Sealey SAC05030F,SAC10030F Instructions Manual

INSTRUCTIONS FOR:
COMPRESSORS 50LTR, 100LTR V-TWIN BELT DRIVE 3hp OIL FREE
PART NO’S: SAC05030F, SAC10030F
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instruction
Manual
Wear Ear
Protection
1. SAFETY
1.1. ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2 and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Inspect power supply cables and plugs regularly for wear or damage and check all connections to ensure that none are loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or replaced immediately by a qualified electrician. When an ASTA/BS approved UK 3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely. Fit a new plug according to the following instructions (UK only). a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’. c) Connect the BLUE neutral wire to the neutral terminal ‘N’. d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm² section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.
Recommended Fuse
Rating: 13A
SAC05030F,SAC10030F Issue: 1 - 26/08/15
© Jack Sealey Limited
Original Language Version
1.2. GENERAL SAFETY INSTRUCTIONS
 WARNING! Compressors must only be serviced by an authorised agent.   Familiarise yourself with the application and limitations of the compressor.   Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service
agent.
  Before moving, or maintaining the compressor ensure it is unplugged from the electrical supply and that the air tool is disconnected.   Use the compressor in a well ventilated area and ensure it is placed on a firm surface.   Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.   Keep children and unauthorised persons away from the working area.  DANGER! DO NOT direct the output jet of air towards people or animals.  WARNING! If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.   DO NOT dismantle compressor for any reason. This unit must only be checked and serviced by an approved service agent.   DO NOT use the compressor outdoors or in damp or wet locations.   DO NOT operate within the vicinity of flammable liquids, gases or solids.  DO NOT operate in a dusty environment.   DO NOT touch compressor cylinder head as it may be hot and will remain so for some time after shutdown.   DO NOT use this compressor to perform a task for which it has not been designed.   DO NOT leave the compressor running unattended.   DO NOT operate the compressor whilst under the influence of drugs, alcohol or other intoxicating medication.   DO NOT cover the compressor or restrict air flow around the machine whilst operating.   DO NOT allow anyone to operate the compressor unless they have received full instructions.   When not in use, store the compressor carefully in a safe, dry, dust free, childproof location.  When the compressor is not in use, it should be switched off, disconnected from the electrical supply and the air drained from
the tank.
Oil free V-Twin pump, ideal for applications where an oil free air supply is required. Belt driven pump and brushed electric motor with a safe and compact design to reduce weight and be more easily transported. Fitted with fully automatic pressure cut-out switch, air regulator and pressure gauges for tank and supply. Precision welded receiver tank manufactured to meet Pressure Vessel Directive 2009/105/EC. Supplied with handle and wheels for manoeuvrability. Fitted with ASTA/BS approved non-rewirable plug.
Model No: .............................SAC05030F .............................. SAC10030F
Motor Output:...........................3hp ............................................3hp
Voltage/Phase:..........................230V/1ph ...................................230V/1ph
Minimum Rated Supply: ..................13A ............................................13A
Air Displacement cfm (ltr/mim): .............11.4 (320) ..................................11.4 (320)
Maximum Free Air Delivery (cfm (ltr/min) .....8 (226) ...................................... 8 (226)
Maximum Pressure:......................116psi (8bar) .............................116psi (8bar)
Receiver Capacity: ......................50ltr ..........................................100ltr
Dimensions (W x D x H):..................790 x 320 x 630mm .................. 970 x 360 x 765mm
Weight:................................25kg .......................................... 34kg
4.1. Fix the wheels by placing the stub axle through the tank bracket as in fig.1. Ensure that there is a washer either side of the bracket and tighten the nut.
4.2. The wheel for the SAC10030F is shown. For the SAC05030F: tighten the nut onto the stub axle as above and tap the hub caps on with a soft faced hammer.
2. INTRODUCTION
3. SPECIFICATIONS
4. ASSEMBLY
fig.1
SAC05030F,SAC10030F Issue: 1 - 26/08/15
© Jack Sealey Limited
Original Language Version
Loading...
+ 2 hidden pages