Seagate ST300MP0015 operation manual

Product Manual
Seagate® Enterprise Performance 15K HDD v5
®
Seagate
Enterprise Turbo SSHD v2
512 Native
512 Emulation
4096 Native
512 Emulation
4096 Native
Standard Models
ST600MP0005 ST450MP0005 ST300MP0005
ST600MP0035 ST450MP0035 ST300MP0035
ST600MP0065 ST450MP0065 ST300MP0065
Standard Models
ST600MX0052 ST300MX0012
ST600MX0082 ST300MX0032
Self-Encrypting Drive Models
ST600MP0015 ST450MP0015 ST300MP0015
ST600MP0045 ST450MP0045 ST300MP0045
ST600MP0075 ST450MP0075 ST300MP0075
Enterprise Turbo SSHD
Self-Encrypting Drive Models
ST600MX0062 ST300MX0022
ST600MX0092 ST300MX0042
SED FIPS 140-2 Models
ST600MP0025
ST600MP0055
ST600MP0085
SED FIPS 140-2 Models
ST600MX0072
ST600MX0102
100748152 Rev. B April 2014
Document Revision History
Revision Date Description of Change
Rev. A 04/18/2014 Initial release.
Rev. B 04/18/2014 fc, 2, 9, 45 & bc.
© 2014 Seagate Technology LLC. All rights reserved. Publication number: 100748152, Rev. B April 2014 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or
other countries. Enterprise Performance 15K HDD and SeaTools are either trademarks or registered trademarks of Seagate Technol­ogy LLC or one of its affiliated companies in the United States and/or other countries. The FIPS logo is a certification mark of NIST, which does not imply product endorsement by NIST, the U.S., or Canadian governments. All other trademarks or registered trade­marks are the property of their respective owners.
No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC. Call 877-PUB-TEK1 (877-782-8351) to request permission. When referring to drive capacity, one gigabyte, or GB, equals one billion bytes and one terabyte, or TB, equals one trillion bytes. Your
computer’s operating system may use a different standard of measurement and report a lower capacity . In addition, some of the listed capacity is used for formatting and other functions, and thus will not be available for data storage. Actual quantities will vary based on various factors, including file size, file format, features and application software. Actual data rates may vary depending on operating environment and other factors. The export or re-export of hardware or software containing encryption may be regulated by the U.S. Department of Commerce, Bureau of Industry and Security (for more information, visit use outside of the U.S. Seagate reserves the right to change, without notice, product offerings or specifications.
www.bis.doc.gov), and controlled for import and
CONTENTS
SEAGATE® TECHNOLOGY SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.0 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0 APPLICABLE STANDARDS AND REFERENCE DOCUMENTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.1 Electromagnetic compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.2 Electromagnetic compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.3 European Union Restriction of Hazardous Substances (RoHS) . . . . . . . . . . . . . 4
2.1.4 China Restriction of Hazardous Substances (RoHS) Directive . . . . . . . . . . . . . . 4
2.2 REFERENCE DOCUMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.0 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 STANDARD FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 MEDIA DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4 RELIABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.5 FORMATTED CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.6 PROGRAMMABLE DRIVE CAPACITY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.7 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.0 PERFORMANCE CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 INTERNAL DRIVE CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 SEEK PERFORMANCE CHARACTERISTICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2.1 Format command execution time for 512-byte sectors (minutes) . . . . . . . . . . . . 9
4.2.2 General performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3 START/STOP TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.4 PREFETCH/MULTI-SEGMENTED CACHE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.5 CACHE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.5.1 Caching write data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.5.2 Prefetch operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.5.3 Hybrid caching operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.0 RELIABILITY SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1 ERROR RATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.1 Recoverable Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.2 Unrecoverable Errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.3 Seek errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.1.4 Interface errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.2 RELIABILITY AND SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.2.1 Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF) . . . . 13
5.2.2 Preventive maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.3 Hot plugging the drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.4 S.M.A.R.T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.5 Thermal monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2.6 Drive Self Test (DST). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2.7 Product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.0 PHYSICAL/ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.1 POWERCHOICETM POWER MANAGEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.1.1 PowerChoice reporting methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.2 AC POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B I
CONTENTS
6.3 DC POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.3.1 Conducted noise immunity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.3.2 Power sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.3.3 Current profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.4 POWER DISSIPATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.5 ENVIRONMENTAL LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.1 Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.2 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.3 Effective altitude (sea level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.5.4 Shock and vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.5.5 Air cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.5.6 Corrosive environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.5.7 Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.5.8 Electromagnetic susceptibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.6 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.0 ABOUT FIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.0 ABOUT SELF-ENCRYPTING DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.1 DATA ENCRYPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.2 CONTROLLED ACCESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.2.1 Admin SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.2.2 Locking SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.2.3 Default password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.3 RANDOM NUMBER GENERATOR (RNG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.4 DRIVE LOCKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.5 DATA BANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.6 CRYPTOGRAPHIC ERASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.7 AUTHENTICATED FIRMWARE DOWNLOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.8 POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.9 SUPPORTED COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.10 SANITIZE - CRYPTOGRAPHIC ERASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
8.11 REVERTSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.0 DEFECT AND ERROR MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9.1 DRIVE INTERNAL DEFECTS/ERRORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9.2 DRIVE ERROR RECOVERY PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9.3 SAS SYSTEM ERRORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.4 BACKGROUND MEDIA SCAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.5 DEFERRED AUTO-REALLOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.6 IDLE READ AFTER WRITE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.7 PROTECTION INFORMATION (PI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
9.7.1 Levels of PI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
9.7.2 Setting and determining the current Type Level. . . . . . . . . . . . . . . . . . . . . . . . . 37
9.7.3 Identifying a Protection Information drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.1 DRIVE ORIENTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.2 COOLING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.3 DRIVE MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
10.4 GROUNDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11.0 INTERFACE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.1 SAS FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B II
CONTENTS
11.1.1 Task management functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.1.2 Task management responses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.2 DUAL PORT SUPPORT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.3 SCSI COMMANDS SUPPORTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
11.3.1 Inquiry data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
11.3.2 Mode Sense data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
11.4 MISCELLANEOUS OPERATING FEATURES AND CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.4.1 SAS physical interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.4.2 Physical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
11.4.3 Connector requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
11.4.4 Electrical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
11.4.5 Pin descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
11.4.6 SAS transmitters and receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11.4.7 Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11.5 SIGNAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11.5.1 Ready LED Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11.5.2 Differential signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11.6 SAS-2 SPECIFICATION COMPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11.7 ADDITIONAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B III
FIGURES
Figure 1. Current profile for 600GB models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Figure 2. Current profile for 450B models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Figure 3. Current profile for 300B models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Figure 4. 300GB models (6Gb) DC current and power vs. input/output operations per second. . . . . . .25
Figure 5. 300GB models (12Gb) DC current and power vs. input/output operations per second. . . . . .25
Figure 6. 450GB models (6Gb) DC current and power vs. input/output operations per second. . . . . . .26
Figure 7. 450GB models (12Gb) DC current and power vs. input/output operations per second. . . . . .26
Figure 8. 600GB models (6Gb) DC current and power vs. input/output operations per second. . . . . . .27
Figure 9. 600GB models (12Gb) DC current and power vs. input/output operations per second. . . . . .27
Figure 10. Recommended mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Figure 11. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Figure 12. Example of FIPS tamper evidence labels/seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Figure 13. Physical interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Figure 14. Air flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Figure 15. Physical interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Figure 16. SAS device plug dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Figure 17. SAS device plug dimensions (detail) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Figure 18. SAS transmitters and receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B IV

Seagate® Technology Support Services

For information regarding online support and services, visit Available services include:
Presales & Technical support
Global Support Services telephone numbers & business hours
Authorized Service Centers
For information regarding Warranty Support, visit: http For information regarding data recovery services, visit For Seagate OEM and Distribution partner portal, visit: For Seagate reseller portal, visit:
http://www.seagate.com/partners/my-spp-dashboard/
http://www.seagate.com/about/contact-us/technical-support/
://www.seagate.com/support/warranty-and-replacements/
http://www.seagate.com/services-software/data-recovery-services/
http://www.seagate.com/partners/
Seagate Enterprise Performance 15K HDD v5 and Turbo SSHD v2 Product Manual, Rev. B 1

1.0 Scope

This manual describes the Seagate® Enterprise Performance 15K HDD and Enterprise Turbo SSHD - SAS (Serial Attached SCSI) disk
drives.
These drives support the SAS Protocol specifications to the extent described in this manual. The SAS Interface Manual (part number
100293071) describes the general SAS characteristics of this and other Seagate SAS drives. The Self-Encrypting Drive Reference Manual, part number 100515636, describes the interface, general operation, and security features available on Self-Encrypting Drive models.
Product data communicated in this manual is specific only to the model numbers listed in this manual. The data listed in this manual may not be predictive of future generation specifications or requirements. If designing a system which will use one of the models listed or future generation products and need further assistance, please contact the Field Applications Engineer (FAE) or our global support services group as shown in “Seagate® Technology Support Services” on page 1.
Unless otherwise stated, the information in this manual applies to standard and Self-Encrypting Drive models.
Enterprise Performance 15K HDD
Standard
Models
ST600MP0005 ST600MP0015 ST600MP0025 ST450MP0005 ST450MP0015 ST300MP0005 ST300MP0015
ST600MP0035 ST600MP0045 ST600MP0055 ST450MP0035 ST450MP0045 ST300MP0035 ST300MP0045
ST600MP0065 ST600MP0075 ST600MP0085 ST450MP0065 ST450MP0075 ST300MP0065 ST300MP0075
Enterprise Turbo SSHD
Standard
Models
Self-Encrypting Drive
(SED) Models
512 Native
512 Emulation
4096 Native
Self-Encrypting Drive
(SED) Models 512 Emulation
FIPS 140-2 Level 2
Models
FIPS 140-2 Level 2
Models
ST600MX0052 ST600MX0062 ST600MX0072 ST300MX0012 ST300MX0022
4096 Native
ST600MX0082 ST600MX0092 ST600MX0102 ST300MX0032 ST300MX0042
Note. Previous generations of Seagate Self-Encrypting Drive models were called Full Disk Encryption (FDE) models before a
differentiation between drive-based encryption and other forms of encryption was necessary.
Note. The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for “Security of Data at Rest”
based on the standards defined by the Trusted Computing Group (see
For more information on FIPS 140-2 Level 2 certification see Section 7.0 on page 32.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 2
www.trustedcomputinggroup.org).

2.0 Applicable standards and reference documentation

The drives documented in this manual have been developed as system peripherals to the highest standards of design and construction. The drives depend on host equipment to provide adequate power and environment for optimum performance and compliance with
applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regulation. In particular, the drives must be securely mounted to guarantee the specified performance characteristics. Mounting by bottom holes must meet the requirements of Section 10.3

2.1 Standards

Enterprise Performance 15K HDD and Enterprise Turbo SSHD drives complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate SAS Interface Manual, part number 100293071.
The drives are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1 as tested by CSA, and EN60950-1 as tested by TUV.
The security features of Self-Encrypting Drive models are based on the “TCG Storage Architecture Core Specification” and the “TCG
Storage Workgroup Security Subsystem Class: Enterprise_A” specification with additional vendor-unique features as noted in this product manual.

2.1.1 Electromagnetic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. The drive is supplied as a
subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communications.
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. The
drive is capable of meeting the Class B limits of the FCC Rules and Regulations of the Canadian Department of Communications when properly packaged; however, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host controller.
2.1.1.1 Electromagnetic susceptibility
As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those
integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Section 6.3, DC power requirements.

2.1.2 Electromagnetic compliance

Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications and comply with the Electromagnetic Interference/Electromagnetic Susceptibility (EMI/EMS) for Class B products. The selected system represents the most popular characteristics for test platforms. The system configurations include:
• Typical current use microprocessor
• Keyboard
• Monitor/display
• Printer
• Mouse
Although the test system with this Seagate model complies with the directives/standards, we cannot guarantee that all systems will comply. The computer manufacturer or system integrator shall confirm EMC compliance and provide the appropriate marking for their product.
Electromagnetic compliance for the European Union
If this model has the CE Marking it complies with the European Union requirements of the Electromagnetic Compatibility Directive 2004/ 108/EC as put into place on 20 July 2007.
Canada ICES-003
If this model has the ICES-003 Marking it complies with the Canadian Standard Association Standard CAN/CSA-CISPR 22-10, Information
Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement.
Australian RCM Mark
If this model has the RCM Marking it complies with the Australia/New Zealand Standard AS/NZ CISPR22 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Australia’s Radiocommunications Act.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 3
Korean KCC
If these drives have the Korean Communications Commission (KCC) logo, they comply with KN22, KN 24, and KN61000.
Taiwanese BSMI
If this model has two Chinese words meaning “EMC certification” followed by an eight digit identification number, as a Marking, it complies with
Chinese National Standard (CNS) 13438 and meets the Electromagnetic Compatibility (EMC) Framework requirements of the
Taiwanese Bureau of Standards, Metrology, and Inspection (BSMI).

2.1.3 European Union Restriction of Hazardous Substances (RoHS)

The European Union Restriction of Hazardous Substances (RoHS) Directive restricts the presence of chemical substances, including Lead
(Pb), in electronic products ef
A number of parts and materials in Seagate products are procured from external suppliers. We rely on the representations of our suppliers
regarding the presence of RoHS substances in these parts and materials. Our supplier contracts require compliance with our chemical substance restrictions, and our suppliers document their compliance with our requirements by providing material content declarations for all parts and materials for the disk drives documented in this publication. Current supplier declarations include disclosure of the inclusion of any RoHS-regulated substance in such parts or materials.
Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. These systems include standard operating procedures that ensure that restricted substances are not utilized in our manufacturing operations, laboratory analytical validation testing, and an internal auditing process to ensure that all standard operating procedures are complied with.
fective July 2006.

2.1.4 China Restriction of Hazardous Substances (RoHS) Directive

This product has an Environmental Protection Use Period (EPUP) of 20 years. The following table contains information
mandated by China's "Marking Requirements for Control of Pollution Caused by Electronic Information Products" Standard.
"O" indicates the hazardous and toxic substance content of the part (at the homogenous material level) is lower than the threshold defined by the China RoHS MCV Standard.
"X" indicates the hazardous and toxic substance content of the part (at the homogenous material level) is over the threshold defined by the China RoHS MCV Standard.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 4

2.2 Reference documents

SAS Interface Manual
Seagate part number: 100293071
SCSI Commands Reference Manual
Seagate part number: 100293068
Self-Encrypting Drives Reference Manual
Seagate part number: 100515636
ANSI SAS Documents
SFF-8223 2.5” Drive Form Factor with Serial Connector SFF-8460 HSS Backplane Design Guidelines SFF-8470 Multi Lane Copper Connector SFF-8482 SAS Plug Connector ANSI INCITS.xxx Serial Attached SCSI (SAS-2) Standard (T10/1562-D) ISO/IEC 14776-xxx SCSI Architecture Model-3 (SAM-4) Standard (T10/1561-D) ISO/IEC 14776-xxx SCSI Primary Commands-3 (SPC-4) Standard (T10/1416-D) ISO/IEC 14776-xxx SCSI Block Commands-2 (SBC-3) Standard (T10/1417-D)
ANSI Small Computer System Interface (SCSI) Documents
X3.270-1996 (SCSI-3) Architecture Model
Trusted Computing Group (TCG) Documents (apply to Self-Encrypting Drive models only)
TCG Storage Architecture Core Specification, Rev. 1.0 TCG Storage Security Subsystem Class Enterprise Specification, Rev. 1.0
Specification for Acoustic Test Requirement and Procedures
Seagate part number: 30553-001
In case of conflict between this document and any referenced document, this document takes precedence.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 5

3.0 General description

These drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network
servers, mainframes, and supercomputers. The Serial Attached SCSI interface is designed to meet next-generation computing demands for performance, scalability, flexibility and high-density storage requirements.
The hybrid functionality of the 15K drive provides improved performance over standard HDDs in real-world workloads. This improvement is
due to the addition of a solid state component that caches “hot” data for reads as well as protects write data via non-volatile cache (NVC).
These drives are random access storage devices designed to support the Serial Attached SCSI Protocol as described in the ANSI
specifications, this document, and the SAS Interface Manual (part number 100293071) which describes the general interface characteristics of this drive. These drives are classified as intelligent peripherals and provide level 2 conformance (highest level) with the
ANSI SCSI-1 standard. The SAS connectors, cables and electrical interface are compatible with Serial ATA (SATA), giving future users the
choice of populating their systems with either SAS or SATA hard disk drives. This allows integrators to continue to leverage existing investment in SCSI while gaining a 12.0Gb/s serial data transfer rate.
The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for “Security of Data at Rest” based on the
standards defined by the Trusted Computing Group (see
The head and disk assembly (HDA) is sealed at the factory. Air recirculates within the HDA through a non-replaceable filter to maintain a
contamination-free HDA environment. Note. Never disassemble the HDA and do not attempt to service items in the sealed enclosure (heads, media, actuator, etc.) as this
requires special facilities. The drive does not contain user-replaceable parts. Opening the HDA for any reason voids the warranty.
www.trustedcomputinggroup.org).
Savvio drives use a dedicated landing zone at the innermost radius of the media to eliminate the possibility of destroying or degrading data by landing in the data zone. The heads automatically go to the landing zone when power is removed from the drive.
An automatic shipping lock prevents potential damage to the heads and discs that results from movement during shipping and handling. The shipping lock disengages and the head load process begins when power is applied to the drive.
These drives decode track 0 location data from the servo data embedded on each surface to eliminate mechanical transducer adjustments
and related reliability concerns.
The drives also use a high-performance actuator assembly with a low-inertia, balanced, patented, straight arm design that provides
excellent performance with minimal power dissipation.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 6

3.1 Standard features

Enterprise Performance 15K HDD and Enterprise Turbo SSHD drives have the following standard features:
• Perpendicular recording technology
• 3.0 / 6.0 / 12.0 Gb Serial Attached SCSI (SAS) interface
• Integrated dual port SAS controller supporting the SCSI protocol
• Support for SAS expanders and fanout adapters
• Firmware downloadable using the SAS interface
• 128-deep task set (queue)
• Supports up to 32 initiators
• Jumperless configuration
• User-selectable logical block size for 512N/512e (512, 520, 524, or 528 bytes per logical block)
• User-selectable logical block size for 4KN (4096, 4160, 4192, or 4224 bytes per logical block)
• Industry standard SFF 2.5-in dimensions
• Programmable logical block reallocation scheme
• Flawed logical block reallocation at format time
• Programmable auto write and read reallocation
• Reallocation of defects on command (Post Format)
• ECC maximum burst correction length of 520 bits for 512 byte blocks and 1400 bits for 4k byte blocks
• No preventive maintenance or adjustments required
• Dedicated head landing zone and automatic shipping lock
• Embedded servo design
• Automatic shipping lock
• Self diagnostics performed when power is applied to the drive
• Zone bit recording (ZBR)
• Vertical, horizontal, or top down mounting
• Dynamic spindle brake
• 128MB data buffer (see Section 4.5)
• 32GB hybrid read cache
• 8MB Hybrid NVC-backed write cache Approximately 512K on standard models (512e, 4KN)
• Drive Self Test (DST)
• Background Media Scan (BMS)
• Idle Read After Write (IRAW)
• Power Save
• SAS Power Disable
Self-Encrypting Drive models have the following additional features:
• Automatic data encryption/decryption
• Controlled access
• Random number generator
• Drive locking
• 16 independent data bands
• Cryptographic erase of user data for a drive that will be repurposed or scrapped
• Authenticated firmware download

3.2 Media description

The media used on the drive has a glass substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer
for improved durability and environmental protection.

3.3 Performance

• Firmware-controlled multisegmented cache designed to dynamically adjust segments for enhanced system performance
• 600 MB/s maximum instantaneous data transfers
• 15K RPM spindle. Average latency = 2.0 ms
• Background processing of queue
• Supports start and stop commands (spindle stops spinning)
• Adaptive seek velocity; improved seek performance
Note. There is no significant performance difference between Self-Encrypting Drive and standard
(non-Self-Encrypting Drive) models.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 7

3.4 Reliability

• Annualized Failure Rate (AFR) of 0.44%
• Mean Time Between Failures (MTBF) of 2,000,000 hours
• Balanced low mass rotary voice coil actuator
• Incorporates industry-standard Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
• 5-year warranty

3.5 Formatted capacities

Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and must be a multiple of 4 bytes. Users having the necessary equipment may modify the data block size before issuing a format command and obtain different formatted capacities than those listed.
To provide a stable target capacity environment and at the same time provide users with flexibility if they choose, Seagate rec ommends
product planning in one of two modes: Seagate designs capacity points at certain block sizes that Seagate guarantees current and future products will meet. We recommend
customers use this capacity in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation. The current guaranteed operating points for this product are:
Capacity (Blocks)
Sector Size
512 520 524 528 4096 4160 4192 4224
Decimal Hex Decimal Hex Decimal Hex
1,172,123,568 45DD2FB0h 879,097,968 3465F870h 585,937,500 22ECB25Ch 1,147,307,696 446286B0h 860,480,776 3349E508h 573,653,848 22314358h 1,132,015,600 43792FF0h 849,011,704 329AE3F8h 566,007,800 21BC97F8h 1,115,749,560 4280FCB8h 836,812,168 31E0BD88h 557,874,778 21407E5Ah 146,515,446 8BBA5F6h 109,887,246 68CBF0Eh 73,259,046 45DD826h 143,653,848 88FFBD8h 107,740,392 66BFCE8h 71,826,928 447FDF0h 141,841,608 87454C8h 106,381,208 6573F98h 70,920,808 43A2A68h 140,767,048 863EF48h 105,575,288 64AF378h 70,383,528 431F7A8h
600GB Models 450GB Models 300GB Models

3.6 Programmable drive capacity

Using the Mode Select command, the drive can change its capacity to something less than maximum. See the Mode Select (6) parameter list table in the SAS Interface Manual, part number 100293071. A value of zero in the Number of Blocks field indicates that the drive will not change the capacity it is currently formatted to have. A number other than zero and less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the Number of Blocks field. A value greater than the maximum number of LBAs is rounded down to the maximum capacity.

3.7 Factory installed options

Integrators may order the following items which are incorporated at the manufacturing facility during production or packaged before shipping. Some of the options available are (not an exhaustive list of possible options):
• Other capacities can be ordered depending on sparing scheme and sector size requested.
• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection against transit damage. Units shipped individually require additional protection as provided by the single unit shipping pack. Users planning single unit distribution should specify this option.
• The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each standard OEM drive shipped, but extra copies may be ordered.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 8

4.0 Performance characteristics

This section provides detailed information concerning performance-related characteristics and features of Enterprise Performance 15K
HDD and Enterprise Turbo SSHD drives.

4.1 Internal drive characteristics

600GB Models 450GB Models 300GB Models
Drive capacity 600 450 300 GB (formatted, rounded off value) Read/write data heads 6 6 4 Bytes per track 1095/1168 1142/1158 1142/1158 KBytes (avg, rounded off values)(4KN or 512e / 512N) Bytes per surface 100,000 75,000 75,000 MB (unformatted, rounded off values Tracks per surface (total) 114 86/93 86/93 KTracks (user accessible) (4KN or 512e / 512N) Tracks per in 289 218/234 218/234 KTPI (average) (4KN or 512e / 512N) Peak bits per in 1704/1816 1779/1805 1779/1805 KBPI
Areal density 479/530 518/526 518/526 Gb/in2 (4KN or 512e / 512N)
Disk rotation speed 15K 15K 15K RPM Avg rotational latency 2.0 2.0 2.0 ms

4.2 Seek performance characteristics

4.2.1 Format command execution time for 512-byte sectors (minutes)

600GB Models 450GB Models 300GB models
Maximum (with verify) 120 90 60 Maximum (without verify) 60 45 30
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
When changing sector sizes, the format times shown above may need to be increased by 30 minutes.

4.2.2 General performance characteristics

Sustained transfer rate 180 to 246 MiB/s 4KN/512e **
160 to 233 MiB/s 512N **
SAS Interface maximum instantaneous transfer rate 1200 MB/s* per port
(dual port = 2,400 MB/s*)
Logical block sizes
512 (default), 520, 524 and 528
4k - 4096 (default), 4160, 4192, and 4224 Read/write consecutive sectors on a track Yes Flaw reallocation performance impact (for flaws reallocated at format time using the
Negligible
spare sectors per sparing zone reallocation scheme.) Average rotational latency 2.0 ms * Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or
from the host. ** MiB/s x 1.048 = MB/s
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 9

4.3 Start/stop time

The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a ST AR T STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a ST ART ST OP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive wa its for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the d rive r ece ive s a START STOP UN IT com man d wit h the START bi t and IM MED b it eq ual to 1 a nd do es not r ece ive a N OTIF Y (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 seconds (maximum) from
removal of DC power. SCSI stop time is 20 seconds. There is no power control switch on the drive.

4.4 Prefetch/multi-segmented cache control

The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system
performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual operation, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2.
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this drive family are given in Table
10 for 300GB, Table 11 for 450GB and Table 12 for 600GB.

4.5 Cache operation

Note. Refer to the SAS Interface Manual for more detail concerning the cache bits.
Of the 128MB physical buffer space in the drive, approximately 60,000KB are available as a data cache. The remaining buffer space is reserved for internal drive use.
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the cache is enabled (see RCD bit
in the SAS Interface Manual ), data requested by the host with a read command is retrieved from the buffer, if possible, before any disk access is initiated. If cache operation is not enabled, the buffer is still used, but only as circular buffer segments during disk medium read operations (disregarding Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the requested read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through some buffer segment on the way to the host. All data transfers to the host are in accordance with buffer-full ratio rules. See the explanation provided with the information about Mode Page 02h (disconnect/reconnect control) in the SAS Interface Manual.
The following is a simplified description of the prefetch/cache operation:
Case A—read command is received and all of the requested logical blocks are already in the cache:
1. Drive transfers the requested logical blocks to the initiator. Case B—A Read command requests data, and at least one requested logical block is not in any segment of the cache:
1. The drive fetches the requested logical blocks from the disk and transfers them into a segment, and then from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
2. If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.
Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The drive dynamically creates and removes segments based on the workload. The wrap-around capability of the individual segments greatly enhances the cache’s overall performance.
Note. The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15. The value 0XFFFF is always
reported regardless of the actual size of the segment. Sending a size specification using the Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable parameter.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 10

4.5.1 Caching write data

Note. Write caching in this section is the traditional SCSI write caching (WCE=1) where writes are not protected on power loss.
Hybrid provides NVC-protected write caching when WCE=0 over a portion of the DRAM. Note. Refer to the SAS Interface Manual for more detail concerning the cache bits.” Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is
stored while the drive performs the Write command. If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made available for future read cache
hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently , having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.
If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be generated.
The Synch roni ze Cac he comm and ma y be use d to forc e the dr ive to w rite a ll cach ed wri te data t o the me dium . Upon c omple tion o f a
Synchronize Cache command, all data received from previous write commands will have been written to the medium. in Table 10 for 300GB, Table 11 for 450GB and Table 12 for 600GB shows the mode default settings.

4.5.2 Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.
To enable prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch. The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur.

4.5.3 Hybrid caching operations

Hybrid caching operation Read data that has been promoted into the hybrid read cache does not persist through a power cycle. The read data can always be retrieved from the rotating media.
When WCE=0, Hybrid 10K provides NVC-protected write caching over the portion of the DRAM used to coalesce writes. Write data only goes into NVC when there is an unexpected power loss to the drive. The NVC has 90-day data retention.
If WCE=1, then a hybrid drive will operate on writes like a standard HDD–writes in cache are not protected by NVC and may be lost with power loss.”
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 11

5.0 Reliability specifications

The following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply
voltages, environmental requirements and drive mounting constraints.
Seek error rate: Less than 10 errors in 108 seeks Read Error Rates
Recovered Data Less than 10 errors in 1012 bits transferred (OEM default settings) Unrecovered Data Less than 1 sector in 10
Miscorrected Data Less than 1 sector in 10 Interface error rate: Less than 1 error in 10 Mean Time Between Failure (MTBF): 2,000,000 hours Annualized Failure Rate (AFR) 0.44% Preventive maintenance: None required
1. Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.

5.1 Error rates

The error rates stated in this manual assume the following:
• The drive is operated in accordance with this manual using DC power as defined in paragraph 6.3, "DC power requirements."
• Errors caused by host system failures are excluded from error rate computations.
• Assume random data.
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write retries and full retry time.
1
16
bits transferred
21
bits transferred
12
bits transferred

5.1.1 Recoverable Errors

Recoverable errors are those detected and corrected by the drive, and do not require user intervention. Recoverable Data errors will use Error Correction when needed. Recovered Data e rror rat e is deter mined usi ng read bi ts trans ferred f or recove rable er rors occ urring d uring a rea d, and usi ng write bits
transferred for recoverable errors occurring during a write.

5.1.2 Unrecoverable Errors

An unrecoverable data error is defined as a failure of the drive to recover data from the media. These errors occur due to head/media or
write problems. Unrecoverable data errors are only detected during read operations, but not caused by the read. If an unrecoverable data error is detected, a MEDIUM ERROR (03h) in the Sense Key will be reported. Multiple unrecoverable data errors resulting from the same cause are treated as 1 error.

5.1.3 Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive
automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 10 Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

5.1.4 Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the
receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error.
8
seeks.

5.2 Reliability and service

Integrators can enhance the reliability of Enterprise Performance 15K HDD and Enterprise Turbo SSHD disk drives can be enhanced
by ensuring that the drive receives adequate cooling. Section 6.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 10.2 provides recommended air-flow information.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 12

5.2.1 Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF)

The production disk drive shall achieve an annualized failure-rate of 0.44% (MTBF of 2,000,000 hours) over a 5 year service life when
used in Enterprise Storage field conditions as limited by the following:
• 8760 power-on hours per year.
• HDA temperature as reported by the drive <= 50C
• Ambient wet bulb temp <= 26°C
• The AFR (MTBF) is a population statistic not relevant to individual units.
• ANSI/ISA S71.04-2013 G2 classification levels and dust contamination to ISO 14644-1 Class 8 standards (as measured at the device)
The MTBF specification for the drive assumes the operating environment is designed to maintain nominal drive temperature and humidity. The rated MTBF is based upon a sustained drive temperature of up to 122°F (50°C) and wet bulb temperature up to 78.8°F (26°C).
Occasional excursions in operating conditions between the rated MTBF conditions and the maximum drive operating conditions may occur without significant impact to the rated MTBF. However continual or sustained operation beyond the rated MTBF conditions will degrade the drive MTBF and reduce product reliability.

5.2.2 Preventive maintenance

No routine scheduled preventive maintenance is required.

5.2.3 Hot plugging the drive

When a disk is powered on by switching the power or hot plugged, the drive runs a self test before attempting to communicate on its’ inte rfac es. W hen t he sel f tes t comp let es su cces sfu lly, the dr ive in iti ate s a Link R ese t star tin g wit h OOB. An at tach ed de vice s hould respond to the link reset. If the link reset attempt fails, or any time the drive looses sync, the drive initiated link reset. The drive will initiate link reset once per second but alternates between port A and B. Therefore each port will attempt a link reset once per 2 seconds assuming both ports are out of sync.
If the self-test fails, the drive does not respond to link reset on the failing port. Note. It is the responsibility of the systems integrator to assure that no temperature, energy, voltage hazard, shorting of PCBA to
ground, or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static electricity from the drive carrier prior to inserting it into the system.
Caution. The drive motor must come to a complete stop prior to changing the plane of operation. This time is required to insure data
integrity.

5.2.4 S.M.A.R.T.

S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended to recognize conditions that indicate imminent drive failure and is designed to provide sufficient warning of a failure to allow an application to back up the data before an actual failure occurs.
Note. The drive’s firmware monitors specific attributes for degradation over time but can’t predict instantaneous drive failures. Each monitored attribute has been selected to monitor a specific set of failure conditions in the operating performance of the drive and the
thresholds are optimized to minimize “false” and “failed” predictions.
Controlling S.M.A.R.T.
The operating mode of S.M.A.R.T. is controlled by the DEXCPT and PERF bits on the Informational Exceptions Control mode page (1Ch).
Use the DEXCPT bit to enable or disable the S.M.A.R.T. feature. Setting the DEXCPT bit disables all S.M.A.R.T. functions. When enabled, S.M.A.R.T. collects on-line data as the drive performs normal read and write operations. When the PERF bit is set, the drive is considered to be in “On-line Mode Only” and will not perform off-line functions.
Applications can measure off-line attributes and force the drive to save the data by using the Rezero Unit command. Forcing S.M.A.R.T.
resets the timer so that the next scheduled interrupt is in one hour.
Applications can interrogate the drive through the host to determine the time remaining before the next scheduled measurement and data
logging process occurs. To accomplish this, issue a Log Sense command to log page 0x3E. This allows applications to control when S.M.A.R.T. interruptions occur. Forcing S.M.A.R.T. with the RTZ command resets the timer.
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 13
Performance impact
S.M.A.R.T. attribute data is saved to the disk so that the events that caused a predictive failure can be recreated. The drive measures and saves parameters once every hour subject to an idle period on the drive interfaces. The process of measuring off-line attribute data and saving data to the disk is interruptable. The maximum on-line only processing delay is summarized below:
Maximum processing delay
Fully-enabled delay DEXCPT = 0
S.M.A.R.T. delay times 70 milliseconds
Reporting control
Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to the reporting method. For example, if the MRIE is set to one, the firmware will issue to the host an 01-5D00 sense code. The FRU field contains the type of predictive failure that occurred. The error code is preserved through bus resets and power cycles.
Determining rate
S.M .A. R. T. m oni to rs th e rat e at wh ich e rro rs oc cu r and s ign als a p red ict iv e fai lur e if th e rat e of de gr ade d err ors i ncr eas es t o an unacceptable level. To determine rate, error events are logged and compared to the number of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.
S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.
Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to b e acceptable. In either case, the interval and failure counters are reset and the process starts over.
Predictive failures
S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firmware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accomplish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the predictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter.
There is a separate Failure History Counter for each attribute.

5.2.5 Thermal monitor

Enterprise Performance 15K HDD and Enterprise Turbo SSHD drives implement a temperature warning system which:
1. Signals the host if the temperature exceeds a value which would threaten the drive.
2. Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.
A temperature sensor monitors the drive temperature and issues a warning over the interface when the temperature exceeds a set
threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the specified limit in compliance with
the SCSI standard.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting
Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
Table 1 Temperature Log Page (0Dh)
Parameter Code Description
0000h Primary Temperature Never 0001h Reference Temperature Never
[a]. Do not reset the log parameter. [b]. Do not make any requested changes in any field in any log parameter in any log page.
Resettable or Changeable
[a] [b] [a] [b]
Support Required
Mandatory Optional
SEAGATE ENTERPRISE PERFORMANCE 15K HDD V5 AND TURBO SSHD V2 PRODUCT MANUAL, REV. B 14
Loading...
+ 46 hidden pages