Sealey PW3500,PW4000 Instructions Manual

INSTRUCTIONS FOR
PROFESSIONAL PRESSURE WASHERS
MODEL NO: PW3500, PW4000
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
PW3500, PW4000 | Issue 5(I) 23/08/16
Original Language Version
© Jack Sealey Limited
Refer to
Instruction
Manual
Wear
Ear
Protection
Wear
Protective
Clothing
1.1. ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or replaced immediately by a qualified electrician. When an ASTA/BS approved UK 3 pin is damaged, cut the cable just above the plug and dispose of the plug safely. Fit a new plug according to the following instructions (UK only). a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’. c) Connect the BLUE neutral wire to the neutral terminal ‘N’. d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.
To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug (PW4000). In this case you MUST contact a qualified electrician to ensure that a suitable supply is available. On this model we recommend fitting a 16A plug and connecting to a 20A supply protected by a type C circuit breaker. If in any doubt take the advice of a qualified electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm ² section cable. A waterproof plug and socket should be fitted.
1.2. GENERAL SAFETY
WARNING! Water and electricity are dangerous partners. Be extremely cautious and A LWAYS be aware that this device uses an
electric motor. Always plug into a RCD (See electrical safety above). Unplug from mains before changing accessories or servicing.
WARNING! DO NOT use the washer if any part of the unit, gun, nozzle, detergent tank, hose or cables is damaged. Replace or
repair using genuine parts only. Unauthorised parts may be dangerous and will invalidate your warranty. Always check connections are correctly secured and not cracked or damaged in any way before using the machine.
WARNING! Use washer on a flat, level surface, in an upright position. Failure to do so will invalidate your warranty.
NEVER lay the washer down during use.
Ensure you comply with all local water supply regulations. Power washers may only be connected to mains water supply if a check
valve is installed in the supply hose, or at the tap outlet.
The supply hose must be reinforced, and have an internal diameter of 1/2” (13mm). The water supply must be at least equal to the .
cleaner capacity. The water temperature must NOT exceed 122°F (60°C). The water supply pressure must NOT exceed 6 bar (90psi).
SUGGESTED FUSE RATING:
13A (PW3500 ONLY)
1. SAFETY
Always be aware of the hazards that may occur during use. Study all applications and limitations of the washer before use. Use where air can freely circulate around the washer to avoid the machine overheating. Keep the washer in good condition. Use an authorised service agent to service the unit.  Wear adequate protective clothing, goggles and anti-slip rubber soled footwear. Position the washer as near to the water supply as possible.  WARNING! Ensure all persons and animals keep at a minimum distance of 15mtr from the washer when in use. WARNING! The pressure washer must only be used with clean water. Unfiltered water or corrosive chemicals must not be used as
these will damage the cleaner.
Ensure the nozzle is aimed correctly at the work surface before switching the machine on  Before activating the trigger, grip the gun firmly to counteract the recoil from the high pressure water jet.  WARNING! Avoid sudden bursts of water as these will cause water pressure to drop and put extreme pressure on hoses and
connectors.
If, during operation, power failure occurs turn the electricity and water off for safety reasons.  WARNING! The high pressure jet will cause loose particles to be propelled at high speed, which may cause serious injury. WARNING! DO NOT operate the machine without a water supply. Dry running can damage the unit seriously. WARNING! DO NOT leave the washer switched on for more than 15 minutes without operating the trigger. DO NOT obstruct ventilation grilles during operation. DO NOT use the washer with flammable or toxic liquids or any other product. Use only recommended detergent. Unapproved
detergents may corrode the machine cover and accessories.
DO NOT jam the trigger in the operating position. DO NOT adjust any internal control valves, as they have been factory set. DO NOT connect other appliances to the machine inlet or outlet. DO NOT use hoses and fittings other than those designed for use with this machine. DO NOT move the unit by pulling the hoses or electrical cables. Use the handle and tranport by means of the wheels. DO NOT touch plug with wet hands. To avoid the risk of electrocution keep all connections dry and off the ground. DO NOT direct jet against yourself, other persons, animals, electrical equipment or the machine itself. DO NOT use washer if you are tired or under the influence of alcohol, drugs or intoxicating medication. DO NOT allow children or untrained persons to operate the washer. WARNING! Discharge residual pressure before disconnecting the washer hose. Pressure left in unit may cause injury. After use, disconnect washer from electrical mains and water supply and store in a safe, dry, childproof area.  Protect from freezing conditions during winter.
NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
2. INTRODUCTION
High performance, professional unit specically designed for rigorous domestic, industrial and agricultural use. Ideal for an extremely wide range of applications including cars, 4x4s, tractors, motorbikes, ATVs, patios and decking. Fitted with a 2100W or 2800W induction motor with a
7ltr/min or10ltr/min water ow rate and a maximum pressure of 140bar or 160bar, depending on model. Features Automatic Total Stop System
(TSS) which switches the motor on and off when the lance trigger is operated, prolonging the motor life. Features innovative accessory storage
on back of unit and 8mtr high pressure hose reel ensuring the unit stays clutter free and fully mobile. Fitted with brass ttings, aluminium head, integral pressure gauge and water lter system. Supplied with 1.2ltr built-in adjustable detergent tank, variable nozzle and Rotablast nozzle
which helps develop the same effective cleaning power (ECP) as a 240bar/3450psi or 270bar/3900psi pressure washer.
3. SPECIFICATION
Model No: ............................. PW3500
Maximum Pressure:...........14MPa/140bar/2050psi
Effective Cleaning Power: ............240bar/3485psi
Working Pressure: ............12MPa/120bar/1750psi
Water Flow: ............................. 7ltr/min
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2100W
Supply:............................230V/50-60Hz
Maximum Input Temperature: ................. 50°C
Maximum Input Pressure: ....................1MPa
Gun Reaction at Maximum Pressure: .......... 18.1N
Motor Insulation: .........................Class F
Motor Protection: . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX5
Sound Pressure (EN 60704-1).............84.5dB(A)
Sound Power EN 60704-1) .................92dB(A)
Uncertainty: ..............................3dB(A)
Vibration (uncertainty: 1.5m/s²) .............3.74m/s²
Total Stop System:...........................Yes
Rotablast System: ........................... Yes
Hose Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8mtr
Weight:..................................18.8kg
Model No: ............................. PW4000
Maximum Pressure:...........16MPa/160bar/2300psi
Effective Cleaning Power: ............269bar/3910psi
Working Pressure: ............15MPa/150bar/2200psi
Water Flow: ............................ 10ltr/min
Motor Power: .............................2800W
Supply:............................230V/50-60Hz
Maximum Input Temperature: ................. 50°C
Maximum Input Pressure: ....................1MPa
Gun Reaction at Maximum Pressure: ............24N
Motor Insulation: .........................Class F
Motor Protection: . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX5
Sound Pressure (EN 60704-1).............84.5dB(A)
Sound Power EN 60704-1) .................92dB(A)
Uncertainty: ..............................3dB(A)
Vibration (uncertainty: 1.5m/s²) .............1.75m/s²
Total Stop System:...........................Yes
Rotablast System: ........................... Yes
Hose Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8mtr
Weight:..................................23.6kg
PW3500, PW4000 | Issue 5(I) 23/08/16
Original Language Version
© Jack Sealey Limited
Loading...