Sealey sa2fr.v3, sa4fr/38.v2, sa5/rg/14.v2 Instruction Booklet

instructions for
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
air filter regulators
model no: sa2f r.v3, sa4fr/38.v2, sa5/rg/14.v2
thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
refer to
instruction
manual
Wear protective
gloves
Wear eye protection
1. safetY
WarNiNg! ensure Health & safety, local authority, and general workshop practice regulations are adhered to when using this equipment. WarNiNg! disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
9 Keep the equipment clean and maintain it in good condition (use an authorised service agent). 9 replace or repair damaged parts. use genuine parts only. unauthorised parts may be dangerous and will invalidate the warranty.
WarNiNg! ensure that the correct air pressure is maintained and not exceeded.
9 Keep air hoses away from heat, oil and sharp edges. check hoses for wear before each use and ensure that all connections are secure.
8 Do Not direct air from the air hose at yourself, others or animals.
9 drain the compressor air tank daily. Water in the air line will damage your equipment. 9 When work is complete ensure that the air supply is turned off.
2. iNtroDuctioN
Heavy-duty aluminium alloy valve assemblies - with integral filters and water traps (sA2fr and sA4fr/38). Air flow control knob can be locked in position to prevent accidental adjustment of pressure. features gauge, marked in psi, bar and kg/cm outlets are fitted with shut-off valve. suitable for direct mounting onto compressors or can be plumbed into air line runs.
2
. individual compressed air
3. i specificatioN
Part number sA2fr.V3 sA4fr/38.V2 sA5/rG/14.V2 max. inlet/outlet pressure - psi/bar 174/12 174/12 174/12 Working pressure range - psi/bar 0-115 / 0-8 0-115 / 8 30-120 / 2 - 8.2 max. ow rate - cfm @115 psi/8 bar 76 76 76 Ports: inlet - BsP 1/2” (m) 3/8” (m) 1/4” (f) outlet - BsP 1/4” x 2 (m) 1/4” x 2 (m) 1/4” (m)
sa2fr.v3 sa4fr/38.v2 sa5/rg/14.v2
© Jack sealey limited
Original Language Version
sA2fr.V3, sA4fr/38.V2, sA5/rG/14.V2 issue 2 (H, f) 05/02/18
4. asseMblY
4.1. Conrm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
4.2. Fig.1 shows a typical air line installation. The lter is located upstream of the regulator - unless combined - and the lubricator downstream.
4.3. Install lter / regulator, before connecting system piping ensure that:
a) gauge is visible b) regulator control is accessible
c) lter drain is accessible
The inlet on the lter-regulators is at the base of the lter body and the outlets are either side of the gauge.
Note: to ensure air-tight joints use Ptfe tape.
1
fig.
5. operatioN
5.1. regulator - the output pressure control knob must be lifted before turning. turn clockwise to increase and anticlockwise to reduce pressure. the output pressure will be shown on the gauge. When the required pressure is achieved, push down control knob to lock and prevent inadvertent alteration.
When setting output pressure always adjust up from a lower pressure - i.e. to adjust from 90psi to 70psi, adjust down to 60psi rst,
then up to 70psi..
5.2. Filter - The bowl should be drained daily to prevent an excessive build-up of water/oil. Regularly unscrew the lter housing from the
regulator body to access the lter for cleaning.
Parts support for sA2fr.V3 (only) is available. Please log on to
www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500
eNviroNMeNt protectioN
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.
Note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7ar
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
© Jack sealey limited
Original Language Version
sA2fr.V3, sA4fr/38.V2, sA5/rG/14.V2 issue 2 (H, f) 05/02/18