Sears 390.306062 User Manual

SEARS
OWNER'S
MANUAL
Model No.
390.306062
CAUTION:
Readand Follow
All SafetyRulesand
BeforeFirstUseof
ThisProduct.
CRRFTSMRN"
BATTERY OPERATED BACKUP SUMP PUMP
Safety Instructions
Save ThisManual For FutureReference.
'Sears, Roebuck and Co., Hoffman Estates, Ik 60179 U.S.A.
PRINTED IN U.S.A. Form No. F642-9510 (Rev. 5/6198)
Operation
Installation
Troubleshooting
Repair Parts
CONTENTS
Introduction/Warranty ........................................................ 2
Safety ........................................................ _.......................... 2
Performance ........................................................................ 3
Charger Operation ............................................................... 3
Battery Requirements .......................................................... 4
Installation/Operation ...................................................... 4-5
Electrical ........................................................................... 5_
Service/Troubleshooting ..._.............................................. 6-7
Repair Parts .......................................................................... 7
INTRODUCTION
.-Ple'4_ take a few minutes to read our instructions before in-
stalling your Backup Sump Pump. It will help to assure per-
fect installation and help you avoid needless service
expenses.
IMPORTANT SAFETY INSTRUC-
TIONS for BATTERY CHARGER
I_,WARNING[ Risk of electrical shock, fire, or explo-
sion. Read all instructions in owner's manual and on
charger, pump, and battery before using battery charger.
1. Unplug battery charger before attempting any cleaning.
Turning off controls does not reduce the risk of electrical
shock.
2. Charge only rechargeable 12-volt lead-acid batteries. Other types may burst when charged with this charger.
3. Do not let charger get wet.
4. Use only attachments recommended or sold by battery charger manufacturer.
5. When unplugging charger, grasp plug (not cord) to avoid risk of damage to cord or plug.
6. Locate cord so that it cannot be stepped on, tripped over,
damaged, stretched, or flooded.
7. Do not modify cord or plug.
8. Do not attempt to service charger; it has no user-ser-
viceable parts. If charger is dropped, struck, or otherwise damaged, take it to a qualified service technician.
SAVE THESE INSTRUCTIONS
RULES FOR SAFE INSTALLATION AND OPERATION
Carefully read and follow all safety instructions in this manual or on pump.
A This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for per- sonal injury!
DANGER warns about hazards that will cause
serious personal injury, death or major property damage if
ignored.
[AW_NING]w ING warns about hazards that can
cause serious personal injury, death or major property dam- age if ignored.
[A CAUTION [CAUTION warns about hazards that will or
can cause minor personal injury or property damage if ig- nored.
The word NOTICE indicates special instructions which are important but not related to hazards.
1.To avoid risk of serious bodily injury and property dam-
age, read safety instructions carefully before installing pump.
2.Follow local and/or national plumbing and electrical
codes when installing pump. A ground fault circuit inter- rupter (GFCO is recommended for use on any electrical appliance submerged in water.
2
3.Use this pump only for backup sump pump duty in a res- idential appfication. It is not designed as a primary sump
pump.
I h
4la -- lHa o. Vo ¢.Canca € or
fatal electrical shock. Do not plug in or unplug battery
charger while standing on a wet floor or in water. Be sure
one hand isfree when pluggingin orunplugging charger.
If basement floor is wet, disconnect power to basement
before walking on floor.
5. Do not lift pump by electrical cord,
6. Pump water only with this pump.
7. Do not run pump dry.To do so will damage seals and can
cause lealdng and property damage.
8. Pump is permanently lubricated atthe factory. Do not try
to lubricate it!
9.Keep battery charger and battery box in a dry, cool, well
---ventilated area.
lO.To avoid danger of fire or explosion, keep sparks and
" flame away from battery.
11. [,AWARNING IBattery acid is corrosive. Do not spill on
skin, clothing, or battery charger. Wear eye protection when working on battery.
12. Maximum vertical pumping distance is 15 feet.
13. Make sure sump is clear of debris.
BASIC TOOLS AND MATERIALS NEEDED
Pipe Wrenches Screwdriver Hacksaw 1-1/4" Check Valve
Adjustable-Wrench Teflon Tape
Knife 12-volt Battery
If alarm sounds, check operation of primary pump, which
may need service. If battery backup operation is due to a power outage, alarm will sound, but no service is likely to
be req_,ed to primary pump.
Battery charger has capacity to run pump and charge battery
at the same time as long as power to the charger is not in- terrupted. If power to charger circuit is interrupted, the
length of time that the backup pump will run depends on
the Ampere-hour capacity of the battery used. Extended periods of operation (for example, during an ex-
tended power outage) may exhaust the battery. However, once the load is removed, usually it will self-regenerate far enough to allow the charger to start.The battery charger will
begin charging the battery as long as the battery has acharge of at least 1/2 volt, and power is available to the charger.
After power is restored, charger will automatically re-charge
battery fully in about six hours.
NOTICE: Some trouble conditions will cause the alarm to
sound. See chart below for causes and action:
PROBLEM ACTION
Back-up pump has run Push 'Reset'. Check main pump. Power out more than Disconnect charger from battery.
24 hours Call power company.
Continuous charging Disconnect charger from battery. more than 24 hours Check for defective battery.
Loose connection or Disconnect charger from battery. no power to charger Check plug, receptacle, and
power at main breaker.
After restoring power or replacing battery, alarm can be
reset.
GENERAL INFORMATION
The Battery-Powered Back-up Sump Pump is not a substitute for your primary sump pump. It is designed as a backup
pump to pinch-hit for your primary sump pump during a power outage or other problem which prevents normal op- eration. Do not use it to pump flammable fiquids or chemi-
cals. Keep battery charger dry and protected from damage.
In an emergency (such as an extended power outage) which depletes the system battery, your automobile battery
-may be temporarily substituted. Be sure to replace the sys-
tem battery as soon as possible.
CHARGER OPERATION
Backup pump will start automatically when sump water level rises far enough to trip float switch. After a delay, of
about 4 seconds, alai'm will sound. Silence alarm by pushing
ALARM TEST/RESET button. In normal (switch actuated) op-
eration, alarm is locked out until about 4 seconds after float switch has dropped to OFF position; cycle can then begin
again.
Test alarm by pushing ALARM TEST/RESET button when
alarm is not sounding. Alarm will then sound as long as but-
ton is held down. Pushing ALARM TEST/RESET button to test alarm overrides lockout, so alarm can be tested at any
time.
Purchaselocal.
For small/shallow sump pits install as illustrated above. Installation Kit 2785
includes the necessaryclamps andsupportpad needed forthisinstallation.
Follow other instructions in the owner's manual
Figure I - Installation in small or shallow sumps
- use Kit 2785; sump diameter is exaggerated for clarity.
Loading...
+ 5 hidden pages