thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
refer to
instruction
manual
Wear protective
gloves
Wear eye
protection
1. safetY
1.1. electrical safetYwarning! it is the user’s responsibility to check the following:
check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and
all electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electrical
products. You may obtain an rcd by contacting your local sealey dealer.
if the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable Appliance
test) tested.
electrical safety information, it is important that the following information is read and understood.
1.1.1. ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is tted with the
correct fuse - see fuse rating in these instructions.
8Do not pull or carry the appliance by the power cable.8Do not pull the plug from the socket by the cable. 8Do not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by a
qualied electrician.
1.1.4. This product is tted with a BS1363/A 13 Amp 3 pin plug.
if the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualied electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualied electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualied electrician.
1.2. general safetYwarning! Pump must be used in accordance with Health & safety, government, local authority and water authority rules and
regulations.
9familiarise yourself with the application, limitations and potential hazards peculiar to the pump.
warning! disconnect the pump from the mains power before servicing or performing any maintenance.
9maintain the pump in good condition (use an authorised service agent). Keep the pump clean.9replace or repair damaged parts. use genuine parts only. unauthorised parts may be dangerous and will invalidate the warranty.9only use for pumping cold or warm water (not exceeding 35°c).9if used in situations of possible flooding, user is responsible for installing appropriate back up procedures, alarms etc. in case of pump
failure.
9if used with swimming pools, fish ponds, etc., ensure areas are clear of people and animals (including removal of fish from ponds). note
that this pump is not designed for continuous use in a fish pond or similar water feature or display.
8Do not operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8Do not use the pump for any purpose other than for which it is designed and Do not modify it in any way.8Do not use to pump chemicals, fuels, fatty liquids or salt water.8Do not pump sludge, sand, gravel, mud, or fibrous materials. ensure the inlet hose will not pick up any solid materials. sand and
such substances will reduce working life of pump, and invalidate your warranty.
8Do not use to pump septic tanks or settling pits. 8Do not submerge the pump or the electrical cable in water. Protect the pump from external wet conditions.8Do not operate pump during freezing temperatures. Do not allow any part of the pump or pipes to freeze.8Do not carry pump by the cable, or piping. only use the handle.8Do not use the device in a location where there is a danger of explosion or in the vicinity of flammable liquids or gases.
9make sure the work area is tidy and well lit.9Keep children and bystanders away from the work area.
8Do not operate pump whilst tired or under the influence of alcohol, drugs or medication.
9maintain correct balance and footing, wear non slip shoes whilst positioning the pump.
8Do not point the water discharge towards another person, electrical wiring or equipment.
9make sure that the pump is correctly positioned to prevent movement during use. ensure the area around the pump is kept clear. 9 When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
warning! Do not allow uncontrolled discharge of contaminated water, thus polluting the environment. note: this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack
of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. children should be supervised to ensure that they do not play with the appliance.
2. i introDuction
manufactured from high impact thermoplastic material for added durability. ideal for boosting or maintaining water pressure within the
home or garden water supplies. Fitted with automatic pressure cut-off valve. Suitable for lifting water up to 8 metres.
3. i specification
model no: .................................................................WPB050
tank size: ........................................................................24ltr
4. installation
4.1. general care instructions
4.1.1. Keep the pump clean and well maintained.
8Do not use the pump if any part of it is damaged. Have it inspected by your local sealey dealer.8Do not run the pump dry. Make sure that the pump is already lled or ready to be lled with water, before use.8Do not overtighten the ller plugs as this will damage its threads.
4.1.2. make sure the pump securely anchored, through the holes in its feet, in a horizontal position.
4.1.3. the pump is designed to pump water only, Do not use it to pump ammable or corrosive liquids.
4.1.4. make sure that a strainer is always connected to the inlet hose to prevent debris from being drawn up and into the pump causing
damage.
4.2. preparation for use
warning! Do not connect the pump to the mains electrical supply until all hose installation is completed.
Connect a male inlet connector into the pump and hand tighten (g.1). Ensure that the direction of ow arrow is pointing to the pump.
Screw a non return valve (not supplied) to an inlet lter (not supplied), make sure it is correctly orientated, with the spring loaded valve
able to pass water into the lter. (Sealey recommend Water Pump Filter part no. WPF1 for use with these pumps). Make sure the bowl
of the lter is hanging down.
8Do not over tighten any of the connections.
4.2.1. Positioning the pump (Refer to g.1)
• Check hoses for damage, they must be protected and supported as they are considerably heavier when lled with water.
• The pump must always be operated in a horizontal position with the outlet port pointing vertically upwards.
• Use the xing holes in the feet to anchor the pump in its operating position.
• Make sure there is good air circulation around the pump motor.
• The pump must not become soaked with water, neither the motor or the terminal box are waterproof.
• Place the pump as close to the water source as possible.
• Make sure there is adequate drainage for the water that is discharged.
fig.1
4.2.2. pipe connections:
• use as large a diameter inlet pipe as practical, otherwise the performance of the pump will be affected.
• a gate valve may be positioned on the outlet side of the pump. This can be used to regulate the ow of water, and be useful in
warning! Do not place any restriction on the inlet side of the pump, unless it is an isolator valve in a gravity fed system. the pump
should not be used with the delivery valve closed.
• if the pump is to be permanently fixed the fittings to the pump must be flexible. Short pieces of hose should be fitted to form the join
to any rigid pipes.
• ensure there are no air leaks as this will prevent effective priming and affect the pump’s capacity.
• make sure all pipes are kept as short and straight as possible.
• hoses laid across roadways need to be protected by planks to reduce “hydraulic shock” caused by vehicles running over them.
4.2.3. foot valve/filter
If the pump is used to draw raw water from a well or excavation a foot valve/coarse lter should be tted to the lower end of the suction
hose. This will retain water in the suction system and prevent large objects entering the pump body. It may be necessary to
keep the foot valve clean by:
• constructing a bed of stones to rest the foot valve on.
• position the valve to clear of the bottom of the pit, pond etc.
• securing the foot valve inside a basket or bucket.
4.2.4. preparing the booster pressure tank
An air pressure tank and regulator provide a constant water pressure at the outlet. the pump automatically cuts in when the water
pressure reaches a preset value. the regulator is pre-set at the factory and must not be altered. the following procedure must be
completed before connecting to the water supply.
• For the system to work correctly the tank must be pressurised to its rated operating pressure of between1.8 bar (26psi) and 2.0 bar
(29psi).
• Unscrew the cap on the end of the tank to reveal the air valve (see g.2).
• Use an air line or foot pump to pressurise the tank.
• check the pressure using a standard pressure gauge, replace the cap when nished.
4.2.5. priming the pump
it is essential that all connections and hoses are completely tight for the system to work. this is a self priming pump but the inlet side
of the pump still needs to be completely lled with water before initial starting or if the system has been drained for any other reason.
• Remove ller plug (g.3) and slowly ll with water until all the air is expelled.
note: Relling is necessary if the pump has been drained or if the water has been lost. Do not allow the pump to run dry.
• Open all valves on the outlet side of the pump to achieve as great a ow as possible.
• If the inlet lter is being used remove the brass plug on the top of it and ll with water.
• Turn the pump on and check for leaks. Water should begin to ow, if it fails to, check that the inlet pipe is secure and that the pump
body has been properly primed.
• If the inlet lter is being used remove the brass plug on the top of it and ll with water.
• Turn the pump on and check for leaks. Water should begin to ow, if it fails to, check that the inlet pipe is secure and that the pump body
has been properly primed.
fig.3
5. operation
5.1. open all valves in the pipes.
5.2. connect the power and switch pump on.
5.3. Wait for the pump to prime.
5.4. if the motor does not start or deliver water refer to section 7. troubleshooting.
note: to speed up the priming ll the suction pipe with water, it is recommended that a non-return valve is tted to the end of the inlet
pipe.
5.5. if debris has entered and blocked the pump the end housing can be removed for access, by unscrewing the four hex headed screws
marked ‘A’ on g.3.
5.6. stop the pump by switching it off.
5.7. If there is a danger of freezing drain water from the pump. If it has been used with dirty, contaminated or salty water, ush it through
with clean water.
note: contaminated water is water containing small solids in suspension not slurry, sludge, sand or mud.
6. maintenance
5.1. filter cleaning.
The inlet lter will need regular cleaning after use. The lter bowl will need to be unscrewed and the element washed out with soap and
water.
5.2. cleaning. regularly inspect the pump to make sure that it is not blocked. if it is suspected that it is blocked disconnect it from the mains and back
Blocked inlet hoseclean foot valve and ensure it is not submerged in
Pump runs but gives
poor output.
Pump runs but gives
poor output.
sudden loss of ow.loose or leaking connection to the
undue vibration or
noise.
inlet pipeline leakage.check inlet pipe and connector for leaks. tighten as
inlet lter is blocked.check and clean the foot valve.
impeller/mechanical seal is badly
worn.
congested material inside pump.dismantle pump and clean out.
impeller damaged and making a
poor seal.
suction lift too high.set pump as close as possible to the level of the
suction or delivery pipeline
obstructed.
congestion in the suction line.Avoid unnecessary curves, restrictions or valves.
Air leaks through damaged seal.renew seal.
inlet pipe.
suction head is too high and
causing cavitation.
excessive ow of water.decrease ow of water.
resistance in inlet pipeline.check pipe and clean out as necessary
loose rotating component.return to your dealer for repairs.
installation of pump is not stable.stop pump and reposition.
Air pocket in pump or pipeline.release drain plug in impeller housing to release air.
repair connections/replace hose as necessary.
mud, sediment etc. ensure there are no kinks in the
inlet hose.
required.
return to your sealey dealer for repair.
return to your sealey dealer for repair.
liquid to be pumped.
remove obstruction and ensure there are no kinks in
the pipeline.
check pipeline and correct.
check suction head and lower the position of the
pump.
Pump switches on
and off rapidly.
Pump switches
on and off when
no water is being
drawn.
damaged impeller.return to your sealey dealer for repair.
low air pressure.check pressure.
membrane damaged.return to your sealey dealer for repair.
leak in output side. leak in output
side.
non-return valve faulty.check and rectify.
Pressure switch faulty.return to your sealey dealer for repair.
no water at pump inlet.check for blockage.
faulty impeller.dismantle and investigate.
Original Language Version
investigate and rectify.
WPB050 Issue 4 05/06/18
environment protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson way, suffolk business park, bury st edmunds, suffolk. ip32 7ar