READ THIS MANUAL THOROUGHLY
MOBILE AIR CONDITIONER
Models:
PAS12 12,000 Btu Cooling Only
PAHS127 12,000 Btu Cooling, 7,000 Btu Heating
950-0060-revA 1-15-07
Introduction ………………………………………………………………………………………………… 3
Theory of Operation ……………………………………………………………………………………… 3
Technical Sp ecificatio ns ……………………………………………………………………………………… 4
Structure………………………………………………………………………………………………………… 5
Operation………………………………………………………………………………………………………… 6
Accessories Installation……………………………………………………………………………………… 20
Maintenance…………………………………………………………………………………………………… 23
Trouble Shooting……………………………………………………………………………………………… 24
Safety Caution and Special Guideline………………………………………………………………………25
Warranty Statement…………………………………………………………………………………………… 26
CONTENTS
2
Mobile Air Conditioner
This Mobile Air Conditioner is a small size appliance which can control the temperature and
humidity in a room. Its flexible characteristics make it easy to use on different occasions and in
different rooms. It also has multiple functions including cooling, heating, dehumidifying, and fan
ventilation. This unit is designed es pecially for the hom e, office , spot cooling/he ating, e tc. it ha s a
compact design compared to others with the same cooling capacity. Power consumption and
noise are especially low.
ATTENTION
Before you use your Mobile Air Conditioner, please read this manual carefully. This Instruction
Manual is for reference only, and does not constitute a contract. We reserve the right to make
technical changes without prior notice.
Theory of Operation
The gas has a heat exchange with air in a room and changes into liquid, then passes to a capillary
tube to lower temperature and pressure and enters into the evaporator. With heat exchange,
refrigerant absorbs heat to lower the temperature. The evaporator is lower than th e d ew point
temperature of air in the room; water vapor will condense on the outside surface of the
evaporator and drop down into the drain tank. This cycle lowers the relative humidity in the room
and attains the goal of dehumidification.
Introduction
3
Technical Sp ecificatio ns
Model PAS12 PAHS127
EER Rating Btu/w 8.8 8.8
Cooling Capacity 12,000BTU 12,000BTU
Heating Capacity N/A 7,000BTU
Rated Voltage 115Vac 115Vac
Rated Frequency 60Hz 60Hz
Rated Current 14.6Amps 14.6Amps
Power Input 1200W 1200W cooling/1500W heating
Rated Input 1500W 1500W
Cycling Airflow 174 CFM 174CFM
Refrigerant/R22 1.21LBS 1.21LBS
Noise Max. 62db(A) 62db(A)
Net WT/Gross WT 99/105.6LBS 99/105.6LBS
Unit Dimensions 17.7x14.5 x33.7 17.7x14.5 x33.7
Dehumidifying Volume 13.9 Gallons/day 13.9 Gallons/day
BRK Size 20A 20A
NOTE:
The cooling capacity indicated is measured at ambient temperature DB 86ºF, WB 77.9ºF (inside
and outside equal).
The heating capacity indicated is measured at ambient temperature D B 68
and outside equal).
The Noise level is taken at a distance of 39” from the front part of the appliance in cooling mode.
The power consumption of the fan is measured with the fan at maximum speed.
The specifications indicated only serve as a reference. Please refer to the informatio n contained
on the appliance data plate.
4
º
F, WB 53.6ºF (inside
OPERATION
ATTENTION:
DEHUMIDIFYING AND COOLING OPERATION
The operating ranges for cooling and dehumidifying operation is 62ºF - 95ºF.
LOCATION:
Put the mobile air conditioner at an open place where the air outlets cannot be covered up. Place
the unit no less than 20 inches away from a wall or other obstacle.
POWER SUPPLY:
Before connecting the air conditioner to the power supply, please check:
The power supply is rated voltage 115V +- 6%.
The power supply line is PROPERLY grounded and sized for a pickup current of 20A, so as to
avoid voltage drops when starting the air conditioner.
The unit is connected to a 16Amp socket by a 16Amp plug. The wire size should be 10AWG.
This room air conditioner is equipped with a power supply cord required by UL. This
power supply cord contains state-of-the-art electronics that sense leakage current. If
the cord is crushed, the electronics detect leakage current and power will be
disconnected in a fraction of a second.
please replace it with a special power supply cord by a qualified electrician.
If the power supply cord of the unit is damaged,
NOTE: Your unit’s device may differ from the ones shown.
6
OPERATION
In order to prevent power fluctuations during the start of the compressor, the following
installation conditions apply:
1. The power source must be capable of handling 16A continuous.
2. Avoid connecting other equipment to this power source.
3. For power details of the air conditioner, refer to the rating plate of the product.
7