instructions for
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
air operated fuel drainer.
model no: tp200.V3
thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
refer to
instructions
Wear eye
protection
Wear protective
gloves
Wear safety
footwear
Wear protective
clothing
1. Safety
WarninG! Petrol is a highly flammable liquid and any spillage will evaporate to form a flammable, heavier than air vapour which
is easily ignited. common ignition sources include, but are not limited to, smoking and lit matches, welding and cutting equipment,
heaters, all types of electrical equipment unless specifically designed as suitable for use in flammable atmosphere. even low voltage
inspection lamps, if damaged, can ignite petrol vapour.
9 use the drainer only for its intended purpose.
9 familiarise yourself with the applications, limitations, and potential hazards of this product.
9 use original sealey spare parts only. unauthorised parts may be dangerous and will invalidate the warranty.
9 We recommend that this unit is used outdoors or in a well ventilated area, and well away from pits or other openings in the ground
where vapour can collect.
9 disconnect the vehicle’s battery before draining fuel.
9 Keep a foam or dry powder fire extinguisher nearby.
9 ensure containers cannot easily be knocked over during filling.
9 ensure the drainer tank is large enough to hold the contents of the fuel tank you are draining.
9 ensure space required for use and maintenance of the drainer is adequate, free from unrelated
materials and has good lighting.
9 Attach earth lead to the fuel container using the crocodile clip supplied.
9 Always use the earth bonding straps by connecting one to the vehicle chassis, away from any
potential fuel vapour, and the other to a suitable earthing point.
9 remove all combustible materials from the work area.
9 use only containers rated for the fuel being drained. ensure that the container mouth is as narrow
as possible while still allowing insertion of the drain hose.
9 Hse guidance recommends use of metal containers with secure caps for holding drained fuel.
9 mark fuel containers with hazard labels to show their contents.
9 Keep any fuel containers in a well ventilated, lockable store, preferably outside the working area.
9 soak up any spill immediately using absorbent granules or similar material.
9 Keep children and unauthorised persons away from the working area, especially when the drainer is
in operation. Keep the work area childproof by using padlocks and master switches.
9 maintain the drainer in top condition. Keep it clean for best and safest performance.
9 follow the same precautions when transferring fuel from the drainer back into the vehicle or
into any other container.
8 do not use this drainer for anything other than its intended purpose. the drainer is only to be
used for pumping fuel from diesel or petrol vehicles.
8 do not work on a fuel tank or remove a sender unit before draining the fuel.
8 do not use an open flame or smoke anywhere near the drainer or around stored fuel.
8 do not drain fuel into open-topped containers such as buckets and watering cans.
8 do not drain fuel into dedicated workshop oil drain equipment.
8 do not drain fuel into plastic containers except for quantities less than 10 litres.
8 do not allow work which can produce a source of ignition, such as welding, electrical or other hot work, to be carried out while
draining petrol.
8 do not drain fuel over, or close to, a pit or drain because of the risk of flammable vapour accumulation.
8 do not use any electrical equipment on or near the vehicle while fuel draining is in progress. this includes the use of inspection lights,
cordless/mobile phones or pagers.
8 do not store drained or contaminated fuel in the workplace unless it is to be returned to the vehicle immediately.
8 do not add drained fuel to the waste oil tank.
8 do not wear clothing on which petrol has been spilt - stop work and change into uncontaminated clothing before continuing to work.
8 do not use the drainer if the pump is damaged in any way.
8 do not stand on the drainer platform.
8 do not leave pump running unattended. turn it off and do not leave area until it has come to a complete stop.
8 do not use whilst under the influence of drugs, alcohol or other intoxicating medication, or if you are fatigued.
8 do not use the drainer for a job it was not designed to do.
© Jack sealey limited
Original Language Version
tP200.V3 | issue 3 02/02/17

2. introduction
fully mobile unit on rigid metal trolley. Air pump uses regulated (70-100psi) workshop air supply. designed to fully empty both tank and fuel lines
of petrol or diesel. includes three fuel line hoses. 40ltr drain tank built into trolley. mandatory equipment for VBrA members.
3. Specification
model no ................................................................tP200.V3
tank capacity .................................................................40ltr
recommended Air Pressure .................................. 70-100psi
Air consumption........................................................... 12cfm
4. operation
g.1
WarninG! the drainer is only to be used for pumping fuel from either a diesel or petrol vehicle. Any other use can be dangerous
and will invalidate the warranty. the unit should be reserved for only one type of fuel. do not mix different fuels in the unit unless the
unit is being used to drain a tank where fuels have been inadvertently mixed, in which case the unit should be reserved exclusively for
this purpose. Bring the unit near the vehicle when ready to begin transferring fuel. draining can be carried out in different ways depending
on the vehicle’s configuration.
Before beginning the draining process, ensure you have read and understood the safety warnings and guidelines listed in section 1 of
these instructions.
4.1. connect the earth bonding straps.
ensure each strap is tightly connected to the unit. Attach the crocodile clip from one strap to the vehicle’s chassis, away from any
potential fuel vapour, and the crocodile clip from the other strap to a suitable earthing point.
4.2. iMportant. the tP200.V3 is fitted with an overflow hose system to prevent spillage in situations where the fuel tank capacity is
greater than the capacity of the unit. Before drainage takes place the overflow hose must be placed into the neck of the vehicle’s fuel
tank and the overflow valve (fig.2) must be opened by turning it to the vertical position. the operator must not leave the unit unattended
during draining and should observe the fuel level in the sight tube, on the side of the tank, and shut the unit down when it is full.
4.3. carburettor engine vehicles. fuel can be transferred from carburettor engined vehicles through the carburettor’s fuel inlet pipe.
if this is necessary, use one of the six adaptors supplied. see type ‘A’ above and fig.3A. choose the correct diameter adaptor for the fuel
line in question.
4.3.1. screw the adaptor and washer into the quick coupling adaptor (fig.1) and then connect that into the end of the adaptor hose.
4.3.2. Plug the male fitting on the other end of the adaptor hose into the quick connector on the end of the main hose. see above.
4.3.3. Plug the male fitting on the other end of the main hose into the quick connector on the filter. see above
4.3.4. ensure the main hose is connected to the air pump as shown in fig.1.
4.3.5. disconnect the carburettor’s fuel inlet pipe and push it onto the fuel line adaptor.
© Jack sealey limited