Sealey G1000E.V2 Instructions Manual

! WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment. " Familiarise yourself with the application and limitations, as well as the potential hazards of the generator. " Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
" This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.
! WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection
!
WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.
!
WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter), it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. This connection should only be attempted by a qualified electrician, after first having consulted your local dealer.
#
DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the generator compartment of a caravan, may result in fire or an explosion. No user-performed modifications, including venting of the exhaust and/or cooling ventilation, will eliminate the danger.
#
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken. Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or fatality, due to a back-feed of electrical energy.
#
DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare wires, terminals etc. Never allow any unqualified person to operate or service the generator.
!
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of fuels.
!
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow some time for the engine to cool down.
" Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
" Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing. " Keep non-essential persons away from the working area. !
WARNING! Never start or stop the generator while electrical loads are connected and switched on. Start the engine, let it stabilise, then connect the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.
!
WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in electric shock.
$ DO NOT use the generator for any purpose other than that for which it is designed. $ DO NOT operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury. $ DO NOT over-fill fuel tank. Always leave some room for fuel to expand. $ DO NOT operate in the rain. #
DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltages only when running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads. Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.
$ DO NOT operate the generator when you are tired or under the influence of alcohol, drugs or intoxicating medication. $ DO NOT store generator with fuel in tank where petrol vapours might reach an open flame or spark.
1. SAFETY INSTRUCTIONS
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3kW/1.7hp
Motor Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-Stroke
Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 50Hz/12V DC
Current Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.9A/8A
Cont. Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .900W
Max Power Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000W
Fuel Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.1ltr
Fuel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Petrol Unleaded 95 RON
Max Running Time: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5hr
Noise Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94dB.A
Dry Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14kg
Dimensions (L x W x H): . . . . . . . . . . . . . . . . . . .460 x 235 x 400mm
2. INTRODUCTION & SPECIFICATION
Digital inverter technology provides a stable ‘clean’ output, making the unit suitable for use with sensitive electrical equipment such as computers. A smart throttle sensor automatically adjusts the engine speed to precisely match the load, which allows the generator to run quieter whilst increasing fuel efficiency and lengthening engine life. Low oil cut-out and overload protection. Fitted with a 12V battery charging outlet and a 230V 3-pin socket.
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
G1000E.V2 - 1 - 220806
INSTRUCTIONS FOR:
INVERTER GENERATOR 1000W
MODEL:
G1000E.V2
3. OPERATING INSTRUCTIONS
fig.1
PRE-OPERATIONAL CHECKS
!
WARNING! Before use, ensure you read, understand and comply with the safety instructions in this document. Ensure you fully understand the application and limitations, as well as the potential hazards, of the generator.
!
WARNING! Never connect the generating set earth lead to pipes. Pipes may carry inflammable substances such as gas or domestic fuel and there is a risk of fire or explosion in the event of a short circuit.
!
WARNING! Never run the engine without the air filter fitted.
" Check the air filter to ensure it is clean and in good condition. " Check that the generator is standing on a flat, horizontal surface.
3.1 FILLING WITH FUEL AND OIL
!
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow the engine some time to cool down.
!
WARNING! Petrol is highly flammable and petrol vapour is explosive.
3.1.1 Ensure all electrical loads are disconnected.
3.1.2 Ensure the area around the fuel tank filler is clean.
3.1.3 Remove the fuel tank filler cap, check the level of the fuel and refill with the recommended fuel if necessary. Use unleaded petrol (95RON) to minimise combustion chamber deposits.
3.1.4 Do not over-fill the fuel tank. Always leave some room for the fuel to expand.
3.1.5 Visually inspect the oil level regularly. Take out the oil filler cap / dipstick, clean and re-insert in the filler hole but do not screw it in. If oil level is below the end of the dipstick, refill with recommended oil, up to the top of the filler neck (fig.3).
3.1.6 Use only high-detergent, premium quality 4-stroke engine oil.
Note: The Low Oil Alarm system will automatically stop the engine before the oil level falls below the safe limit, but regular
checking will avoid inconvenient shutdowns.
G1000E.V2 - 1 - 220806
fig.5
fig.4
3.2 STARTING THE GENERATOR
!
WARNING! Ensure all appliances are disconnected from the AC/DC terminals.
3.2.1 Ensure you have performed all actions in 3.1 above.
3.2.2 Turn the Engine Switch clockwise to the ON position (fig.4).
3.2.3 Move the choke lever to the right to the START position (fig.5).
Note: Do not use the choke when the engine is warm or the air temperature is high. Note: Ensure there is sufficient free area around you to prevent personal injury when pulling on the starter grip.
3.2.4 Pull the starter grip until resistance is felt, then pull the starter grip briskly upwards and engine should start running. Repeat if necessary. Do not allow the starter grip to snap back, but return it slowly.
3.2.5 After the engine has warmed up, move the choke lever to the left to the RUN position (fig.6).
3.2.6 If the engine stops and will not restart, check the engine oil level, and top up if necessary, before fault-finding in other areas.
3.2.7 If it still will not start, refer to ’Trouble-Shooting’ section. If necessary, contact your authorised Sealey service agent.
fig.2
fig.3
fig.6