Sears 390.304692 User Manual

SE/41RS
OWNER'S
MANUAL
MODEL NO.
390.305001
390.304692
390.304790
390.305790
CRAFTSMANProfessional
Model No. 390.305001
CRAFTSMANProfessional CRAFTSMANProfessional
Model No. 390.304790- 1/3 HP Model No. 390.305790- 1/2 HP
Model No. 390.304692
[RRFTSMRW
SUBMERSIBLE
CAUTION: Read and Fallow
All SafetyRulesand Operating Instructions
Before FirstUseof ThisProduct.
Save ThisManual For
FutureReference.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A. Form No. F642-9812 (Rev. 3/16/04)
SUMP PUMP
Safety Instructions
Installation
Electrical
Maintenance
Repair Parts
CONTENTS
INTROD UCT[O N/%V.M_A Nq_, 2 SAFETY 2-5
INS'I ALLATION 5-4 OPEI(ATION LIlt FRI( _.L i-:,
Plca',c rL'ad ()Lit lu_trtlCtlOl'iS belt)Ft' sou inb[,ll[ and LISC %otlr
UCW punlp thl, \\ ill help )ntl obtam hill \ .tJttc .llld good ,er- \icc Irom it It _ ill .ilso help \ ntt ,l\ _)id net_die,, ,t n ic_ cost,
th,u re,uh from €_.ltl,_t', %vc Lalll3OI cqll'tll¢)[ .l[Id t_anl'tOt (_o\'t.q
111 otlr k\,lrr, lll[\
INTRODUCTION
MAIN1 l_N_N( E -_ bt R\ I( E (_-- PARTS
LIMITED LIFETIME WARRANTY on CRAFTSMAN ® PROFESSIONAL SUBMERSIBLE PUMPS
Provided that it is installed ittld opel-area according to the ttlstnlCtlons in tile owner's manual if tills pump ever fails fi)r tile orlgUlal purcllaber due to a defect m mat_tal or wot'l_lai_htp, return it to )'our nearest Sears store, arid Seat", wifi t_placc tt fr_e of charge _t Otl pa3 f()r labor zf ,, oct
chooser to have Sears mstall the replacement pump
FULL ONE YEAR WARRANTY on CRAFTSMAN ®SUBMERSIBLE PUMPS
For one year from the date of purchase, Sears will repair or replace this pump, free of charge ff defectwe in material or workmanship
LIMITED WARRANTY ON CRAFTSMAN ® 113-HP SUBMERSIBLE SUMP PUMPS
After one year and _gh two years from the date of purchase, Sears wdl furnish, free of charge, a replacement part for an_ defectt_ e part You pay for labor.
This warranty does not cover repairs or replacement parts necessary, because of abuse or neghgence lflClUdlllg failure to install adlUst and oper- ate this pump according to the mstructions in the owner's manual
W_ W service is available by calling Sears at 1-800-4-MY-HOME*.
LIABILITY LIMITATION
Sears is not hahlefor loss or danmge to property, nor for any mcidental or consequentvtl loss or expense from propem damage, that results dJ- cectty or indirectly from the use of thxsproduct Some states do not allow the exclusion or Imntattonof properq, mctdental or consequential
dam_gest,so the above limitation or exchtston may not apply to )ou This walx'am_appl_ only while tills product ts used m the United States
This warranty gives you Specific legal rights, and you ma_ also have other rights whmh vary from state to state
Sears, Roebuck and Co., Dept. 817_fA, Hoffman Estates, IL 60179
GENERAL SAFETY INFORMATION
Carefully read and follow all safety instructions in this manual or on pump.
_i This is the safety alert symbol. XXqaen you see tlu_
symbol on your pump or m thts manual, luok for one
of the followmg stgnal words and he alert to the potential for personal inltn T'
warns about hazards that will cause serious 2
personal mjury, death or malor property damage ff tgnored
l/a, WARNING_ warns abnut hazards that will or can cause se- 3
rious personal slur3,, death or ntalor property damage tf ig- nored
[_ CAUTION ]warns about hazards that will or can cause
minor personal mjut T or property damage ff tguored The word NOTICE mdtcates spectal mstructions which are
tmportant but not related to hazards Elecmcally powered sump ptunps non-nally gi_ e man}' ",'ears
of trouble-free servtce when correctly mstal[ed, maintamcd, and used However, unusual ctrcumstances (interruption of power to the pump, dirt/debris m the sump, floodmg that ex- ceeds the pump's capactty, elecmcal or mechanical fadure m the pump, etc ) may prevent )'our pump from functtomng normally To prevent possible water damage dne to floodmg,
Con_tllt }our Local Sears stoic about lil_talhtlg a secondat3. ,tnup I_tttnp or a DCbac kup _LImp pLin'tp b¢:_ b_t'x i¢.e", Page O, for nlh)inlatton about cofinl"tt)tt sttnlp pLIn'tp ptt)blem_ al'td
renledlcs
ro a\oid task or serious Ilndll_ inlm 3 and propem dam-
ag_, read safety in._trtlctlons careftlll_ b_tnre lnstalhng pump
Follow local and/or nation,il plumbmg and electrical codes when installing pump
_To avoid fatal shocks, proceed as fol-
lows if pump needs servicing: A.Disconnect power to pump outlet box before
pulling pump cord plug. Alter plug _s pulled, let pnmp cool for 20 mmutes hcfore attempting to work on _t Modern motors ma_ operate at high tempera-
Cures
B Take extreme care when changing fuses. To re-
duce the chance ot latal electrical shocks, DO NOT stand m water or put \ our linger iu th_ [lime socket
C Ground the clecttac,il outlet hox
D Use only an individual branch circuit with a
Ground Fault Circuit Interrupter (GFCI) protected grounded outlet for cord plug.
2
SAFETY / INSTALLATION
4. Never run pump dry. To do so can damage internal
parts, ovcrheat the pump (which can cause bums to peo- ple handling or servicing the pump), and will void the
warraoty I.
"_ DO NOT attcmI_t n) oil the i)uml) motor Aspecial oil has
been put into the motor housing at tilt" lhctot%': use ol any
other oil will vuid the warranty and could damage the
pump.
6. This pump is recommended for use in permanent instal- latinns only. This pump has not been invenstigatcd for use in swimming pool areas.
7. Know the pump application, limitations, and potential hazards. Not lbr use with salt water or brine.
_Do not use in explosive atmospheres.
Pump water only with this pump. Failure to follow this warning can result in personal injury and/or
property damage.
8. Release all pressure within the system before servicing any component.
9. Drain water from the system before servicing.
10. Secure the discharge line before starting the pump. An un- secnred discharge line will whip, possible causing per- sonal injury and/or property damage.
11. Periodi _'callyinspect pump and system components. Pergoml
routine maintenance as required (See MAINTENANCE).
12. Provide a means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.
13. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, tmcluttered and properly
lighted - replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work area. d. Make workshop child-proof - with padlocks, master
switches, and by removing starter keys.
14. This equipment is only for use on 115 volt (single phase)
and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug.
f AWARNING]To reduce the risk of electric shock,
pull plug before servicing. This pmnp has not been investigated for use in swinlming pool areas. This
pump is supplied with a grounding conductor and
grounding-type attachment plug. Be certain that it
is connected only to a properly grounded ground- lug-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong receptacle installed in accordance with the National Electrical Code and local codes and ordinances.
15.Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or re-
pair damaged or worn cords immediately.
16. Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
&WARNING [Risk of electric shock. If your basement has water or moisture on the floor, do not walk on wet area until all power has been turned off. If shut-off
box is in ba_sement, call the electric company to shut- off service to the house, or call your local fire depart-
nlent for instructions. Remove pump and repair or replace. Failure to follow this warning can result in
fatal electrical shock.
ADDITIONAL INSTALLATION MATERIALS (Purchase Separately)
Sump Pump Hose Kit, SEARS Stock No. 27909, containing 24' (7.3M) of 1-1/4" flexible plastic pipe, 1-1/4" plastic
adapter and stainless steel clamp. We recommend a Check Valve, SEARS Stock No. 2789 or 2792.
THE SUMP
Locate sump at lowest place in basement or drained area. Floor drains or drain tiles can also be tiled into sump. Minimum sump size is 12" (305mm) in diameter by 24" (610mm) deep for model 390.305001 and 10" (254mm) in diameter by 20" deep (508mm) for models 390.304692,
390.304790 and 390.305790. Periodically inspect pump, sys- tem components, and sump for debris and foreign objects.
Keep sump free from all refuse. Perform routine main- tenance as required. Use a sump cover to exclude refuse from sump. Consult local code for cover specifications.
Grounded, GFCl _ .
Protrected Outlet _"[_
Sump Cover Basement Floor
-,,, -,,,
,\\\\\\\xxxx\_.\
Sump Pit Minimum
Diameter (D) _ ', '
Minimum
Depth (H)
_F
Figure I
Pump Minimum Minimum Model Diameter (D) Depth (H)
300.305001 12" (305mm) 24" (610ram)
390.304692 390,304790 10" (254mm) 20" (508mm)
390.305790
Loading...