and all parts of body away
from vacuum openings and moving parts. Do not place
fingers or other body parts under vacuum unless it is
unplugged.
8. Do not plug in if switch is in the “I” (ON) position.
9. Do not use outlets above counters to plug in vacuum –
damage to items in the surrounding area could occur.
10. Always carry the vacuum over steps and sills.
11. Do not handle plug or vacuum handle with wet hands.
12. Do not put any object into vacuum openings. Do not use
machine with any openings blocked. Keep openings free
of lint, hair, and anything that may reduce air flow.
13. Do not re-use filter bags or wash the filters.
14. Do not remove any screws from vacuum.
15. Do not vacuum up anything that is burning or smoking,
such as cigarettes, matches, or hot ashes.
16. Do not use vacuum without filter bag and/or filters in place.
17. Turn off all machine controls before unplugging.
18. Use extra care when cleaning on stairs.
19. Do not use machine to vacuum up flammable or
combustible liquids such as gasoline or use in areas
where they may be present.
27. Do not place the power head over rug or carpet edges.
28. The vacuum has a manual reset thermal protector. The
protector is reset by switching off the vacuum. The thermal
protector needs some time to cool down after switching off!
Check the vacuum for air blockages or mechanical failures
before switching on.
29. Store the vacuum in a dry place at room temperature. When
the vacuum is not in use, you should rewind the cord onto
the cord reel
30. Any other servicing should be performed by an authorized
service representative.
31. The hose contains electrical wires. Do not use if damaged,
cut, or punctured. Avoid picking up sharp objects.
32. Always unplug vacuum before connecting or disconnecting
either hose or power head.
33. Use a SEBO power head only in combination with a SEBO
vacuum cleaner.
34. Do not connect power head to a malfunctioning or damaged
vacuum.
3
SEBO AIRBELT K PRODUCT FEATURES
SEBO Vacuums Save Money! – SEBO vacuums are the highest
quality machines available. In fact, if properly maintained, SEBO
vacuums can save ordinary residential users hundreds of dol-
ars by providing excellent performance for ten to fifteen years
l
or more. Typical vacuums perform poorly and usually do not last
beyond two years. So, in the long run, SEBO vacuums cost less
money than the five to six other vacuums purchased during that
time period.
Outstanding Warranty Coverage – SEBO is confident about the quality of all its vacuums.
Therefore, all models include a five-year warranty on the motor and all non-wear parts and
a 1-year warranty on labor charges.
Brush Obstruction Light & Auto Shut Off – A
warning light will quickly flash, the brush
roller will immediately stop spinning and the
vacuum will shut off, if an obstruction
becomes jammed in the brush roller.
user should turn the power switch off, unplug
the machine, and immediately remove the
obstruction. If the user restarts the machine
without removing the obstruction, the power head will again
shut off and the amber light will turn on.
from breaking and protects the motor from damage.
Bag Full or Clog Light & Auto Shut Off – A
warning light will illuminate and the
machine will automatically shut off, when it
senses a full bag, a clog in the airflow pathway, or an excessively dirty micro filter.
vacuum’s airflow pathway becomes restricted
due to a full bag or the existence of a clog, the
amber “BAG FULL OR CLOG” light (located on top of the canister
near the ON/OFF power control knob) will illuminate. If the user
ignores this warning, the suction motor will heat up due to the lack
of cooling provided by the airflow. Once the motor reaches a certain
temperature it will shut off to protect itself from damage. The user
should turn the switch off, unplug the machine and immediately
insert a new bag or remove the clog (to remove a clog, refer to the
Clog Removal section on page 12). After approximately 30 minutes,
the motor will have cooled and the vacuum can be restarted. If the
airflow is still restricted, the “BAG FULL OR CLOG” light will again
illuminate and the machine will shut off.
damage to the motor due to overheating.
The
This prevents the belt
If the
This feature prevents
air belt disperses the filtered exhaust air around the canister
which provides quiet, gentle air flow. SEBO’s unwavering attention
to the complete sealing of the machine ensures no dirt escapes
around the microfilters.
Liberation from Bagless! SEBO Bags are
Hygienic – The three-layer filter bag is an
integral part of SEBO’s filtration system
because it effectively contains nearly all dirt
captured by the vacuum. And SEBO bags
can be sealed when full, so no dust can
escape into the air during disposal. In contrast, a lot of dust becomes airborne when emptying the dirt
containers of bagless vacuums, and their micro filters quickly
clog and must be replaced often, or a loss of suction will occur.
And bagless vacuum micro filters are expensive, usually costing much more than SEBO’s filter bags.
Micro Filters are Inexpensive and Easy to Change – Unlike
most other vacuums, SEBO’s replacement micro filters are
reasonably priced and can be easily changed in seconds, without any tools. And the micro filters last a long time before
replacements are necessary because nearly all dust particles
and debris are first captured by the three-layer filter bags.
Remarkably Quiet Operation – A
SEBO vacuum is so quiet, it will
not scare pets, and the feature
will be appreciated by family
members.
SEBO three-step filtration system
c
a
IncorrectHeightSettingorBrush
Deterioration Light – To ensure optimum
cleaning at all times, a warning light will illuminate to indicate when the brush height is
set too high for effective cleaning, or when
the brush roller should be replaced due to
excessive wear.
Anti-allergy Hospital-grade, S-class Filtration –
An excellent choice for users with allergies or
asthma.
in Europe, the AIRBELT K vacuums provide the
user with S-Class filtration of 99.9% of particles to
0.3 microns. This is accomplished by the SEBO three-step filtration
system. First, the three-layer full-size filter bag (a) collects the vast
majority of the debris. Then, the remainder of the particles are collected by the hospital-grade microfilter (b). Finally, the microexhaust filter (c) cleans the exhaust air that the vacuum emits. The
4
Certified by leading Allergy foundations
b
d
S
u
p
e
r
q
u
i
e
t
a
i
r
e
s
u
a
x
h
a
l
l
a
t
!
d
n
u
o
r
SEBO AIRBELT K PRODUCT FEATURES
Designed for All Floor Surfaces.
AIRBELT K3: Five Power Head Choices –
The AIRBELT K3 has an electrified telescopic tube designed to accommodate any
choice from the following five power heads:
ET-1, ET-2, ET-H and DISCO. Each power
head has unique features and benefits, but
all power brushes are designed to provide
thorough brushing for optimal cleaning of
arpets. The DISCO power head enables the vacuum to polish
c
ard floors.
h
AIRBELT K3: Cleaning Dimensions – The ET-1 power head is
12-inches wide, with a cleaning with of 10
ET-2 is 14
ET-C power head is 14-inches wide, with a 12
width, and the ET-H is 11
3
⁄4-inches wide, with a 13-inch cleaning width. The
3
⁄4-inches wide, with an 111⁄2-inch
cleaning width. The DISCO is 13-inches wide, with an 11
K3 with DISCO
1
⁄2-inches, and the
1
⁄2-inch cleaning
3
⁄4-inch
polishing width.
Both Carpet and Hard Floor Cleaning – With a power brush to
clean carpets and a parquet nozzle to clean hard floors, the
AIRBELT K3 provides all the flexibility needed to care for a variety of floor surfaces. The parquet nozzle comes standard. The
K3 vacuum can morph into a hard floor polisher, by adding a
SEBO DISCO head.
Four-level Manual Brush Height Adjustment – The brush
height can be adjusted up or down for optimum cleaning.
Quick-release Connections – The AIRBELT K models allow for
quick and convenient connection of telescopic tubes, power
brush heads, accessory cleaning heads and on-board tools.
Shock Absorber Provides Furniture and
Wall Protection – The “AIRBELT” bumper
hat surrounds the K canisters acts as a
t
protective barrier. The soft foam bumper
with its durable covering protects furniture,
walls and the vacuum itself from damage
during use.
ersonalized Vacuums – AIRBELT canister vacuums can be
P
personalized with a replacement AIRBELT bumper cover available in eight patterns and colors.
Powerful Vacuum Motors Provide Excellent Cleaning – The
canister suction motor is 1,250 watts, and the power head
motor is 175 watts (ET-1), for a total of 1,425 watts.
Comfortable Ergonomic Handle – The AIRBELT handles
are ergonomically designed and positioned to reduce wrist and
arm fatigue. For extra comfort, an additional swivel is built into
the handle-to-hose connection.
High-quality Telescopic Tube and Hose – On the K3, the power
cord is built inside the telescopic tube and suction hose. This
eliminates unsightly external wires and enables unobstructed
and convenient handle height adjustment.
Variable Power Control on Handle – The
vacuum’s suction power can be adjusted
from 0 to 1,250 watts by a slider switch conveniently located on the handle.
Mid-sized Canister Vacuum – The SEBO
AIRBELT K3 and K2 are considered midsize canister vacuums, which means they are machines medium in size that offer mid-sized, on-board attachments and a
mid-sized filter bag with a dirt capacity of .8 gallons. The K
machines also weigh four-pounds less than the C machines.
Three On-board Tools – The vacuum comes standard with a
crevice tool, dusting brush and upholstery nozzle. The dusting
brush is mounted on the telescopic tube, and the crevice and
upholstery nozzles are on the canister. Many optional accessories are also available.
Dusting Brush
Crevice Nozzle
Upholstery Nozzle
Rubber Coated Wheels and High Quality
Castors – The quality of the wheels and
castors on SEBO canisters prevent damage
to floors and rotate 360
0
for easy maneu-
verability.
Large Operating Range – A 31-foot operating range saves time because it minimizes the number of electrical outlets needed during use.
AIRBELT K2: The SEBO AIRBELT K2 is a straight-suction vacuum. As a result, it differs from the AIRBELT K3 in the following
two ways:
Can Not Use a Power Brush – The AIRBELT K2 does not have
an electrified telescopic tube and hose; therefore, it does not
accommodate an electrified power brush. Instead, it comes
standard with a Turbo
Nozzle (an air-driven
brush head) for cleaning rugs and carpet. It
also comes standard
with a Parquet Nozzle
for cleaning hard floors.
Turbo Nozzle
Parquet Nozzle
Variable Power Control
on Canister Body – Because the AIRBELT K2 does not have an
electrified hose and handle, its variable
power control switch is located on the canister body, not the handle.
Brushless Cleaning Capability – The ET-1 or ET-2 power heads
can provide gentle, brushless cleaning of delicate rugs or hard
floors because the brush roller may be switched off, but suction will continue.
5
OPTIONAL POWER HEADS FOR THE AIRBELT K3
Deep clean your carpet with a SEBO power head, or polish
your hard floor with a SEBO DISCO Ultra-High-Speed floor
polisher! SEBO power heads and the DISCO polisher are virtually maintenance free, and their electronic overload protection feature extends belt life by automatically shutting off
ower, if a brush roller or polisher pad jams.
p
3
The SEBO ET-H Power Head (11
1
⁄2” cleaning width) – Its patented new
11
⁄4” wide,
design offers dual-edge cleaning and a
manual brush pressure control, for optimal cleaning from one type of flooring to
another. The steering mechanism built
into the swivel neck helps to easily clean
around obstacles. It also has a brush
height and brush wear warning light.
1
The SEBO ET-1 (12” wide, 10
width) and ET-2 Power Heads (14
⁄2” cleaning
3
⁄4” wide,
13” cleaning width) – These power heads
deliver cleaning flexibility because their
brush action aggressively cleans carpeting, and the brush may be switched off to
clean hard floors and delicate rugs. The
steering ability of the swivel necks help to
easily clean around obstacles, and their Lshaped heads provide maneuverability
around furniture and under cabinets. They
also have brush height and brush wear
warning lights.
The SEBO DISCO (13” wide, 11
ever been easier to make hard floors shine! The SEBO
n
DISCO floor polisher can both vacuum
and polish, for a super-gloss finish. It
can be attached to the FELIX uprights or
to the AIRBELT C or K canisters. Its suction removes fine dust (dust from fully
dried floor polishing product) during pol-
shing, and the 2,000 rpm disc speed will
i
create a high-gloss shine for a fantastic hard floor finish.
Additional DISCO features include automatic height adjustment, automatic safety shut-off caused by blockages or
other reasons, a soft bumper to protect walls and furniture,
a highly maneuverable swivel neck, and three rubber coated castors to protect the floor.
3
⁄4” polishing width) – It’s
OPTIONAL ATTACHMENTS, ACCESSORIES, BAGS & FILTERS
In addition to the standard on-board tools, a variety of
optional attachments are available. The nine-foot extension
hose (extends suction hoses) and the 19-inch extension
tube are very popular because they create useful tools for
cleaning stairs and out-of-reach areas. These two items are
sold separately or as part of multiple item attachment kits.
Another popular attachment is the hand held turbo brush
for removing pet hair from upholstery.
SEBO FRESH
K Filter BagsExtension TubeNine-foot Extension Hose Hand-held Turbo BrushRadiator BrushK Service Box
6
SEBO filter bags can be purchased in boxes of eight and filters are sold separately. Also, bags and filters can be purchased together in model-specific kits called “Service
Boxes.” SEBO bags, filters and accessories are reasonably
priced and widely available.
To create a fresh scent while vacuuming, “SEBO FRESH” is
available. To use, deposit a scented stick in the filter bag.
IDENTIFICATION OF PARTS
. Handle grip
1
2. Power control slider (K3 only)
3. Handle release button
4. Telescopic tube
5. Slide button
. Power cable
6
7. Tool release button
8. Combination nozzle
9. On/Off power control knob
10. Warning light
11. Upholstery Nozzle
12. Mains cable (K3 only)
13. Hose
4. Exhaust filter cover
1
15. AIRBELT shock absorber
16. Carrying handle
17. Suction opening
18. Hose release button (K3 only)
9. Hose neck
1
20. Crevice nozzle
21. Parking attachment holder
22. Power cable shroud
23. AIRBELT clip
24. Parking attachment holder
25. Filter bag cover release catch
26. Filter bag cover
1
2
2
1
3
3
1
4
5
6
10
9
11
Standard Attachments
27
28
32
35a
33
29
20
11
35b
20. Crevice nozzle
11. Upholstery nozzle
31
30
34
36
27. Dusting brush clip
28. Dusting brush
Brushes, Heads, Optional Attachments
29. Premium Parquet nozzle - standard for the
K3 Volcano, Red and Onyx. Optional for the
K2 Midnight Blue - Part #7200DG
30. Combination nozzle - standard for the
K2 Midnight Blue. Optional for the K3
Volcano, Red & Onyx and K2 Hunter
Green - Part #7260DG
31. Turbo nozzle - standard for the K2 Hunter
Green. Optional for the K3 Volcano, Red &
Onyx and K2 Midnight Blue Part #6780ER
32. Radiator brush - Part #1496HG
33. Straight tube (20 in.) - Part #1084HG
34. AIRBELT - Available in several colors
and patterns - Part #6047AM/01-08
17
26
14
19
18
25
7
8
15
16
24
15
20
21 22
23
Power Heads - optional for the K3: 35a. ET-1 Power head - Red: Part #9299AM; Orange: Part #9272AM; Onyx: Part #9951AM
35b. ET-2 Power head - Red: Part #9250AM36. ET-H Power head - Red: Part #9257AM
ASSEMBLY
Push the neck (19) of the hose (13) into the suction opening of the canister (17). K3: The notch in the
suction opening will line up with the raised bar on the neck. When the notches are lined up correctly, the neck will snap firmly into place. To release the hose from the suction opening, press the
release tab (18) on the neck of the hose (19), and pull the neck out. K2: To release the hose from
the suction opening, squeeze the tabs (37) on the retaining ring and pull the neck out.
Attach the short mains cable (12 - K3 only) on the underside of the handle by connecting one
cable plug where the hose connects to the handle and the other where the handle connects to
the telescopic tube.
Connect the handle (1) to the top of the telescopic tube (4). Snap in place. To release the telescopic tube (4) from the handle, push the handle release button (3) and slide the handle out.
Attach the head or brush to the bottom of the telescopic tube (4). Insert the bottom of the telescopic
tube into the neck of the head or brush (38) until it locks into place; or line up the square hole in the
telescopic tube with the notches in the front of the neck, and snap firmly into place. To release a head
or brush from the telescopic tube (4), push the release button (7), and pull the head or brush tool off
the end of the telescopic tool. The release button (7) is in the same position on all of the heads, brushes and power heads.
To attach the dusting brush clip (27), locate the two raised ridges on the upper end of the telescopic
tube (4) just below the handle. Push the clip onto the tube directly below the ridges then slide the clip
up until it locks onto the ridges. Snap the dusting brush (28) into the holder.
NOTE: To attach a SEBO power head (ET-H, ET-1 or ET-2) to your K3 canister, please refer to your
power head owner’s manual for instructions. Attaching incorrectly could cause damage.
NOTE: All illustrations shown in this manual represent the K3 model except where part numbers and instructions are different for each model.
K2
37
K3
19
17
3
4
7
17
19
18
1
4
38
7
OPERATING INSTRUCTIONS ALL K VACUUMS
Starting The Machine
Before turning on your canister, make sure that you have a firm hold on the handle grip to keep the
machine from moving forward.
1. With the canister main power control knob (9) in the OFF position, grasp the plug and pull the
power cord (6) out from the power cable recess (22). The power cord (6) should be unwound
from the cable reel at least two thirds of its length. Note: do not over-extend the cord.
2. Plug the polarized power cord into a 120 volt wall outlet located near the floor.
3. Press the main power control knob on the base of the canister (9) gently with your foot or
hand. The green light (10) will illuminate indicating that the power is on (K3 model only).
Suction Control
K2 users: the suction control dial is located on the top side of the canister on the power control knob
(9). Rotate the dial counter-clockwise for maximum suction. Rotate clockwise to reduce suction for
vacuuming curtains or delicate fabrics.
K3 users: for information on suction control, refer to page 9 of this manual.
- Figure 3
Operating the Machine
Adjust the telescopic tube (4) to the correct height by pushing the slide button (5) and gently pulling the tube out to lengthen, or pushing it in to shorten. Release the slide button
(5) to lock the tube to the adjusted height.
- Figures 1, 2 & 3
- Figures 4, 5, 6 & 7
9
22
6
Figure 1
10
9
Figure 2 - K3
When changing heads, always switch the vacuum off with the power control knob (9), and
then unplug the power cord.
The “bag full or clog” light (#10, figure 2) works correctly only at full power. At lower power
levels, the “bag full or clog” light may illuminate incorrectly. Check the status of the filter
bag regularly at full power. If the light remains illuminated at full power, and the filter bag
is not full, check for clogs (see page 12).
To retract the cord, switch the vacuum off, unplug it from the outlet, then gently pull on
the cord near the plug recess (22) and the mechanism will automatically rewind. Before
rewinding the cable, always switch off and unplug the vacuum. Hold the plug while
rewinding the cord onto the cord reel. Avoid letting the plug whip while rewinding.
The vacuum can be stored with the canister in a horizontal or vertical position. The Parquet nozzle,
Combination nozzle and Turbo nozzle have a parking
tab located on the front of the neck (39). Insert the
parking tab into the upper side of the parking groove
and slide down firmly. For vertical storage, or for easy
carrying, use the parking slot on the underside (24). For
horizontal storage, use the parking slot on the end of
the canister (21).
39
Figure 3 - K2
5
4
Figure 4
21
24
Figure 5
!
WARNING!The quality, condition, coating, texture, age and manufacturing technique of all floor surfaces vary.
Therefore, vacuums with rotating brushes, including your SEBO, may damage some floor coverings or surfaces. Some types
of high-gloss hardwood floors, cushion vinyl, berber carpets, long shag, and delicate or hand-woven carpets are particularly vulnerable to damage by rotating brushes. When possible, consult the materials supplied by your flooring manufacturer for information on proper upkeep and cleaning. To ensure that your new SEBO vacuum cleaner is compatible with your floor, please
test the vacuum cleaner on each type of flooring surface in a small inconspicuous area to determine if any damage occurs.
If damage occurs, stop using the vacuum cleaner immediately!
8
Figure 6
Figure 7
ADDITIONAL OPERATING INSTRUCTIONS FOR K3 WITH POWER HEAD
Please refer to your power head owner’s manual for more information
Starting The Machine
and Suction Control - Figures 1, 2, 8, 9,
10a & 10b
Before turning on your canister, make sure that the vacuum handle is in its upright
locked position (figure 8).
1. With the canister main power control knob (9) in the OFF position, and the power
ontrol slider on the handle (#2, figure 9) in the OFF position, pull the power cord
c
out from the base of the canister (figure 1). The power cord should be unwound from
the cable reel at least two thirds of its length. Note: do not over-extend the cord.
2. Plug the polarized power cord into a 120 volt wall outlet located near the floor.
3. Press the main power control knob (9) on the base of the canister gently with your
foot or hand. The green light (10) will illuminate indicating that the power is on
(figure 2).
4. Slide the Power Control Slider (2) to the ON position (the slider will “click” when it
is pushed out of the OFF position). It will then slide freely between 0 suction and
MAX suction. Set the slider to the suction desired. Release the foot pedal (#41,
figure 10a) on the ET-1 or ET-2 power head or, for the ET-H power head, lower the
handle (figure 10b).
Operating The Machine
When the power head is on with the handle in the upright locked position (see
figure 8 above), the brush roller will not spin.
To release the ET-1 or ET-2 power head from the upright locked position, press
down on the foot pedal (#41, figure 10a) and lower the handle into the normal
operating position and push the button on the top of the power head (#40, figure 8) to engage the brush roller. The green light on the power head will illuminate.
To release the ET-H power head from the upright locked position, gently place
your foot on the power head for leverage and lower the handle into the operating position (figure 10b). The brush roller will then start spinning. The amber
indicator light may flicker for a few seconds when you lower the handle - this is
normal.
- Figures 10a & 10b
ON position - Slide the slider down toward
OFF position - Pull the slider up to 0 suc-
40
ET-H power head
ET-1 power head
Figure 8
2
Figure 9
0 = Zero Suction
MAX = Maximum Suction
0 suction till it “clicks” out of position.
tion then continue pulling the slider up
until it “clicks” into the OFF position.
The handle can be lowered to a horizontal position useful for vacuuming under
beds.
You may adjust the suction control with the power control slider (2) as you vacuum different surfaces or when using the accessory tools. For optimal cleaning
and brushing, operate the machine at the maximum suction power setting and
push the power head slowly over the carpet.
When the canister’s main power control knob is in the ON position, you may turn
the power head off and on with the power control slider (2). To turn the power
head off using the power control slider, pull the slider to 0 suction, then continue pulling the slider up until it “clicks” into the OFF position. The green power
head light will then shut off (the green light on the canister (10) will remain illuminated until the vacuum is powered off using the main power control knob).
Always turn the power off on both the canister and the power head when
changing heads or unplugging the vacuum. Slide the power control slider on
the power head to its OFF position, press the power control knob on the base of
the canister (9) gently with your foot or hand, then unplug the canister to completely shut down the power when changing heads or storing the vacuum.
To retract the cord, switch the vacuum off, unplug it from the outlet, then gently pull on the cord near the plug recess (22) and the mechanism will automatically rewind. Before rewinding the cable, always switch off and unplug the vacuum. Hold the plug while rewinding the cord onto the cord reel. Avoid letting the
plug whip while rewinding.
41
Figure 10a
Figure 10b
9
Using the Telescopic Tube, Hose & Attachments - Figures 11 & 12
The telescopic tube (4) is useful for vacuuming corners and hard-to-reach areas. You may
use the telescopic tube without a brush, power head or attachment. To remove a brush or
power head, switch off the power control knob (9) and unplug the vacuum. Then, press the
tool release button (7) and pull the tube out. The crevice nozzle (20) and dusting brush (28)
may be inserted onto the end of the tube. To use the upholstery nozzle (11), fit it onto the end
f the crevice nozzle (20). It is not necessary to turn off the vacuum while switching the stan-
o
dard attachments (the crevice nozzle, upholstery nozzle or dusting brush). After use, switch
off the power, unplug the vacuum and remove attachment. Re-insert the telescopic tube into
the power head or brush, turning the tube if needed, until you hear it click into place.
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power head
user’s manual for more detailed instructions for connecting your power head.
To use the hose without the telescopic tube, switch off the power and unplug the vacuum.
Push the handle release button (3) and pull the HANDLE out of the end of the telescopic tube.
Do not try to separate the hose from the handle! Insert the crevice nozzle (20) or dusting brush
(28) onto the end of the handle. To use the upholstery nozzle (11), fit it onto the end of the
crevice nozzle (20). After use, switch off the power, unplug the vacuum and remove the
attachment. Re-insert the handle into the telescopic tube making sure it is seated correctly and snap it into place.
11
USE AND MAINTENANCE OF BRUSHES AND HEADS
Figure 11
20
Figure 12
4
7
4
1
20
Always unplug vacuum from outlet before dismantling
!
any part of machine!
To remove a brush or power head, switch off the power and unplug the vacuum. Then,
press the tool release button (7) and pull the tube out.
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power head
user’s manual for more detailed instructions for operating and maintaining your power
head.
Premium Parquet nozzle - Figure 13
The parquet nozzle (29) is specially designed for use on hard surfaces. The brush should be
cleaned regularly. Remove the parquet nozzle from the telescopic tube to clean. Fibers and
hair can be pulled out of the bristles manually, or vacuum the bristles with with the telescopic tube. The brush strips are removable for cleaning and replacement.
Combination nozzle - Figure 14
The Combination nozzle (30) is adjustable for carpet or hard floors. To set for carpet, slide
the up arrow button (42) to the right until it clicks into place. The hard floor dusting brush
will raise up allowing the head to move over the carpet. To set for hard floors, slide the down
arrow button (43) to the left until it clicks into place. The brush will lower to gently sweep
your floors. The slider in Figure 14 is set in the position for hard floors. The brush should
be cleaned regularly. Remove the Combination nozzle from the telescopic tube to clean.
Fibers and hair can be pulled out of the bristles manually, or vacuum the bristles with with
the telescopic tube. The brush strip is removable for cleaning and replacement.
Figure 13
L
L
Figure 14
29
42
30
43
Turbo Nozzle - Figure 15
The Turbo nozzle (31) has an air-driven rotating brush for gentle brushing of carpets. The
Turbo nozzle can be adjusted for high and low pile carpet. To adjust the head for high pile
carpet, push the slider button (44) to the right. For low pile carpet, push the slider button
(44) to the left. The slider in Figure 15 is set in the low pile position. The rotating brush
should be cleaned regularly. Remove the Turbo nozzle from the telescopic tube to clean.
Remove fibers and hair from the brush manually.
10
44
L
Figure 15
31
L
VACUUM MAINTENANCE
lways unplug vacuum from outlet
A
!
before dismantling any part of machine!
Changing the Filter Bag - Figure 16
To change the filter bag (45), set the canister upright (as shown in figure 13),
press the cover release catch (25) and lower the filter bag cover (26). Grasp
the green filter bag sealing plate (46), slide the plate from the holder (48) and
push the filter bag cap (47) on to seal the bag. Slide the sealing plate (46) of
a new bag into the bag holder slots (48) and push it in firmly until it locks into
place. Close the cover, making sure it snaps shut completely. You may find it
convenient to store the bag cap inside the filter bag housing below the filter
bag. Do not re-use the filter bags. Note: the nature of the contents of the filter bag will affect the point at which it needs changing. Fine dust may require
an earlier change even though the bag is not full. Fluff or hair allows air to
pass through easily, so the filter bag may overfill before the amber “bag full”
light illuminates.
The “bag full or clog” light works correctly only at full power. At lower power
levels, the “bag full or clog” light may illuminate incorrectly. Check the status
of the filter bag regularly at full power.
Changing the Exhaust Filter - Figure 17
The exhaust filter (51) needs to be changed when it becomes extremely dirty
or clogged with dust, or after approximately 10 to 20 filter bags have been
used. To change the exhaust filter, set the canister flat on the floor as shown
in figure 17. Remove the printed cover on top of the machine (14) by lifting the
catch (49) in the upholstery nozzle recess (see inset, figure 17). Pull out the
filter using the handle (50) and fit the new filter into the same position. The
filter handle should point toward the upholstery nozzle when it is folded
down. Fit the tabs on the bottom of the cover (14) into the grooves and snap
the cover down firmly.
Changing the Micro-Hygiene Filter - Figures 16 &18
After 10 to 20 bags have been used, change the micro-hygiene filter (52). To
remove the micro-hygiene filter, set the canister upright (as shown in figure
16). Press the cover release catch (25) and lower the filter bag cover (26).
Remove the filter bag, then remove the cover by sliding it up and out of the
grooves (53). Pull the old filter out (52) and slide the new filter into the same
position. Replace the filter bag, then re-insert the cover by fitting the tabs
into the grooves (53) on both sides and sliding it in and down. Push the cover
closed, making sure it snaps shut completely.
26
Filter Bags
Part #6629AM
49
14
51
K Filter Set:
Exhaust Filter
and
Micro-Hygiene
Filter
Part #6696AM
25
45
26
47
46
48
45
26
25
Figure 16
50
51
Figure 17
5353
K Service Box - 8 Filter Bags, Exhaust Filter and
Micro-Hygiene Filter Part #6695AM
52
Changing the AIRBELT - Figure 19
If damage occurs to the AIRBELT cover, it will need to be replaced. To remove
the AIRBELT (15), pry off the clip (55) by inserting the tip of a slot-head screwdriver under the bottom side of the clip. Push downward on the screwdriver
until the clip pops off. Grasp the end of the AIRBELT cover and pull - the AIRBELT cover will peel off. The foam bumper (54) remains on the vacuum. To
replace the AIRBELT, insert the side ribs of the AIRBELT into the grooves (56).
Start at the back, insert rib into one groove (56), and while holding it down,
stretch the AIRBELT cover around the foam (54) into the opposite groove (56).
Continue around the vacuum. Secure the ends with the clip (55).
SEBO AIRBELT covers are available in a variety of colors and patterns. See
your SEBO dealer for available selection.
Note: Never operate the vacuum with incorrectly attached filters or without filters, bag,
AIRBELT or filter bag housing cover (26). Do not re-use filter bags. Do not wash and re-use filters.
AIRBELT Cover - Part #6047AM/01-08
52
Figure 18
54
15
55
56
54
56
Figure 19
11
CLOG REMOVAL
!
NOTE! K3 users with ET-H, ET-1 or ET-2 power heads, please refer to your power
head user’s manual for more detailed instructions for removing clogs in your power
head.
f the “bag full or clog” warning light (10) remains illuminated after the filter bag
I
has been changed and the filters are in good condition, there is likely a clog in the
system.
Always unplug vacuum from outlet before removing
any clogs!
Clogs in the Head or Brush - Figure 20
Clogs in the swivel neck (57) of a head or brush can be cleared by first pressing the
tool release button (7) and removing the brush or head. Check inside the swivel neck
channel (56), and clean out pathway.
Clogs in the Telescopic Tube - Figure 20
Remove head from telescopic tube (4) by pushing the tool release button (7) and
pulling the tube out. Remove the hose from the top of the telescopic tube by pushing
the handle release button (3). A stiff wire or stick can be used to push the clog out of
the tube.
3
4
7
57
Figure 20
Clogs in the Hose - Figures 21, 22 & 23
Check for suction at the end of the hose (19). If you feel reduced suction, the blockage
is in the hose. To clear blockages in the hose (13), remove the telescopic tube (4) by
pushing the tool release button (7) and pulling the tube out. Hold the hose upright with
one hand blocking the top and switch on the machine. If necessary, quickly lift your
hand on and off the end of the hose. If that does not clear the clog, you may also clear
clogs by reversing the hose. K3: After removing the telescopic tube, push the release
button (18) on the hose neck (6) and remove the hose from the machine.
K2: After removing the telescopic tube, squeeze the tabs (37) on the retaining ring and
pull the hose neck out.
Remove the hose handle (1) from the telescopic tube by pressing the handle release
button (2). Insert the handle end of the hose (1) into the suction opening (17). Hold the
hose upright with one hand blocking the top and switch on the machine. If necessary,
quickly lift your hand on and off the end of the hose.
Note: Do not insert a wire or stick into the hose. Doing so may cause damage to the
hose.
Clogs in Entrance to Filter Bag - Figure 21
Remove hose (10) from vacuum cleaner (see figure 21), open the filter bag cover and
remove the filter bag. (figure 16, page 9). Clean out entrance to bag (58).
K3
37
19
37
37
K2
1
13
19
18
Figure 21
1
2
13
17
Figure 22
Figure 23
12
58
Figure 24
TROUBLE-SHOOTING GUIDE
Always unplug vacuum from outlet before dismantling any part of the machine!
!
PROBLEM
Does not turn on
Bag full or clog light on
Bag full or clog light on
& machine shuts off
Does not pick up
REASON
1. Telescopic tube not inserted properly.
2. Not plugged into working outlet.
3. Cable worn.
4. K3: The power control slider
switch is set to “0” (“off” position).
1. Bag full.
2. Clog in hose, telescopic tube,
brush or head, or entrance to
filter bag.
3. Micro-hygiene filter dirty.
4. Exhaust filter dirty.
1. Hose/handle assembly not
correctly inserted.
SOLUTION
1. See page 7.
2. Use another outlet.
3. Replace cable.
4. K3: Set slider switch to “on”
position. See page 9.
1. Replace filter bag. See page 11.
2. See Clog Removal on page 12.
K3 users with clog in power head
attachment: refer to clog removal
in the ET-H or ET-1 owner ’s
manual.
3. Replace micro-hygiene filter.
See page 11.
4. Replace exhaust filter. See page 11.
1. Reinsert hose/handle assembly
making sure that it is lined up
properly and is snapped into
place. See page 7.
Filter bag door won’t
fully close
2. The suction control dial is rotated
to no suction setting
3. Filter bag cover not closed.
1. Filter bag cover not fully closed.
2. Bag not inserted properly
3. Micro-hygiene filter not properly
inserted.
2. K2: Rotate suction control
dial to yellow setting. See page 8.
3. See below.
1. Reinsert bag. Lock the cover
down firmly.
2. Reinsert bag. lock the cover
down firmly.
3. Remove the filter bag cover (26) and
make sure the micro-hygiene filter
housing is seated firmly in place
(see pg. 11, figure 18).
13
AIRBELT K2 SCHEMATIC AND PARTS LIST
# 9679AMK2 - Midnight Blue
# 9696AMK2 - Hunter Green
Canister with Handle/Hose
#9696AM K2 Hunter Green Machine
Pos. Part #Description
24 6680SWTop Casing, K3 - black
26 6622AMExhaust filter cover - black
30 6047AM/07 AIRBELT textile - silver/black
(incl. pos. 31)
15
SEBO VACUUM CLEANER WARRANTY
Five Years Non-Wear Parts - Five Years Motor - One Year Labor
1.Your authorized SEBO dealer or SEBO will provide the
original product purchaser with replacement of NonWear Parts which fail due to a material or workmanship defect for a period of five (5) years from the orig-
nal date of purchase of new product. SEBO America
i
will provide a five (5) year warranty on suction motors
and brush drive motors.
2.Your authorized SEBO dealer or SEBO will repair (or will
cover labor charges associated with repair) a defective
SEBO vacuum cleaner at no cost to the original purchaser, within one (1) year of original purchase of new
product.
3.SEBO America or an authorized SEBO dealer must
complete all warranty repairs.
4.To locate an authorized SEBO dealer in your area, or to
register a warranty claim in the United States of
America, please visit our website at www.sebo.us.
5.To locate an authorized SEBO dealer in your area, or to
register a warranty claim in Canada, please call Floor
Care Equipment, Ltd. at (403) 250-5005.
6.The warranties provided for above apply exclusively to
SEBO Vacuum Cleaners which are used residentially.
No warranty is provided for SEBO vacuum cleaners
used commercially.
7.The Wear Parts excluded from warranty coverage
include filter bags, micro-hygiene filters, exhaust
filters, the cable (external cord), the attachment hose,
the brush rollers, the front bottom plate, the rear
bottom plate, the telescopic tube, the crevice nozzle,
the upholstery nozzle, the dusting brush and all of the
ptional attachments. (See “Optional Attachments” on
o
page 7 of this manual).
.This warranty applies only while your SEBO Vacuum
8
Cleaner is physically located within the United States of
America and its territories or Canada.
9.The purchase receipt showing the date, price, and item
of purchase is the initial document of proof of purchase
and determines the validity of warranty. To be certain
that your warranty claim can be processed as quickly
and efficiently as possible, please retain your original
purchase receipt and mail in the warranty card provided
with your new SEBO vacuum cleaner. You may also register on our website at www.sebo.us.
10. This warranty gives you specific legal rights. You may
also have other legal rights, which vary from
state/province to state/province.
11. SEBO America will not process nor will it accept
responsibility for warranty claims for machines purchased from dealers located in Canada. Floor Care
Equipment, Ltd. will not process nor will it accept
responsibility for warranty claims for machines purchased from dealers located in the United States.
EXCLUSIVE REMEDY: The remedies provided under the terms of this Warranty are the purchaser’s exclusive remedies
and are in lieu of any other remedies otherwise available.
THE WARRANTY DOES NOT COVER:
• Used or secondhand products.
• Products outside of the warranty period.
• Items not manufactured by SEBO.
• Normal maintenance service.
• Equipment damaged by improper use, accident,
other casualty or negligence.
• Machines equipped with nonauthorized
attachments or modifications.
• Machines on which the serial number has been
altered or removed.
SEBO MAKES NO OTHER REPRESENTATIONS OR WARRANTIES,
EXPRESSED OR IMPLIED AND SPECIFICALLY EXCLUDES THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
SEBO WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR NATURE.
THIS DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT
APPLY TO THE EXTENT SAID DISCLAIMER IS NOT ALLOWED BY
APPLICABLE STATE/PROVINCIAL LAW.