SUMP PUMP
• Safety Instructions
• Installation
• Electrical
• Maintenance
• Repair Parts
Page 2

CONTENTS
INTROD UCT[O N/%V.M_A Nq_, 2
SAFETY 2-5
INS'I ALLATION 5-4
OPEI(ATION
LIlt FRI( _.L i-:,
Plca',c rL'ad ()Lit lu_trtlCtlOl'iS belt)Ft' sou inb[,ll[ and LISC %otlr
UCW punlp thl, \\ ill help )ntl obtam hill \ .tJttc .llld good ,er-
\icc Irom it It _ ill .ilso help \ ntt ,l\ _)id net_die,, ,t n ic_ cost,
th,u re,uh from €_.ltl,_t', %vc Lalll3OI cqll'tll¢)[ .l[Id t_anl'tOt (_o\'t.q
111 otlr k\,lrr, lll[\
INTRODUCTION
MAIN1 l_N_N( E -_
bt R\ I( E (_--
PARTS
LIMITED LIFETIME WARRANTY on CRAFTSMAN ® PROFESSIONAL SUBMERSIBLE PUMPS
Provided that it is installed ittld opel-area according to the ttlstnlCtlons in tile owner's manual if tills pump ever fails fi)r tile orlgUlal purcllaber
due to a defect m mat_tal or wot'l_lai_htp, return it to )'our nearest Sears store, arid Seat", wifi t_placc tt fr_e of charge _t Otl pa3 f()r labor zf ,, oct
chooser to have Sears mstall the replacement pump
FULL ONE YEAR WARRANTY on CRAFTSMAN ®SUBMERSIBLE PUMPS
For one year from the date of purchase, Sears will repair or replace this pump, free of charge ff defectwe in material or workmanship
LIMITED WARRANTY ON CRAFTSMAN ® 113-HP SUBMERSIBLE SUMP PUMPS
After one year and _gh two years from the date of purchase, Sears wdl furnish, free of charge, a replacement part for an_ defectt_ e part You
pay for labor.
This warranty does not cover repairs or replacement parts necessary, because of abuse or neghgence lflClUdlllg failure to install adlUst and oper-
ate this pump according to the mstructions in the owner's manual
W_ W service is available by calling Sears at 1-800-4-MY-HOME*.
LIABILITY LIMITATION
Sears is not hahlefor loss or danmge to property, nor for any mcidental or consequentvtl loss or expense from propem damage, that results dJ-
cectty or indirectly from the use of thxsproduct Some states do not allow the exclusion or Imntattonof properq, mctdental or consequential
dam_gest,so the above limitation or exchtston may not apply to )ou
This walx'am_appl_ only while tills product ts used m the United States
This warranty gives you Specific legal rights, and you ma_ also have other rights whmh vary from state to state
Sears, Roebuck and Co., Dept. 817_fA, Hoffman Estates, IL 60179
GENERAL SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
_i This is the safety alert symbol. XXqaen you see tlu_
symbol on your pump or m thts manual, luok for one
of the followmg stgnal words and he alert to the potential
for personal inltn T'
warns about hazards that will cause serious 2
personal mjury, death or malor property damage ff tgnored
l/a, WARNING_ warns abnut hazards that will or can cause se- 3
rious personal slur3,, death or ntalor property damage tf ig-
nored
[_ CAUTION ]warns about hazards that will or can cause
minor personal mjut T or property damage ff tguored
The word NOTICE mdtcates spectal mstructions which are
tmportant but not related to hazards
Elecmcally powered sump ptunps non-nally gi_ e man}' ",'ears
of trouble-free servtce when correctly mstal[ed, maintamcd,
and used However, unusual ctrcumstances (interruption of
power to the pump, dirt/debris m the sump, floodmg that ex-
ceeds the pump's capactty, elecmcal or mechanical fadure m
the pump, etc ) may prevent )'our pump from functtomng
normally To prevent possible water damage dne to floodmg,
Con_tllt }our Local Sears stoic about lil_talhtlg a secondat3.
,tnup I_tttnp or a DCbac kup _LImp pLin'tp b¢:_ b_t'x i¢.e", Page
O, for nlh)inlatton about cofinl"tt)tt sttnlp pLIn'tp ptt)blem_ al'td
renledlcs
ro a\oid task or serious Ilndll_ inlm 3 and propem dam-
ag_, read safety in._trtlctlons careftlll_ b_tnre lnstalhng
pump
Follow local and/or nation,il plumbmg and electrical
codes when installing pump
_To avoid fatal shocks, proceed as fol-
lows if pump needs servicing:
A.Disconnect power to pump outlet box before
pulling pump cord plug. Alter plug _s pulled, let
pnmp cool for 20 mmutes hcfore attempting to work
on _t Modern motors ma_ operate at high tempera-
Cures
B Take extreme care when changing fuses. To re-
duce the chance ot latal electrical shocks, DO NOT
stand m water or put \ our linger iu th_ [lime socket
C Ground the clecttac,il outlet hox
D Use only an individual branch circuit with a
Ground Fault Circuit Interrupter (GFCI) protected
grounded outlet for cord plug.
2
Page 3

SAFETY / INSTALLATION
4. Never run pump dry. To do so can damage internal
parts, ovcrheat the pump (which can cause bums to peo-
ple handling or servicing the pump), and will void the
warraoty I.
"_ DO NOT attcmI_t n) oil the i)uml) motor Aspecial oil has
been put into the motor housing at tilt" lhctot%': use ol any
other oil will vuid the warranty and could damage the
pump.
6. This pump is recommended for use in permanent instal-
latinns only. This pump has not been invenstigatcd for use
in swimming pool areas.
7. Know the pump application, limitations, and potential
hazards. Not lbr use with salt water or brine.
_Do not use in explosive atmospheres.
Pump water only with this pump. Failure to follow
this warning can result in personal injury and/or
property damage.
8. Release all pressure within the system before servicing
any component.
9. Drain water from the system before servicing.
10. Secure the discharge line before starting the pump. An un-
secnred discharge line will whip, possible causing per-
sonal injury and/or property damage.
11. Periodi _'callyinspect pump and system components. Pergoml
routine maintenance as required (See MAINTENANCE).
12. Provide a means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.
13. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, tmcluttered and properly
lighted - replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work area.
d. Make workshop child-proof - with padlocks, master
switches, and by removing starter keys.
14. This equipment is only for use on 115 volt (single phase)
and is equipped with an approved 3-conductor cord and
3-prong, grounding-type plug.
f AWARNING]To reduce the risk of electric shock,
pull plug before servicing. This pmnp has not been
investigated for use in swinlming pool areas. This
pump is supplied with a grounding conductor and
grounding-type attachment plug. Be certain that it
is connected only to a properly grounded ground-
lug-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with the National
Electrical Code and local codes and ordinances.
15.Protect electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking the cord. Replace or re-
pair damaged or worn cords immediately.
16. Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
&WARNING [Risk of electric shock. If your basement
has water or moisture on the floor, do not walk on wet
area until all power has been turned off. If shut-off
box is in ba_sement, call the electric company to shut-
off service to the house, or call your local fire depart-
nlent for instructions. Remove pump and repair or
replace. Failure to follow this warning can result in
fatal electrical shock.
ADDITIONAL INSTALLATION
MATERIALS (Purchase Separately)
Sump Pump Hose Kit, SEARS Stock No. 27909, containing
24' (7.3M) of 1-1/4" flexible plastic pipe, 1-1/4" plastic
adapter and stainless steel clamp. We recommend a Check
Valve, SEARS Stock No. 2789 or 2792.
THE SUMP
Locate sump at lowest place in basement or drained area.
Floor drains or drain tiles can also be tiled into sump.
Minimum sump size is 12" (305mm) in diameter by 24"
(610mm) deep for model 390.305001 and 10" (254mm) in
diameter by 20" deep (508mm) for models 390.304692,
390.304790 and 390.305790. Periodically inspect pump, sys-
tem components, and sump for debris and foreign objects.
Keep sump free from all refuse. Perform routine main-
tenance as required. Use a sump cover to exclude refuse
from sump. Consult local code for cover specifications.
Grounded, GFCl _ .
Protrected Outlet _"[_
Sump Cover Basement Floor
-,,, -,,,
,\\\\\\\xxxx\_.\
Sump Pit
Minimum
Diameter (D) _ ', '
Minimum
Depth (H)
_F
Figure I
Pump Minimum Minimum
Model Diameter (D) Depth (H)
300.305001 12" (305mm) 24" (610ram)
390.304692
390,304790 10" (254mm) 20" (508mm)
390.305790
Page 4

INSTALLATION / OPERATION / ELECTRICAL
PUMP INSTALLATION
Set the pump on the bottom of the sump, making sure that
it sits solidly and is level. Be sure there is enough space
around the punlp to allow the switch frec mo_ cnlcnt ;is the
stimp water level changes. Du Rot iitstall the ptimp on clay,
earth, or sand surlTace.
I_" CAUTION IRisk
. I of flooding. If a flexible discharge
hose is used, pump may move around in sump when
niotor starts. If it moves far enough so that tile switch hits
the side of the sump, the switch may stick and prevent
pump from starting. Make sure that pump is secured so that
it cannot walk arotmd in sump.
Hose Kit No. 27909 can be used as the discharge pipe. Run
the discharge pipe to the nearest sewer outlet or other point
of disposal. Use the most direct route and the fewest turns
and elbows possible.
Use Teflon tape to seal threads in plastic pipe. Hand tighten
only.
NOTE: To avoid backflow into sump when pump shuts off,
install a Check Valve, SEARS Stock No. 2789, in threaded dis-
charge port of pump. A SEARS No. 2789 Check Valve is con-
structed with an anti-aiflock hole. If you use a SEARS No. 2792
or any other check valve, drill a 1/8" hole in the discharge pipe
just above the pump discharge port and below the Check
Valve to prevent pump from airlocking.
Make sure the air-bleed hole is down inside the sump so that
it does not run water on the basement floor when the pump
is mnning.
i
AUTOMATIC FLOAT SWITCH
INSTALLATION AND OPERATION
Your SEARS Model 390.305001 Submersible Drainer comes
with the automatic float switch mounted on the motor hous-
ing ready for operation. Tether length is factory set at 3"
(76mm). Do not change tether length. See Page 6 for verti-
cal float switch instructions.
IAWARNING_ Risk of electric shock. Always disconnect
the pump and switch from the electrical power source
before doing any maintenance!
Follow instructions below to install pump with factory
mounted switch:
1. Be sure automatic float can swing freely through its entire
arc without interference from pump, piping, sump wall
or any other object.
2. Plug the automatic switch cord into a properly grounded
outlet (see "Electrical Connections", Page 4). Plug the
pump power cord into the back of the switch plug.
3. Test the installation by adding water to the sump pit until
pump operates normally as follows:
A.When sump is dry, the watertight automatic float
switch is hanging in a downward position and the
pump is off.
B. As water comes into the sump, tile auton/atic float
switch rises to an upward position and the pump starts.
(7.Water will contint_e to be pumped until the float switch
is hanging ill the dox_nward position agaiit, when
pump will stop.
DO NOT ALLOW PUMP TO RUN DRY!
Be sure to leave at least 5" (127mm) of water above
pump base plate when pump stops. Running pump
dry could ruin the pump and will void the warranty.
Figure 2
Switch tether is factor), set at 3" (76mm).
NOTICE: Do not change tether length.
ELECTRICAL CONNECTIONS
The Sump Pump has a 3-prong electric plug. The third prong
is used to ground the pump to prevent possible fatal shock.
The third prong should never be removed. Your electrical
outlet should be the 3-prong, polarized type with an inter-
nal ground.
An individual branch 15 amp electrical circuit is recom-
mended. DO NOT USE AN EXTENSION CORD.
Testing for Ground
For your safety, check your outlet for ground using an
Underwriters Laboratory Listed Circuit Analyzer (Figure 3A).
A Circuit Analyzer will tell you by a pattern of lights if the
power, neutral, and ground wires are correctly connected
to your outlet. It can also be used to check other outlets in
your home. A Circuit Analyzer is available in the Sears
Electrical Department.
UL Listed [_
Figure 3A
665 0194
4
Page 5

ELECTRICAL / MAINTENANCE
Grounding Outlet
If your outlet is not gronnded, install a copper wire, at least
14 gauge (2mm-'), from the outlet box, as shown in Figure
3B, to a metal cold \vatt'r pipe list. ground clamp on pipe.
IMPORTANT: The cold \\atcr pipe you use as a ground
nltlst have metal continuity to electrical ground, if contimv
ity is interrupted by plastic, rubber, or other electrical insu-
laturs; such as hoses, littings, washers or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector should be jumped (as shown
in Figure 3C), with a length of No. 4 wire clamped securely
at both ends.
Outlet
IBex
i
Bare copper wire to
cold water pipe.
Figure 3B
No. 4 Clamp
Wire
Metal Water
Pipe
Meter
6690194
670 0!94
Figure 3C
Automatic Thermal Overload Protection
This pump motor has a built-in automatic thermal overload
protector. If the motor overheats, the protector wiU open
and cut off power to the motor before the heat damages it
internally. The overload will reset automatically and the
pump will restart after the pump cools down below the dan-
ger point.
_DO NOT attempt to work on the pump or
motor if the overload seems to have tripped. The
motor may restart without warning at any time. You
could be injured and the pump damaged if it starts
when you are working on it.
DO NOT attempt to repair a non-operational sump pump.
Take it to Sears for service by a qualified technician.
Generator Sizing
Below is the minimum Engine4;enerator Watt rating required
to power this pump motor. Any additional loads, such as lights,
must he added to the listed load ;rodthe g_'nerator sized ac
cordiugly (;cncnltors are awdlablc at all Scars Stores
Pump Minimum Watt
Model HP Rating of Generator
390.305001 1/2 2800
390.304692 1/3 4500
390,304790 1/3 3400
390,305790 1/2 4200
MAINTENANCE
I_k CAUTION ]Make certain that the pump is unplugged
before attempting to service or remove any compo-
nent.
1. The motor in the unit is sealed in oil. No additional lubri-
cation is necessary.
2. IMPORTANT: Disassembly of the motor assembly will
void the warranty. It might also cause internal leakage and
damage to the unit. If repairs are required, return the
pump to the dealer from whom it was purchased.
3. Inlet screen should be kept clean and free of all foreign
objects.
Pump Cleaning
NOTICE: Attempting to disassemble motor will void the
warranty.
1. Disconnect power cord from electrical outlet before work-
ing on ptnnp. Tbe volute bottom may be removed to re-
place impeller or clean pump of mud or debris.
2. Remove screws from volute bottom and clean impeller.
Replace the gasket/O-Ring if it is damaged.
To Reassemble:
Attach volute bottom to volute top with screws.
5
Page 6

SERVICE / SPECIFICATIONS
General
I AWARNINGIRisk of electric shock. When servicing
pump always disconnect power to electrical outlet
and remove pump electric cord from outlet.
I. If pump does not opcnltc:
a. Check for loosc plug at electric outlet.
b. Check for blown fuses or tripped circuit breakers at
fuse box/circuit breaker box.
c. Be sure nothing interl_zrcs with action of automatic
float switch.
d. lfa, b, and c above check OK, plug in a light that you
know works. If it lights, take your pump to Sears for
service. If it doesn't light, the electrical circuit is faulty;
consult a licensed electrician.
2. Pump starts, but blows fuses/trips circuit breakers:
After disconnecting power to pump, remove the screen
and shield from the bottom of the pump and make sure
that the impeller turns freely. Remove any debris ob-
structing impeller. If pump still does not operate cor-
rectly, return it to your nearest Sears Service Department
for repairs.
3. Pump runs, but does not empty sump:
a. Clean pump intake screen.
b. Water may be entering sump faster than the pump can
discharge it.
c. Be sure vertical distance from pump discharge outlet
to discharge pipe outlet does not exceed maximum
vertical pumping distance shown in "Specifications,"
below.
d. Be sure discharge pipe is not plugged or frozen.
TEATHERED SWITCH REPLACEMENT
NOTICE: Teathcred float must bc able to swing through its
complete arc without interference from sidewall of sun]p.
l_hunl_ing or ally otiacr ohjcct.
I Rcn]<)ve ptln)p power cord fiom s\\itch plug
2. I{cmove tether clamp screw and slide cord from clamp.
3. Insert new cord in tether clamp. Put the clamp at the
same distance from the float that it was on the old switch.
4. Tighten tether clamp screw.
5. Check sump pump operation by filling sump with water
and observing operation through one complete cycle.
[_ikWARNING ]Failure to check installation with water
in sump can lead to improper operation, premature
pump failure and flooding.
Stock Maximum
Number HP Amps
30469 1/3 13.0
3050 1/2 7.6
30479 1/3 9.8
30579 112 12.0
SPECIFICATIONS
Dimensions in inches (mm)
Length
9" (229)
9" (229)
9-3/4" (248)
9-3/4" (248)
Width
6-1/2" (165)
6-1/2" (165)
7-5/16" (186)
7-5/16" (186)
Height
11-1/2" (292)
11-1/2" (292)
11-1/2" (292)
11-1/2" (292)
GPM(L/rain.)atVerticalPumpingDistancein Feet(M)
5' (1.6) 10' (3) 15' (4.6)
50(189) 41 (155) 28(106)
61 (231) 56(212) 50(189)
48(182) 39(148) 29(110)
62 (235) 53 (200) 46 (174)
! 20' (6.1) 25' (7.6)
3 (11.4) -
46(174) 43(163)
16(61) -
38 (144) 26 (98)
Page 7

SERVICE
VERTICAL SWITCH REPLACEMENT
Model 390.304692
_y
(_ Mount lhe bracket Brackel
onlo the switch Br_ckel
housing Mounting
Housing
Siip the [_o_l •
onto the rod
(_ Screw the rod
stop onto the _ (AI •
end o[ the lod Rod •
Inset1 the rod assembly
(_ up into the switch
housin 9 (A) and _ock
into place with the
pin (5_). See the inset
drawing
(_ Attach the swilch to
the pump as shown
I Screws Switch
FlOat _ "
Stop ._ (B)_
Inset Drawing
VERTICAL SWITCH REPLACEMENT
Models 390.30479 and 390.30579
!
i
Float
Rod ,_
CAUTION j Make sure pin holds float rod in switch
housing; otherwise pump will not shut off.
To check switch operation, run pump through one com-
plete cycle after installation.
[_- WARNINGj Risk of electrical shock. Can burn or kill.
Plug pump and switch into a grounded electrical outlet
only,
to Bottom of
Pump
A CAUTION 1 Make sure pin holds float rod in switch
housing; otherwise pump will not shut off.
To check switch operation, run pump through one com-
plete cycle after installation.
I_" WARNINGI Risk of electrical shock. Can burn or kill
Plug pump and switch into a grounded electrical outlet
on/y o
Page 8

REPAIR PARTS
Model 390.305001 Model390.304692
9
1
10
10
11
ltA l J
12
14A -
11 1
i
11A
14A
|
Model 390.304790 / 390.305790
9
9A
9B
-14 B
t5
Key Part
No. Description
1 Switch
2 Mounting Bracket
3 Screw
3A Cord Clip
4 Float Rod
4A Float Retainer Pin
5 Float
6 Retainer Strap
7 Float Stop
8 Screw
9 Power Cord
9A Cord Connector
9B O-Ring
10 Motor Housing
11 Upper Volute
11A Screws
12 Impeller
13 Volute Gasket
14A Base Plate
14B Lower Volute
15 Cap Screws
t 6 Cap Screw
1-1/4x1-1/2" Reducer Bushing
Quantity ONE unless otherwise noted ().
• Not illustrated.
•* If motor fails, replace entire pump.
REPAIR PARTS LIST
390.305001
PS117-144P
U30-955PS
CC0030-13
PS117-54-TSU
PS1-28P
U30-920SS (3 Req,)
PS5-22P
PS20-19
PS3-29P
U30-934ZP (8 Req.)
390.304692
PSt7-66
PSt9-18SS
U3O-955PS (3 Reg.)
PS28-17
PS30-3
PS28-18
RP0005248
PSl17-53-TSU
PS1-29P
U30-912PS (4 Req.)
RP00O0911A
PS4-17P
U30-934ZP (8 Req.)
390.304790
PSt7-85
PSt9-2OSS
U30-955PS(2 Req.)
PS28-17
PS28-18
PS19-21
RP0005248
U30-539SS
PW117-281-TSU
PS17-46P
U9-370
PS5-26P
PS20-21
PS1-34P
U30-966SS (7 Req.)
U30-967SS
U78-130P
390.305790
PS17-85
PS19-20SS
U30-955PS (2 Req.)
PS28-17
PS28-18
PS19-21
RP0005248
U30-539SS
PWt 17-237-TSU
PS17-46P
U9-370
PS5-29P
PS20-21
PS1-34P
U30-966SS (7 Req.)
U30-967SS
U78-130P
8
Page 9
Page 10

I:RRFTSMRW
OWNER'S
MANUAL
Model No.
390.305001
390.304692
390.304790
390.305790
Themodel number of
SUBMERSIBLE
SUMP PUMP
Forthe repairorreplacementpartsyouneed
Call7am - 7 pro,7claysa week
1-800-366-PART
(1-800-366-7278)
Forin-homemajorbrandrepairservice
Call24 hoursa day,7 daysa week
1-800-4-REPAIR
(1-800-473-7247)
your Submersible Sump
Pumpwill be found on a
plate attached to theside
of the motor.
When requesting service
or ordering parts, always
give the following
information:
• ProductType
• Model Number
• PartNumber
• Part Description
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Forthe locationof a
SearsRepairServiceCenterin yourarea
Call24 hoursaday,7 daysa week
1-800-488-1222
Forinformationonpurchasinga Sears
MaintenanceAgreementor to inquire
aboutanexistingAgreement
call9 am- 5 pro,Monday-Saturday
1-800-827-6655
SEARS
America'sRepair Specialists
A