Seametrics FT400 Specifications

FT430/440/450
d
C
RATE/TOTAL INDICATOR
Features
Simple Setup
DC Powered (FT430)
Loop Powered (FT440)
Battery Powered (FT450)
Remote or Flow Sensor Mounted
Indicator
Rugged Plastic Housing
Non-volatile Memory
Contact Your Supplier
Precision Flow Measurement
An ON
I
CON Brand
THE RIGHT INDICATOR FOR
Water Treatment
Water Utility
Optional Protective Cover Closed
The FT430/440/450 ow computers are microcontroller-based indicator/transmitters that interface with pulse output ow sensors to compute and display ow rate, ow total, and also generate output signals representing ow. The FT430 and FT450 have one scaled pulse output and one pulse pass through. The FT440 has two scaled pulse outputs. Galvanic isolation is provided for most pulse outputs.
The FT450 is battery powered while the FT430 may be powered by an external DC power source or an optional internal AC power supply*. The FT440 is a “two-wire” or “loop powered” device, meaning that it is powered by the 4-20 mA loop circuit itself. An optional internal AC power supply* is available for the FT440 with dual 24 and 12VDC outputs to power both the loop and sensors requiring more power than the loop can supply.
Pulse and 4-20mA analog outputs can be used to signal external devices, e.g. certain metering pumps and water treatment controls. Alternatively, one or more pulse outputs can be congured as alarm outputs. These ow computers can be password protected to prevent resetting the total or changing conguration settings.
The FT430/440/450 meters are available in wall and meter mount congurations. The FT430 and FT440 models can also be panel mounted. Some congurations can be converted from wall to meter or meter to wall after installation if needed. Consult factory for details.
Order the FT440 only if a 4-20mA output signal is a requirement and the FT450 if internal battery power is needed. Otherwise the FT430 oers the most exibility.
*Internal power supply is available for the wall mount option only.
Industrial Chemical Handling
o
m
e
i
p
f
i
a
t
n
r
y
C
ISO
9001:2008
253.872.0284 seametrics.com
PROUDLY MADE IN THE
USA
FT430/440/450
RATE/TOTAL INDICATOR
Specications*
FT440 FT450FT430
Power
Display
Units Rate Units
Outputs Pulse Output 1 Scaled pulse output, high alarm output or low alarm output. Optoisolated on FT430 and FT440.
Set P Range 0.1 - 99999.9 units/pulse 0.1 - 99999.9 units/pulse 0.1 - 99999.9 units/pulse
Input 5V pulse or contact closure 5V pulse or contact closure
Input Range 0.75
K-Factor Range .001 - 999999.999 .001 - 999999.999 .001 - 999999.999
Flow Alarm Output Range 0.1 - 99999.9 0.1 - 99999.9 0.1 - 99999.9
Operating Temperature -5˚ to 55˚ C (23˚ to 131˚ F) -5˚ to 55˚ C (23˚ to 131˚ F) -5˚ to 55˚ C (23˚ to 131˚ F)
Non-Operating Temperature -40˚ to 75˚ C (-40˚ to 158˚ F) -40˚ to 75˚ C (-40˚ to 158˚ F) -40˚ to 75˚ C (-40˚ to 158˚ F)
Environmental NEMA 4X, IP67 NEMA 4X, IP67 NEMA 4X, IP67
Regulatory
* Specications subject to change • Please consult our website for current data (www.seametrics.com). 1 Scaled output pulses have a xed width of 100ms. Maximum pulses per second is 6.5Hz 2 For pulse frequencies <1 Hz, increase setting in SET F menu to 3 or higher.
Rate 5-digit autorange 5-digit autorange 5-digit autorange
Total 8-digit 8-digit 8-digit
Total Units
Pulse Output 2 Pulse pass through
Loop Power Output
7-30Vdc, 4mA
Gallons/Second/Minute/Hour/Day, Liter/Second/Minute/Hour/Day, Cubic Feet/Second/Minute/Hour/Day, Cubic Meters/Second/Minute/Hour/Day, Mega Liters/Day, Million Gallons/Day, Fluid Oz/Second/Minute/Hour/Day, Barrels/ Second/Minute/Hour/Day
Gallon, Gallon x 1000, Liters, Mega Liter, Cubic Meter, Acre Feet, Cubic Feet, Cubic Feet x 1000, Million Gallon, Acre Inch, Fluid Ounce, Barrels
N/A 4-20mA Loop N/A
2
- 2000Hz 0.752 - 2000Hz 0.752 - 550Hz
Mark Mark Mark
9-30Vdc, 4mA (4-20 mA when loop-powered)
Scaled pulse output, high alarm output or low alarm output.
1
Lithium “C”, 3.6Vdc, replaceable. Life is ~5 years depending on usage.
1
Pulse pass through
Micropower GMR Sensor (square wave)
Features
Protective Cover (Optional)
Display
Setup Keys** Electronics Module Lower Housing
Strain Relief Cable Gland
Wall-Mount Brackets
**Includes password protection for tamper prevention when needed