Sealey G1000I Instruction Booklet

INSTRUCTIONS FOR:
GENERAtoR INVERtER 1000W 230V
MODEL No: G1000I
thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ tHESE INStRuctIoNS cAREFuLLY. NotE tHE SAFE oPERAtIoNAL REQuIREMENtS, WARNINGS & cAutIoNS. uSE tHE PRoDuct coRREctLY AND WItH cARE FoR tHE PuRPoSE FoR WHIcH It IS INtENDED. FAILuRE to Do So MAY cAuSE DAMAGE AND/oR PERSoNAL INJuRY AND WILL INVALIDAtE tHE WARRANtY. KEEP tHESE INStRuctIoNS SAFE FoR FutuRE uSE.
Refer to
instructions
Warning!
Electric shock
hazard
Hot surface Outdoor use
only
1. SAFEtY
WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment. Familiarise yourself with the application and limitations, as well as the potential hazards of the generator.  Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty. This generator is designed and manufactured for specific applications. Do Not attempt to modify the unit or use it for any application for which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey stockist.  Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt, corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
connection. The total must not exceed rated wattage of generator (see specification). In most cases the rated wattage of an electrical device can be found on the nameplate. If the nameplate only gives voltage and amperage, multiply the two to give rated wattage (Volts x Amps = Watts) Do Not run at a power output between continuous and maximum for more than 15 minutes.
 WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.  WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth connector on the frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. This connection should only be attempted by a qualified electrician, after first having consulted your local Sealey stockist.  WARNING! Petrol is highly flammable and petrol vapour is explosive. Do Not permit smoking, naked flames, sparks or heat in the vicinity when handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of fuels.
 WARNING! Do Not refuel when the engine is running or when the engine is hot. Allow time for the engine to cool down.  WARNING! Do Not start or stop the generator while electrical loads are connected and switched on. Start the engine, let it
stabilise, then connect the electrical load. to stop engine, disconnect the electrical load and let engine stabilise before switching off.  WARNING! Do Not use worn, bare, frayed or otherwise damaged electrical cables with the generator. to do so may result in electric shock.
 DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the generator compartment of a caravan, may result in fire or explosion. No user-performed modifications, including venting of the exhaust and/or cooling ventilation, will eliminate the danger.
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken: the connections from standby power to a building electrical system must be carried out by a qualified electrician complying with all laws and regulations. Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the commercial electrical supply. Failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a back-feed of electrical energy.
 DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires, terminals etc. Do Not allow any unqualified person to operate or service the generator.
 DANGER! Do Not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk of personal injury and/or equipment damage. the generator supplies the correct rated frequencies and voltages only when running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads. operating at excessively low speeds may result in shortened engine life. over-speeding will invalidate the warranty.
2. INtRoDuctIoN
Digital inverter technology provides stable 'clean' output making the unit suitable for use with sensitive electrical equipment. Smart throttle sensor automatically adjusts the engine speed to precisely match the load, which allows the generator to run quieter whilst increasing fuel efficiency and lengthening engine life. Electronic ignition and a light pull recoil for easy start up. Supplied with electric circuit breaker. Fitted with 1 x 230V socket.
© Jack Sealey Limited
Original Language Version
G1000I Issue: 2(H,F) - 29/05/18
3. SPEcIFIcAtIoN
Engine Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.kW/1.47hp
Motor Type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-Stroke Petrol
Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 50Hz
Current Rating (continuous): . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.6A
Continuous Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800W
Maximum Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000W
Fuel Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5ltr
Fuel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unleaded 95 RON
Maximum Running Time: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2hr
Noise Rating: ..........................95dB(A), 60dB @ 7mtr
Dry Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5kg
Dimensions (L x W x H): . . . . . . . . . . . . . . . . . . . 300 x 240 x 330mm
4. PREPARAtIoN
4.1. uNPAcKING
Remove generator from packaging and inspect for any shortages or damage. If anything appears to be missing or damaged, contact your Sealey stockist.
5. oPERAtIoN
 WARNING! Before use, ensure you read, understand and comply with the safety instructions in this document. Ensure you understand the application and limitations fully, as well as the potential hazards of the generator.  WARNING! Never connect the generating set earth lead to pipes. Pipes may carry inflammable substances such as gas or domestic fuel and there is a risk of fire or explosion in the event of a short circuit.  WARNING! Never run the engine without an air filter fitted. PRE StARt-uP oF tHE GENERAtoR
 Check the air filter element to ensure it is clean and in good condition, clean or replace as necessary (see section 6.2).
5.1. FILLING WItH FuEL/oIL MIxtuRE  WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow time to cool down  WARNING! Petrol is highly flammable and petrol vapour is explosive.
5.1.1. Ensure the generator set is on a flat horizontal surface strong enough to prevent it from sinking.
5.1.2. If earthing the generator, connect one end of the earth lead to the chassis earthing terminal (fig.1) and the other to a low impedance earthing spike.
5.1.3. Ensure all electrical loads are disconnected.
5.1.4. Prepare fuel/oil mixture by mixing at a ratio of 50:1 = fuel:oil.
5.1.5. Remove the fuel tank filler cap, check the level of the fuel and refill with the recommended fuel if necessary.
5.1.6. Do Not over-fill the fuel tank, always leave room for the fuel to expand.
5.2. StARtING tHE GENERAtoR  WARNING! the output sockets will be live once the engine has started.
5.2.1. Ensure you have performed all actions in 5.1 above.
5.2.2. Move the choke lever to the CLOSED position (fig.2).
Note: If starting a warm engine or when the ambient temperature is high, move the choke control to the oPEN position.
5.2.3. Press the fuel primer bulb 10 times to fill the carburettor. The bulb is to be found on the underside of the carburettor body (fig.3).
5.2.4. Set the On/Off Switch to the I position (fig.4).
Note: Ensure there is sufficient free space behind to prevent personal injury when pulling the pull start.
5.2.5. Grasp the pull start handle (fig.2) and pull slowly until some resistance is felt. Let it rewind slowly, then pull with a rapid full arm stroke. Let the pull start return slowly.
5.2.6. When engine starts, move the choke lever to half choke position until engine runs smoothly and then to the OPEN position.
5.2.7. If engine fails to start, repeat the procedure from 5.2.5. If it still will not start, refer to ’Trouble-Shooting’ section. If necessary contact your authorised Sealey service agent.
5.3. uSING tHE GENERAtoR  WARNING! Do Not exceed the wattage capacity of the generator.
5.3.1. Allow the engine to warm up (approximately 3 minutes).
5.3.2. Connect the equipment to the generator socket.
5.3.3. Always observe the safety instructions for the equipment being used.
5.3.4. Carry out the following checks whilst the generator is in use: Is there any vibration or abnormal noise? Is there any backfiring or is the engine not running smoothly? What colour is the exhaust gas? (Is it black or too white.)
5.3.5. If you notice any of the above points stop the generator (paragraph 5.5) and contact your local Sealey stockist.
g.3: Underside of
carburettor
g.1
g.2
g.4
© Jack Sealey Limited
Original Language Version
G1000I Issue: 2(H,F) - 29/05/18