Sealy Ease User Manual

OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
Sealy Customer Service U.S.: 1-800-499-1965 | Canada: 1-800-268-4414
Service à la clientèle Sealy É-U. : 1800-499-1965 | Canada : 1800-268-4414
table of contents / table des matières
ENGLISH FRANÇAIS
Safety Precautions and Usage Statements .................. 1–2
Parts List .................................................... 3
Base and Remote Overview .................................. 4
Quick Reference Guide ...................................... 5
Installation Guide ........................................ 6–7
Remote Control .......................................... 8–9
Emergency Baery Backup Box .............................. 10
Connecting Strap .......................................... 11
Syncing Two Bases .......................................... 12
Headboard Brackets (not included) .......................... 13
Troubleshooting ............................................ 14
Déclarations des mesures de sécurité et d’utilisation ...... 18–20
Liste des pièces ............................................ 21
Aperçu de la base et de la télécommande ................... 22
Guide de référence rapide ................................. 23
Guide d’installation ..................................... 24–25
Télécommande ........................................ 26–27
Boîtier d’alimentation de secours ........................... 28
Languee de connexion ................................... 29
Synchronisation des deux bases ............................. 30
Supports de tête de lit (non inclus) ........................... 31
Dépannage ................................................. 32
Warranty ............................................... 15–16
Notes ..................................................... 17
Garantie ............................................... 33–35
Notes ..................................................... 35
safety precautions and usage statements
Aention: Important Safety Disclaimers
Read all instructions before using your Ease™ by Sealy adjustable base.
To reduce the risk of shock, burns, re or injury:
Always unplug the base from the electrical outlet before servicing any part of the base. To reduce risk of electric shock, unplug the base before cleaning. To safely disconnect, ensure the base is in a at position with all motors o, and unplug from power source.
Keep the power cord away from heated surfaces. Never operate the base when the air openings are blocked. Keep air openings free of lint, hair and the like. Do not drop or insert any object into any opening.
Discontinue use of the bed base and contact a qualied service center if: it has a damaged cord or plug, is not working properly, or has been dropped into water.
Only use this bed base for its intended use as described in this manual. Do not use accessories/aachments that are not recommended by the manufacturer.
Close supervision is required when the bed base is used by or near children, convalescents or disabled persons.
Outlet Safety: For optimal safety and operation, plug bed base into a surge protector (not included).
e bed base should only be plugged directly into a wall outlet or surge protector (recommended). Improper connection of the equipment can result in the risk of electrical shock, electrical re or faulty operation of this bed base. If the plug does not t your outlet, contact a qualied electrician to install a suitable outlet. Unauthorized modication or failure
to use a wall outlet or surge protector could void the electrical portion of your warranty.
Warranty Warning:
Do not open or tamper with control box, motors, or remote (with the exception of baery compartments). e warranty will be void if the internal workings of these components are tampered with. For complete warranty information refer to the warranty information section on pages 15-16.
In-Home Use and Hospital Disclaimer:
e Ease™ by Sealy adjustable bases are designed solely for in-home use. is base was not designed as a hospital bed and is not designed to meet hospital standards. Do not use this base with TENT TYPE oxygen therapy equipment or near explosive gases.
Pets and Small Children:
Immediately dispose of all packing materials as they may pose a smothering risk to small children and pets. To avoid injury, it is not advised to allow children and small pets to play on or under the bed. Children should not operate the bed base without adult supervision.
Safety Features:
Casters (optional leg accessory) are equipped with locking wheels to prevent unwanted movement. Even when locked and unable to roll, it is possible for the casters to slide. Free-release head and foot motors are designed to lower the maress by retracting only with gravity, never pulling downwards, which minimizes pinch points.
1
safety precautions and usage statements
Model No: Twin — 82001-38.74-040 Twin Long — 82001-38.80-040 Full — 82001-54.74-040 Queen — 82001-60.80-040 CA King Split — 82001-36.84-040
Power Ratings:
INPUT: AC 100–240V 50/60 HZ 2.0A OUTPUT: DC 29V 1.8A WATTS: 52.2W
Product Ratings:
e li motors are not designed to operate continuously for more than two [2] minutes in an eighteen [18] minute time period or approximately 10% duty cycle. Aempting to circumvent or exceed this rating will shorten the life expectancy of the product and may void the warranty.
Weight Limits:
e recommended weight limits on the Ease™ by Sealy are: Twin / Twin Long / Full / Queen/ Split CA King: 650 pounds
Maximum weight the bed can support per person is 250 pounds. e head and foot sections are not designed to individually support or li this amount of weight. For optimal performance, enter and exit the adjustable base with the bed in the at or level position.
Ease™ by Sealy ts easily inside bed frames, furniture beds and plaorm beds that are certied to hold a minimum of 850 pounds. If using this adjustable base without the legs and placing directly on a bed frame or plaorm bed, cross-bed supports (slats) are strongly recommended to ensure Ease™ by Sealy maintains stability during operation.
Exceeding this weight restriction could damage the bed
and/or cause injury and will void the warranty.
2
Acoustics:
In normal base operation the wheels, which allow the bed to maintain its distance from the wall, will make contact with the steel plaorm supports of the base creating a contact noise. When entering, exiting or shiing weight on the base, this contact noise may be audible as the wheels make contact. is is normal.
Fabric Care:
To prolong the life of your fabric, protect from direct sunlight whenever possible. For spot cleaning, wipe area with a light damp sponge or vacuum with a so brush aachment to remove particles. Keep at a minimum of 30cm (12 inches) away from direct heat sources.
For deeper cleaning, blot liquid spills with a clean dry cloth. Wipe with a clean cloth dampened with warm water. Do not wet excessively. A so bristle brush may be used to remove ingrained soil. Avoid scratching by gentle brushing. Wipe with a clean cloth dampened with warm water to remove residues aer brushing. Dry in shade away from direct heat.
If persistent marks remain visible aer cleaning, seek professional advice.
FCC Compliance:
is device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) is device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permied. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.
Radio Frequency: 2.4 GHz
parts list
Before discarding the packing materials — ensure all the parts are accounted for.
All electronics and components that need to be installed are located in boxes under the base or aached to the frame.
A) Wireless Remote Control (1) AAA Baeries (3) B) Maress Retainer Bar (1)* C) Legs (4) D) Power Cord (1) E) Power Supply (1) F) Baery Backup Box
(9 Volt baeries not included) G) Connecting Strap ‡* H) Sync Cord ‡
Miscellaneous Parts (not included):
I) Surge Protector (1) J) 9 Volt Baeries (2)
* ese items are aached to the base for shipping purposes.
Carefully remove from base and set aside.
A) B)* C)
D) E) F)
‡* H)
G)
A
D
B
E
G
C
F
H
‡ Only included in Twin, Twin Long, Queen Split
and CA King Split bases.
3
base and remote overview
Actual product design may vary.
Head Motor
LED Light
Lis and lowers
Head portion of
the base
Lis and lowers Foot portion of the base
Lowers head and foot portions of the base to FLAT preset position
See pages 8–9 for complete Remote Control details
Control Box
Foot Motor
including Child Lock function.
4
quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
ELECTRONICS OVERVIEWCONTROL BOX OVERVIEW
Head Motor Foot Motor
Power Cord (D)
Power LED
Port Buon Head Motor
Light
To remove Control Box, release
metal clip and unplug cords.
Input Cord
Connection
Foot Motor
Port
Port
Input
Power Cord
Power Supply (E)
Control Box
Wireless
Baery Backup Box (F)
Remote
If installing a split unit — see pages 11–12.
5
installation guide
Always use two people when seing up the base.
STEP 1 STEP 4
Place the bed base box in a desired location with the boom of the box facing up.
Remove the binding straps and packing materials, making sure not to puncture the box with any sharp objects.
STEP 2
Remove the bed base from the box keeping the boom of the base facing upwards.
STEP 3
To install Headboard Brackets (sold separately)
see instructions on page 13.
Locate the Backup Baery Box and install (2) 9 Volt baeries (not included).
STEP 5
Uncoil input Power Cord (connected to Control Box’s power port) and plug into Power Supply.
To sync two bases see detailed installation
instructions on page 12.
To install the legs, thread the washer over the bolt of the leg with the recessed side facing the leg, and tighten by hand.
Do not over tighten.
6
For customer support, call Sealy Customer Service: U.S. 1-800-499-1965 | Canada 1-800-268-4414
STEP 6
Uncoil the Power Cord and connect to the Power Supply. Place Power Supply on the ground and extend from the base. Ensure that the Power Supply and all aached cords are directed toward the desired surge protector.
installation guide
STEP 7
Carefully ip the base over on to its legs. Important: Two people are required to move the bed base. Do not drag across the oor. Do not rest frame on its side, excessive pressure may damage the legs.
STEP 8
Plug the Power Cord into a power source.
A surge protector is recommended.
STEP 9
Ensure that baeries are correctly installed. Quickly test remote functions to verify proper setup before placing maress on base. Return the base to a FLAT position before placing the maress on top.
STEP 10
Slide the le side of the Maress Retainer Bar into the bracket. Pull the retainer bar to the opposite bracket and secure the right side.
Setup is now complete!
Test all functions on remote.
For customer support, call Sealy Customer Service: U.S. 1-800-499-1965 | Canada 1-800-268-4414
7
remote control
Remote Control arrives paired to the adjustable base. ree (3) AAA baeries are required to operate the remote.
LED Light
A) HEAD UP
buon
B) HEAD DOWN
buon
C) FOOT UP
buon
D) FOOT DOWN
buon
E) Bed FLAT
buon
ADJUST
Head Position Adjustments (A, B)
Use to raise and lower the head section of your adjustable base.
Foot Position Adjustments (C, D)
Use to raise and lower the foot section of your adjustable base.
Bed FLAT Buon (E)
Press down and hold for three (3) seconds to return bed to at position.
I M P O R T A N T ! For your safety, read the owner’s manual carefully and completely before operating this product. Electric shock may occur if electrical components are not installed or operated according to these guidelines.
8
For customer support, call Sealy Customer Service: U.S. 1-800-499-1965 | Canada 1-800-268-4414
remote control
Remote Pairing
e original remote that comes in the box is already paired to the adjustable base. No further action is required. In the event that the remote is not paired with the base, follow the steps below.*
STEP 1
Locate the Baery Backup Box and press the buon TWICE. A light on the Baery Back Up Box will illuminate.
POWER DOWN Buon
*ALTERNATE REMOTE PAIRING PROCESS! Locate the Control Box (see parts list on page 3) and press the buon twice. A green LED light will illuminate on the Control Box. On the back of the remote, press and hold the PAIR buon. e PAIR buon will illuminate blue and start ashing. When the PAIR buon stops ashing, the green LED light on the Control Box will go out. Release the PAIR buon. e remote is now paired to the adjustable base.
Child Lock Feature
STEP 2
On the back of the remote, press and hold down the PAIR buon. e PAIR buon will illuminate blue and start ashing. When the PAIR buon stops ashing, the illuminated light on the Baery Backup Box will go out. Release the PAIR buon. e remote is now paired to the adjustable base.
STEP 3
Test all remote functions. If the remote buons do not impact the adjustable base movements, please repeat the process again or call Sealy customer service: U.S. 1-800-499-1965 | Canada 1-800-268-4414
PAI R Buon
Activate Child Lock
Press and hold HEAD UP and HEAD DOWN buons together for approximately six (6) seconds. e LED light at the top of the remote will ash red. When the red LED light goes away, the remote is now in Child Lock. Pressing any buons while in Child Lock will yield no movement to your adjustable base.
Deactivate Child Lock
Press and hold FOOT UP and FOOT DOWN buons together for approximately six (6) seconds. e LED light at the top of the remote will ash red. When the red LED light goes away, the remote is no longer in Child Lock. e remote and adjustable base will work normally.
9
emergency baery backup box
Store the baery box in a convenient location for emergency use. Two (2) 9 Volt baeries are required to operate the power down feature and are NOT included.
OVERVIEW
For emergency use only, in case of a power outage.
In the event that the base is stuck in an articulated position during a power outage — the Baery Backup Box will return the base to a FLAT position. Baeries are not to be used for normal operation of the base.
STEP 2STEP 1
Install the 9 Volt baeries into the provided baery box.
Do not mix brand name baeries.
Press the buon on the Baery Backup Box to lower the base to FLAT position.
Control Box
10
Baery
Backup Box
Loading...
+ 26 hidden pages