instructions for
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
surface mounting booster pump
stainless steel 3300ltr/hr 230v
model no: wpb050
thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
refer to
instruction
manual
Wear protective
gloves
Wear eye
protection
1. safetY
1.1. electrical safetY
warning! it is the user’s responsibility to check the following:
check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and
all electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electrical
products. You may obtain an rcd by contacting your local sealey dealer.
if the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable Appliance
test) tested.
electrical safety information, it is important that the following information is read and understood.
1.1.1. ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is tted with the
correct fuse - see fuse rating in these instructions.
8 Do not pull or carry the appliance by the power cable.
8 Do not pull the plug from the socket by the cable.
8 Do not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by a
qualied electrician.
1.1.4. This product is tted with a BS1363/A 13 Amp 3 pin plug.
if the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualied electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualied electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualied electrician.
1.2. general safetY
warning! Pump must be used in accordance with Health & safety, government, local authority and water authority rules and
regulations.
9 familiarise yourself with the application, limitations and potential hazards peculiar to the pump.
warning! disconnect the pump from the mains power before servicing or performing any maintenance.
9 maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
9 replace or repair damaged parts. use genuine parts only. unauthorised parts may be dangerous and will invalidate the warranty.
9 only use for pumping cold or warm water (not exceeding 35°c).
9 if used in situations of possible flooding, user is responsible for installing appropriate back up procedures, alarms etc. in case of pump
failure.
9 if used with swimming pools, fish ponds, etc., ensure areas are clear of people and animals (including removal of fish from ponds). note
that this pump is not designed for continuous use in a fish pond or similar water feature or display.
8 Do not operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8 Do not use the pump for any purpose other than for which it is designed and Do not modify it in any way.
8 Do not use to pump chemicals, fuels, fatty liquids or salt water.
8 Do not pump sludge, sand, gravel, mud, or fibrous materials. ensure the inlet hose will not pick up any solid materials. sand and
such substances will reduce working life of pump, and invalidate your warranty.
8 Do not use to pump septic tanks or settling pits.
8 Do not submerge the pump or the electrical cable in water. Protect the pump from external wet conditions.
8 Do not operate pump during freezing temperatures. Do not allow any part of the pump or pipes to freeze.
8 Do not carry pump by the cable, or piping. only use the handle.
8 Do not use the device in a location where there is a danger of explosion or in the vicinity of flammable liquids or gases.
9 make sure the work area is tidy and well lit.
9 Keep children and bystanders away from the work area.
8 Do not operate pump whilst tired or under the influence of alcohol, drugs or medication.
© Jack sealey limited
Original Language Version
WPB050 Issue 4 05/06/18

9 maintain correct balance and footing, wear non slip shoes whilst positioning the pump.
8 Do not point the water discharge towards another person, electrical wiring or equipment.
9 make sure that the pump is correctly positioned to prevent movement during use. ensure the area around the pump is kept clear.
9 When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
warning! Do not allow uncontrolled discharge of contaminated water, thus polluting the environment.
note: this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack
of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. children should be supervised to ensure that they do not play with the appliance.
2. i introDuction
manufactured from high impact thermoplastic material for added durability. ideal for boosting or maintaining water pressure within the
home or garden water supplies. Fitted with automatic pressure cut-off valve. Suitable for lifting water up to 8 metres.
3. i specification
model no: .................................................................WPB050
cut out: ..................................................................Automatic
outlet: .........................................................................1” BSP
maximum output: .....................................................3000ltr/hr
maximum head: .............................................................35mtr
maximum suction height:.................................................8mtr
maximum particle size: ................................................... 1mm
motor power: .................................................................800W
supply: ...........................................................................230V
tank size: ........................................................................24ltr
4. installation
4.1. general care instructions
4.1.1. Keep the pump clean and well maintained.
8 Do not use the pump if any part of it is damaged. Have it inspected by your local sealey dealer.
8 Do not run the pump dry. Make sure that the pump is already lled or ready to be lled with water, before use.
8 Do not overtighten the ller plugs as this will damage its threads.
4.1.2. make sure the pump securely anchored, through the holes in its feet, in a horizontal position.
4.1.3. the pump is designed to pump water only, Do not use it to pump ammable or corrosive liquids.
4.1.4. make sure that a strainer is always connected to the inlet hose to prevent debris from being drawn up and into the pump causing
damage.
4.2. preparation for use
warning! Do not connect the pump to the mains electrical supply until all hose installation is completed.
Connect a male inlet connector into the pump and hand tighten (g.1). Ensure that the direction of ow arrow is pointing to the pump.
Screw a non return valve (not supplied) to an inlet lter (not supplied), make sure it is correctly orientated, with the spring loaded valve
able to pass water into the lter. (Sealey recommend Water Pump Filter part no. WPF1 for use with these pumps). Make sure the bowl
of the lter is hanging down.
8 Do not over tighten any of the connections.
4.2.1. Positioning the pump (Refer to g.1)
• Check hoses for damage, they must be protected and supported as they are considerably heavier when lled with water.
• The pump must always be operated in a horizontal position with the outlet port pointing vertically upwards.
• Use the xing holes in the feet to anchor the pump in its operating position.
• Make sure there is good air circulation around the pump motor.
• The pump must not become soaked with water, neither the motor or the terminal box are waterproof.
• Place the pump as close to the water source as possible.
• Make sure there is adequate drainage for the water that is discharged.
fig.1
4.2.2. pipe connections:
• use as large a diameter inlet pipe as practical, otherwise the performance of the pump will be affected.
• a gate valve may be positioned on the outlet side of the pump. This can be used to regulate the ow of water, and be useful in
priming the pump.
© Jack sealey limited
fig.2
Original Language Version
WPB050 Issue 4 05/06/18