PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONALREQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLYAND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURYAND WILL INVALIDATE THE WARRANTY. KEEPTHESE INSTRUCTIONS SAFE FOR FUTURE USE.
SUBMERSIBLE WATER PUMP AUTOMATIC
100LTR/MIN, 183LTR/MIN, 217LTR/MIN
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
Refer to
Instruction
Manual
1. SAFETY
1.1. ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey dealer.
If the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.2. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.3. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.4. Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is tted with the
correct fuse - see fuse rating in these instructions.
8 DO NOT pull or carry the appliance by the power cable.8DO NOT pull the plug from the socket by the cable. 8 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a
qualied electrician.
1.5. This product is tted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualied electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualied electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualied electrician.
MODEL NO’S: WPC100P, WPC150P, WPC235P
1.6. GENERAL SAFETY
WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and
water authority rules and regulations.
9Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to
the pump.
WARNING! Disconnect thepump from the mains power before changing accessories, servicing or performing any maintenance.
9 Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.9Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.9If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
9 In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
Note: this pump is not designed for continuous use in a fish pond or similar water feature or display.
8DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.8DO NOT use the pump for any purpose other than for that which it is designed.
8DO NOT use to pump, chemicals, fuels, salt water, explosive, corrosive, inflammable or health-hazardous substances, dangerous liquids
or faecal matter.
8DO NOT insert hands into the mouth of the pump as this could lead to injury.
8 DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.8DO NOT use with liquids containing abrasive materials (e.g. sand) or containing mixtures of dirt, sand, mud or clay.
8DO NOT operate the pump out of water. The pump pick up area must be completely submerged during operation.8DO NOT exceed the maximum submersible depth - see specifications.8DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
8 DO NOT pump liquids over 35° C in temperature.
8DO NOT use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids. 8DO NOT carry the pump by its electrical cable, or outlet pipe. Use the handle only.
8DO NOT kink, crush, drag or drive over the mains cable and protect it from sharp edges oil and heat.8DO NOT use extension cables.
9Always disconnect from the mains supply before attempting any maintenance etc.
9When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.
2. INTRODUCTION
Manufactured from heavy-duty corrosion resistant materials with polypropylene motor case and base cover. Fitted with an automatic cut-out,
which can be set at multiple heights using an innovative cable xed mounting bracket. Minimum water depth of 45mm. Designed for operation in
dense and dirty water with a maximum particle size of 35mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general
transfer of water and dense liquids.
3. SPECIFICATION
Model noWPC100PWPC150PWPC235P
Cut outAutomaticAutomaticAutomatic
Outlet OD32mm32mm38mm
Maximum output/min100ltr (22gal)183ltr (40gal)217ltr (48gal)
Maximum output/hr6000ltr (1320gal)11000ltr (2420gal) 13000ltr (2860gal)
Maximum head6mtr8.5mtr8.5mtr
Maximum water depth7mtr7mtr7mtr
Minimum water depth5mm5mm5mm
Maximum particle size5mm5mm5mm
Motor power250W550W750W
Supply230V230V230V
4. OPERATION
4.1. Installation and commissioning
4.1.1. Attach a sufciently long and strongrope to the handle
before rst use. The pump is submerged into the liquid
on this holding rope and can also be carried with it as
well as the handle.
NOTE: DO NOT suspend unit by the power cable.
NOTE: With continuous use of the pump, the condition
of the rope must be regularly checked as it can decay
and break over time.
4.1.2. Connect pressure pipe
4.1.2.1. For occasional use, use a suitable water hose.
4.1.2.2. The use of rigid pipes with a non return valve is
recommended for use at a xed location. This prevents
return ow of liquid when switching off.
4.1.2.3. Screw the pressure line onto the pressure connection.
4.1.2.4. All threaded connections must be sealed with thread
sealing tape.
4.1.2.5. When using a hose, screw a suitable hose adaptor onto
the pressure connection. Push the hose rmly onto the
hose adaptor and secure with a hose clamp.
4.1.3. Installation
4.1.3.1. The pump needs an area of at least 50 x 50cm (the oat switch must be able to move freely so that it functions properly.
4.1.3.2. The pump can be submerged under water to the submerged operating depth of 7metres.
4.1.3.3. Install the pump so that the suction openings cannot be blocked by foreign bodies (place the appliance on a rm, even base if
necessary.
4.1.3.4. Ensure that the pump is stable.
DO NOT lift the pump with the cable or the pressure hose as these are not designed for the tensile stress from the weight of the pump.
4.1.3.5. Submerge the pump at an angle into the liquid to be delivered, so that no air pocket forms on the underside of the appliance. Suction
would be prevented by this. Once the pump is submerged, it can be righted again.
4.1.3.6. Leave the pump at the bottom of the liquid container. Use a strong rope attached to the carrying handle of the pump for lowering.
4.1.3.7. Tighten the end of the rope rmly after lowering.
4.1.3.8. The pump can also be operated whilst suspended on a rope.
NOTE: For operation whilst suspended on the rope, DO NOT operate without the pressure hose. Avoid the pump twisting round its
longitudional axis.
4.1.4. Operation
4.1.4.1. Connect the pump to mains supply.
WARNING! The oat switch must be able to move so that the submersible pump cannot run dry, doing so would cause damage to the
unit.
4.1.4.2. The oat switch can be set at different heights by afxing it to a different slot on the unit’s body, see picture above.
• check oat switch for damage - lift and shake the switch to check the free movement of the contained metal balls
5.2. After every use:
• clean the appliance: rinse with clean water, remove stubborn contamination with a brush and detergent. Submerge the pump in a
container with clean water and switch on for a short time to rinse the inside of the pump. Clean the suction area, see below.
5.3. Cleaning the suction area
5.3.1. Clean all accessible parts of the inside of the casing. Remove bres which have wound round the rotor shaft by opening the
pressure connection. Remove stubborn contamination with a brush and detergent.
NOTE: Before using the pump again, rst ‘soak’ it so that any possible dirt residues do not block the pump.
6. STORAGE
6.1. If there is a risk of frost, dismantle the pump and accessories, clean and store them in a place protected from frost.
7. TROUBLESHOOTING
FaultCauseSolution
Pump does not run.No mains voltage?Check cables, plug, socket and fuse.
Motor overheats due to:
- liquid temperature too high
- pump blocked by foreign bodies
Residual current circuit breaker (RCCB)
triggered.
Motor defective.Contact Sealey service.
Pump runs but does not
pump.
Delivery rate lowDelivery height too great.Comply with specications (8m max. head)
Pump runs very loudly.Pump draws in air.Ensure there is sufcient liquid present.
Suction openings blocked.Rectify blockage.
Pump draws in air.Keep the pump at an angle while submerging.
Pump blocked by foreign bodies.Clean the pump suction area.
Pressure line diameter too small.Use pressure line with larger diameter.
Pressure line blocked.Rectify blockage.
Suction openings blocked.Clean suction opening.
Pressure line kinked.Straighten pressure line.
Pressure line leaks.Seal pressure line, tighten threaded connections
Eliminate the cause of the overheating of the liquid (max.
temperature of liquid able to be pumped is 35°C).
Activate RCCB.
Contact qualied electrician if RCCB triggers again.
Switch the pump on and off several times in order to expel
air.
Keep the pump at an angle while submerging.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.