COMPRESSOR 50/100ltr BELT dRivE 3.0hp WiTH
FRONT CONTROL PANEL.
Model Nos: SAC3503B/SAC3103B
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE THE
PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE OR PERSONAL
iNJURY ANd WiLL iNvALidATE THE WARRANTY. PLEASE KEEP iNSTRUCTiONS SAFE FOR FUTURE USE.
Refer to
instruction
manual
Warning!
Hot
surface
Warning!
electricity
Warning!
Automatic
start up
Wear ear
protection
1. SAFETY
1.1. ELECTRiCAL SAFETY
WARNiNG! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are
safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend
that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local Sealey
stockist.
If the product is used in the course of business duties, it must be
maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
electrical safety information, it is important that the following
information is read and understood.
ensure that the insulation on all cables and on the appliance is safe
before connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage
and check all connections to ensure that they are secure.
important: ensure that the voltage rating on the appliance suits the
power supply to be used and that the plug is tted with the correct fuse
- see fuse rating in these instructions.
dO NOT pull or carry the appliance by the power cable.
dO NOT pull the plug from the socket by the cable.
dO NOT use worn or damaged cables, plugs or connectors. ensure
that any faulty item is repaired or is replaced immediately by a qualied
electrician.
If the cable or plug is damaged during use, switch off the electricity
supply and remove from use.
ensure that repairs are carried out by a qualied electrician.
1.2 Model Nos SAC3503B and SAC3103B are supplied with a flying
lead without a plug. Jack Sealey Limited recommend a 16 amp
protected supply. When connecting to a 16 amp protected supply,
contact a qualified electrician, to ensure connection to a suitably
rated supply.
*Provided a good 230V supply is available and the lead length is
not increased from that supplied, the compressor may operate
from a 13 amp supply. This very much depends upon the quality of
your power supply.
Wear eye
protection
decompression
tube from switch
Non return valve
To receiver
Wear
protective
clothing
RECOMMENdEd
FUSE RATiNG:
*13 AMP
See 1.2 for power supply options.
From
pump
1.3 Wiring a BS 1363/A UK 3 Pin Plug
if in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal
‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires
have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
We recommend that you discuss the installation of an industrial round
pin plug and socket with your electrician.
iMPORTANT! The use of extension leads to connect these
compressors to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
© Jack Sealey limited
Original Language Version
Hose reel tidy
fig.1
SAC3503B, SAC3103B Issue 3 (HF) 01/08/18

1.2. GENERAL SAFETY
3 Familiarise yourself with the application and limitations of the
compressor.
3 ensure the compressor is in good order and condition before
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNiNG! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to
adjust, pressure switch or safety valve.
3 Before moving, or maintaining the compressor ensure it is
unplugged from the mains supply and that the air tank
pressure has been vented.
3 Maintain the compressor in good condition and replace any
damaged or worn parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate
your warranty.
3 Read the instructions relating to any accessory to be used
with this compressor. ensure the safe working pressure of
any air appliance used exceeds compressors output
pressure. If using a spray a gun, check that the area
selected for spraying is provided with an air change/
ventilation system.
3 ensure the air supply valve is turned off before
disconnecting the air supply hose.
3 To move the compressor use the handle only. Maintain unit’s
centre of gravity when moving or lifting. dO NOT attempt to
lift or move the compressor by any other means.
3 Use the compressor in a well ventilated area and ensure it is
placed on a firm surface.
3 Keep tools and other items away from the compressor when
it is in use, and keep area clean and clear of unnecessary
items.
3 ensure the air hose is not tangled, twisted or pinched.
3 Keep children and unauthorised persons away from the
working area.
7 dO NOT disassemble compressor for any reason. The unit
must be checked by qualified personnel only.
7 dO NOT use the compressor outdoors, or in damp, or wet,
locations.
7 dO NOT operate within the vicinity of flammable liquids,
gases or solids.
7 dO NOT touch compressor cylinder, cylinder head or pipe
from head to tank as these may be hot.
7 dO NOT use this product to perform a task for which it has
not been designed.
7 dO NOT deface the certification plate attached to the
compressor tank.
7 dO NOT cover the compressor or restrict air flow around the
unit whilst operating.
q dANGER! dO NOT direct the output jet of air towards
people or animals.
7 dO NOT operate the compressor without an air filter.
7 dO NOT allow anyone to operate the compressor unless
they have received full instructions.
7 dO NOT operate the compressor if you are tired, under the
influence of alcohol, drugs or intoxicating medication.
WARNiNG! If an electrical fuse blows, ensure it is replaced
with an identical fuse type and rating.
3 When not in use, store the compressor carefully in a safe,
dry, childproof location
WARNiNG! The air tank is a pressure vessel and the
following safety measures apply:
7 dO NOT tamper with the safety valve, dO NOT modify or
alter the tank in any way and dO NOT strap anything to the
tank.
7 dO NOT subject the tank to impact, vibration or heat.
7 dO NOT allow contact with abrasives or corrosives.
3 drain condensation from tank daily.
3 Inspection of pressure tank both internal and external.
Under the PRESSURE SYSTEMS SAFETY REGULATiONS
2000 it is the responsibility of the owner of the compressor to
initiate a system of inspection that both defines the frequency
of the inspection and appoints a person who has specific
responsibility for carrying out the inspection.
7 dO NOT carry out any welding operations on any
pressurised parts of the vessel.
2. iNTROdUCTiON & SPECiFiCATiON
A V-pump belt driven compressor, 50/100ltr, 3hp with bespoke front
control panel, with two outlets, one regulated and one direct. The
pump features heavy-duty fully cast cylinders, capped by alloy heads
for improved heat dissipation and long life. Suitable for professional
workshop applications. Powered by a heavy-duty induction motor for
reliable operation. Twin capacitors and a centrifugal switch aid
trouble free startup on a good *16amp supply. Precision continuously
welded receiver tank manufactured to meet Pressure Vessel
directive 2009/105/eC. Fitted with fully automatic pressure cut-out
switch, air regulator, receiver and supply pressure gauges. Supplied
with handle and wheels for easy manoeuvrability.
MOdEL: .............................................................................SAC3503B
Motor output: .............................................................................3.0hp
voltage/phase: ..................................................................230V - 1ph
Rated supply: ..............................................................................*16A
Speed at pump (rpm):.................................................................1140
Noise level: ............................................................................96dB(A)
Air displacement: ....................................................12.25cfm-347l/m
Maximum free air delivery: .........................................9.5cfm-270l/m
Tank capacity: ..............................................................................50ltr
Max pressure: ...............................................................145psi /10bar
Weight: ........................................................................................65kg
dimensions (W x d x H): ...................................990 x 390 x 740mm
Outlet: ..................................................Hi-flow quick release coupling
MOdEL: .............................................................................SAC3103B
Motor output: .............................................................................3.0hp
voltage/phase: ..................................................................230V - 1ph
Rated supply: ..............................................................................*16A
Speed at pump (rpm):.................................................................1140
Noise level: ............................................................................96dB(A)
Air displacement: ....................................................12.25cfm-347l/m
Maximum free air delivery: .........................................9.5cfm-270l/m
Tank capacity: ............................................................................100ltr
Max pressure: ...............................................................145psi /10bar
Weight: ........................................................................................76kg
dimensions (W x d x H): ...................................980 x 500 x 800mm
Outlet: ..................................................Hi-flow quick release coupling
Trip reset button (4.3.7.)
fig.2
fig.3
Chocks
Fully
inated
1.5bar
Wall
1000mm
nominal
© Jack Sealey limited
Original Language Version
SAC3503B, SAC3103B Issue 3 (HF) 01/08/18