Sears EcoWater CWF User Manual

Page 1
ECOWATER SYSTEMS
Countertop Water Filter With Monitor
Model CWF
Installation & Operating Manual
Page 2
ECOWATER PARTS UST:
10 - ADAPTER KIT
TO FAUCET
TODIVERTER
1 Housing
2 Housing O-ring 3 Filter, model RCCWF
4 Faucet 5 Dlverter Gasket (1_o included) 6 Diverter & Tubing Assembly
7 Base Assembly 8 Battery Door (not shown)
9 AAA Batteries Included, not
Installed, 2 necessary (not shown)
10 Adaptor Kit
INTRODUCTION
Thank you for purchasing your new EcoWater Countertop Water Filter with
Monitor, an advanced filtration system combined with state-of-the-art elec-
tronic capacity monitoring.
Your new system was designed to be a convenient, portable, yet highly capable
water filter for today's needs. Its inte- grated meter provides information on
filter life,
Figure1
Pogel
Page 3
ABOUT YOUR SYSTEM
Your new Countertop Water Filter features a combinafion of filtration
technologies to reduce unwanted contaminants In a water supply2
The following technologies are com-
bined in the unique muftFfunotlonal EcoWater RCCWF which reduces lead,
taste and odor to give you clear
sparkling drinking water: First Stage: Mechanical Filtration
A melt blown polypropylene outer sleeve prefilters all water flowing through your system, reducing rust, sediment and
other debris. This prefiltratlon significantly Increases the life of the carbon block,
therefore extending the life of the Filter.
Filter Cutaway
Second Staae: Advanced Carbon Block
The second stage utilizes carbon block technology and a special ATS2Sorbent
Media to reduce taste and odors, chlorine and lead, The activated carbon
block provides high adsorptive capacity and extreme uniformity at an economi-
cal cost. ATSutilizes a proprietary formu- lation to selectively reduce soluble lead from water supplies. Itsspeed and high capacity make it an Ideal media for a single cartridge filter system.
Thank you again for purchasing your
EcoWater Countertop Water Filter. We
hope you will enjoy It as much as we
enjoyed developing if for you,
polypropylene prefllter
water flow Into the filter
I 5_ p_-_'CI Oota _eet _ _fIc cOntamlnanf r_Mor_
2 ATS_ Is a ti_a_ll _ ot tt_ IEngelna_ Co_a_cn.
carbon block
filtered water to the faucet
Figure 2
Page 2
Page 4
PRECAUTIONS:
1. Read the following precautions and Installation instructions completely before beginning InstaUatlon. Please note that this system should be
Installed In accordance with local laws and regulations.
2, This water filter isfor use on COLD
_._, Hot water may damage the system. Maximum temperature Is
100° F(38° C).
3, Protect the water filter and tubing
from freezing temperatures. Failure to do so can cause damage and void
warranty.
4. This system must be installed on
mlcrabloloaicallv safe water.
STARTUP
1, Compare box contents with major
par_s list. [See Figure 1.) Please Note:
The Filter is installed, ready for use.
2. Install the 2 AAA batteries In the bottom of the Filter Base assembly,
Please note how batteries are to be insta{led by looking at diagram
molded into battery compartment, Failure to properly InstaLlbatteries can
seriously damage the system,
3,
Remove the existing faucet aerator by unscrewing, if the faucet aerator Is difficu[t to remove, a pair of pliers with
padded Jaws may work.
(See Figures 3 & 4.)
4,
Remove the protective foam wrap
from the diverter. Please note that there are two gaskets provided with
the dlverter. Use the thick gasket.
Thread the Dlverter Valve onto the faucet "hand-tight* only, (See Figure B.) Do not overtlghten! Overtlghten-
ing can damage the threads. If the dlverter will not thread on properly, use the thin gasket, If the Diverter Valve is not compatible, an Adapter and Gasket Kit is provided to obtain a
proper fit, (See Figure 1.)
B.
To run water through the filter, turn on the COLD WATER faucet and slide the
dlverter mechanism. To stop the flow,
turn off the cold water faucet or slide the diverter mechanism in the oppo-
site direction. [See Figure 6,)
Figure 3 Figure 4
Figure 5 Figure 6
Page 3
Page 5
FLUSHING THEFILTER
On initialstartup oraftera Filterchange, turnthe water on and rinsethe Filterfor5
mlnutesto remove carbon finesand expel excess air.
For best results, after setting over night or after several hours of non-use, turn the
system on and rinse the filter for 15 seconds before using.
You are now ready to enjoy your EcoWater Countertop Water Filter.
NORMAL OPERATION
System performance and reduction of contaminants Isdetermined by proper flow rote. This unit as tested under ANSI/
NSF Standards 53 & 42 must be used at a flow rate no greater than 0.75 gpm.
Exceeding this flow rate will affect the
ability of the system to reduce contami- nant levels.
WATERMETEROPERATION SECTION Your Countertop Water Filter comes with
a digital meter that shows you how much filter fife isleft at any given time. To
preserve battery life the display is only acltvated when you draw water through the tilter or pressthe "Display* button. There are three informational screens that can be viewed by pressing the
display button.
Screen 1: Caoacltv Remalnina This display mode shows the remaining
capacity of your filter in gallons, (see
figure 7), in this case 500 gallons,
The unit of measure is either galtons or liters, depending on the programming at the factory. The water drops at the
bottom of the screen graphically show
how much of the capacity of your filter remains, much like a fuel gauge. By pressing the display button you can move on to the next display mode,
Months Remaining,
DISPLAY /
BUTTON
Figure 7
Page 4
Figure8
Page 6
Screen 2: Months Remainlna
This display mode shows the remaining capacity of your filter In months, In this
case, 6 months. (See figure 8.)
Bypressingthedisplaybuttonyoucon move ontothenextdlsplaymode, FlowRate.
Screen 3: Flow Rate Thisdisplay mode shows you at what
rate water Isflowing through your filter. (See figure 9,) This unit Isdesigned and
tested to operate at 0.75 gpm through the use of an Internal flow restrlctor that
Isdependant upon water pressure.As sllghtvariationsInwater pressuremay
occur,your displaymay flickerbetween
0.7and 0.8gpm.
The drawing shows that water Isflowing through your filter at 0.7 gallons per
minute. (See figure 9.) The water drop scrolls along the gauge at the bottom
as a second Indicator that water Is flowing through your filter and the water
meter isworking properly. Pushing the display button again would return you to
Screen 1-Capacity Remaining.
DISPLAY I
BUTTON
ALARM MODES
Advisory Beep - 50 gallons left
The water meter will alert you with an
advisory beep when there isless than 60 gallons (200 liters) of capacity remain- Ing In your filter. It Is a slnale advisory beep that sounds every 5 seconds when you draw water, and only when you
draw water. We suggest you contact your supplier for a replacement filter as soon as you hear the advisory beep. (See figure 10.)
W_
"
O , ooooooooj0
Figure I0
Alarm Beep -Filtercapacity e_austed
The alarm beep sounds when the capac- it,/of your filter has been exhausted. The
water meter will sound three aulck heeds when water is drawn. The display will
alternate between "CHANGE FILTER 1* and the previous screen viewed. The
display will continue to aflemate until the filter has been changed and the meter has been reset. (See figure 11 .)
Figure 9
Page6
Page 7
beep
beep
bee_
i/_.
Figure 1}
oi"
°I ....1.
CHANGING THEFILTERAND SANITIZING
THE SYSTEM
The EcoWater RCCWF Filter has a rated life of 500 gallons or 6 months, however
in certain water supplies, taste or odors may return or the flow may decrease prior to its rated capaclW, In these cases the Filter should be replaced more often.
To remove the exhausted Filter please refer to the following Instructions'.
I. There wellbe water in the Filter Hous-
ing so be sure to change filters over the sink. Hold the water filter upside down when removing the Filter Housing to reduce spillage. Unscrew the Filter
Housing by holding onto the base assembly and turning the housing clockwise. (See Figure 12,) Discard the used Filter, _ discard the rubber
Housing O-Ring.
2. :111Fitter Housing with warm soapy
water and scrub with a soft brush or sponge. Rinse thoroughly. Do not use abrasive pads or cleaners. Add 2 capfuls
of unscented chlorine bleach to the Filter Housing and fill 2/3 full with cold water.
Do not vet install the reolacement Filter,
3. Leaving the chlorine solution in the Filter Housing screw the Filter Base assembly into the Filter Housing. When
reassembling the Filter Housing to the Filter Base it is Important that the rubber
Housing O-Ring is properly seated in its groove in the Filter Housing or a water
-- 8o,_e
-- HousingC_r_g
--Fitter Housing
J
Figure 12
Page6
Page 8
leak could occur. Place the Housing and Base right side-up with the Faucet
pointing Into the sink, Allow to stand for
1B minutes.
4. After 15 minutes, rinse the chlorine solution from the Housing and Base by tumtng on the COLD WATER faucet and
sliding the dlverter mechanism, The system will be adequately rinsed when no chlorine smell is present, Shut-oft the
cold water.
5. Again, hold the filter upside down, unscrew the Filter Housing by turning . clockwise and empty.
6, Remove the plastic wrap and label from the replacement Filter and place it
In the Filter Housing so that the end with the Cartridge O-Rings is facing outward (toward the base). Make sure that the
Housing O-Ring is In the Filter Housing and screw the Filter Housing onto the Filter Base. (See Figure 12,)
7, Place the Filter System right side-up with the Faucet pointing into the sink.
Rinse the Filter System for 5 minutes to
remove carbon fines and expel excess
air, Be certain to reset the meter after you have comDletelv rinsed the system !!
RESETTINGTHEWATERMETER CAUTION: After changing the filter you
must reset your meter to monitor the life of your new filter. ITISVERY IMPORTANT
TO USETHESAME KIND OF FILTERSTHAT WERESHIPPEDWITH YOUR SYSTEM.THE VALUESTHATARE PROGRAMMED INTO
THEWATERMETERAPPLY ONLY TO THE SYSTEMMANUFACTURER'S FILTER.
TO RESETTHEMETER:
WARNING: Resetting the meter is [E.e_Y_. Please read the following
instructions carefully.
Depress and hold the reset button until "RESET? FILTER 1" appears (2 seconds)
then release the reset button. The
"RESET?" will be flashing. (See Figure 13.)
BUttON
Figure 13
Pressgrid hold the display button for 5
to complete the filter reset, (See
figure 14.) (Notice how the "?" disap-
pears after RESETand it stops flashing).
You will hear a confirming beep when the water meter has been reset. The
Page 7
Page 9
water meter has been reset and has returned to its original programmed capacities (500 gallons, 6 months).
if you do not complete the reset proce- dure successfully, wait for 30 seconds
and try again.
OISPLAY J eMrfON
Figure 14
CHANGING THEBA'rrERIES
Under normal circumstances, the meter batteries should last 1-2 years, However,
if is recommended that the bafferles be replaced every year or when the low
battery indicator appears on the screen ("BAT"). (See Figure 15.)
1. Change the batteries only while the water Isturned off,
2. Turn the system upside down.
3. Open battery door on bottom of Filter Base assembly.
4. Remove both AAA batteries.
5.
Note how batteries are to be installed by looking at diagram molded into battery compartment. Failure to
properly install batteries can seriously damage the system. Replace with new batteries. Use only fresh baffedes.
6,
Close battery door.
7.
PressDisplay to verify correct installa-
tion.
Page 8
Figure 1.5
Page 10
OPERATING PARAMETERS:
Water Pressure(rnln-rnax) 15psi- I(30psl 103 kPa - 690 kPa
Temperature (mln-max) 40°F - 100°F 4°C - 38°C
pH 6,5 - 8,5 6,5 - 8.5 Iron 0 ppm - 0.3 ppm 0 rngL - 0.3 rngL
Manganese 0 ppm - 0.05 ppm 0 mgL - 0,05 mgL Hydrogen Sulfide None None
Turbidity Lessthan 5 NTU Lessthan 5 NTU
Bacteria _ Must be potable Must be potable
PLEASENOTE:
This System contains a replaceable Filter, model number RCCWF, which must be replaced at regular Intervals to maintain proper performance. Useonly factory
approved filters. For parts or service, please contact the outlet where your unit was purchased or contact EeoWater at 1-800-86WATER (1-800-869-2837) or at the address
below.
qhe _CCWF C_rt_Ige does not flite¢ or _JHbocterla _ vl_e_ do not _e thl_ _y3tem wlth water that i_ mlcr o blolOglcally uns_:;fe or with water of unknov_n quality wlthou t adequate _nfectlon before or ati_" the _ystem.
Thls ddnklng water system conforms to ANSI/NSF Std, 53 for Lead and Turbldity reduction and ANSIINSF Std 42 for Chlorine (Class I) and Taste ar_l Odor €eduction as verlfled and substantfate_ by test data, Fo_conditions
of use, health claims certified by the Cotlfornla Department or Health Services, and replacement parts, see
product data sheet. Cartfc_nla Dept. of Health Certlflcate Number 97-1311
Caution: Do net use wlth water that I_microblologlcaily unsafe or of unknown quallt¥ without adequate
disinfection before or offer the system.
EcoWater Systems
PO Box 64420, St. Paul, MN 55164
1-800-869-2837
Page 9
Loading...