8.6. Maintenance of the equipment. The equipment should be routinely maintained according to these instructions. All access and service covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in these instructions. In particular, the spark gaps of any arc striking and stabilising devices should be adjusted and maintained according to the instructions.
8.7. Cables. The welding/cutting cables should be kept as short as possible and should be positioned close together, running at or close to the floor level.
8.8. Equipotential bonding. Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered. However, metallic components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic
components.
8.9. Earthing of the workpiece. It is important that the workpiece is separately bonded to earth in addition to the welder/cutter return cable. Where the workpiece is not bonded to earth for electrical safety reasons or because of its size and position, e.g. ship’s hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by a suitable capacitance, selected according to national regulations.
8.10. Screening and shielding. Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference. Screening of the entire welding/cutting installation may be considered for special applications.
9. TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Power source fuse blown Short circuit in either primary or secondary
transformer windings Electrode has touched earth clamp Be vigilant to prevent this happening Wrongly rated fuse Install correct fuse
Welder frequently cuts out The welder is being overworked causing the
thermostatic control to activate May also be due to a sticking electrode Cut out will automatically reset when welder
Broken fan causing overheating Repair or replace cooling fan
Cooling fan not working properly Difficulty in striking or maintainig an arc
Starting capacitance disabled Replace capacitior The electrode is damp Heat it up to 60º - 70º before using Wrong type of electrode Use correct electrode Bad connection between earth clamp and
workpiece Regulation screw and nut worn out Replace worn out parts Partial short circuit in transformer windings Return to Sealey dealer for assessment/
Noise from within case when welding Uneven gap between the moving iron core
and static iron core
Return to Sealey dealer for assessment/ repair
Cut out will automatically reset when welder has cooled
has cooled
Grind connection area and reattach clamp
repair Return to Sealey Dealer to have cores
adjusted
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR
Original Language Version
01284 757500 01284 703534
140XT.V2, 160XT.V2 Issue: 2 (SP) - 30/04/15
www.sealey.co.uk
sales@sealey.co.uk
Loading...