Mac or PC ........................................................................41
REPLACING THE BATTERY.............................42
ACTION SERIAL NUMBER ...............................43
CE CERTIFICATION..............................................43
CARE AND MAINTENANCE ............................43
CERTIFICATE OF WARRANTY .......................44
Page 3
ACTION
ACTION MANUAL
Congratulations on your purchase of a SEAC diving computer.
The SEAC ACTION dive computer is a technologically advanced device
designed and manufactured to provide all the information that every diver needs.
Periodically check www.seacsub.com for any updates to this manual.
GENERAL WARNINGS
• WARNING!
Read the user manual fully before using the SEAC computer.
Using the computer incorrectly will void the warranty and can
permanently damage the computer.
• WARNING!
Only use the dive computer after you have read all sections of the
instruction manual and you have understood how it works.
• WARNING!
The dive computer is not a substitute for diver training and should only be
used by divers who have been properly trained and who have earned the
appropriate license issued by a Certified Teaching Association.
• WARNING!
The computer does not replace an understanding of decompression
tables, which divers must always carry with them for safety, along with a
depth gauge and a dive watch.
• WARNING!
The SEAC computer is an auxiliary device during a dive. Therefore, it is
crucial that each diver always carry with them a suitable table that will
enable them to conduct the decompression phase if the unit should
malfunction.
3
Page 4
• WARNING!
Freediving entails risks of syncope, taravana, pulmonary edema, and
hemoptysis, while diving with a respirator involves risks related to
decompression sickness, oxygen toxicity, nitrogen narcosis, and in general
other risks connected to the dive itself: even a thorough reading of this
manual and use of the instrument does not exclude potential dangers.
• WARNING!
The computer cannot take into account individual physiological changes
that can change from one day to the next. For this reason it's good
practice to use the device conservatively and cautiously, remaining within
the limits shown by the computer in order to minimize the risks.
• WARNING!
It is strictly forbidden to freedive in the 12 hours after diving with scuba
equipment!
Violating this rule could considerably increase the risk of decompression
sickness.
• WARNING!
Do not share one computer between two divers during the dive. Every
diver must have their own instrument to provide information and save
only that diver's data.
• WARNING!
Before diving, you must check the battery charge. Do NOT dive if the low
battery icon is shown on the display. Always check that the display shows
no signs of any malfunction and that it is clearly legible.
The Battery icon on the display has 2 segments:
Segment 1: Battery Outline ==> Battery lower than Minimum Voltage (do
not dive).
Segment 2: First Bar from the bottom ==> Battery lower than 2.1V (Low
level. The voltage could plummet during a dive in especially cold water).
4
Page 5
ACTION
• WARNING!
Always check that the settings are correct for your dive, and don't allow
anyone else to tamper with your computer before the dive. If it has been
tampered with by another person, check that your settings are correct.
• WARNING!
It is important to keep in mind that your body undergoes changes, even
daily changes, that a computer cannot account for. If your physical
condition is not excellent, or if you feel any physical problems, do not dive!
• WARNING!
The normal functions of the product could be disturbed by strong
electromagnetic interference.
In this case, simply reboot the product to restore normal function,
following the instructions provided in this manual (see “Reset”) and use
the product in another position.
• WARNING!
Strictly avoid pressing on the side grill of the sensor with your fingers,
especially if the sensor compartment is full of water, because this could
distort the measurement of zero, and could therefore result in an incorrect
measurement of depth during the next dive, with the consequence that
the NDL/Deco data may also be inaccurate.
In DIVE mode, if you notice a measurement of anything other than zero
on the surface, you need to reset the device to zero out the sensor
measurement (see the instructions and warnings on using the RESET
further on in this manual) or wait a few hours for the system to reestablish
the correct zeroing.
5
Page 6
HARDWARE
Type:Wristwatch computer.
Screen:LCD Icons/Segments/Transflective matrix
Backlighting:LED, user-adjustable.
Battery:CR2450, non-rechargeable, 3V 600mAh,
Butt ons:4
Alarm Type:Audible and visual.
PC/Mac connection:Serial via USB with special dedicated cable
Maximum operating depth100 meters/328 ft
6
with user-adjustable contrast.
user-replaceable (we strongly recommend
that you have this done at an authorized
SEAC center, also replacing the O-ring in the
battery compartment).
(optional).
Page 7
ACTION
APPLICATION SOFTWARE
Updates:Supported through serial port via USB.
Factory mode:Supported to save energy, can be set by
Auto Recovery:Automatic reboot if software locks.
Restore:Manual, though combination of buttons\time.
Decompression Algorithm: Buhlmann ZHL-16C for Air/Nitrox.
Levels of conservatism:Yes, based on Gradient Factor.
After a dive in SCUBA / GAUGE mode, the Computer stays on the SCUBA /
GAUGE screen for 10 minutes after emerging, and therefore you cannot access
the menu and submenu.
After a dive in FREE mode, the Computer stays on the FREE screen for 15 minutes
after emerging, and therefore you cannot access the menu and submenu.
After a dive in SCUBA or GAUGE mode, FREE mode is inhibited and is not
accessible for the next 12 hours.
After a dive in GAUGE mode, because tissue saturation is calculated assuming
that the dive uses mix number 1, SCUBA mode is available.
After a dive in GAUGE mode, the Desaturation and NoFly times are updated with
the new tissue saturation data. In particular, the NoFly time is set to 24 hours,
as a precaution in favor of safety, regardless of the type of profile that was run.
After a dive in FREE mode, the residual Desaturation and NoFly time, if any
existed before the dive in FREE mode, will be left unchanged.
8
Page 9
ACTION
If you Reset the Settings, the Computer will automatically start in SCUBA mode.
When the Computer is in Watch mode and you dive without manually
entering dive mode (using the LR button), the Computer will automatically
launch the mode you selected most recently.
Decompression Algorithm
The computer uses the original Buhlmann ZHL-16C Decompression Algorithm,
unmodified.
Levels of Protection
The Action allows you to select 6 levels of protection (conservatism), from 0 to 5.
Level 5 provides the maximum protection.
Repetitive Dives
All dives taken within a 48-hour period are considered “Repetitive Dives”.
Dives with Surfacing
“Surfacing” is defined as the situation in which the diver emerges after having
begun a Scuba type of dive.
Surfacing ends if the diver dives again within a period of fewer than ten minutes
from emerging; beyond this limit the current dive is considered ended.
If you change mixes during the dive and dive again within the 10 minute
Surfacing time, the mix in use is reset to the starting mix .
NDL - NonDecompressionLimit
The “NonDecompressionLimit” is defined as the time that remains at the
current depth and breathing the mix that is currently set to avoid requiring
decompression.
To avoid requiring decompression stops, the time required for the ascent must
be subtracted from the NDL.
9
Page 10
Safety Stop
The user can set both the depth and the duration of the Safety Stop.
NOTES:
a) The Safet y Stop is calculated and proposed if the maximum depth reached is
greater than 12 meters/40 ft.
b) The Safety Stop is shown when the diver comes within 9 meters/30 ft of the
surface.
c) The countdown begins if the diver arrives within +2 meters/+6.5 ft and
-2 meters/-6.5 ft of the stop depth set. For example: If the stop set is 5
meters/16.5 ft, the countdown starts between 7 meters/32 ft and 3 meters/10
ft. In this case then, if you go to a depth of less than 3 meters/10 ft., the stop
will be canceled.
d) The Safet y Stop is not calculated and is not proposed if at least one deco stop
is underway within 9 meters/30 ft from the surface.
e) If the current dive includes one or more decompression stops, and if these
decompression stops are cleared during the ascent (before reaching 9
meters/30 ft) because of a very slow ascent or in any case a multilevel dive,
then the Safety Stop is calculated and proposed at the time and duration set
by the user.
f) If the Diver again exceeds a depth of 9 meters/30 ft after having performed
the stop, the Safety Stop is recalculated and reproposed in accordance with
the rules described above.
g) If the Diver descends to a depth greater than 9 meters/30 ft during the
countdown, it will be reset and recalculated according to the rules above.
10
Page 11
ACTION
Deep Stop
If the Deep Stop is enabled, it is calculated as a 2-minute-and-30-second stop at
half the maximum depth reached if the following conditions are met:
- Maximum depth reached greater than 18 meters/59 ft.
- There are no mandatory decompression stops during the ascent.
NOTES:
a) The Deep Stop is displayed at +5 meters/+16.5 ft and -3 meters/-10 ft from
the calculated stop. In other words, if the Deep Stop is at 20 meters/66 ft, it is
displayed in the range from 17 meters/56 ft to 25 meters/82 ft.
b) The countdown to the stop begins when the diver arrives in a range of +2
meters/+6.5 ft and -2 meters/-6.5 ft from the calculated stop depth. For
example: if the stop is calculated at 25 meters/83 ft, the count down is
performed in the range of 27 meters/89 ft to 23 meters. If the Diver moves -2
meters/-6.5 ft from the stop depth (meaning lower than 23 meters/75.5 ft), it
is canceled. If the Diver arrives within 27 meters/89 ft - 31 meters/102 ft, the
countdown is suspended.
c) If the Diver again exceeds the stop depth by more than 6 meters/20 ft (or
in any case, 18 mt/59 ft), the stop will be recalculated according to the rule
above.
TTS
The “TTS” is the total time to surface, and accounts for the entire time for
executing mandatory decompression stops (calculated according to user
settings) and the ascent time (calculated at a constant velocity of 9m/min - 30
ft/min).
11
Page 12
Ascent Speed Alarm
The standard maximum ascent speed is set at 9 meters/minute - 30 ft/min.
The Ascent Speed Alarm indicates the ascent speed using icons, and is only
available in SCUBA mode.
The Ascent Rate icon consists of 3 arrows.
The Ascent Speed Alarm is both visual and audible.
The visual alarm cannot be disabled.
Users can disable the audible alarm.
The rules for the Ascent Speed Alarm are:
- Speed <= 3m/min- 10ft/min: No indication
- 3m/min- 10ft/min < Speed <= 6m/min-20 ft/min: One arrow
- 6m/min -20ft/min < Speed <= 9m/min- 30ft/min: Two arrows
- 9m/min- 30ft/min < Speed <= 12m/min 40ft/min: Three arrows
The “MOD” defines the maximum operating depth for the mix in use and is
calculated as a function of the real surface atmospheric pressure and the PpO2
(oxygen partial pressure) set for the mix in use.
The alarm for Exceeding the MOD is visual and audible.
The visual alarm cannot be disabled; this is indicated by the field for the current
depth flashing.
Users can disable the audible alarm.
Both alarms are activated as soon as the MOD is exceeded.
12
Page 13
ACTION
Deco Violation Alarm
The Deco Violation Alarm will trigger when the Diver reaches a depth less than
(in absolute value) that set by the mandatory decompression stop.
The Deco Violation Alarm is visual and audible.
The visual alarm cannot be disabled; this is indicated by the field for the current
depth flashing.
Users can disable the audible alarm.
Both alarms will trigger when the Diver reaches a depth less than (in absolute
value) 0.5 meters/1.6 ft of the mandatory decompression stop indicated.
The alarm does not trigger for Deep Stops and Safety Stops, because these
stops are not mandatory.
Locking the Computer
If decompression stops are omitted, rather than immediately switching to lock
mode like other dive computers, Action applies penalty points that eventually
result in locking the SCUBA mode upon reaching 150 points.
The penalty points are assigned as follows:
- 5 points for every 5 seconds, if the diver's current depth is lower than one
meter/3 ft from the stop level indicated.
- 10 points for every 5 seconds, if the diver's current depth is lower than two
meters/6.5 ft from the stop level indicated.
This means that for an ongoing violation, Action will enter lock mode after about
2 minutes at a depth lower than one meter/3 ft, and after about 1 minute if the
stop depth violation is 2 meters/6.5 ft, naturally only if the violation is occurring
in the direction of the surface.
Once it reaches 150 points, the computer switches to lock mode.
The diver will be notified during the dive with an “Alert” icon and a message,
alternating with information about remaining decompression, indicated by the
words “WARNING DECO VLT”.
Decompression will still be calculated until the end of the dive where anticipated
by the Buhlmann mathematical model.
13
Page 14
• WARNING:
two repetitive dives with surface times of fewer than 10 minutes are
considered to be a single dive.
If the mandatory decompression stop is violated during the dive and the
computer switches to lock mode, SCUBA mode will not be available for 18 hours.
After this period, the counter to put the watch out of service will be reset at the
beginning of the next dive.
If you begin a new dive in SCUBA mode before this interval, when the computer
is still in lock mode, the “Alert” icon and the message reading “WARNING DECO VLT” will be displayed for the entirety of the dive, without alternating with
the decompression data.
Whenever the computer is locked, the NoFly and Desaturation times are not
shown.
No-fly time
NoFly time is calculated according to the following rules:
- 12 hours for a single dive (no dive in the preceding 48 hours) within the nodecompression limits.
- 18 hours for repetiti ve dives without decompression on the same day or multiday.
- 24 hours for repetitive dives with decompression on the same day or multiday.
For more information, consult the "No-fly Time" section in the "After the Dive"
chapter.
Desaturation Time
The tissue Desaturation Time is calculated immediately at the end of the dive.
It is defined as the time necessary for the nitrogen inert gas pressure to be lower
than the Partial pressure of nitrogen (PpN2) breathed, increased by a tolerance
factor.
For more information, consult the "Desaturation Time" section in the "After the
Dive" chapter.
14
Page 15
ACTION
Permitted Altitude Indicator
The Permitted Altitude is calculated and updated after dives as follows:
The Permitted Altitude icon is shown in Watch mode, and is managed as follows:
- Max 1000 m/3290 ft: 1 triangle on.
- Max 2000 m/6580 ft: 2 triangles on.
- Max 3000 m/9870 ft: 3 triangles on.
- No Limit: icon o (not displayed).
Battery/Run-time
The computer is powered by a 3V CR2450 MAXCELL Asia Product battery with
a nominal capacity of 600 mAh.
The battery capacity varies based on environmental conditions.
The battery run-time varies depending on how the product is used and which
functions are used.
The run-time drops noticeably when backlighting, audible alarms, PC connections,
and updates are used.
When the Software Application is launched, a test of the battery under load
is performed. When this happens you may notice the backlighting turn on
temporarily. If the battery voltage under load is less than 2.0V (Minimum
Voltage), the device will remain o or locked, on a screen with the words “LOW BAT ”. In some cases you may see a continuing Reset for a few cycles.
If the battery voltage under load is below 1.8V (Start Voltage), the backlighting
may remain on continuously until the computer battery is completely drained. In
this case, the computer will not turn on at all and no text appears on the LCD.
The Battery icon on the display has 2 segments:
Segment 1: Battery Outline ==> Battery lower than Minimum Voltage (do not dive).
Segment 2: First Bar from the bottom ==> Battery lower than 2.1V (Low level.
The voltage could plummet during a dive in especially cold water).
Theoretical run-time, linked strictly to the quality of the battery installed:
15
Page 16
Mode
Factory Mode8.4
Watc h3.0
100 dives/year2.9
200 dives/year2.7
300 dives/year2 .1
The data indicated above:
refer to a new battery of recent manufacture (and therefore not subject to
excessive auto-draining).
refer to use at 25°C/77°F.
refer to use that does not entail direct exposure to sunlight.
do not include consumption by backlighting and audible alarms.
Theoretical average run-time
(years)
Time and Time Zones
The computer can handle two time zones:
Local Time:Time at the user's location.
Home Time:The time at home.
The reference time is always the LOCAL time, and is indicated in the center of
the Watch screen, or in secondary screens during SCUBA/GAUGE/FREE dives.
The Home time can only be changed by editing the value of the “UTC HOME”
time zone in the “SYS SET” menu.
If “UTC LOC” and “UTC HOME” are the same, only one time is shown on the
Watch screen.
If the two parameters do not match, the LOCAL Time is shown in the center of
the screen (the date indicated refers to this Time), while the HOME time is shown
on the lower right.
If the date for each of the two Times is dierent, the date oset from the HOME
Time will be shown on the lower right: “+1 / -1”.
16
Page 17
ACTION
Planner
Action's Planner lets you simulate and plan a dive, displaying the NDL time
(within non-decompression limits) depending on the depth set.
The Planner allows you to plan Air/Nitrox with NDL only, meaning within the
non-decompression limits, and therefore requiring no decompression time.
The input data (mix, Max PpO
various submenus (“MIX”, “DIVE SET”) and are used to calculate the NDL.
The calculated NDL accounts for descent performed at 18 meters/minute 59 ft/
minute.
The calculated NDL does not include the time required for the ascent.
In Planning mode, you can only change the dive depth and the surface time.
The NDL Time display is updated immediately whenever the dive depth or
surface interval is changed.
Depths greater than 45 meters/150 ft cannot be entered.
, and level of conservatism) are entered in the
2
Divelogger
Dive data can be downloaded to be saved, viewed, and processed. The
software for both Windows 10 and Mac is available for free download on the
website www.seacsub.com. However, to connect the Action to a PC you need
a special USB cable that can be purchased separately.
KEYS NOMENCLATURE
HL
LL
HR
LR
17
Page 18
MENU AND SETTINGS
Methods for entering all the settings menus listed below:
• From the “watch” display, press the LL (Mode) key once. LOG will appear on
the display. From here, press the LR button multiple times (RESET/-) until the
name of the desired function appears on the display. At this point, to enter
the corresponding setting/editing submenu, confirm your choice with the LL
button (Mode).
• From any position you're in, press the LL (Mode) and LR (Reset/-) buttons at
the same time to return to the main screen (watch).
FROM ANY
MODE
User Data Memory:
The computer settings data that the users enters/edits, the tissue data, and the
current date/time are saved every 15 minutes.
Therefore, if you change the battery, the data that is restored on reboot are at
most 15 minutes old, so the time will only need to be adjusted manually by a
few minutes.
18
Page 19
ACTION
LAYOUT CHRONO SURF WATCH MODE
Stopwatch
The stopwatch can only be activated from WATCH, GAUGE DIVE, and FREE
DIVE modes, and not from SCUBA DIVE mode.
To switch to the stopwatch function, press the HR button from one of the modes
listed above.
19
Page 20
Logbook
The computer memory intended for saving SCUBA/GAUGE/FREE dives taken
is limited to:
- approx. 40 hours (Scuba/Gauge mode). Sampling time every 5 seconds.
- approx. 18 hours (Freedive mode). Sampling time every 2 seconds.
If the memory becomes completely full, the oldest dives will be deleted to make
room for new dives.
When you enter the “Logbook” submenu, you will see:
- at the top: the duration of the dive, the max depth, and the mode icon (OC,
Scuba, or Gauge).
- in the center: No. of the dive displayed in the memory, and date and time of the
dive.
- at the bottom: the temperature and average depth of the dive.
When you press the LL button on the lower left, in place of the temperature you
will see the oxygen percentage set for that dive.
MIXES
Action manages up to two gas mixes with oxygen percentages (O2) from 21% to
99% and oxygen partial pressure (PpO2) from 1.2 to 1.6 bar.
When you enter the “MIX1” submenu, the number of the oxygen percentage for
this gas mix will flash. This can be set by using the HR (+) and LR (-) buttons.
Fields for setting O
MOD, meaning the maximum operating depth for the O2 percentage selected
and for the PpO2 selected, which can be set by pressing the LL button (Mode)
once:the PpO2 number will flash, and you can select the desired value using
the HR (+) and LR (-) buttons. Setting range from 1.2 to 1.6 bar in increments
of 0.5 bar. When the PO2 is also selected, press the LL button once to move to
the “MIX2” screen. Using the same methods used for MIX1, set the O2 and PO2
percentage. Then you can press the LL button (Mode) once to activate MIX2 by
selecting ON or OFF with the HR or LR buttons.
20
from 21% to 99%. The upper right of the screen shows the
2
Page 21
ACTION
LAYOUT MENU: MIX
• WARNING!
Changing these settings requires special training on the use of enriched
breathing mixes. If you have not received this training, do not dive with
enriched breathing mixes!
Do not dive using breathing mixes other than those set in your diving
computer. Using mixes other than those set makes it impossible to
calculate the decompression correctly!
21
Page 22
Dive parameters (DIVESET)
When you have entered the “MODE” submenu, use the HR (+) or LR (-) buttons
to select the type of dive: using an open-circuit respirator (OC) "SCBA", or
in Instrument/Gauge mode (depth gauge/timer only) "GAGE", or again for
"FREE" dives. Confirm your choice of dive t ype with the LL button (Mode). The
appropriate icon (OC, GAUGE, or FREE) will turn on at the top of the screen
during the dive to display your choice. The “SFT LEV” screen will appear with a
flashing number. On this screen you can select the desired level of safety, from
0 to 5. In other words, you can choose whether you prefer your Action to be
more or less conservative when calculating the safety or decompression curve.
Selecting 5 means that you want to be as conservative as possible, while 0 is
the minimum value.
Once you have selected the value you want, press the LL button once to switch
to the S.S.TIME screen, where you can set the Safety Stop time in minutes,
meaning the safety stop to take before emerging. Values can be set with the HR
and LR buttons from 0 (no Safety Stop) to 5 minutes.
Pressing the LL button will switch you to the page for selecting the Safety Stop
depth: S.S.DPT. This can be set from 3 to 6 meters in depth using the HR and
LR buttons.
Press the LL button once. The DEEP STP screen will appear, where you can
select ON-OFF to decide whether or not to activate the Deep Stop. If you select
ON, Action will calculate the depth and time automatically. Confirm your choice
by pressing the LL button once.
The WAT ER screen will appear, in which you can select the water type, either
sea (SLT) or fresh (FRH). Confirm your choice with the LL button, or press the LL
and LR buttons at the same time to return to the main screen.
22
Page 23
ACTION
LAYOUT MENU: DIVE SET
• WARNING!
For safety reasons, it is NOT possible to set FREE mode as the main mode
unless 12 hours have elapsed since the most recent SCUBA or GAUGE
dive.
Dive planner (PLANNER)
When you enter this SET, first the depth setting field flashes. This can be
changed using the RH (+) and RL (-) buttons. In Planner mode, you can only
change the depth of the dive.
You cannot enter depths greater than those permitted by the MOD for the mix
set (shown at the bottom of the screen).
The input data (mix, Max PpO
various submenus (“MIX”, “DIVE SET”) and are used to calculate the NDL.
, and level of conservatism) are entered in the
2
23
Page 24
Alarms (ALARMS)
LAYOUTMENU: ALARMS
• WARNING!
Action allows you to suppress audible alarms. However, we recommend
that you only make this choice after careful consideration and with
full awareness. Audible alarms are an important warning for possible
violations and behavior errors during the dive that could result in
accidents, even serious ones.
All the audible alarms can be enabled (ON) or disabled (OFF) using the HR
buttons or LR and confirmed using the LL button.
• WARNING!
Except for special situations, we do not recommend disabling audible alarms.
DECO VLT: decompression stop violation alarm signaled by the Action.
MOD VLT: alarm indicating violation of maximum operating depth permitted for
the gas mix in use.
ASC SPD: excessive ascent speed alarm.
Display
BACKLIGHT BRIGHTNESS LEVEL (BKL LEV):Levels available from 0 to 3 (if
you select “0” backlighting will not activate)
BKL TIME: duration of the backlight in seconds in AUTO mode; selectable from
2” to 60”.
BKL MODE: 3 modes:
AUTO by choosing this option, the backlight will remain on for the preset time.
MAN: the backlighting will be turned on/o manually using the HL button.
24
Page 25
ACTION
LAYOUT MENU: DISPLAY
In watch mode, the backlighting will turn o automatically after 600 seconds.
DIVE: by activating this option, the backlighting will activate automatically
when the dive beings and will remain on for the full duration of the dive.
• WARNING:
intense use of the backlight will consume the battery faster, so it will not
last as long.
CONTRAST: 5 display contrast levels can be selected
For each mode, set the choice using the HR (+) and LR (-) buttons and confirm
with the LL button (Mode) and move to the next selection. Press LL and LR at
the same time to return to the main view.
System Settings (SYS SET)
The settings below are possible in this mode:hour/minute (TIME), date (DATE),
UTC second time zone (UTC LOC), UTC primary time (UTC HOME), 12/24 hour
format (FORMAT), unit of measure meters MTR or feet IMP (UNITS).
The reference time is always the LOCAL time, and is indicated in the center of the
watch screen, or in secondary screens SCUBA/GAUGE/FREE during the dive.
The Home time can only be changed by editing the value of the “UTC HOME”
time zone in the “SYS SET” menu.
If “UTC LOC” and “UTC HOME” are the same, only one time is shown on the
watch screen.
If the two parameters do not match, the LOCAL time is shown in the center of
the screen (the date indicated refers to this time), while the HOME time is shown
in the lower right.
If the date for each of the two times is dierent, the date oset from the HOME
25
Page 26
time be shown on the lower right: “+1 / -1”.
For each mode, set the choice using the HR (+) and LR (-) buttons and confirm
with the LL button (Mode) and move to the next selection. Press LL and LR at
the same time to return to the main view.
PC Mode
To connect your Action to a PC or Mac to link with the Dive Logger software and
download your data, your Action must be set to this mode before you connect it
to the computer with the special USB cable (optional).
Info mode
The Info screen shows:the name of the model, the serial number (which is also
laser engraved on the back of the case), and the firmware version installed.
Reset
Resetting tissues and user settings is a risky procedure, especially if the diver is
taking repetitive dives. Therefore you have to confirm twice before a reset will
be performed:
Enter a four-digit security code. The security code is “5555”.
If the code entered is valid, before performing a reset, you will need to confirm
the operation.
If the operation is successful, the message “RESET DONE” will appear.
• WARNING!
On the watch screen, the icon of the “WARNING” symbol will appear on
the lower left to alert the diver and remind them that the computer was
reset. This symbol will disappear after the next SCUBA/GAUGE/FREE dive.
• WARNING! DANGER!
Do NOT perform the tissue saturation reset if the device will be used soon
by the same person!
This can lead to the risk of accidents, including fatal ones.
The tissues can only be reset if the Action will be used by a person who
has not taken any dives in the previous 48 hours.
26
Page 27
ACTION
LAYOUT MENU: OFF
OFF (FACTORY MODE)
“Factory Mode” is a special function for reducing energy consumption to a
minimum and helping the battery last as long as possible.
The computer will be “o”, while still keeping all settings, storage, and time
calculation in memory.
On the screen that reads “EXECUTE”, you can confirm the choice to switch the
Action OFF using the LR button (YES) or reject the selection with the LL button
(NO).
To exit “Factory mode” and reactivate the Action, press the LL and HR buttons
at the same time.
27
Page 28
USER SETTINGS RANGE
MENU PARAMETERRANGEDE FAU LTUNITNOTES
MIX 1 O2%21-9921%
MIX 1 PPO
MIX 2 O
MIX
MIX 2 PPO
MIX 2 ON/
MENU PARAMETERRANGEDE FAU LTUNITNOTES
OFF
MODESCUBA/
SFT LEVEL0-50Level of
S.S. TIME0-53Min
DIVE SET
S.S DPT3-65m/ft
DEEP STPON/OFFOFF
WATERSALT/
MENU PARAMETERRANGEDE FAU LTUNITNOTES
DECO VLTON/OFFONDecompression
MOD VLTON/OFFONViolation of
ALARMS
ASC SPDON/OFFONAscent rate
28
1.20-1.601.40bar
2
%21-9950%
2
1.20-1.601.60bar
2
ON/OFFOFF
GAUGE
SCUBA
/FREE
FRESH
SALT
conservatism of
the ALGORITHM
stop violation
maximum
operating depth
for breathed mix
violation
Page 29
ACTION
MENU PARAMETERRANGEDE FAU LTUNITNOTES
BKL LEV0-33
BKL TIME2-603Seconds
BKL MODEAUTO/
DISPLAY
CONTRAST0-50
MENU PARAMETERRANGEDE FAU LTUNITNOTES
MAN/DIVE
AUTO
TIME-DAT E--
UTC LOC-12:00 /
UTC HOME-12 :00 /
SYS SET
FORMAT24 -1224
UNITSMETRIC/
+14:00
+14:00
IMP
+1:00Rome Time Zone
+1:00Rome Time Zone
METRIC
ACTION DURING THE DIVE
• WARNING!
This manual does NOT replace adequate training!
• WARNING:
Before diving, always check that the dive mode has been set correctly for
the dive you are about to take (SCUBA-OC, Gauge, or Free) by pressing
the LR button from watch mode and checking that the icon showing at
the top is the correct one, or you can check and make a selection in the
“DIVESET” set.
29
Page 30
• WARNING!
This check is important, because if you begin a dive in the wrong mode
(for example, FREE instead of OC-SCUBA), firstly you will not have the
correct information which could compromise your safety if you continue
the dive, and even if you resurface immediately you need to wait out the
time planned for the end of the dive, meaning 10 minutes for a dive set to
SCUBA/GAUGE and 15 minutes for a dive set to FREE.
If you do not switch to dive mode manually by pressing the LR button once
from watch mode, the Action will automatically activate dive mode when you
descend past 1.5 meters.
SCUBA (OC) DIVE
• WARNING!
This manual does NOT replace adequate training.
• WARNING!
Do not dive with the Action if the battery charge is low, meaning with only
Segment 1 lit:Battery Outline ==> Battery lower than Minimum Voltage.
When only the first block from the bottom is lit, this means a low battery
charge. Avoid diving in especially cold water, because the voltage could
plummet.
30
Page 31
1. NDL Dive
LAYOUTMODALITA' SCUBA
1)NDL
LAYOUTMODALITA' SCUBA
1)NDL
1)NDL
Screen 1Data displayed:
Dive time – current depth
NDL time
Oxygen percentage of the current mix – Maximum depth
Screen 2
Screen 3
Screen 4
reached
Dive time – current depth
NDL time
Oxygen percentage of the current mix – PpO
Dive time – current depth
NDL time
Current temperature – Average depth
Dive time – current depth
NDL time
% value of CNS O2 - Current time
ACTION
2
31
Page 32
2. Deep Stop
LAYOUTMODALITA' SCUBA
1)NDL
2) SAFETYSTOP
3) DEEPSTOPin NDL
LAYOUTMODALITA' SCUBA
1)NDL
2) SAFETYSTOP
3) DEEPSTOPin NDL
1)NDL
2) SAFETYSTOP
3) DEEPSTOPin NDL
If the Deep Stop function is set, it will be displayed 5 m/16.5 ft before the actual
depth required in the central line on the display, and will be removed (if not
performed) 5 m/16.5 ft after the depth required.
DS 1 ScreenData displayed:
Dive time – current depth
Deep Stop depth – Deep Stop time
Oxygen percentage of the current mix – Maximum depth
reached
DS 2 Screen
DS 3 Screen
DS 4 Screen
Dive time – current depth
Deep Stop depth – Residual Deep Stop time.
Oxygen percentage of the current mix – PpO
Dive time – current depth
Deep Stop depth – Residual Deep Stop time.
Current temperature – Average depth
Dive time – current depth
Deep Stop depth – Residual Deep Stop time.
% value of CNS O2 - Current time
2
32
Page 33
ACTION
LAYOUTMODALITA' SCUBA
1)NDL
2) SAFETYSTOP
LAYOUTMODALITA' SCUBA
1)NDL
2) SAFETYSTOP
1)NDL
2) SAFETYSTOP
3. Safety Stop
If the Safety Stop has been set (recommended), it will be shown on the
display in the center line of the computer during the ascent beginning at a
depth of 9 meters. The safety stop is automatically omitted if the dive requires
decompression.
SS 1 ScreenData displayed:
Dive time – current depth
Safety Stop depth – Safety Stop time
Oxygen percentage of the current mix – Maximum depth
SS 2 Screen
SS 3 Screen
SS 4 Screen
reached
Dive time – current depth
Safety Stop depth – Residual Safety Stop time.
Oxygen percentage of the current mix – PpO
Dive time – current depth
Safety Stop depth – Residual Safety Stop time.
Current temperature – Average depth
Dive time – current depth
Safety Stop depth – Residual Safety Stop time.
% value of CNS O2 - Current time
2
33
Page 34
4. DECO Dive
LAYOUTMODALITA' OC PRELIMINARE
LAYOUTMODALITA' OC PRELIMINARE
4)DECO
4)DECO
4)DECO
Screen 1Data displayed:
Screen 2
Screen 3
Screen 4
Dive time – current depth
TTS (total time to surface) – first stop depth – DECO time
of the first stop.
Oxygen percentage of the current mix – Maximum depth
reached
Dive time – current depth
TTS (total time to surface) – first stop depth – DECO time
of the first stop.
Oxygen percentage of the current mix – PpO
Dive time – current depth
TTS (total time to surface) – first stop depth – DECO time
of the first stop.
Current temperature – Average depth
Dive time – current depth
NDL time
% value of CNS O2 - Current time
2
34
Page 35
ACTION
4)DECO
4)DECO
6) CAMBIO MIX
5. Mix change during the dive
If a second mix is also set in addition to the bottom mix, Action will alert the
user at best time to make the change by flashing the %O
the main dive screen.
To confirm the mix change, select YES by pressing the LR button. To reject the
change, select NO with the LL button.
Once the change is made, the new Mix will be displayed in the lower left corner.
When it is possible to switch to the second mix, the field
on the lower left that usually
displays the O2% of the current mix will begin to flash.
You can only access the mix change menu when this field
is flashing. Press the LL button to confirm.
Dive time – current depth
Proposed mix change
Confirm or reject with the corresponding LR or LL
buttons
on the lower left of
2
35
Page 36
DIVE IN GAUGE MODE
LAYOUTMODALITA' GAUGE
CHRONO
• WARNING!
This manual does NOT replace adequate training.
• WARNING!
Adequate training is required to use Action in GAUGE mode!
In GAUGE mode, Action does not calculate NDL or decompression. It only
shows the following information on two screens:
Dive time – current depth
Average depth
Temperature – maximum depth reached during the
current dive
Dive time – current depth
Average depth
Temperature – current time
36
Page 37
ACTION
LAYOUTMODALITA' FREE
CHRONO
DIVE IN FREE MODE
• WARNING!
This manual does NOT replace adequate training.
• WARNING!
For safety reasons, Free mode cannot be selected unless at least 12 hours
have passed since the most recent dive in OC or GAUGE mode.
In FREE mode, Action provides the information a freediver needs. Action does
not provide the minimum suggested surface time between one dive and the next.
The information is displayed on two screens, and is the following:
Dive time – current depth
Surface time; the timer begins as soon as the dive starts
Temperature – maximum depth reached during the
current dive
Dive time – current depth
Surface time; the timer begins as soon as the dive starts
Temperature – current time
37
Page 38
AFTER THE DIVE
After a dive in SCUBA / GAUGE mode, the Computer stays on the SCUBA /
GAUGE screen for 10 minutes after emerging, and therefore you cannot access
the menu and submenu.
After a dive in FREE mode, the Computer stays on the FREE screen for 15 minutes
after emerging, and therefore you cannot access the menu and submenu.
After a dive in SCUBA or GAUGE mode, FREE mode is inhibited and is not
accessible for the next 12 hours.
After a dive in GAUGE mode, because tissue saturation is calculated assuming
that the dive uses mix number 1, SCUBA mode is available.
After a dive in GAUGE mode, the Desaturation and NoFly times are updated with
the new tissue saturation data. In particular, the NoFly time is set to 24 hours,
as a precaution in favor of safety, regardless of the type of profile that was run.
After a dive in FREE mode, the residual Desaturation and NoFly time, if any
existed before the dive in FREE mode, will be left unchanged.
Desaturation Time
The tissue Desaturation Time is calculated immediately at the end of the dive.
It is defined as the time necessary for the nitrogen inert gas pressure to be lower
than the Partial pressure of nitrogen (PpN2) breathed, increased by a tolerance
factor.
All calculations refer to the atmospheric pressure measured at the end of the dive.
NOTE: When using the DAN Protocol to calculate the NoFly time, for some dive
profiles it is likely that the NoFly time will be higher than the Desaturation Time,
which might not appear consistent. This is due to the fact that the NoFly time
might derive from a protocol and not from an exact mathematical calculation.
Therefore, in order to avoid creating confusion for the end user, if the NoFly
time calculated at the end of the dive is greater than the Desaturation Time, the
algorithm corrects the Desaturation Time so that it is equal to the NoFly time.
This calculation is to achieve a higher level of safety.
38
Page 39
ACTION
No-fly time
Under the DAN protocol, the NoFly time is calculated according to the following
rules (Revised Flying After Diving Guidelines for Recreational Diving – May 2002):
- 12 hours for a single dive (no dive in the preceding 48 hours) within the nodecompression limits.
- 18 hours for repetiti ve dives without decompression on the same day or multiday.
- 24 hours for repetitive dives with decompression on the same day or multiday.
Since the scenarios that have been studied are limited and the Dive Computer
allows you to assess exactly the load in each individual tissue, the following
strategy will be adopted, in favor of safety:
- The NoFly time is calculated according to the Buhlmann algorithm.
- If the time calculated is lower than the time indicated by the DAN protocol,
then the time obtained from the DAN protocol is used.
- If the time calculated is higher than the time indicated by the DAN protocol,
then the time obtained from the Buhlmann algorithm is used.
The calculation method according to the Buhlmann algorithm will be done
using 0.550bar as the cabin pressure. This is the minimum pressure recorded
in commercial aircraft.
Special cases:
1. If you have not taken any dive, in any mode, in the previous 48 hours:
a. If you take a dive in GAUGE mode, the NoFly time will be 24 hours.
b. If you take a dive in FREE mode, the NoFly time will not be calculated.
2. If you took a SCUBA dive (of any kind):
a. If you take another dive in GAUGE mode before the NoFly time expires,
after the dive in GAUGE mode the NoFly time will be 24 hours.
39
Page 40
Logbook
LAYOUTMENU: LOG
LAYOUTMENU: LOG
Ilsimbolodiallerta viene visualizzato:
1)Se prima dell'immersione inqualsiasimodalità è stato effettuato un RESET.
The computer memory intended for saving SCUBA/GAUGE/FREE dives taken
is limited to:
- approx. 40 hours (Scuba/Gauge mode). Sampling time every 5 seconds.
- approx. 18 hours (Freedive mode). Sampling time every 2 seconds.
If the memory becomes completely full, the oldest dives will be deleted to make
room for new dives.
The alert symbol will be displayed:
1) If before the dive in any mode, a RESET was performed.
2) If a DECO violation occurred during a SCUBA dive.
Display logbook - Scuba dive (OC)
Display logbook - GAUGE dive
Dive mode (GAUGE)
Dive duration – Maximum depth
Date – no. of dives in memory – time of the dive
Temperature – average depth
Display logbook - FREE dive
Dive mode (FREE)
Dive duration – Maximum depth
Date – no. of dives in memory – time of the dive
Temperature – average depth
40
Dive mode (SCUBA/OC)
Dive duration – Maximum depth
Date – no. of dives in memory – time
of the dive
Temperature or O
average depth
% on screen 2 –
2
Page 41
ACTION
La porta seriale è attivata e configurata correttamente.Inattesa di comunicazione.
Connect your ACTION computer to your Mac or PC
The Action can be connected to your Mac or PC through the DiveLogger
program to download dives and run updates.
Updating your Action Dive Computer.
It's very important to keep your Action Dive Computer consistently up to date
with the most recent version of the software.
The Action must be connected to a Mac or PC using the USB cable to run the
updates.
• WARNING!
If an update is available, a new version of the operating system will be
installed.
After every update:
- Check that the Action settings (mix, algorithm, deco stops, etc.) are correct
for the next dive.
- After each update, the Action resets the settings and tissues (see RESET in
this manual).
After connecting your Action to your Mac or PC using the
special USB cable and having set the Action to computer
mode, when “PC LINK ON” appears you can start the
data transfer.
41
Page 42
REPLACING THE BATTERY
• WARNING!
Batteries should always be replaced by an authorized SEAC Center,
because this is a delicate operation with a high probability of subsequent
flooding of the Action if performed by inexpert personnel.
SEAC declines all responsibility for problems resulting from changing the
battery.
• WARNING!
When replacing the CR2450 battery, it's a good idea to also replace the
O-ring of the battery cap an original SEAC O-ring.
a) Unscrew and remove the four screws from the battery compartment.
b) Insert a small flathead screwdriver into the special opening located on the
bottom of the cap to lift the lid.
c) If needed, again using the small flathead screwdriver, prize up the battery
from its housing and remove it.
d) Insert the new battery, snapping it into its housing and making sure that
the “+” polarity sign is facing outward.
e) Remove the old O-ring from the housing in the metal cover and replace
it with the new one. Make sure that the O-Ring is not damaged, and once
inserted make sure it isn't twisted at any point.
f) Position the cover on the Action case, and press it evenly downward. Make
sure that in the area around the screws, the cover is flush with the case.
g) Keep the cover pressed down on the Action case while replacing the four
screws. Although the four screws are screwed through four metal inserts
fixed in the case, we recommend not tightening with excessive force to
reduce the risk of stripping. The recommended torque is 12 Ncm. The
O-ring seal on the battery compartment is radial, so excessive closing force
on the compartment screws is not necessary.
NOTE
Do not dispose of used batteries in the environment or discard them as ordinary
waste; we recommend using special battery disposal services.
42
Page 43
ACTION
ACTION SERIAL NUMBER
The Action serial number is engraved on the back of the case and can also
be viewed on the display in the “INFO” function along with the version of the
firmware installed.
CE CERTIFICATION
The Action is compliant with EC Directives.
The EU Declaration of Conformity is available at: www.seacsub.com
CARE AND MAINTENANCE
• Keep your computer clean and dr y. Do not expose the computer to chemical
agents, including alcohol. Use only fresh water to clean your computer,
removing all saline deposits. Leave the computer to dry naturally; do not use
jets of hot or cold air. A jet of pressurized air hitting the pressure sensor could
damage it irreparably.
• Do not expose the computer directly to the sun or to sources of heat above
50°C. Store the computer in a cool (5°C - 25°C) and dry place.
• Do not place the computer in a hyperbaric chamber.
The computer is designed for a reading accuracy of +/- 2%. The degree of
accuracy required by the European standards is +/- 3.5%.
European standards require that the unit be checked periodically to monitor the
precision of its depth and time readings.
• The warranty will be forfeited if the computer is opened by an unauthorized
service center.
• The computer is manufactured to withstand use in seawater, but after the dive
you must rinse it thoroughly in fresh water and not expose it to direct sunlight
or sources of heat to dry it.
• Check that there are no signs of humidity inside the display.
• Do not attempt to open, modify, or repair the computer yourself. Always
contact an Authorized Center or SEAC directly.
43
Page 44
• WARNING!
If you observe any humidity inside the mineral glass, the Action must be
taken to an authorized SEAC center immediately.
• WARNING!
The mineral glass is subject to possible scratches resulting from improper use.
• WARNING!
Do not use jets of compressed air to dry or clean the Action. This could
damage the pressure sensor.
• WARNING!
Do NOT use solvents to clean the product. Use only running water.
CERTIFICATE OF WARRANTY
The warranty has a duration of two (2) years for the non-professional end user in
accordance with current European regulations.
To exercise the warranty, you must display a copy of your proof of purchase
upon request.
SEAC guarantees the correct operation of this product as described in this
document.
The warranty herein can be exercised according to the conditions and limits
expressly indicated below:
1. The warranty has a duration of two (2) years starting from the time the
product is purchased at a SEAC authorized dealer and requires no prior or
subsequent formal validation.
2. The warranty is acknowledged only to the original buyer of the product
at a SEAC authorized dealer. The warranty is strictly individual; it is not
transferable to third parties unless previously and explicitly authorized by
SEAC.
3. The warranty covers all damage to the device caused by malfunctions
arising from factory defects. Each device is tested in a hyperbaric chamber
before it is made available for purchase.
44
Page 45
ACTION
The warranty covers operating defects deriving from:
• Intrinsic defects caused by the use of materials considered unsuitable.
• Clear errors in the design, manufacturing, or assembling of the product
or its components.
• Incorrect or inadequate instructions and recommendations for use.
4. Any repairs, modifications, transformations, adjustments or tampering
in general carried out on the finished product or parts of it that are not
authorized in advance by SEAC or that are carried out by non-authorized
personnel automatically and immediately void the warranty.
5. The warranty entitles you to assistance and free repair in the shortest
possible time, or to a full free replacement of the product (at the sole
discretion of SEAC) or parts of it whenever a malfunctioning defect
specifically described in item 3 above is acknowledged by SEAC.
6. This warranty may also be exercised by shipping the product believed
to be defective to SEAC. The authorized intermediary for this operation
must be the SEAC dealer where the product was purchased. If this is not
practically possible, solely upon authorization from SEAC, customers may
by authorized to send the defective product to any other SEAC dealer or
directly to SEAC itself.
In order to exercise the warranty, the product must be accompanied by proof of
purchase in the form of a copy of the receipt or invoice (or other equivalent fiscal
record showing the name of the authorized SEAC dealer from which the product
was purchased as well as the date of purchase).
Whenever SEAC receives a product which:
• is not accompanied by proof of purchase having the above mentioned
characteristics;
• is in such condition as to determine the termination of the warranty in
accordance with the provisions of item 4 above;
• has defects resulting from ex ternal and additional causes as compared to the
ones specifically mentioned at item 3 above;
• has been used improperly and/or for uses other than those for which the
product was designed;
• has clearly been damaged or deteriorated through intensive use or normal wear.
45
Page 46
SEAC will not carry out any investigations on the product, and will advise the
sender/authorized dealer.
If the sender still wishes an inspection to be performed, a request to that eect
must expressly state that he/she is willing to bear all the costs relevant to said
inspection (labor, spare parts if any, and shipping charges).
Failing this, SEAC will return the product at the expense and care of the recipient.
The warranty always excludes defects or imperfections deriving from:
• Damage caused by water seepage resulting from improper use; for example,
dirty, damaged, or badly mounted seals resulting from changing the battery,
incorrect closure of the battery compartment, etc.
• Rupture or scratching of the case, glass, or strap as a result of strong impacts.
• Damage resulting from excessive exposure to elevated or low temperatures.
• Damage caused by the use of compressed air to dry and/or clean the dive
computer.
• Improper use or excessive stress.
• Failure to follow the usage instructions.
• Ex ternal agents, such as damage due to transport, blows or falls, atmospheric
agents, natural phenomena, or chemical agents.
• Unauthorized personnel performing maintenance or repairs or opening the
device.
• Pressure testing out of the water.
• Accidents while diving.
• Use other than that intended for the product, or other than that indicated in
the instruction manual. The warranty does not cover depletion of batteries.
Repairs or replacements made during the warranty period do not imply any right
to an extension of the warranty itself.