Sealey wpC100.V2, wpC100a.V2, wpC150.V2, wpC150a.V2, wpC235.V2 Instruction Booklet

...
instructions for
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
submersible water pumps
model no’s:
wpC100.V2 wpC100a.V2 wpC150.V2 wpC150a.V2 wpC235.V2 wpC235a.V2 wpC250 wpC250a
thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
refer to
instruction
manual
1. saFetY
1.1. eleCtriCal saFetY warNiNG! it is the user’s responsibility to check the following:
check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and all electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electrical products. You may obtain an rcd by contacting your local sealey dealer. if the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable Appliance test) tested. electrical safety information, it is important that the following information is read and understood.
1.1.1. ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is tted with the
correct fuse - see fuse rating in these instructions. 8 DO NOt pull or carry the appliance by the power cable. 8 DO NOt pull the plug from the socket by the cable. 8 DO NOt use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or
replaced immediately by a qualied electrician.
1.1.4. This product is tted with a BS1363/A 13 Amp 3 pin plug. if the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualied electrician. Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualied electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’. b) Connect the BROWN live wire to the live terminal ‘L’. c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualied electrician.
1.1.5. only allow the minimal amount of pump cable to enter water or wet areas. the electrical cable is
designed for use in water and must not be substituted. If damaged contact a qualied electrician.
1.1.6. extension cable use. only use a cable designed for use with water equipment. contact your stockist or a qualied electrician for advice. Ensure water is kept clear of electrical mains power supply. DO NOt touch switch or plug with wet
hands.
1.2. GeNeral saFetY
 warNiNG! Pump must be used in accordance with Health & safety, government, local authority, and water authority rules and
regulations.
9 familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
 warNiNG! disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
9  maintain the pump in good condition (use an authorised service agent). Keep the pump clean.9  replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.9  only use for pumping clean cold or warm water (NOt exceeding 35ºc).9  if pump is used to pump water from a well, drain or deep receptacle, take adequate precautions to stop persons and animals falling in. 9  use the built-in handle to lower or raise the pump. it may be necessary to attach a suitable rope or pulley to the handle.9  if the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
operate above the solid matter. sand and such substances will reduce working life of pump, and invalidate your warranty.
9  in flood situations, user is responsible for ensuring that appropriate back-up procedures, alarms etc are correctly installed in case of pump
failure.
9  in swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
Note: this pump is not designed for continuous use in a fish pond or similar water feature or display.
8  DO NOt operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.8  DO NOt use the pump for any purpose other than that for which it is designed.8  DO NOt insert hands into the mouth of the pump as this could lead to injury.
reCOmmeNDeD Fuse
ratiNGs:
wpC100.V2/100a.V2: 5amp
all OtHer mODels: 13amp
© Jack sealey limited
Original Language Version
WPC100.V2, WPC100A.V2, WPC150.V2, WPC150A.V2, WPC235.V2, WPC235A.V2, WPC250, WPC250A Issue: 3(L) - 25/10/17
8  DO NOt use to pump septic tanks or settling pits. DO NOt pump any liquids other than water.8  DO NOt operate the pump out of water. the pump pick up area must be completely submerged during operation.8  DO NOt exceed the maximum submersible depth (see specifications: max. suction Height).
8 DO NOt operate the pump during freezing temperatures. DO NOt leave the pump in water that may freeze. 8 DO NOt use in swimming pools if people could come into contact with the water whilst pump is in use. 8 DO NOt use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids. 8 DO NOt carry the pump by its electrical cable, or its outlet pipe. use the handle only.
9 When not in use, switch off pump and remove plug from power supply . rinse pump, drain out any water and store in a frost free, safe
location.
warNiNG! DO NOt allow uncontrolled discharge of contaminated water which would pollute the environment.
note: this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. children should be supervised to ensure that they do not play with the appliance.
2. iNtrODuCtiON
manufactured from corrosion resistant materials with stainless steel motor case and Noryl base cover. Minimum water depth of just 20mm. designed for clean water although these pumps will accept small particles up to 5mm. suitable for the effective drainage of cellars, sinks, cisterns,
baths and the general transfer of water. The WPC100A.V2, WPC150A.V2, WPC235A.V2 and WPC250A feature an automatic low water cut-out.
3. speCiFiCatiON
model No. Cut-Out Outlet OD maximum maximum motor input maximum minimum maximum Output Head particle size water Depth water Depth
WPC100.V2 Manual 32mm 100ltr/min 6.0mtr 250W 230V 5mm 20mm 5mtr WPC150.V2 Manual 32mm 167ltr/min 8.0mtr 500W 230V 5mm 20mm 7mtr WPC235.V2 Manual 38mm 208ltr/min 8.5mtr 750W 230V 5mm 20mm 7mtr WPC250 Manual 38mm 250ltr/min 9.5mtr 900W 230V 5mm 20mm 5mtr WPC100A.V2 Automatic 32mm 100ltr/min 6.0mtr 250W 230V 5mm 20mm 5mtr WPC150A.V2 Automatic 32mm 167ltr/min 8.0mtr 500W 230V 5mm 20mm 7mtr WPC235A.V2 Automatic 38mm 208ltr/min 8.5mtr 750W 230V 5mm 20mm 7mtr WPC250A Automatic
38mm 250ltr/min 9.5mtr 900W 230V 5mm 20mm 5mtr
4. OperatiON
warNiNG! ensure you read, understand and apply safety instructions.
4.1. fit appropriate discharge pipe to pump outlet and secure with clip. ensure the diameter of the discharge pipe is the same as or
greater than the outlet diameter, as a smaller pipe will adversely effect the pump ow rate.
4.2. Position the pump in the water accordingly, and place the outlet pipe securely in the discharge receptacle or area. it is recommended that the pump is sunk with its discharge outlet facing up, to release any trapped air.
4.3. connect the pump to the electrical mains supply and switch it on.
The automatic versions will automatically turn on as the level of water rises (g.1.A). As the water level lowers, the oat will automatically switch the pump off as it reaches the minimum height (g.1.B). The oat may be adjusted by shortening or lengthening the cable. The pump will switch on if the water level is up to or above the maximum length of the oat cable. To function correctly the oat must move freely. Ensure the oat can do so and that the cable is not restricted. Check that the pump and discharge are working
correctly.
4.4. the water into which the pump is placed will act as the motor’s cooling agent. for this reason the pump must remain submerged at all times. should the pump have to be used in shallow water, DO NOt operate it for more than 10 minutes. Failure to follow this rule will damage the unit and will invalidate the warranty.
NOTE: See g.2 to determine minimum clearance required if using pump in a restricted area, i.e. a well, etc.
fig.1 fig.2
5. maiNteNaNCe
warNiNG! With the exception listed below, all pump, oat and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. failure to observe this rule may be dangerous and will invalidate the warranty.
warNiNG! ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
4.1. Keep all parts of the pump clean. rinse, drain and allow to dry before storing the pump.
© Jack sealey limited
Original Language Version
WPC100.V2, WPC100A.V2, WPC150.V2, WPC150A.V2, WPC235.V2, WPC235A.V2, WPC250, WPC250A Issue: 3(L) - 25/10/17