Sears 758.144108 Kenmore Operating Instructions Manual

f
READ AND
SAVE THESE
INSTRUCTIONS
SF_AIRS
Stock No.
42-14410
758.144108
FOR YOUFt
READ
ALL RNSTFIUCTIONS
CAREFULLY
QUIETCOMFORT
WHOLE HOUSE
HUMiDiFiER
t0 Gallon Output
, Operating instructions , Parts List
Sears, Roebuck and Co., Hoffman Estates, tL 60179 U.S.A.
Part No. $PG556 Printedin Canada
FULL ONE YEAR WARRANTY ON HUMIDmFmER "_
if within one (1) year from the date of purchase, this humidifier fails due to a defect in
material or workmanship, Sears will repair it, free of charge, if within two (2} years from the date of purchase, the motor fails due to defect in material or workmanship, Sears witl repair it free of charge. This warranty service is available by simply returning the humidifier to the nearest Sears Store, and it will be repaired or replaced, at Sears option, free of charge. This warranty applies only while this product is used in the United States.
This warranty gives you specific _ega/rights, and you may also have other rights which
ry from state to state.
Sears, Roebuck a_tates, tL 60179
GENERAL SAFETY
Safety Signal Words 5. DANGER: means if the safety information is not followed, someone will be seriously 6.
injured or killed. WARNING: means if the safety information is
not followed, someone could be seriously 7. injured or killed.
CAUTION: means if the safety information is 8. not followed, someone may be seriously injured or killed.
1. Toreduce the riskof fire orshock hazard,plug 9. humidifierdirectly intoa 120V,A.C. electrical
outlet. Do notuse extension cords.
2. Keep the electriccord out of traffic areas. To reduce the risk of fire hazard, never put the
electric cord under rugs, near heat regis- ters, radiators, stoves or heaters.
3. Always unplug the humidifier before mov- ing it, before cleaning, or whenever the
humidifier is not in service.
4. Keep the humidifier dean.
iNSTRUCTiONS
Do not put foreign objects inside the humidifier.
Do not allow to be used as a toy. Close
attention is necessary when used by or
near children. Never use your humidifier while any part
is missing or damaged in any manner.
To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip
humidifier while unit is running.
To reduce the risk of damage to humidifier,
unplug humidifier, when the base is empty
or when the humidifier is not in use.
10.To reduce the risk of accidental electrical shock, do not touch the cord or controls
with wet hands.
11.Note the warning !abel shown below.
WARNmNG: To reduce risk of fire, elec=
trie shock, or injury always unptug before fiIHng, servicing or cleaning.
Table of Contents
Warranty Information .................................. 2
General Safety instructions ........................ 2
To Save A Service Call ............................... 2
Know Your Humidifier ................................. 3
Humidifier Operations ................................ 4
Assembly .................................................... 4
Location Instructions .................................. 5
Electrical Hook-Up ...................................... 5
Water Fill .................................................. 6-7
Operating Humidifier Controls ................... 7
Using Your Humidifier ................................. 8
Operating Tips for Best Performance ......... 8
Replacement and Care of Filters ........... 9-10
Cleaning Your Humidifier ..................... 11-12
Troubleshooting ....................................... 13
Repair Parts ......................................... 14-15
To Save a Service Call --
Check the following if your humidifier is 3. Is airflow control in operating position? not operating. 4. Is humidity control set high enough?
1. Is power cord attached to outlet? 5. Is the humdifier sitting on a level sur-
2. Is there electrical power to outlet? face? 2
Know Your Humidifier
Bottle HandRe
_ Speed Control
Description Gallon Output/24 hrs
Capacity of Bottle Capacity of Base
Sq. Ft. Coverage Fan Speeds Replacement Filter Power Light
FHILight Auto Humidistat
42-14410
10
1.9 Gallons
2.0 Gallons 2100
3
42=14906
Yes Yes Yes
Auto Shut Off Controls
CUL Listed Volts Hertz
Amps Watts
Yes
Rotary
Yes
120 A.C.
6O
0.80 8O
Based on an area with average insulation and an 8 foot ceiling height.
Humidifier Operation
Your new Sears humidifier is designed to satisfy home humidity requirements through the principle of evaporation of
water into the air. After water is added to the humidifier, the
filter begins to soak up the water and will become saturated in approximately 30 minutes. Air drawn in through the open-
ings in the lower housing passes through the filter by means of a circulation fan. As air passes through the filter, moisture is
absorbed into the air and then released in the form of vapor. No water droplets
will enter the home. All evaporation into the air takes place in the humidifier,
which means that the residue left by evaporating water is not passed into the
home, but remains in the filter. This natural process of evaporation helps
eliminate the chance of white dust in the humidified output air.
CAUTION: Use only 42-14900 EPA
Registered Baeteriostat available
from SEARS Retait store. Under no circumstances should you use water
treatment products designed for
Rote beretor Ultrasonic humidifiers.
Humidified air is
then released through the top
Dry sir enters
through the
louvers in
the housing
CAUTmON: To reduce the risk of injury_ fire or damage to humidifier,
use only cleaners specifically recom- mended for humidifiers. Never use
flammable, combustible or poisonous materials to s_ean your humidifier. To reduce the risk of saamds and damage
to humidifier, never put hot water in
humidifier.
Assembly
Carefully remove the humidifier and al! other contents from the carton.
There is a black strip that contains six pads for the bottom of the humidifier. Remove each pad and place one on each of the six legs on the bottom of the base as shown, by the solid dots.
Once installed return the humidifier to it's original state and proceed to
"Location Instructions".
3
4
5
Location instrucdons --
WARNING: For your own safety, do not use humidifier if any parts are
damaged or miseing,
Step 1 Place humidifier on a fiat level surface in
an area of house where most humidity is needed, or one which would likely result in moist air being circulated throughout the
house such as near a cold air return. Placing the unit level is very important.
Special attention should be given to unit's level if the humidifier is located on
carpeting.
Moist air (humidity) produced will disperse
into the whole house, but the area closest to the unit will have the highest humidity. If the unit is positioned close to a window, condensation may form on the window
pane. if this is not appropriate the unit
should be repositioned in another location.
NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away
from home thermostat and hot air
registers. It is best to position humidifier
next to an inside wall. Hot air registers and cold air from outside walls can affect the
efficiencies of the controls. Unit should not
be placed where warm air from a hot air
register blows directly on unit.
Step 2
The humidifier should be positioned with the back (cord exit side) and left side, at
least 2 inches away from the wall. Air needs to enter through all of the louvers in
the housing assembly in order for the
humidifier to operate at peak efficiency.
At least 2"
from wall
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside
wall. With the humidifier in the desired
location, route the electrical cord safely
so no one will trip or upset the humidifier.
Plug in the electrica! cord.
WARNING: To reduce the rick of fire or chock hazard, humidifier shoutd
be pmugged directJy into a 120V A.C. out_et, Do not use extension eorde.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one
blade is wider than the other). This plug
1
will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse plug. If it still does not fit, contact
a qualified electrician to instal! the proper outlet. Do not change the plug in any way.
Water Fill
WARNmNG: To reduce the risk of shock, always unplug humidifier
before cleaning or servicing, WARNING: To reduce the risk of fire
or shock hazard, do not pour or spilt water into control or motor area.
if controls get wet, let them dry com- pletely and have unit checked by authorized service personnel before plugging in.
This humidifier is designed for use with the water bottle located to the right of the upper grill. The water bottle holds 1.9 gaF
Ions of water. The humidifier should be positioned where it will be operating.
To fill the whole house humidifier, grasp the bottle handle at the top of the bottle
and lift it straight up and away from humidifier base. Take care not to bump or damage spring valve assembly on bot-
tom of bottle. NOTE: If it is desired to use approved
bacteriostat, follow directions correctly. The bottle of the whole house humidifier
wilt hold 1_9gallons of water. The water bottle is designed with an "E-Z-
Fill Side-Cap'. Remove the "E-Z-Fi!I Side- Cap" on the side of the water bottle by
twisting counterclockwise. Place the opening of the water bottle
under a water faucet and fill. If desired, add Sears liquid bacteriostat (stock num- ber 42=14900) to help control the build up of bacteria and algae. Do not use solid
water treatments. Solid debris could make the lower valve leak.
install the "E-Z-Fill Side=Cap" by twisting clockwise. Hand tighten only.
Check for possible leaks by perform° ing the following:
1. Grasp bottle handle and hold the bottle upright over a sink.
2. Press up on valve plunger for about
one second to let out a little water.
3. Release the plunger.
/
/
B_se
Turn Cou_ltercBockwise
/ to Remove "E-Z_FiH
/
i
/
Spring VaUve AssemMy
4. Listen for air bubbles. Look for leaks around the "E=Z-Fill Side-Cap" and
valve plunger.
5. If you hear air bubbles or see leaks,
retighten the "E-Z-Fill Side-Cap" and repeat steps 1-4.
Wipe off excess water from the bottle.